Hybrid infrared-visible multiview correlation to study damage in a woven composite complex-shaped specimen

  • Andrija Zaplatic;Zvonimir Tomicevic;Xuyang Chang;Ivica Skozrit;Stephane Roux;Francois Hild
    • Coupled systems mechanics
    • /
    • v.12 no.5
    • /
    • pp.445-459
    • /
    • 2023
  • In this study, a cyclic tensile test on a notched butterfly specimen made of woven glass fiber composite was performed on a modified Arcan fixture. During the mechanical test, the sample was monitored with a hybrid stereoscopic system comprised of two visible lights and one infrared camera. The visible light cameras were employed for kinematic measurements using a finite-element-based multiview correlation technique. A semi-hybrid correlation approach was followed, providing Lagrangian temperature fields of the Region of Interest. Due to the complex composite architecture and specimen shape, localized shearing was observed during the tensile loading. Furthermore, asymmetrical damage developed around the notches as revealed by localized strains and thermal hot spots.

Effect of Cyclic Moisture Content Changes on Shrinkage and Thermal Conductivity in Domestic Quercus acutissima Carr. and Larix Kaempferi Carr. (국내산 상수리나무와 일본 잎갈나무의 수축율과 열전도율에 대한 주기적인 함수율 변화의 영향)

  • Mun, Sung-Hee;Cha, Jae-Kyung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.30 no.4
    • /
    • pp.41-50
    • /
    • 2002
  • Small clear specimens of Quercus acutissima Carr. and Larix caempferi Carr. were used to measure shrinkage and thermal conductivity for the reasonable and effective use. All samples were conditioned to 18, 12, 5% moisture contents in a humidity chamber of 86, 66, 20% relative humidity(RH), respectively and room temperature(23℃) All specimens were conducted on the shrinkage and thermal conductivity test at each MCs. These processes(cycle) were repeated three times. The radial and tangential shrinkages of Quercus acutissima Carr. and Larix caempferi Carr. decreased at each level of MCs, with the increasing cycles. The radial and tangential shrinkages increased as the specific gravity(on oven-dry weight and volume basis) increased. Thermal conductivities of the radial and tangential direction of Quercus acutissima Carr. and Larix caempferi Carr. increased at each levels of MCs, with increasing cycles. Good correlations were obtained between shrinkages and thermal conductivities of radial and tangential direction, and specific gravity (on oven-dry weight and oven-dry volume basis) and MC.

Decrease in hydrogen crossover through membrane of polymer electrolyte membrane fuel cells at the initial stages of an acceleration stress test

  • Hwang, Byung Chan;Oh, So Hyeong;Lee, Moo Seok;Lee, Dong Hoon;Park, Kwon Pil
    • Korean Journal of Chemical Engineering
    • /
    • v.35 no.11
    • /
    • pp.2290-2295
    • /
    • 2018
  • An acceleration stress test (AST) was performed to evaluate the durability of a polymer membrane in a polymer electrolyte membrane fuel cell (PEMFC) for 500 hours. Previous studies have shown that hydrogen crossover measured by linear sweep voltammetry (LSV) increases when the polymer membrane deteriorates in the AST process. On the other hand, hydrogen crossover of the membrane often decreases in the early stages of the AST test. To investigate the cause of this phenomenon, we analyzed the MEA operated for 50 hours using the AST method (OCV, RH 30% and $90^{\circ}C$). Cyclic voltammetry and transmission electron showed that the electrochemical surface area (ECSA) decreased due to the growth of electrode catalyst particles and that the hydrogen crossover current density measured by LSV could be reduced. Fourier transform infrared spectroscopy and thermogravimetric/differential thermal analysis showed that -S-O-S- crosslinking occurred in the polymer after the 50 hour AST. Gas chromatography showed that the hydrogen permeability was decreased by -S-O-S- crosslinking. The reduction of the hydrogen crossover current density measured by LSV in the early stages of AST could be caused by both reduction of the electrochemical surface area of the electrode catalyst and -S-O-S- crosslinking.

Weathering Performance Evaluation of Duplex Coating Systems of Thermal Spraying and Painting using Corrosion Test (부식실험에 의한 금속용사와 도장의 복합피복방식법의 내후성능평가)

  • Kim, In Tae;Kim, Ho Seob;Kien, Dao Duy;Jun, Je Hyeong;Ahn, Jin Hee
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.2
    • /
    • pp.97-108
    • /
    • 2016
  • Thermally sprayed metals or organic coatings is often used in corrosion protection of steel structures. Duplex coating systems of thermally sprayed metal in combination with organic coating are selected as a new generic type of coatings on steel structures under the highly corrosive environments. In this study, three types of corrosion tests were carried out on four types of thermal sprayed specimens with sealing: zinc, zinc-15%aluminum alloy, aluminum and aluminum-5%magnesium alloy, four types of duplex coated specimens; thermally sprayed metals in combination with paint of acrylic urethane, and painted specimens. NORSOK M-501, Wet/dry cyclic seawater tests and outdoor exposure tests of nine types of specimens were conducted. From the corrosion test results, weathering performance of them were presented.

Troubleshooting of Combustor for Auxiliary Power Unit during Engine/System Test (엔진 및 체계시험 중 발생한 보조동력장치 연소기 문제해결과정)

  • Lim, Byeungjun;Park, Heeho;Lee, Seungjoon;Sung, Okseok
    • Aerospace Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.57-64
    • /
    • 2012
  • Although the APU combustors were developed successfully, it could face many unexpected hardships in an engine or a system operating under the severe environments. But, it is not easy to change the combustion field or combustor structure at the engine/system development stage. So we must suggest practical ways to optimize the value quantitatively by engine test and flow analysis, and verify those by the cyclic test. This paper describes reverse-annular type combustor troubleshooting processes for verifying and settling of the problems and issues occurred in various engine and system operation tests by experiment and analysis.

A Study on Correlation between A/F and ion signal in a Constant-Volume Chamber Using Spark-plug Ionization Probe Itself (정적챔버에서 스파크 플러그 이온프로브를 이용한 공연비와 이온신호와의 상관관계에 대한 연구)

  • Park, Jong-Il;Chun, Kwang-Min;Hahn, Jae-Won;Park, Chul-Woong
    • 한국연소학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.223-229
    • /
    • 2002
  • Spark plug ionization signal could be useful in an internal combustion engine as a feedback signal for combustion diagnostics such as misfire detection, knocking detection and lambda control, but the signal has high level of cyclic fluctuation in an internal combustion engine due to residual gas, pressure, temperature, mixture composition in the spark gap. Because of this reason it is very difficult to apply ion signal to commercial engine control. In this Study, a correlation between A/F and spark plug ionization signal was studied in a constant volume chamber. Constant volume chamber with gas phase fuel(Propane) has homogeneous fuel composition , no mixture flow, same pressure and temperature on each test. The results show that mean chemi-ion signal has the highest correlation with A/F and intial pressure change has on effect on the thermal-ion signal and not on chemi-ion signal.

  • PDF

Influence of flexural loading on chloride ingress in concrete subjected to cyclic drying-wetting condition

  • Ye, Hailong;Fu, Chuanqing;Jin, Nanguo;Jin, Xianyu
    • Computers and Concrete
    • /
    • v.15 no.2
    • /
    • pp.183-198
    • /
    • 2015
  • Chloride ingress implies a complex interaction between physical and chemical process, in which heat, moisture and chloride ions transport through concrete cover. Meanwhile, reinforced concrete structure itself undergoes evolution due to variation in temperature, relative humidity and creep effects, which can potentially change the deformation and trigger some micro-cracks in concrete. In addition, all of these process show time-dependent performance with complex interaction between structures and environments. In the present work, a time-dependent behavior of chloride transport in reinforced concrete beam subjected to flexural load is proposed based on the well-known section fiber model. The strain state varies because of stress redistribution caused by the interaction between environment and structure, mainly dominated by thermal stresses and shrinkage stress and creep. Finally, in order to clear the influence of strain state on the chloride diffusivity, experiment test were carried out and a power function used to describe this influence is proposed.

A Study on the Evaluation Method of Fatigue Strength of Membrane Type LNG Tank(I) (멤브레인 방식 LNG탱크의 피로강도 평가법에 관한 연구 (I))

  • 김종호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.21 no.1
    • /
    • pp.49-58
    • /
    • 1997
  • The membrane type LNG tank is non self-supporting tank which consists of both primary and secondary membrane supported through the insulation boxes by the adjacent hull struc¬ture. Although the membranes are not structural member. They are subject to periodical cyclic loads due to the thermal expansion and other expansions or contraction of membrane. At the design stage of the tank, an analytical and experimental approach on the fatigue strengths of membrane and its welds is necessary in order to assist the designer and the inpector. In this study the evaluation method of fatigue strength of membrane type LNG tank is pre¬sented with FEM analysis and fatigue test of lap welds and it contains the following:1) The fatigue tests and preparation of design S - N curve for lap welds 2) FEM analysis of test specimens 3) Estimation of cumulative damage factor of lap welds 4) Guideline for inspection of lap welds of membrane type LNG tank As the results of analytical and experimental approaches in this study, the evaluation method of fatigue strengths of membrane type LNG tank is proposed, which is expected to be useful for design and inspection of membrane type LNG tank.

  • PDF

A Study on the Repair Welding Methods for Cylinder Block of Diesel Engines (디젤기관 실린더 블록의 보수용접법에 관한연구)

  • 김종호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.3
    • /
    • pp.331-337
    • /
    • 1999
  • Cracks on the cylinder block of diesel engines will often happen due to cyclic load and thermal stress. According to the Classification Societies' rules welding reparis of cylinder block made of cast irons are generally not permitted. However such welding repairs became inevitable taking enormous cost and time for their renewal into consideration. In this study repair welding methods for the clinder blocks made of gray cast irons were reviewed and the tests of their welds were carried out in order to purpose the repair welding meth-ods of packing seat and o-ring seat of cylinder block and apply them to the practice. The following conclusions are botained :1 The tensile strength of weld of cast iron more than that of base metal can be obtained by means of preheating keeping temperature above $100^{\circ}C$ between welding pass-es preventing slag inclusion peening and cramping weld metal by studs. 2. The suspected crack by a magnetic particle test due to different magnetic permeability can be identified which are not associated with a mechanical discotinuity.

  • PDF

Effect of the Heat treatment and Boron on the Hot Corrosion Resistance of the Al Diffusion Coating (Al 확산피복층의 고온 내식성에 미치는 후열처리와 B첨가의 영향)

  • 김태원;윤재홍;이재현;김현수;변응선
    • Journal of the Korean institute of surface engineering
    • /
    • v.32 no.1
    • /
    • pp.67-77
    • /
    • 1999
  • The Ni base superalloy Mar-M247 substrate was aluminized or aluminized after boronizing by the pack cementation under Ar atmosphere. The hot corrosion resistance and after-heat-treatment effect of aluminized specimens were studied by the cyclic hot corrosion test in $Na_2SO_4$-NaCl molten salt. XRD analysis showed that the $Ni_2Al_3$ phase was formed between the coated layer and substrate below 1273K but the NiAl phase above 1273K. The peak of the NiAl phase was developed after heat treatment. Corrosion test showed that corrosion resistance of the specimen with the NiAl phase was better than that with the $Ni_2Al_3$ phase. Corrosion resistance could be improved by heat treatment to form ductile NiAl phase, where cracks were not formed by thermal shock on coating layer. Moreover, it appeared that heat treatment played a role to improve corrosion resistance of Al diffusion coating above 1273K. The existence of boron in the Al diffusion coating layer obstructed outwared diffusion of Cr from the substrate, and it influenced on corrosion resistance of the coating layer by weakening adherence of the oxide scale.