• Title/Summary/Keyword: Thermal Bridge

Search Result 297, Processing Time 0.023 seconds

Comparative Performance Evaluation by Winter Apartment Temperature on the Outer Surface of the Insulation (동계 아파트 외표면 온도에 의한 단열성능 비교평가)

  • Park, Jung-Hun;Kim, Bong-Joo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.4
    • /
    • pp.91-100
    • /
    • 2013
  • This research is to measure and analyze the thermal performance of the apartment structure and to evaluate and establish standards of thermal insulation defect in order to make the basic data necessary for determining the degree of the thermal performance degradation and for repairing and reinforcing the exterior wall of the existing apartment. Furthermore, it is to predict the part of occurrence of the thermal bridge and condensation at the apartment building structure. On the other one hand, it is also to analyze the degree of thermal insulation performance according to the standards of thermal insulation and elapsed time, through the analysis by the workability of concrete.

Survey Research on Thermal Situation of Office Buildings (사무소 건축물의 단열상황에 관한 조사연구)

  • Jung, Ui In;Kim, Bong Joo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.3
    • /
    • pp.145-152
    • /
    • 2013
  • This study is to evaluate the thermal insulation of the curtain wall of the buildings constructed since the 1990s to the buildings currently under construction in 2011 and to provide the basic data for repairing and reinforcing and designing the thermal insulation. To this effect, the temperature difference by part was analyzed through measuring the inside and outside surface temperature of the curtain wall of the office building, and thereafter, the conditions of the thermal insulation and the thermal bridge part were examined. The result of the study is as follows; Not only in the winter season when the temperature difference between the indoor-outdoor is over $20^{\circ}C$, but also in the summer season when there is a small temperature difference, the temperature difference between the inside and outside of the frame is $2^{\circ}C{\sim}4^{\circ}C$ equally. Under such conditions as stated above, the thermal bridge occurred, which resulted from the heat flow of the steel frame part (mullion, transom), and therefore, the reinforcement of the thermal insulation is considered to be needed.

A Study on the Behavior of P.C. Box Girder Bridge for Temperature Gradients (온도 구배에 대한 P.C. 상자형 교량의 거동연구)

  • 손기훈;이성우
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1998.10a
    • /
    • pp.159-166
    • /
    • 1998
  • To study temperature effect of P.C. box girder bridge, field measurement was performed for six months, along with thermal analysis for the newly constructed viaduct of Gangbyun Highway in Seoul. Thermocouples were installed inside and surface of the flange and web of the box and temperature of box section md ambient temperature was measured. Measured environmental data are incorporated in finite element thermal analysis and computed temperature of the section was compared with measured one. Temperature gradient from thermal analysis was compared with Korean Highway Specification(1996)and the New Zealand Ministry of Works and Development code(1976). Thermal stress distribution across the box section was also compared.

  • PDF

Temperature Distribution and It's Contribution to Self-equilibrium Thermal Stress in Bridge (교량 단면 내 온도분포에 따른 자체평형 열응력 해석)

  • Kwak, Hyo-Gyoung;Kwon, Se-Hyung;Ha, Sang-Hee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.5
    • /
    • pp.531-542
    • /
    • 2011
  • The time-dependent temperature distribution across the section in bridges is determined on the basis of the three-dimensional finite element analyses and numerical time integration in this study. The material properties which change with time and thermal stress of concrete are taken into account to effectively trace the early-age structural responses. Since the temperature distribution is nonlinear and depends upon many material constants such as the thermal conductivity, specific heat, hydration heat of concrete, heat transfer coefficients and solar radiation, three representative influencing factors of the construction season, wind velocity and bridge pavement are considered at the parametric studies. The validity of the introduced numerical model is established by comparing the analytical predictions with results from previous analytical studies. On the basis of parametric studies for four different bridge sections, it is found that the creep deformation in concrete bridges must be considered to reach more reasonable design results and the temperature distribution proposed in the Korean bridge design specification need to be improved.

A Measurement and Evaluation of the Indoor Thermal Conditions in Summer of a Newly-Launched 8,500GT Chemical Carrier (신조 8,500GT 화학물 운반선의 여름철 선실 내 온열환경 실측평가)

  • Hwang, Kwang-Il;Doe, Geun-Young;Cho, Hyo-Jae;Woo, Sang-Woo;Shin, Dong-Keol;Lim, Seong-Taek
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.5
    • /
    • pp.717-723
    • /
    • 2008
  • The purpose of this study is to measure and analyze the indoor thermal conditions of a 8,500GT class chemical carrier which was launched on July 2007. The measurement was operated from 4th June to 4th June 2007, just before handing over to Owner. Followings are the results of this study. (1)The temperature variations of supply air were related to the outdoor temperature variations, but the humidity was stable at $65{\sim}80%$. (2)The temperature variations at the representative position of bridge, restaurant, crew's cabin showed gentle slopes. but that of conference room was very steepy. The humidities of bridge and restaurant were unstable because of outdoor-contact and cooking, respectively. (4)The temperature and humidity of ECR(Engine Control Room) which was designed to supply heating and cooling by PAC(Package Air Conditioner) were directly affected by the operating conditions of PAC. (5)The measured supply air volume from dampers of bridge, crew's cabin and conference room were satisfied with the design supply air volume. (5)For the improvement of the indoor thermal conditions, the temperature of crew's cabin and restaurant and the humidity of conference room, and the temperature and humidity of bridge should be controlled, respectively.

Thermal-Structure Interaction Parallel Fire Analysis for Steel-Concrete Composite Structures under Bridge Exposed to Fire Loading (화재에 노출된 교량하부 강합성 구조물에 대한 열-구조 연성 병렬화재해석)

  • Yun, Sung-Hwan;Gil, Heungbae;Lee, Ilkeun;Kim, Wooseok;Park, Taehyo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.26 no.4
    • /
    • pp.283-292
    • /
    • 2013
  • The objective of this research is to evaluate of global and local damage for steel-concrete composite structures under highway bridge exposed to fire loading. To enhance the accuracy and efficiency of the numerical analysis, the proposed transient nonlinear thermal structure interaction(TSI) parallel fire analysis method is implemented in ANSYS. To validate the TSI parallel fire analysis method, a comparison is made with the standard fire test results. The proposed TSI parallel fire analysis method is applied to fire damage analysis and performance evaluation for Buchen highway bridge. The result of analysis, temperature of low flange and web are exceed the critical temperature. The deflection and deformation state show good agreement with the fire accident of buchen highway bridge.

Analysis and Measurements of Hydration Heat of Pile Cap in Incheon Bridge (인천대교 파일캡 구조물의 수화열 해석 및 계측)

  • Park, Kyoung-Lae;Yun, Man-Guen;Shin, Hyun-Yang;Kim, Young-Seon;Lee, Kwang-Myung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.421-424
    • /
    • 2006
  • In massive hardening concrete structures, early age thermal cracking due to the heat of hydration may occur. There are many massive structures in Incheon bridge project and they have to be carefully treated to prevent thermal cracking. In this paper, an example of analyzed and measured results of hydration heat of pile caps in the Incheon bridge project was represented. Finite element simulations were carried out before casting and curing method was determined using the analyzed result. Sensors were installed before casting and temperature and strain of concrete was measured during curing. Gathered data were compared with the analyzed data and selected control method to prevent cracking was verified. Analyzed result gave good agreement and very few cracking could be found.

  • PDF

Temperature distribution behaviors of GFRP honeycomb hollow section sandwich panels

  • Kong, B.;Cai, C.S.;Pan, F.
    • Structural Engineering and Mechanics
    • /
    • v.47 no.5
    • /
    • pp.623-641
    • /
    • 2013
  • The fiber-reinforced polymer (FRP) composite panel, with the benefits of light weight, high strength, good corrosion resistance, and long-term durability, has been considered as one of the prosperous alternatives for structural retrofits and replacements. Although with these advantages, a further application of FRPs in bridge engineering may be restricted, and that is partly due to some unsatisfied thermal performance observed in recent studies. In this regard, Kansas Department of Transportation (DOT) conducted a field monitoring program on a bridge with glass FRP (GFRP) honeycomb hollow section sandwich panels. The temperatures of the panel surfaces and ambient air were measured from December 2002 to July 2004. In this paper, the temperature distributing behaviors of the panels are firstly demonstrated and discussed based on the field measurements. Then, a numerical modeling procedure of temperature fields is developed and verified. This model is capable of predicting the temperature distributions with the local environmental conditions and material's thermal properties. Finally, a parametric study is employed to examine the sensitivities of several temperature influencing factors, including the hollow section configurations, environmental conditions, and material properties.

Study on the Cooling Performance of Heatsink for Induction Cooktop using Computational Fluid Dynamics (인덕션 쿡탑 기구물 형상변경이 Heatsink 및 Coil 냉각성능에 미치는 영향에 대한 연구)

  • Park, Dong Ho;Kwon, Myoung Keun;Lee, Dong Beom;Seo, Eung Ryeol;Park, Yong Jong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.3
    • /
    • pp.33-37
    • /
    • 2015
  • A numerical study on the IPM/Bridge Diode cooling and coil cooling has been performed. Results are presented as plots of thermal resistance, temperature drop and RPM-ratio. CFD analysis for conventional cooling system has been performed as a reference case. As the RPM-Ratio was increased, heatsink thermal resistance and coil temperature were decreased. IPM/Bridge Diode thermal resistance and temperature of the coil is tended to be trade-off. The temperature of coil closest to the AC-motor fan showed the most significant change in accordance with duct design. The temperature of coil located at the top of DC-motor fan showed the most significant variation as the cooling air passes the heatsink fin area.