• Title/Summary/Keyword: Thermal Contact

Search Result 1,208, Processing Time 0.025 seconds

Improvement of Carbon Dioxide Reduction Efficiency of Titanium Dioxide Photocatalyst Using 1-propanol (1-propanol 첨가에 따른 이산화타이타늄(TiO2) 광 촉매의 비표면적 향상 및 이산화탄소 환원 효율 향상)

  • Ha, Yuntae;Kwon, JinBeom;An, Heekyung;Jung, Daewoong
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.5
    • /
    • pp.343-347
    • /
    • 2022
  • Recently, the problem of global warming caused by greenhouse gases is getting serious due to the development of industry and the increase in transportation means. Accordingly, the need for a technology to reduce carbon dioxide, which accounts for most of the greenhouse gas, is increasing. Among them, a catalyst for converting carbon dioxide into fuel is being actively studied. Catalysts for reducing carbon dioxide are classified into thermal catalysts and photocatalysts. In particular, the photocatalyst has the advantage that carbon dioxide can be reduced only by irradiating ultraviolet rays at room temperature without high temperature or additional gas. TiO2 is widely used as a photocatalyst because it is non-toxic and has high stability, but has a disadvantage of low carbon dioxide reduction efficiency. To increase the reduction efficiency, 1-propanol was used in the synthesis process. This prevents agglomeration of the catalyst and increases the specific surface area and pores of TiO2, thereby increasing the surface area in contact with carbon dioxide. As a result of measuring the CO2 reduction efficiency, it was confirmed that the efficiency of TiO2 with 1-propanol and TiO2 without 1-propanol was 19% and 12.3%, respectively, and the former showed a 1.5 times improved efficiency.

Effect of Ball Milling Conditions on the Microstructure and Dehydrogenation Behavior of TiH2 Powder (볼 밀링 조건이 TiH2 분말의 미세조직과 탈수소화 거동에 미치는 영향)

  • Ji Young Kim;Eui Seon Lee;Ji Won Choi;Youngmin Kim;Sung-Tag Oh
    • Journal of Powder Materials
    • /
    • v.31 no.2
    • /
    • pp.132-136
    • /
    • 2024
  • This study investigated the effects of revolution speed and ball size in planetary milling on the microstructure and dehydrogenation behavior of TiH2 powder. The particle size analysis showed that the large particles present in the raw powder were effectively refined as the revolution speed increased, and when milled at 500 rpm, the median particle size was 1.47 ㎛. Milling with a mixture of balls of two or three sizes was more effective in refining the raw powder than milling with balls of a single size. A mixture of 3 mm and 5 mm diameter balls was the optimal condition for particle refinement, and the measured median particle size was 0.71 ㎛. The dependence of particle size on revolution speed and ball size was explained by changes in input energy and the number of contact points of the balls. In the milled powder, the endothermic peak measured using differential thermal analysis was observed at a relatively low temperature. This finding was interpreted as the activation of a dehydrogenation reaction, mainly due to the increase in the specific surface area and the concentration of lattice defects.

Numerical and experimental analysis on the axial compression performance of T-shaped concrete-filled thin-walled steel

  • Xuetao Lyu;Weiwei Wang;Huan Li;Jiehong Li;Yang Yu
    • Steel and Composite Structures
    • /
    • v.50 no.4
    • /
    • pp.383-401
    • /
    • 2024
  • The research comprehensively studies the axial compression performance of T-shaped concrete-filled thin-walled steel tubular (CTST) long columns after fire exposure. Initially, a series of tests investigate the effects of heating time, load eccentricity, and stiffeners on the column's performance. Furthermore, Finite Element (FE) analysis is employed to establish temperature and mechanical field models for the T-shaped CTST long column with stiffeners after fire exposure, using carefully determined key parameters such as thermal parameters, constitutive relations, and contact models. In addition, a parametric analysis based on the numerical models is conducted to explore the effects of heating time, section diameter, material strength, and steel ratio on the axial compressive bearing capacity, bending bearing capacity under normal temperature, as well as residual bearing capacity after fire exposure. The results reveal that the maximum lateral deformation occurs near the middle of the span, with bending increasing as heating time and eccentricity rise. Despite a decrease in axial compressive load and bending capacity after fire exposure, the columns still exhibit desirable bearing capacity and deformability. Moreover, the obtained FE results align closely with experimental findings, validating the reliability of the developed numerical models. Additionally, this study proposes a simplified design method to calculate these mechanical property parameters, satisfying the ISO-834 standard. The relative errors between the proposed simplified formulas and FE models remain within 10%, indicating their capability to provide a theoretical reference for practical engineering applications.

Overview of separate effect and integral system tests on the passive containment cooling system of SMART100

  • Jin-Hwa Yang;Tae-Hwan Ahn;Hong Hyun Son;Jin Su Kwon;Hwang Bae;Hyun-Sik Park;Kyoung-Ho Kang
    • Nuclear Engineering and Technology
    • /
    • v.56 no.3
    • /
    • pp.1066-1080
    • /
    • 2024
  • SMART100 has a containment pressure and radioactivity suppression system (CPRSS) for passive containment cooling system (PCCS). This prevents overheating and over-pressurization of a containment through direct contact condensation in an in-containment refueling water storage tank (IRWST) and wall condensation in a CPRSS heat exchanger (CHX) in an emergency cool-down tank (ECT). The Korea Atomic Energy Research Institute (KAERI) constructed scaled-down test facilities, SISTA1 and SISTA2, for the thermal-hydraulic validation of the SMART100 CPRSS. Three separate effect tests were performed using SISTA1 to confirm the heat removal characteristics of SMART100 CPRSS. When the low mass flux steam with or without non-condensable gas is released into an IRWST, the conditions for mitigation of the chugging phenomenon were identified, and the physical variables were quantified by the 3D reconstruction method. The local behavior of the non-condensable gas was measured after condensation inside heat exchanger using a traverse system. Stratification of non-condensable gas occurred in large tank of the natural circulation loop. SISTA2 was used to simulate a small break loss-of-coolant accident (SBLCOA) transient. Since the test apparatus was a metal tank, compensations of initial heat transfer to the material and effect of heat loss during long-term operation were important for simulating cooling performance of SMART100 CPRSS. The pressure of SMART100 CPRSS was maintained below the design limit for 3 days even under sufficiently conservative conditions of an SBLOCA transient.

Thermographic Assessment in Dry Eye Syndrome, Compared with Normal Eyes by Using Thermography (열화상카메라를 이용한 정상안과 건성안의 서모그래피 비교)

  • Park, Chang Won;Lee, Ok Jin;Lee, Seung Won
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.247-253
    • /
    • 2015
  • Purpose: The purpose of this study was to compare and analyze the ocular surface and the palpebral conjunctiva of categorized subjects, which were divided into normal eye group and dry eye group, by using a thermal camera. Methods: Subjects were 144 eyes of 72 normal university students, who didn't have any corneal disease, abnormal lacrimal ducts, medical records regarding ocular surgeries, or experience of using contact lens. Subjects were divided into two groups, which were normal eye group and dry eye group, based on the results of TBUT, Schirmer I test, and McMonnies test. After categorizing the subjects, the temperature of the subjects' ocular surface and the palpebral conjunctiva were measured and analyzed by using a thermal camera (Cox CX series, Answer co., Korea). Results: In the normal eye group's Central Ar.1, Nasal Ar.2, Temporal Ar.3, Superior Ar.4, Inferior Ar.5, the measured amount of temperature change on each area was $-0.13{\pm}0.08$, $-0.14{\pm}0.08$, $-0.12{\pm}0.08$, $-0.14{\pm}0.08$, $-0.10{\pm}0.09(^{\circ}C/sec)$. The dry eye group's results were $-0.17{\pm}0.08$, $-0.16{\pm}0.07$, $-0.16{\pm}0.08$, $-0.17{\pm}0.09$, $-0.15{\pm}0.08(^{\circ}C/sec)$. When compared with the normal eye group, the values of Ar.1, Ar.3, Ar.5 were significantly different in the dry eye group(p<0.05). The amount of temperature change, which was observed on the palpebral conjunctiva(Ar.1:central, Ar.2: nasal, Ar.3: temporal) of the normal eyes, measured by thermography, was $34.36{\pm}1.12$, $34.17{\pm}1.10$, $34.07{\pm}1.12^{\circ}C$ on each area. Same values taken from the dry eye group was $33.55{\pm}0.94$, $33.43{\pm}0.97$, $33.51{\pm}1.06^{\circ}C$ on each area. The values of Ar.1, taken from the dry eye group, had a significant difference, compared to the values of the normal eye group(p=0.05). Conclusion: The temperature of the ocular surface decreased faster on the dry eyes, compared to the normal eyes. The temperature measured on the palpebral conjunctiva of the dry eyes were also lower than the normal eyes. The temperature changes on the ocular surface, observed with a thermal camera, were objective values to assess the stability of tear films, and might provide useful data for studies related to dry eye syndrome.

Thermal Environments of Children's Parks during Heat Wave Period (폭염 시 어린이공원의 온열환경)

  • Ryu, Nam-Hyong;Lee, Chun-Seok
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.44 no.6
    • /
    • pp.84-97
    • /
    • 2016
  • This study was to investigate the user's thermal environments of the children's parks according to pavements and sunscreen types during periods of heat waves. The measurements were conducted at the sand pits, rubber chip pavement, shelters, and green shade ground of the two children's parks located in Jinju, Korea(Chilam: $N\;35^{\circ}11^{\prime}1.4{^{\prime}^{\prim}}$, $E\;128^{\circ}5^{\prime}31.7{^{\prime}^{\prime}}$, elevation 38m, Gaho: $N\;35^{\circ}09^{\prime}56.8{^{\prime}^{\prime}}$, $E\;128^{\circ}6^{\prime}41.1{^{\prime}^{\prime}}$, elevation 24m) over three days during 11-13, August, 2016. The highest ambient air temperatures at the Jinju Meteorological Office during the three measurement days were $35.9{\sim}36.8^{\circ}C$, which corresponded with the extremely hot weather. A series of experiments measured air temperature, relative humidity, wind velocity, black globe temperature, and long-wave and short-wave radiation of the six directions 0.6 m above ground level. The wet bulb globe temperature(WBGT) and the universal thermal climatic index(UTCI) were used to evaluate thermal stress. Surface temperature images of the play equipment were also taken using infrared thermography. Surface temperatures of the play equipment and grounds were used to evaluate burn risk through contact with playground materials. The results showed the following. The maximum air temperatures averaged over 1-hour period for three days were $36.6{\sim}39.4^{\circ}C$. The sun shades reduced those temperatures by up to $2.8^{\circ}C$(green shade) and $1.0^{\circ}C/2.3^{\circ}C$(shelters). The minimum relative humidity values averaged over 1-hour period for three days were 44~50%. The sun shades increased those humidity values by up to 6%(green shade) and 4%/6%(shelters). The risk of heat related illness at the measurement sites of the children's parks were extreme and high in the daytime hours. The maximum WBGT values averaged over a 30-minute period for three days were $31.2{\sim}33.6^{\circ}C$. The sun shades reduced those WBGT values by up to $2.4^{\circ}C$(green shade) and $0.5^{\circ}C/2.1^{\circ}C$(shelters) compared to sandpits, but would not block the risk of heat related illness in the daytime hours. The category of heat stress at the measurement sites of the children's parks were extreme and very strong in the daytime hours. The maximum UTCI values averaged over a 30-minute period for three days were $39.9{\sim}48.1^{\circ}C$. The sun shades reduced those UTCI values by up to $7.8^{\circ}C$(green shade) and $4.1^{\circ}C/8.2^{\circ}C$(shelters) compared to sandpits, but could not lower heat stress category from extreme and very strong to strong and moderate in the daytime hours. According to the burn threshold criteria when skin was in contact with playground materials, the maximum surface temperature of the stainless steels($70.8^{\circ}C$) surpassed three seconds $60^{\circ}C$ threshold for uncoated steel, that of the rubber chip($76.5^{\circ}C$) surpassed five seconds $74^{\circ}C$ threshold for the plastic, that of the plastic slide($68.5^{\circ}C$) and seats($71.0^{\circ}C$) surpassed the one min $60^{\circ}C$ threshold for plastic, respectively. The surface temperatures of shaded play equipment were lower approximately $20^{\circ}C$ than those of play equipment exposed to the sun. Therefore, sun shades can block the risk of burns in daytime hours. Because of the extreme and high risk of heat related illness and extreme and high heat stress at the children's parks during periods of heat waves, parents and administrators must protect children from the use of playgrounds. The risk of burn when contact with play equipments and grounds at the children's parks during periods of heat waves, was very high. The sun shades are essential to block the risk of burn from play equipments and grounds at the children's parks during heat waves.

The Development of an Electroconductive SiC-ZrB2 Composite through Spark Plasma Sintering under Argon Atmosphere

  • Lee, Jung-Hoon;Ju, Jin-Young;Kim, Cheol-Ho;Park, Jin-Hyoung;Lee, Hee-Seung;Shin, Yong-Deok
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.342-351
    • /
    • 2010
  • The SiC-$ZrB_2$ composites were fabricated by combining 30, 35, 40, 45 and 50 vol. % of zirconium diboride ($ZrB_2$) powders with silicon carbide (SiC) matrix. The SiC-$ZrB_2$ composites and the sintered compacts were produced through spark plasma sintering (SPS) under argon atmosphere, and its physical, electrical, and mechanical properties were examined. Also, the thermal image analysis of the SiC-$ZrB_2$ composites was examined. Reactions between $\beta$-SiC and $ZrB_2$ were not observed via x-ray diffraction (XRD) analysis. The apparent porosity of the SiC+30vol.%$ZrB_2$, SiC+35vol.%$ZrB_2$, SiC+40vol.%$ZrB_2$, SiC+45vol.%$ZrB_2$ and SiC+50vol.%$ZrB_2$ composites were 7.2546, 0.8920, 0.6038, 1.0981, and 10.0108%, respectively. The XRD phase analysis of the sintered compacts demonstrated a high phase of SiC and $ZrB_2$. Among the $SiC+ZrB_2$ composites, the SiC+50vol.%$ZrB_2$ composite had the lowest flexural strength, 290.54MPa, the other composites had more than 980MPa flexural strength except the SiC+30vol.%$ZrB_2$ composite; the SiC+40vol.%$ZrB_2$ composite had the highest flexural strength, 1011.34MPa, at room temperature. The electrical properties of the SiC-$ZrB_2$ composites had positive temperature coefficient resistance (PTCR). The V-I characteristics of the SiC-$ZrB_2$ composites had a linear shape in the temperature range from room to $500^{\circ}C$. The electrical resistivities of the SiC+30vol.%$ZrB_2$, SiC+35vol.%$ZrB_2$, SiC+40vol.%$ZrB_2$ SiC+45vol.%$ZrB_2$ and SiC+50vol.%$ZrB_2$ composites were $4.573\times10^{-3}$, $1.554\times10^{-3}$, $9.365\times10^{-4}$, $6.999\times10^{-4}$, and $6.069\times10^{-4}\Omega{\cdot}cm$, respectively, at room temperature, and their resistance temperature coefficients were $1.896\times10^{-3}$, $3.064\times10^{-3}$, $3.169\times10^{-3}$, $3.097\times10^{-3}$, and $3.418\times10^{-3}/^{\circ}C$ in the temperature range from room to $500^{\circ}C$, respectively. Therefore, it is considered that among the sintered compacts the SiC+35vol.%$ZrB_2$, SiC+40vol.%$ZrB_2$ and SiC+45vol.%$ZrB_2$ composites containing the most outstanding mechanical properties as well as PTCR and V-I characteristics can be used as an energy friendly ceramic heater or ohmic-contact electrode material through SPS.

Perfluoropolymer Membranes of Tetrafluoroethylene and 2,2,4Trifluofo- 5Trifluorometoxy- 1,3Dioxole.

  • Arcella, V.;Colaianna, P.;Brinati, G.;Gordano, A.;Clarizia, G.;Tocci, E.;Drioli, E.
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1999.07a
    • /
    • pp.39-42
    • /
    • 1999
  • Perfluoropolymers represent the ultimate resistance to hostile chemical environments and high service temperature, attributed to the presence of fluorine in the polymer backbone, i.e. to the high bond energy of C-F and C-C bonds of fluorocarbons. Copolymers of Tetrafluoroethylene (TEE) and 2, 2, 4Trifluoro-5Trifluorometoxy- 1, 3Dioxole (TTD), commercially known as HYFLON AD, are amorphous perfluoropolymers with glass transition temperature (Tg)higher than room temperature, showing a thermal decomposition temperature exceeding 40$0^{\circ}C$. These polymer systems are highly soluble in fluorinated solvents, with low solution viscosities. This property allows the preparation of self-supported and composite membranes with desired membrane thickness. Symmetric and asymmetric perfluoropolymer membranes, made with HYFLON AD, have been prepared and evaluated. Porous and not porous symmetric membranes have been obtained by solvent evaporation with various processing conditions. Asymmetric membranes have been prepared by th wet phase inversion method. Measure of contact angle to distilled water have been carried out. Figure 1 compares experimental results with those of other commercial membranes. Contact angles of about 120$^{\circ}$for our amorphous perfluoropolymer membranes demonstrate that they posses a high hydrophobic character. Measure of contact angles to hexandecane have been also carried out to evaluate the organophobic character. Rsults are reported in Figure 2. The observed strong organophobicity leads to excellent fouling resistance and inertness. Porous membranes with pore size between 30 and 80 nanometers have shown no permeation to water at pressures as high as 10 bars. However high permeation to gases, such as O2, N2 and CO2, and no selectivities were observed. Considering the porous structure of the membrane, this behavior was expected. In consideration of the above properties, possible useful uses in th field of gas- liquid separations are envisaged for these membranes. A particularly promising application is in the field of membrane contactors, equipments in which membranes are used to improve mass transfer coefficients in respect to traditional extraction and absorption processes. Gas permeation properties have been evaluated for asymmetric membranes and composite symmetric ones. Experimental permselectivity values, obtained at different pressure differences, to various single gases are reported in Tab. 1, 2 and 3. Experimental data have been compared with literature data obtained with membranes made with different amorphous perfluoropolymer systems, such as copolymers of Perfluoro2, 2dimethyl dioxole (PDD) and Tetrafluorethylene, commercialized by the Du Pont Company with the trade name of Teflon AF. An interesting linear relationship between permeability and the glass transition temperature of the polymer constituting the membrane has been observed. Results are descussed in terms of polymer chain structure, which affects the presence of voids at molecular scale and their size distribution. Molecular Dyanmics studies are in progress in order to support the understanding of these results. A modified Theodoru- Suter method provided by the Amorphous Cell module of InsightII/Discover was used to determine the chain packing. A completely amorphous polymer box of about 3.5 nm was considered. Last but not least the use of amorphous perfluoropolymer membranes appears to be ideal when separation processes have to be performed in hostile environments, i.e. high temperatures and aggressive non-aqueous media, such as chemicals and solvents. In these cases Hyflon AD membranes can exploit the outstanding resistance of perfluoropolymers.

  • PDF

Thermographic Assessment on Temperature Change of Eye Surface in Cataract Surgery Observation (백내장수술 안에서 열화상카메라를 이용한 안구표면 온도의 변화)

  • Park, Chang Won;An, Young-Ju;Kim, Hyojin
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.497-504
    • /
    • 2018
  • Purpose : The purpose of this study was to investigate the temperature changes of the ocular surface before and after cataract surgery using thermography of a thermal imaging camera. Methods : The study included 75 patients (75 eyes) aged from 50 to 79 years who underwent cataract surgery. In the past, those who underwent corneal-related surgery, wearing contact lens, disorder of tear secretion and taking medication for systemic disease were excluded from this study. The temperature changes of the eyeball surface were measured using a thermal imager (Cox CX series, Answer, Korea) following Tear Break Up Time (TBUT) test, Mcmonnies questionnaire and Schirmer's Test in real time, Results : While the temperature of preoperative ocular surface was $35.20{\pm}0.54^{\circ}C$ and that of postoperative temperature was $35.30{\pm}0.53^{\circ}C$, the difference was not significant. The temperature changes in the ocular surface were statistically significant at $-0.12{\pm}0.08{\Delta}$ ($^{\circ}C/sec$) before the surgery and $-0.18{\pm}0.07{\Delta}$ ($^{\circ}C/sec$) after the surgery. In comparison of the age groups, it was shown that the changes in the surface temperature before the surgery were from $-0.19{\pm}0.05{\Delta}$ ($^{\circ}C/sec$) to $-0.14{\pm}0.09{\Delta}$ ($^{\circ}C/sec$) in the 50s group, and from $-0.12{\pm}0.08{\Delta}$ ($^{\circ}C/sec$) to $-0.15{\pm}0.07{\Delta}$ ($^{\circ}C/sec$) in 60s group, and $-0.18{\pm}0.07{\Delta}$ ($^{\circ}C$) to $-0.12{\pm}0.08{\Delta}/sec$) in the 70s group, showing significant changes in the ocular surface temperature at all ages. Conclusion : Following the cataract surgery, all the indicators of dry eye syndrome were decreased, and eye surface temperature changes were significant. The thermography technique of the ocular surface would be expected to be useful for the evaluation of various dry eye syndromes because it is easy to evaluate dry eye syndrome noninvasively and can be quantified.

The Fabrication of $n^+-p^+$ InP Solar Cells by the Diffusion of Sulphur (S확산에 의한 $n^+-p^+$ InP 태양전지의 제작)

  • Jung, Ki-Ung;Kim, Seon-Tai;Moon, Dong-Chan
    • Solar Energy
    • /
    • v.10 no.3
    • /
    • pp.60-65
    • /
    • 1990
  • [ $n^+-p^+$ ] InP homojunction solar cells were fabricated by thermal diffusion of sulphur into a $p^+$-InP wafer($p=4{\times}10^{18}cm^{-3}$), and a SiO film($600{\AA}$ thick) was coated on the $n^+$ layer as an antireflection(AR) coating by an e-beam evaporator. The volume of the cells were $5{\times}5{\times}0.3mm^3$. The front contact grids of the cells with 16 finger pattern of which width and space were $20{\mu}m$ and $300{\mu}m$ respectively, were formed by photo-lithography technique. The junction depth of sulphur were as shallow as about 0.4r m We found out the fabricated solar cells that, with increasing the diffusion time, short circuit current densities($J_{sc}$), series resistances($R_s$) and energy conversion efficiencies(${\eta}$) were increased. The cells show good spectral responses in the region of $5,000-9,000{\AA}$. The short circuit current density, the open circuit voltage( $V_{oc}$), the fill factor(F.F) and the energy conversion efficiency of the cell were $13.16mA/cm^2$, 0.38V, 53.74% and 10.1% respectively.

  • PDF