• 제목/요약/키워드: Thermal Energy Need

검색결과 181건 처리시간 0.026초

Intermittent Heating and Cooling Load Calculation Method -Comparing with ISO 13790

  • Lee, Sang-Hoon
    • Architectural research
    • /
    • 제14권1호
    • /
    • pp.11-18
    • /
    • 2012
  • College of Architecture, Georgia Institute of Technology, Atlanta, GA, US Abstract The intermittent heating and cooling energy need calculation of the ISO 13790 monthly method was examined. The current ISO 13790 method applies a reduction factor to the continuous heating and cooling need calculation result to derive the intermittent heating and cooling for each month. This paper proposes a method for the intermittent energy need calculation based on the internal mean temperature calculation. The internal temperature calculation procedure was introduced considering the heat-balance taking into account of heat gain, heat loss, and thermal inertia for reduced heating and cooling period. Then, the calculated internal mean temperature was used for the intermittent heating and cooling energy need calculation. The calculation results from the proposed method were compared to the current ISO 13790 method and validated with a dynamic simulation using EnergyPlus. The study indicates that the intermittent heating and cooling energy need calculation method using the proposed model improves transparency of the current ISO 13790 method and draws more rational outcomes in the monthly heating and cooling energy need calculation.

Inactivation of Airborne E. coli and B. subtilis Bioaerosols Utilizing Thermal Energy

  • Lee, Yun-Ha;Lee, Byung-Uk
    • Journal of Microbiology and Biotechnology
    • /
    • 제16권11호
    • /
    • pp.1684-1689
    • /
    • 2006
  • Airborne microorganisms, which are currently termed bioaerosols, have received attention owing to the harmful effects they have on human health. As the concern over airborne microorganisms grows, there also grows an urgent need to study and develop efficient methods for controlling them. In this study, thermal energy using a thermal tube was tested as a control method, mainly against airborne E. coli. For a comparison, B. subtilis var. niger spores were utilized in the experimentation. It was found that the widely known inactivation conditions for microorganisms were not adequate against airborne microorganisms. The experimental results demonstrated the need for extensive studies that should investigate adequate and economic conditions to control against airborne bacteria. In this study, thermal energy exposed by the thermal tube demonstrated an inactivation performance for controlling E. coli bioaerosols.

지하 열에너지 저장 기술 및 스웨덴 암반공동내 열수 저장 사례 (Technologies of Underground Thermal Energy Storage (UTES) and Swedish Case for Hot Water)

  • 박도현;김형목;류동우;최병희;선우춘;한공창
    • 터널과지하공간
    • /
    • 제22권1호
    • /
    • pp.1-11
    • /
    • 2012
  • 열에너지 저장은 고온 또는 저온의 열에너지를 임시 저장하는 것으로서 에너지 수요와 공급 사이의 불균형을 줄일 수 있고, 이를 통해 에너지를 절약하고 에너지 이용효율을 향상시킬 수 있다. 특히 간헐적으로 에너지를 생산하는 신재생에너지의 경우 에너지 저장 장치와의 조합은 필수적이다. 또한 지하 암반의 낮은 열전도도와 높은 열용량을 이용하여 지하에 열에너지를 저장하는 경우 열손실을 최소화하여 추가적인 효율 향상이 기대된다. 본 고에서는 지하 열에너지 저장 기술을 조사 분석하고 스웨덴에 암반공동내 열에너지 저장 사례를 소개하였다.

Effective modelling of borehole solar thermal energy storage systems in high latitudes

  • Janiszewski, Mateusz;Siren, Topias;Uotinen, Lauri;Oosterbaan, Harm;Rinne, Mikael
    • Geomechanics and Engineering
    • /
    • 제16권5호
    • /
    • pp.503-512
    • /
    • 2018
  • Globally there is an increasing need to reduce the greenhouse gas emissions and increase the use of renewable sources of energy. The storage of solar thermal energy is a crucial aspect for implementing the solar energy for space heating in high latitudes, where solar insolation is high in summer and almost negligible in winter when the domestic heating demand is high. To use the solar heating during winter thermal energy storage is required. In this paper, equations representing the single U-tube heat exchanger are implemented in weak form edge elements in COMSOL Multiphysics(R) to speed up the calculation process for modelling of a borehole storage layout. Multiple borehole seasonal solar thermal energy storage scenarios are successfully simulated. After 5 years of operation, the most efficient simulated borehole pattern containing 168 borehole heat exchangers recovers 69% of the stored seasonal thermal energy and provides 971 MWh of thermal energy for heating in winter.

A Thermal Conductivity Model for LWR MOX Fuel and Its Verification Using In-pile Data

  • Byung-Ho Lee;Yang-Hyun Koo;Jin-Silk Cheon;Je-Yong Oh;Hyung-Koo Joo;Dong-Seong Sohn
    • Nuclear Engineering and Technology
    • /
    • 제34권5호
    • /
    • pp.482-493
    • /
    • 2002
  • The MOX fuel for LWR is fabricated either by direct mechanical blending of UO$_2$ and PuO$_2$ or by two stage mixing. Hence Pu-rich particles, whose Pu concentrations are higher than pellet average one and whose size distribution depends on a specific fabrication method, are inevitably dispersed in MOX pellet. Due to the inhomogeneous microstructure of MOX fuel, the thermal conductivity of LWR MOX fuel scatters from 80 to 100 % of UO$_2$ fuel. This paper describes a mechanistic thermal conductivity model for MOX fuel by considering this inhomogeneous microstructure and presents an explanation for the wide scattering of measured MOX fuel's thermal conductivity. The developed model has been incorporated into a KAERI's fuel performance code, COSMOS, and then evaluated using the measured in-pile data for MOX fuel. The database used for verification consists of homogeneous MOX fuel at beginning-of-life and inhomogeneous MOX fuel at high turnup. The COSMOS code predicts the thermal behavior of MOX fuel well except for the irradiation test accompanying substantial fission gas release. The over-prediction with substantial fission gas release seems to suggest the need for the introduction of a recovery factor to a term that considers the burnup effect on thermal conductivity.

분산형 마이크로 터빈 열병합 발전시스템 개발 (Development of Distributed Micro Turbine Co-generation System)

  • 권기훈;김승우;이시우
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.320-327
    • /
    • 2002
  • In concert with the growing emphasis placed on distributed power generation there will be a need, in the first decade of the 21th century, for a compact thermal energy system capable of providing the total energy needs of individual homes. A natural gas fueled co-generation micro-turbine with ultra low emission will meet this need. Market opportunities for a distributed micro turbine co-generation system are projected to increase dramatically. In this paper, It was determined that with current state of art component performance levels, metrallic materials, thermal efficiency goal of $28\%$ at sea level standard day conditions are attainable. Higher overall thermal efficiency of $78\%$ is attainable with micro-turbine combined with exhaust fired boilers.

  • PDF

초고온 태양열을 이용한 태양연료 생산기술 연구동향 (Review on the Solar Fuel Production Technology Using High-Temperature Solar Furnace)

  • 강용혁;김진수;이상남;윤환기;유창균
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.408-411
    • /
    • 2005
  • Solar fuel production technology using high-temperature solar furnace was briefly reviewed in this paper. 'Hydrogen' which is known to be the most promising energy carrier in the near future is to be generated environment-friendly from non-carbon resources. Combination of solar furnace operated by concentrated solar energy and high-temperature thermal reactions could be one of the most efficient ways to fulfill this need eventually. Various reaction mechanisms are feasible within a wide spectrum of solar fuel production technology, but intensive research efforts in related key areas need to be taken for successful development and commercialization of the technology.

  • PDF

에너지 슬래브의 열-역학적 수치해석 모델 개발 (Development of Thermomechanical Coupled Numerical Model for Energy Slab)

  • 박상우;최항석;이석재
    • 한국지반공학회논문집
    • /
    • 제40권1호
    • /
    • pp.55-63
    • /
    • 2024
  • 본 연구에서는 에너지 슬래브의 안정성을 검토하기 위해 열-역학적 수치해석 모델을 개발하였다. 먼저, 주거용 건물 지하주차장에 벽체형 에너지 슬래브를 설치한 뒤 현장 열성능 평가시험(Thermal performance test, TPT)을 수행하였다. 이를 기반으로 현장 열성능 평가시험의 열-수리학적 거동을 정교하게 모사할 수 있는 에너지 슬래브의 열-수리학적 수치해석 모델을 개발하였다. 마지막으로, 열-수리학적 모델을 통해 도출된 시간-온도 데이터를 기반으로 에너지 슬래브의 열-역학적 수치해석 모델을 개발하였다. 개발된 모델을 기반으로 에너지 슬래브의 운용에 따른 열응력을 산정한 결과 최대 5,300kPa의 열응력이 발생하였으며, 이는 에너지 슬래브의 안정적인 운용을 위해 충분한 인장강도가 확보된 시멘트 몰탈 활용이 필요하다는 것을 시사한다.

Ocean energy in Indian coasts and islands for sustainability-A roadmap for future

  • Dauji, Saha
    • Advances in Energy Research
    • /
    • 제5권4호
    • /
    • pp.305-320
    • /
    • 2017
  • Limited quantity and non-uniform distribution of fossil fuel over the world, along with the environmental concerns of increasing $CO_2$ emissions, indicate that gradual and planned switchover to the sustainable energy sources is the need of the day. Ocean energy is well-distributed over the coasts, abundant, renewable and available in the form of wave energy, tidal energy and thermal energy. India has gathered precious experience from the pilot plants utilizing these methods over the last few years. One of the main constraints is deemed to be the grid connectivity. Time has come to transform this limitation into opportunity. Ocean power can be a very suitable option for the coastal belts and the islands. Implementation of this concept would require large-scale industry participation along with favourable government policies in the coming years. This article attempts a review of the ocean energy initiatives in India and proposes a roadmap for the future.

Design of a renewable energy system with battery and power-to-methanol unit

  • Andika, Riezqa;Kim, Young;Yun, Choa Mun;Yoon, Seok Ho;Lee, Moonyong
    • Korean Journal of Chemical Engineering
    • /
    • 제36권1호
    • /
    • pp.12-20
    • /
    • 2019
  • An energy storage system consisting of a battery and a power-to-methanol (PtM) unit was investigated to develop an energy storage system for renewable energy systems. A nonlinear programming model was established to optimize the energy storage system. The optimal installation capacities of the battery and power-to-methanol units were determined to minimize the cost of the energy system. The cost from a renewable energy system was assessed for four configurations, with or without energy storage units, of the battery and the power-to-methanol unit. The proposed model was applied to the modified electricity supply and demand based on published data. The results show that value-adding units, such as PtM, need be included to build a stable renewable energy system. This work will significantly contribute to the advancement of electricity supply and demand management and to the establishment of a nationwide policy for renewable energy storage.