• 제목/요약/키워드: Thermal Gradient

검색결과 619건 처리시간 0.031초

통신해양기상위성 해양탑재체 정지궤도 예비 열해석 (PRELIMINARY ON-ORBIT THERMAL ANALYSIS FOR THE GEOSTATIONARY OCEAN COLOR IMAGER OF COMS)

  • 김정훈;전형열;한조영
    • 한국전산유체공학회지
    • /
    • 제15권1호
    • /
    • pp.24-30
    • /
    • 2010
  • A preliminary thermal analysis is performed for the optical payload system of a geostationary satellite. The optical payload considered in this paper is GOCI(Geostationary Ocean Color Imager) of COMS of Korea. The radiative and conductive thermal models are employed in order to predict thermal responses of the GOCI on the geostationary orbit. The results of this analysis are as follows: 1) the GOCI instrument thermal control is satisfactory to provide the temperatures for the GOCI performances, 2) the thermal control is defined and interfaces are validated, and 3) the entrance baffle temperature and shutter wheel motor gradient are found slightly out their specification, therefore further detailed analyses should be continued on these elements.

PC Box교량의 화재에 대한 열응력해석 (The Fire induced Thermal Stress Analysis of PC Box Bridge)

  • 최창근;이계희;최인혁;김일곤
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1998년도 가을 학술발표회 논문집
    • /
    • pp.125-132
    • /
    • 1998
  • In this study the fire, due to overturning of oil tanker on the bridge induced heat transfer analysis and thermal stress analysis are carried out. The results of analysis for fire history of 1 hour present very large thermal gradient near the surface. However, the temperature increase of tendon & rebar that is the main resistant member of bridge is not sufficient to change material properties. The Von-Mises yield criteria is used to calculate the depth of delamination, The depth of delamination is about 4cm at center of fire and this value is close to measured value.

  • PDF

THERMAL PROPERTIES OF SIC/C FUNCTIONALLY GRADIENT MATERIALS BY CVD

  • Kim, Yoo-Taek;Auh, Keun-Ho
    • 한국표면공학회지
    • /
    • 제29권5호
    • /
    • pp.454-458
    • /
    • 1996
  • The computer simulated CVD phase diagrams were completed by the stoichiometric algorithm. Three kinds of SiC/C FGMs: stepwise, semi-continuous, and continuous specimens were prepared according to the simulation. These three types of FGMs and SiC non-FGMs were compared through various thermal test and measurement. In overall judgment, the semi-continuously deposited FGM specimens out of three kinds showed excellent thermal properties as well as a good adhesion to each sub-layer.

  • PDF

가스 터빈 Hot gas casing에 대한 유동 및 열응력 해석 (A study on the flow and thermal analysis of the hot gas casing of gas turbine)

  • 최영진;이영신;김재훈;박원식;김현수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.557-561
    • /
    • 2004
  • The hot gas casing of gas turbine has operated high temperature and thermal gradient. The structure safety of hot gas casing will be highly depend on the thermal stress. In this paper, flow and thermal stress analysis of hot gas casing is carried out using ANSYS program. The obtained temperature data by flow analysis of hot gas casing apply the load condition of the thermal analysis. The thermal stress analysis is carry out the elastic-plasticity analysis. The pressure, temperature and velocity of the flow and thermal stress of the hot gas casing are presented.

  • PDF

인공위성 영상기의 열모델링 방법 (THERMAL MODELING TECHNIQUE FOR A SATELLITE IMAGER)

  • 김정훈;전형열;유명종;김병수
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2010년 춘계학술대회논문집
    • /
    • pp.174-180
    • /
    • 2010
  • Conductive and radiative thermal model configurations of an imager of a geostationary satellite are presented. A two-plane method is introduced for three dimensional conductive coupling which is not able to be treated by thin shell plate thermal modeling technique. Especially the two-plane method is applied to massive matters and PIP(Payload Interface Plate) in the imager model. Some massive matters in the thermal model are modified by adequate correction factors or equivalent thickness in order to obtain the numerical results of thermal modeling to be consistent with the analytic model. More detailed nodal breakdown is specially employed to the object which has the rapid temperature gradient expected by a rule of thumb. This detailed thermal model of the imager is supposed to be used for detailed analyses and test predictions, and be correlated with the thermal vacuum test results before final in-flight predictions.

  • PDF

Characterization of Thermal Products of Alpha-Tocopherol

  • Chung, Hee-Young
    • Preventive Nutrition and Food Science
    • /
    • 제9권4호
    • /
    • pp.295-299
    • /
    • 2004
  • Alpha-tocopherol was thermally oxidized and degraded at high temperatures and the resulting products were chromatographically separated and identified by LC-MS. Alpha-tocopherol dissolved in glycerol was heated at 200^{\circ}C for 30 min. The thermal products were separated by hexane extraction and analyzed by HPLC using a reversed phase $\mu$-Bondapak $C_{18}-column$ with two kinds of elution solvents: a mixture of acetonitrile and methanol (3:2), and of acetonitrile, methanol, 2-propanol, chloroform and methylene chloride (3:2:5:0.5:0.5) in a gradient mode. The isolated thermal. products of alpha-tocopherol were more viscous than alpha-tocopherol, and dark brown in color. Major thermal degradation products of alpha-tocopherol were identified by LC-MS, and the structures of thermal products were proposed. Alpha-tocopherol and its thermal degradation products were degraded into fragments, mainly at the non-aromatic parts. The degradation products of alpha-tocopherol. were combined with oxidized product (tocopherylquinone) to make thermal. products through dimerization.

우리나라의 지열자원 분표 (Distribution of geothermal resources of Korea)

  • 김형찬;이철우;송윤호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.674-677
    • /
    • 2005
  • The characteristics of geothermal resources in Korea was roughly estimated using hot springs, 580 geothermal gradients and 338 heat flow data. In the aspect of hot springs with geologic structure, location of hot springs coincide with fault zone, especially younger age of Cretaceous to Tertiary. In the aspect of geothermal gradients, Pohang area shows the highest geothermal gradient anomaly, which is covered with unconsol idated rock of low thermal conductivity preserving the residual heat from igneous activity or radioactivity elements decay. In the aspect of heat flow density, high anomaly can be found along the zone connecting Uljin-Pohang-Busan on the southeastern part of Korean peninsula at which big fault zone as Yangsan fault is well developed.

  • PDF

스탠딩컬럼웰(SCW)을 적용한 지열히트펌프의 성능에 대한 매개변수 연구 (A parametric study on the performance of heat pump using standing column well(SCW))

  • 장재훈;박두희
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.625-630
    • /
    • 2010
  • Parametric study was performed using the SCW numerical model for evaluating the performance of the SCW. The five ground related parameters, which are porosity, hydraulic conductivity, thermal conductivity, specific heat, geothermal gradient, and five SCW design parameters, which are pumping rate, well depth well diameter, dip tube diameter, bleeding rate, were used in the study. Numerical simulations were performed for short-term (24-hour) simulation. The study results indicate that the parameters that have important influence on the performance of SCW were hydraulic conductivity, thermal conductivity, geothermal gradient, pumping rate, and bleeding rate. Overall, this study showed that various factors had a cumulative influence on the performance of the SCW, and a numerical simulation can be used to accurately predict the performance of the SCW.

  • PDF

알루미늄 합금의 TCG 조직의 형성기구 (Mechanism of Twin Columnar Growth in Aluminum Alloys)

  • 김동건
    • 한국주조공학회지
    • /
    • 제7권3호
    • /
    • pp.192-198
    • /
    • 1987
  • Commercial semicontinuous cast ingots of aluminum alloys often exhibit large grains composed of parallel arrays of continuous lamellae. Each lamella consists of a central {111} coherent twin boundary and wavy solidification boundary. This microstructure is referred to as a twin columnar growth(TCG) structure. The factors influencing the formation of a TCG structure include a unidirectional thermal gradient and the critical range of the alloying element content. The higher the thermal gradient is, the shorter the twin plane spacings are. The composition profile for an untwinned dendrite shows maximums at the positions of the interdendritic channels and the minimum appears at the center of the dendrite. While for twinned dendrite, it has wavy apperance. This profile has two local minimums instead of one shown in the untwinned.

  • PDF

진동하에서 일방향응고 시킨 $Al-CuAl_2$ 공정복합재료의 응고에 관한 연구 (Unidirectional Solidification of $Al-CuAl_2$ Eutectic Composites under Forced Convection by Vibration)

  • 이현규;이길홍
    • 한국주조공학회지
    • /
    • 제18권3호
    • /
    • pp.234-239
    • /
    • 1998
  • Unidirectional solidification of $Al-CuAl_2$ eutectic composites was studied under the condition of forced convection by vibration. It has been shown that thermal gradient for solid is different from that for liquid during solidification under force convection by vibration. With increase of vibration, mobility of liquid increases, but decreases with decreasing vibration. The rate of solidification is very high initially, and decreases suddenly. For further solidification, the rate of solidification decrceases slowly, and shows a L-type behavior. The mechanical vibration during solidification effects efficiently on nucleation, and induces a forced convection in liquid. By the forced convection, great thermal gradient of liquid interface between solid and liquid can be obtained. The amount of solute near the interface also decreases as solute distribution is improved by the forced convection.

  • PDF