• 제목/요약/키워드: Thermal Environmental Elements

검색결과 89건 처리시간 0.024초

Design Parameter Structure for Architectural Elements of External Kinetic Facade

  • Ji, Seok-Hwan;Lee, Byung-Yun
    • KIEAE Journal
    • /
    • 제16권3호
    • /
    • pp.35-46
    • /
    • 2016
  • Purpose: This paper aims to analyse the composition system of architectural elements including shape, kinetic and material elements of kinetic facades and establish the design parameter system as a common conceptual and practical knowledge sharing platform with mechanical and electrical experts. Method: This research has been conducted in a three steps. At first, 120 cases of external shading devices are analyzed and their classification criteria have been established. Secondly geometric, kinetic and material elements are categorized in a common kinetic facade coordinates system considering environmental effects and operation method, and the applicability of combination of each element are tested. Lastly core design parameters for each element have been established in a common office building installation coordinate. Result: Geometry elements are categorized into seven geometric shapes and kinetic elements is categorized into basic linear and rotational motion and combinational folding and rolling motion. The combined set of parameters for three elements composes the whole design parameters for architectural elements of kinetic façade. Design parameters of shape elements are composed of shape, installation and arrangement parameters; design parameters for kinetic elements are composed of axis and range parameters; and design parameters of material elements are composed of thermal, lighting and color parameters.

부산 금정산-백양산 일대 용천수, 지하수 및 지열수의 지화학적 특성 (Geochemical characteristics of spring, ground and thermal waters in Mt. Geumjeong-Mt. Baekyang area, Pusan)

  • 함세영;조명희;황진연;김진섭;성익환;이병대
    • 한국환경과학회지
    • /
    • 제9권3호
    • /
    • pp.229-239
    • /
    • 2000
  • Spring, ground and thermal waters in the vicinity of Mt. Geumjeong and Mt. Baekyang area have been sampled and analyzed for major and minor elements. According to the Piper diagram, spring water belongs to $Ca-HCO_3$ and $Na-HCO_3$ types, groundwater to $Ca-HCO_3$ type, and thermal water to Na-Cl type. Based on the phase stability diagrams of $[Ca^{2+}]/{[H^+]}^2, [Mg^{2+}]/{[H^+]}^2, [K^+]/[H^+]$, and $[Na^+]/[H^+] vs. [H_4SiO_4]$, spring water, groundwater and thermal water are mostly in equilibrium with kaolinite. The result of factor analysis shows three factors (factor 1, 2 and factor 3) for the spring water, the groundwater and the thermal water which are represented by the influence of the dissolution of feldspar, calcite, anthropogenic sources (domestic and industrial wastes) and salt water.

  • PDF

소형아파트의 방위에 따른 실내온열환경 실태와 평가 (Thermal Environment of Small-size Apartments Facing in Two Different Directions)

  • 최윤정
    • 대한가정학회지
    • /
    • 제31권3호
    • /
    • pp.213-222
    • /
    • 1993
  • The purpose of this study was to investigate the present conditions of thermal environment in small-size apartments. The research methods used were measuring of environmental elements and personal self-administration for the residents' thermal comfort responses. The house subjected were 25 peung apartments facing southeast and southwest directions. The results of this study were summarized as follow ; The indoor temperature and humidity of houses subjected were 25.0∼27.3℃, 37.1∼42.5%. Compared with the distribution of indoor temperature and globe temperature of houses subjected, those of southeast house were more stable. And in the residents' thermal sensation responses, the residents of southeast houses checked more often neutral zone. Therefore the thermal environment of southeast houses were more comfortable condition than southwest houses.

  • PDF

자연채광 요소기술 도출을 위한 창호시스템과 건물요소와의 통합화에 관한 연구 (A Study on Integration of Pre-manufactured Window Systems with Conventional Building Design Elements)

  • 김정태;정인영;정유근
    • KIEAE Journal
    • /
    • 제2권2호
    • /
    • pp.15-22
    • /
    • 2002
  • Importation of mass production of building elements with standardization are vital way for environment-friendly architectural planning, which it makes the lifespan of a building longer than normal with easier maintenance and remodeling. The advantage might be magnified here in Korea since typical types of apartment house are dominated in our construction market. For the purpose, a series of pre-manufactured window systems is one of the optimal elements to be prototype building modules. In the design process of the system windows, lots of consideration should be involved and they include aesthetics, thermal performance, noise reduction, airtightness, and so forth. A real survey on the ready-made window systems has been performed and its optical issue related to luminous peculiarity is what is of major interest in this study. In addition, technical review on more advanced window products and their adaptable potential for the integration with fundamental architectural design elements were carried out.

열성층 및 냉각재 환경이 오스테나이트 배관의 피로수명에 미치는 영향 평가 (Evaluation of Thermal Stratification and Primary Water Environment Effects on Fatigue Life of Austenitic Piping)

  • 최신범;우승완;장윤석;최재붕;김영진;이진호;정해동
    • 대한기계학회논문집A
    • /
    • 제32권8호
    • /
    • pp.660-667
    • /
    • 2008
  • During the last two decades, lots of efforts have been devoted to resolve thermal stratification phenomenon and primary water environment issues. While several effective methods were proposed especially in related to thermally stratified flow analyses and corrosive material resistance experiments, however, lack of details on specific stress and fatigue evaluation make it difficult to quantify structural behaviors. In the present work, effects of the thermal stratification and primary water are numerically examined from a structural integrity point of view. First, a representative austenitic nuclear piping is selected and its stress components at critical locations are calculated in use of four stratified temperature inputs and eight transient conditions. Subsequently, both metal and environmental fatigue usage factors of the piping are determined by manipulating the stress components in accordance with NUREG/CR-5704 as well as ASME B&PV Codes. Key findings from the fatigue evaluation with applicability of pipe and three-dimensional solid finite elements are fully discussed and a recommendation for realistic evaluation is suggested.

BIM and Thermographic Sensing: Reflecting the As-is Building Condition in Energy Analysis

  • Ham, Youngjib;Golparvar-Fard, Mani
    • Journal of Construction Engineering and Project Management
    • /
    • 제5권4호
    • /
    • pp.16-22
    • /
    • 2015
  • This paper presents an automated computer vision-based system to update BIM data by leveraging multi-modal visual data collected from existing buildings under inspection. Currently, visual inspections are conducted for building envelopes or mechanical systems, and auditors analyze energy-related contextual information to examine if their performance is maintained as expected by the design. By translating 3D surface thermal profiles into energy performance metrics such as actual R-values at point-level and by mapping such properties to the associated BIM elements using XML Document Object Model (DOM), the proposed method shortens the energy performance modeling gap between the architectural information in the as-designed BIM and the as-is building condition, which improve the reliability of building energy analysis. Several case studies were conducted to experimentally evaluate their impact on BIM-based energy analysis to calculate energy load. The experimental results on existing buildings show that (1) the point-level thermography-based thermal resistance measurement can be automatically matched with the associated BIM elements; and (2) their corresponding thermal properties are automatically updated in gbXML schema. This paper provides practitioners with insight to uncover the fundamentals of how multi-modal visual data can be used to improve the accuracy of building energy modeling for retrofit analysis. Open research challenges and lessons learned from real-world case studies are discussed in detail.

Updating BIM: Reflecting Thermographic Sensing in BIM-based Building Energy Analysis

  • Ham, Youngjib;Golparvar-Fard, Mani
    • 국제학술발표논문집
    • /
    • The 6th International Conference on Construction Engineering and Project Management
    • /
    • pp.532-536
    • /
    • 2015
  • This paper presents an automated computer vision-based system to update BIM data by leveraging multi-modal visual data collected from existing buildings under inspection. Currently, visual inspections are conducted for building envelopes or mechanical systems, and auditors analyze energy-related contextual information to examine if their performance is maintained as expected by the design. By translating 3D surface thermal profiles into energy performance metrics such as actual R-values at point-level and by mapping such properties to the associated BIM elements using XML Document Object Model (DOM), the proposed method shortens the energy performance modeling gap between the architectural information in the as-designed BIM and the as-is building condition, which improve the reliability of building energy analysis. The experimental results on existing buildings show that (1) the point-level thermography-based thermal resistance measurement can be automatically matched with the associated BIM elements; and (2) their corresponding thermal properties are automatically updated in gbXML schema. This paper provides practitioners with insight to uncover the fundamentals of how multi-modal visual data can be used to improve the accuracy of building energy modeling for retrofit analysis. Open research challenges and lessons learned from real-world case studies are discussed in detail.

  • PDF

무극 함금석영맥광상 화강암질모암에서의 원소들의 분산형태와 분산범위 (Primary Dispersion Patterns and Widths of Elements in Altered Granitic Wallrock around the Gold-bearing Quartz Veins at the Mugeug Mine)

  • 황인호;전효택
    • 자원환경지질
    • /
    • 제27권5호
    • /
    • pp.451-458
    • /
    • 1994
  • Geochemical studies on gold-bearing quartz veins and granitic wallrocks from the Mugeug mine were carried out in order to investigate primary dispersion patterns of elements and to quantify primary dispersion widths of elements with distance from the gold-bearing quartz veins. The best fitting model of dispersion pattern in altered wallrock around the gold-bearing quartz veins is an exponential function for Au, As, Sb, $Na_2O$ and Sr, and a quadratic function for CaO, $K_2O$, MnO, Ba, Rb and Cs. The primary dispersion widths are 15~343 cm in the hanging wall, and 33~173 cm in the footwall. The width of primary dispersion in the hanging wall is twice as thick as that in the footwall mainly due to the thermal effect and volatile components. The primary dispersion width is increased as the increase of gold-bearing quartz vein width and contents of As and Sb in gold-bearing quartz veins, but is not related to Au content in gold-bearing quartz veins.

  • PDF

노인복지시설의 하절기 실내 온열환경과 노인의 주관적 반응평가에 관한 연구 -대구광역시 소재 노인복지시설을 중심으로 (A Study on the Estimate of Thermal Environment and the Subjective Responses of the Aged during Summer in the Welfare Facilities -Focused on the Welfare Facilities for the Aged in Taegu-)

  • 이형우;홍원화
    • 한국주거학회논문집
    • /
    • 제13권2호
    • /
    • pp.23-29
    • /
    • 2002
  • The purpose of this study was to find out the present condition of indoor thermal environment and to investigate the environmental needs of the elderly through the measurement of outdoor and indoor physical thermal environment elements and the questionary survey of the response to thermal environment in two welfare facilities for the aged in Taegu during summer in 2001. The 38 residents among the total of 134 residents were asked to record their feelings. The result of this study was as follows. The indoor thermal environment in the facilities subjected leer this study was seemed to be comfortable comparatively. But the values of mean indoor temperature measured were about 1.6-1.8$^{\circ}C$ higher than that of a existing domestic research suggested as thermal comfort zones for the elderly during summer, and most residents fe1t somewhat hot in inner space. And the value of indoor relative humidity in one facility was out from the range of comfort humidity(40-70%). Also there were differences by the geographical location between the two.

유한요소 해석을 통한 열교 차단장치의 압축판 최적형상 설계 (The Optimal Shape Design for the Compression Joint of Thermal Bridge Breaker using FEM)

  • 신동현;김영호;김형준
    • 한국디지털건축인테리어학회논문집
    • /
    • 제13권2호
    • /
    • pp.17-25
    • /
    • 2013
  • It is important to eliminate thermal bridge for achieving passive and environmental-friendly buildings. Structural members may frequently act as thermal bridges that become a conduit of energy. it is emphasized that thermal bridge breaker (TBB) system is necessary for blocking thermal bridge of the structural members. This TBB system has to maintain a performance to tensile and compressive stress which arises in member section in order to being realized structurally. Thus, it is composed with anchorage devices which obtain continuity with structural members inside building and rebar of cantilever balcony, and compression joint which resist compression stress occurring to TBB. Applying method of TBB's compression joint is designed to have high strength with comparatively small element section which can cover external load. This study carried out finite elements method based on compression experiment. Throughout the FEM analysis, this study provides information on finding optimal shape for compression joint of TBB which can suitably apply to current building balcony of Korea.