• 제목/요약/키워드: Thermal Comfort Condition

검색결과 131건 처리시간 0.03초

전남지방 전통주택의 하절기 온습도 측정 및 주관평가에 관한 실험적 연구 (An Experimental Study on the Thermal Environmental Measurements and Subjective Reponses in Summer Season for the Korean Traditional Houses in Chonnam Province)

  • 김선우;이태강;김형렬
    • 한국주거학회논문집
    • /
    • 제17권2호
    • /
    • pp.41-46
    • /
    • 2006
  • This study aims to analyzed thermal comfort characteristics and subject response for thermal environment of Korean traditional houses.. The air temperature and humidity in the living area of the residence were measured in during a day. And the subject response were surveyed to evaluate of controling the thermal environment factor (temperature, humidity, comfort) of the korean traditional houses. As a result, the variation of air temperature and humidity of most rooms are considerably static while condition of outdoors are much varied, it is showed that indoor climate has been controled with traditional soiled walls. And environmental control for the air temperature and humidity is estimated considerably satisfactory.

바닥면복사난방에서 Draft에 의한 쾌적열환경에 관한 연구 (A study on the comfort thermal environment by the Draft in floor panel heating system)

  • 이경희
    • 한국주거학회논문집
    • /
    • 제7권2호
    • /
    • pp.121-129
    • /
    • 1996
  • This study was to estimate how about various effects on the body thermal sensation as air velocity. clo. mean radiant temperature and resultant temperature are varied. The indoor thermal environment elements are measured under the five different of air velocity. Using the above considerations. the following results are obtained. ▶ The states, the air velocity under 0.5 m/s and 0.63 to 0.9 clo. were shown that the comfort zone of mean radiant temperature by 21.2~24.7C, the neutral point by 22.8C, the resultant temperature by 20.7-24.4C and the neutral point by 22.6C. ▶ On equal condition, the draft was occurred at a given air-velocity under 0.5m.s. It was also appeared the floor panel heating system affecting the body thermal sensation by the subject’s below-chest parts and the local discomfort by sensations on the feet and the knees.

  • PDF

공동주택의 하절기 자연환기 시 지붕면 일사수열이 최상층 실내온열환경에 미치는 영향 분석 (Analysis of the Irradiated Solar Heat Effect on Indoor Thermal Environment of the Top Floor Units of Apartment Houses in the Summer - On Condition that All Openings of the Units are Opened -)

  • 최동호
    • 한국태양에너지학회 논문집
    • /
    • 제25권1호
    • /
    • pp.45-55
    • /
    • 2005
  • In the summer, the irradiated solar heat gain through the roof has an effect on the thermal environment of the top floor units of apartment houses. This paper investigated the differences of the indoor air temperature, globe temperature and thermal comfort index between the top floor unit and the middle floor unit by measuring them at the sample units on the condition that all the openings of the units are opened. The purpose of this paper is to provide quantitative data about the irradiated solar heat gain during the summertime through the roof of an apartment house and these data to be the source to reevaluate the appropriate roof insulation efficiency. From this study, we obtained three brief results as follows. Indoor air temperature difference between the two sample units shifts a day. Indoor air temperature at the top floor unit is $0{\sim}1.8^{\circ}C$ higher than that of the middle floor unit from 12:00 p.m. to 12:00 a.m. and $0{\sim}2.8^{\circ}C$ lower from 12:00 a.m. to 12:00 p.m. The evaluation of the indoor thermal comfort index and the globe temperature shows similar results as the indoor air temperature measuring. Results of this experiment verified the actual existence of indoor air temperature difference between the top floor unit and the middle one and this difference comes from the heat storage of the roof.

선실의 온열환경을 고려한 선박의 냉난방 시스템 설계 기법 (Thermal Environment-based HVAC Operating Design in Cabins on Naval Ships)

  • 장미숙;고창두;문일성;이춘주;김상현
    • 대한조선학회논문집
    • /
    • 제42권4호
    • /
    • pp.402-410
    • /
    • 2005
  • This paper focused on the analysis of the thermal comfort conditions in 1,000 ton class patrol ship's cabins through the evaluation of PMV(predicted mean vote) and PPD(predicted percentage of dissatisfied). Different areas have different clothing and activity in the ship. Therefore, any area may be thermally uncomfortable in case of air conditioning with equal temperature, relative humidity and relative air velocity. PMV or PPD-DCAC (demand controlled air conditioning) system is a new design that the whole cabins are maintainable with the ideal thermal comfort condition.

두개의 제어기를 사용한 건물 내부의 온도변화와 에너지소비량을 계산하기 위한 해석적 연구 (A study on the analytical method for calculating the inside air temperature transient and energy consumption load of the building using two different controllers)

  • 한규일
    • 수산해양기술연구
    • /
    • 제48권1호
    • /
    • pp.82-90
    • /
    • 2012
  • Four different buildings having various wall construction are analyzed for the effect of wall mass on the thermal performance and inside building air and wall temperature transient and also for calculating the energy consumption load. This analytical study was motivated by the experimental work of Burch et al. An analytical solution of one-dimensional, linear, partial differential equations is obtained using the Laplace transform method, Bromwich and modified Bromwich contour method. A simple dynamic model using steady state analysis as simplified methods is developed and results of energy consumption loads are compared with results obtained using the analytical solution. Typical Meteorological Year data are processed to yield hourly average monthly values. This study is conducted using weather data from two different locations in Korea: Daegu having severe weather in summer and winter and Jeju having mild weather almost all year round. There is a significant wall mass effect on the thermal performance of a building in mild weather condition. Buildings of heavyweight construction with insulation show the highest comfort level in mild weather condition. A proportional controller provides the higher comfort level in comparison with buildings using on-off controller. The steady state analysis gives an accurate estimate of energy load for all types of construction. Finally, it appears that both mass and wall insulation are important factors in the thermal performance of buildings, but their relative merits should be decided in each building by a strict analysis of the building layout, weather conditions and site condition.

축열/체열반사기능을 가진 스포츠 레저복의 온열쾌적성 - 0±1℃, 50±5% RH 환경에서의 착의평가 - (Thermal Comfort of the Sports/Leisure Clothing with the Heat Storage/Reflection Function - Wearing Evaluation under the Condition of 0x00B1;1℃ and 50±5% RH -)

  • 김태규;송민규;이창민;권오경
    • 한국의류산업학회지
    • /
    • 제20권4호
    • /
    • pp.474-481
    • /
    • 2018
  • For this study, we developed clothing in which textile materials that were excellent weather control function for the cold environment and we performed the human subject test with developed clothing to determine the thermal comfort. We used 2 clothing samples developed (A and B, hollow yarn+moisture absorption/quick drying yarn, 3 layers, high stretchable, heat reflection film and lamination treated) and a control sample (Ctrl.) for the human subject test and 8 adult males were used as a human subjects and environmental conditions of chamber were $0{\pm}1^{\circ}C$. $50{\pm}5%RH$, 0.3m/sec. The results were as follows: The average skin temperature and hand, thigh temperature of B were higher than B and Ctrl. (p<.05). The micro-climates of B were near to thermal comfort range which is $32{\pm}1^{\circ}C$ and $50{\pm}10%\;RH$. The chest temperature of B was significantly higher than others (p<.05). The relative humidity of B was lower than others and kept stable rather than others. The thermal sensation of B was near the "neutral" and was significantly different from Ctrl. (p<.01) and the weight loss of B was lower than Ctrl. (p<.05). The counting task and hand temperature was positively related and the counting task value of B and A is bigger than Ctrl. and that of A was bigger than Ctrl. (p<.05).

서열 환경에서 농작업 모자 착용에 따른 체온 조절 및 주관적 반응 (Thermal and subjective responses by sun hats for farmer in a hot climatic chamber)

  • 김명주;최정화
    • 한국의류학회지
    • /
    • 제28권5호
    • /
    • pp.713-722
    • /
    • 2004
  • This study examined the effects of two kinds of functional sun hats through a head-manikin test and a climatic chamber trial for farm workers in summer. Experiment was composed of four conditions. The first condition was the condition without any hat (Control). The second was the condition with a sun hat on the market (Hat A). The third was the condition with a functional sun hat made of reflective fabric (Hat B). The last was the condition with a functional sun hat having a ventilating structure as well as reflective fabric (Hat C). For the subjects in the climatic chamber trials, 12 healthy males volunteered. Air temperature, relative humidity and globe temperature in the chamber was maintained at $33{\pm}0.5^{\circ}C,\;65{\pm}5%RH\;and\;39{\pm}1^{\circ}C\;(WBGT\;33^{\circ}C)$. Subjects did a simulated red pepper-work (50-min work and 10-min rest, twice repetition) for 120 min. As the result of head-manikin test, the surface temperature on middle of back-neck was the lowest in Hat B of four conditions and the surface temperature on top of head was the lowest in Hat C. As the result of climatic chamber trials, there were apparent differences between with (Hat A, Hat B, Hat C) and without a sun hat (Control). In rectal temperature ($T_{re}$), mean skin temperature ($\={T}_{sk}$), heart rate (HR), total sweat rate (TSR), The physiological heat strain was less in the condition with hats than in the condition without a sun hat. As the increasing rate in Tre, Hat B is the most effective hat for alleviation heat strain. As the subjective responses, Hat B was the most effective hat for thermal comfort even though the difference was not significant. Hat C was less effective than Hat B and the reason might be the increase of weight due to inserting the ventilating structure.

생태 공간 조성에 관한 기초 연구 -고령자를 대상으로 한 열환경 연구- (Basic Study on Creating Ecological Residence Space - A thermal environment study of the aged -)

  • 김동규;하병용;금종수;정용현
    • 수산해양교육연구
    • /
    • 제23권2호
    • /
    • pp.153-161
    • /
    • 2011
  • Creating standards on thermal environment has been organized traditionally based on the youth and the manhood who are in mainly active layer of a society. However, traditional creating standards have differences from the physiology of the aged who have weak physical ability than younger person. As a result, it causes a health problem of the aged. Therefore, In this study, we had a basic study to create a comfortable thermal environment which had considered to a physical ability and a physiology of the aged, and build a ecological residence space to maintain health. We had several experiments with the aged; Experiment, Comfort Sensation Vote, Mean Skin Temperature and Analyzing HRV. The result have following by: 1)For the aged, the summer recommend temperature, $26^{\circ}C$, is appropriate within first 30 ~ 40 minutes, but it should be increasing the temperature after that time. 2) By considering PMV status and thermal feeling of the aged, they are prefer to higher temperature than normal setting of air-condition system. 3) In the condition of the summer recommend temperature, $26^{\circ}C$, they had answered in neutral or comfort with the comfort sensation vote. However, we had figure out that they had stress in a lower temperature by analyzing the result of HRV.

대형 크루저 선실의 동절기 온열환경 측정평가 (A Measurement and Evaluation on the Cabins' Thermal Conditions of Large Cruiser in the Winter)

  • 황광일;문태일;박민강;심재건
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.231-232
    • /
    • 2006
  • The purpose of this study is to measure and evaluate the thermal conditions of large cruiser's cabin. As the result of this study, followings are cleared. The air volume supplied to the 2 types of cabins is quite diffenrent. Temperature differences in the Room A which is located A deck and supplied enough air volume is stable all around the cabin. But Room B which is located B deck and supplied comparatively small air volume has temperature distribution problems, like time-dependent differences, vertical differences. To serve more comfort and productivity of Room B, it is strongly recommended to do a T.A.B.(Testing, Adjusting and Balancing) for more air volume and/or to design new air flow path to make air stay longer.

  • PDF

Two-Way 스트레치 직물의 열응력분석 연구 (A Study on the Thermal-Stress Properties of Bi-Elastic Woven Fabrics)

  • 전병익
    • 한국산업융합학회 논문집
    • /
    • 제8권3호
    • /
    • pp.149-154
    • /
    • 2005
  • The purpose of this study was to develop the High Functional Stretch Yarns and Woven Fabrics to produce the high value added textile goods and to meet the consumer's needs. For the study 8 yarns and 10 fabrics were made with three develop machine and the thermal-stress properties of the sample were tested and analysed. The result indicated that the sample fabrics kept their stretch performance regardless of conventional process. EDY(elastic DTY) had higher stretch than that of DTY(drawn textured yarn). Especially Macel yarn had higher stretch than that of DTY compared with the same condition of yarn. With time course behavior the elongation of DTY and EDY had stabled tendency without variation. The above results show that wearing sensation and comfort properties of fabrics are changed depending on the end-use. and thus, above results can be used to manufacture of fabrics for specific end-use with high comfort properties.

  • PDF