• Title/Summary/Keyword: The weak on disaster

Search Result 101, Processing Time 0.029 seconds

Influence of ventilation rate on the aerodynamic interference between two extra-large indirect dry cooling towers by CFD

  • Ke, S.T.;Liang, J.;Zhao, L.;Ge, Y.J.
    • Wind and Structures
    • /
    • v.20 no.3
    • /
    • pp.449-468
    • /
    • 2015
  • Current wind-resistance designs of large-scale indirect dry cooling towers (IDCTs) exclude an important factor: the influence of the ventilation rate for radiator shutter on wind loads on the outer surfaces of the tower shell. More seemingly overlooked aspects are the effects of various ventilation rates on the wind pressure distribution on the tower surfaces of two IDCTs, and the feature of the flow field around them. In order to investigate the effects of the radiator shutter ventilation rates on the aerodynamic interference between IDCTs, this paper established the numerical wind tunnel model based on the Computational Fluid Dynamic (CFD) technology, and analyzed the influences of various radiator shutter ventilation rates on the aerodynamic loads acting upon a single and two extra-large IDCTs during building, installation, and operation stages. Through the comparison with the results of physical wind tunnel test and different design codes, the results indicated that: the influence of the ventilation rate on the flow field and shape coefficients on the outer surface of a single IDCT is weak, and the curve of mean shape coefficients is close to the reference curve provided by the current design code. In a two-tower combination, the ventilation rate significantly affects the downwind surface of the front tower and the upwind surface of the back tower, and the larger positive pressure shifts down along the upwind surface of the back tower as the ventilation rate increases. The ventilation rate significantly influences the drag force coefficient of the back tower in a two-tower combination, the drag force coefficient increases with the ventilation rate and reaches the maximum in a building status of full ventilation, and the maximum drag coefficient is 11% greater than that with complete closure.

A Comparative Study on the Behavior of High-rise Buildings by 2D and 3D Dynamic Analysis with Considering the Ground (초고층 건물의 지반을 고려한 2D 및 3D 동적해석에 의한 거동 비교 연구)

  • You, Kwangho;Baek, Yong;Kim, Seungjin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.20 no.10
    • /
    • pp.5-14
    • /
    • 2019
  • Recently, earthquakes have occurred in our country and seismic stability of high-rise buildings in large cities is being a growing interest and thus the related studies have been increased. Also the grounds are considered indirectly in most of seismic designs and analyses and seismic researches based on 3D dynamic analysis are insufficient. In this study, therefore, 2D and 3D dynamic analyses were performed based on the SSI complete model including grounds and the behavior was compared and analyzed. For dynamic modeling, linear time history analyses were performed by using MIDAS GTS NX. For this purpose, a high-rise building was assumed to be constructed on top of the bedrock and surrounded by a surface layer. A sensitivity analysis was performed with the selected parameters. The dynamic behavior was compared and analyzed in terms of horizontal displacements, drift ratios, bending stresses, and weak parts. In most cases, 2D dynamic behavior was calculated to be larger than 3D's and thus it shows more conservative results with increasing number and size of weak parts.

The Characteristic of the Disasters caused by Typhoons passing through the Sea Area around the Korean Peninsula (한반도 주변 해역을 통과한 태풍의 재해특성)

  • Ahn, Suk-Hee;Choi, Ki-Seon;Kim, Baek-Jo;Shin, Seung-Sook
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.109-112
    • /
    • 2008
  • The purpose of this study is to find out the characteristics of disasters caused by typhoons passing through the sea area around the Korean Peninsula. It analyzed two cases, that is, in WEST and EAST cases. These include the typhoons passing through the Yellow Sea, west of the Peninsula and East Sea, east of the Peninsula without landing on the Peninsula. FCM (Fuzzy Clustering Method) analysis was performed on typhoons affecting the Korean Peninsula from 1951 to 2006. The analysis shows that WEST case's cluster has the curved track of NE-S, and EAST case's cluster has the straight track of NE-SW. Typhoons that pass through the Yellow Sea have little change in frequency and the weak intensity. On the other hand, the frequency and the intensity of typhoons passing through the East Sea show the increasing trend. The characteristic of disasters by typhoons affecting the Korean Peninsula from 1973 to 2006 appears differently for each case: EAST cases caused significant damage in flooding, while WEST cases did damage in houses, ships, roads, and bridges. Rainfall amount and maximum wind speed data are analyzed in order to understand the impact of the typhoons, and the result indicates that the WEST cases are influenced by the wind, and East cases by precipitation. The result of this study indicates that the characteristic of disasters is distinctive according to the Typhoon's track. If applied to establish the disaster prevention plan, this result could make a contribution to the damage reduction.

  • PDF

A Study on the Policy Tasks for the Development of National Fire Service - Redesigning Institutional and Organizational Improvement for the Establishment of the National Fire Service Agency - (한국소방발전을 위한 정책과제 연구 - 소방청 신설에 대응하는 제도·조직개선 구상 -)

  • Choi, Byoung-Hahk;Kim, Hak-Soo
    • The Korean Journal of Emergency Medical Services
    • /
    • v.6 no.1
    • /
    • pp.185-197
    • /
    • 2002
  • Today, the basic problem of functional safe management of Korean Disaster Control system was separately administrated 33 acts that are relating to safe management in 13 ministries. Because of the facts that the fire service is not provided practically, the control system and risk management for safe administration are not operated, the information can not be shared with each other, and the various laws have the lacks of linkage, the National Safe System was appeared unsteady. The roles and functions of fire service have started with restriction to operate structurally and institutionally, which operational structure of fire service is becoming weak. As a result, the federal and local fire organizations have not reached yet to the institutionalization and the local fire service agencies have bias with the task regarding the fire service because of the relation between organizational structure and the local fire agency. With the enforcement of the federal and local fire system, professionality and autonomy for making policy, and dealing with changes of fire service positively, the national fire service on the policy performance can be established. Promotion of research and development and education training to strengthen innovation in technology and competition in fire industry will contribute to the firmly establishment of control system to prevent from fire, flood, terror and national disaster. This article proposed that (a) the established law and administration, agency are required efforts to effectively operate fire service system; (b) the national fire service agency, national college of fire, national institute of science fire, and national fire service hospital should be early established to make firmly policy to operate effectively and practically. These kinds of innovational acts are known the best ways of operating solid policy of national fire service system.

  • PDF

Improvement of Domestic Design Criteria of Tunnel Maintenance Monitoring and Latest Technology Trend (터널 유지관리 계측의 국내설계기준 개선 및 최신 기술동향)

  • Baek, Kyung Jong;Kwon, Young Eok
    • Journal of Korean Society of Disaster and Security
    • /
    • v.7 no.2
    • /
    • pp.9-16
    • /
    • 2014
  • Though the maintenance monitoring of structurally weak parts of the tunnel structure in public service must be judged in connection with the monitoring during the construction period for analysis of the behavior of the ground and surrounding structures following the tunnel excavation for the effective management, the monitoring during the construction period and the maintenance monitoring are implemented separately on the basis of the periods of construction and maintenance, so the connectivity and systematic management of the related data are mostly inadequate. The improvement direction is suggested in this thesis, by analyzing the problems of tunnel monitoring in the domestic design criteria. And, it is anticipated that from now on the use of hi-tech sensors and wireless communications technology will proceed vigorously in the maintenance, so considering these situations, the development and application of the maintenance monitoring system and the revision of the domestic design criteria and specification are needed in the future.

Analysis of Wave and Current in Anmok Coastal Waters (안목해안의 파랑과 흐름 분석)

  • Lim, Hak-Soo;Kim, Mujong
    • Journal of Coastal Disaster Prevention
    • /
    • v.4 no.1
    • /
    • pp.7-19
    • /
    • 2017
  • In this study, waves and currents observed by acoustic AWAC, VECTOR and Aquadopp Profiler in Anmok coastal waters were analysed to account for the variability of wave and current and to understand the mechanism of sediment transport generated by wave-induced current in the surf-zone. The monthly variation of wave and residual currents were analysed and processed with long-term observed AWAC data at station W1, located at the water depth of about 18m measured during from February 2015 to September 2016. Wave-induced currents were also analysed with intensive field measurements such as wave, current, suspended sediment, and bathymetry data observed at the surf-zone during in winter and summer. The statistical result of wave data shows that high waves coming from NNE and NE in winter (DEC-FEB) are dominant due to strong winds from NE. But in the other season waves coming from NE and ENE are prevalent due to the seasonal winds from E and SE. The residual currents with southeastern direction parallel to the shoreline are dominant throughout a year except in winter showing in opposite direction. The speed of ebb-dominant southeastern residual currents decreasing from surface to the bottom is strong in summer and fall but weak in winter and spring. By analysing wave-induced current, we found that cross-shore current were generated by swell waves mainly in winter with incoming wave direction about $45^{\circ}$ normal to the shoreline. Depending on the direction of incoming waves, longshore currents in the surf-zone were separated to southeastern and northwestern flows in winter and summer respectively. The variation of observed currents near crescentic bars in the surf-zone shows different direction of longshore and cross-shore currents depending on incoming waves implying to the reason of beach erosion generating the beach cusp and sandbar migration during high waves at Anmok.

An Experimental Study on the Reinforcement of Low-Rise RC Structure for Seismic Performance (저층 RC 건물의 내진성능 보강에 관한 실험적 연구)

  • Kim, Dongbaek;Lee, Byeonghoon;Kwon, Soondong;Lee, Induk
    • Journal of the Society of Disaster Information
    • /
    • v.12 no.2
    • /
    • pp.144-149
    • /
    • 2016
  • Nowaday, most of the low-rise concrete structures which have less than five stories were built before the intensified seismic code was established 2005. According to the fact that our country is not a safety zone ay more, studies are need to reinforce the seismic performance of that structures. The basic frame of low-rise structure are consist of beams and columns with partition walls, therefore that are very weak about secondary wave of earthquake because of the high stiffness. The partition wall are consist of open channel for sunlight or ventilation and intermediate wall. The intermediate walls will enhance the stiffness of columns, but will cause shear failure with short column effects because of the reduced effective depth. But we don't have studies and adequate design code for partition wall effects, therefore some more studies are need for these facts.

Implementation of the Disaster Monitering System with PLC/CDMA Environments (PLC/CDMA 환경에서의 재난 감시 시스템 구현)

  • Park, Sang-Hwan;Kim, In-Min;Yoon, Seon-Tae;Park, Ki-Won;Go, Bong-Jin
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.6
    • /
    • pp.824-830
    • /
    • 2010
  • PLC_Zigbee system, implemented in a previous study, uses ZigBee Node based on PLC (Power Line Communication). The weak point of the system is that the long distance powerline communication and PLC is impossible to use in the areas where the powerline is not installed. In this paper, we added CDMA (Code Division Multiple Access) module using a data transfer method of SMS (Short Message Service) and XBee of WSN (Wireless Sensor Network) module to the previous system, and got around the restriction of place and environment of PLC system through the interfacing of each communication media. We, thus, implemented a wide range of real monitoring system.

Study on Revision of technical Regulation for Location Based Service (위치기반서비스용 무선설비의 기술기준 개선 연구)

  • Lee, Young-Hwan;Jang, Dong-Won;Ha, Deock-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.665-668
    • /
    • 2007
  • The location based service means the service using the location information and the service used based on the location information comes into the spotlight as the critical information of the future mode townsman ubiquitous-City construction. LBS settles down as the core element of ITS or the telematics as the cutting edge technology appearing according to the power generation of the mobile communication technology and recently gradually broadens a range to the public safety service including the distribution management, the asset management, a children and old and the weak protection means, the disaster preparation rescue service like the E-911 of U.S. In the national, the technical regulations about the ground wave LBS was established at November 2005 for the first time in the country. but it actually operated and problems were deduced. Therefore, in this paper, domestic and foreign LBS usage trend and technical standards case try to be analyzed for the revision of the technical regulations of the ground wave LBS serviced in the national and the national technical standards bill for the revision tries to be prepared based on this.

  • PDF

Development of Sensor Monitoring System for Emergency Response of Old School Buildings (노후학교 건축물의 재난대응을 위한 센서 모니터링 시스템 개발)

  • Park, Choon-Wook;Lee, Gyeong-Won;Lee, Ji-Soo
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.27 no.1
    • /
    • pp.3-10
    • /
    • 2020
  • Due to the frequent occurrence of large-scale disasters such as recent earthquakes, the problem of the safety of old school buildings has emerged. The need to secure safety management technology through constant monitoring is increasing in an attempt to supplement old school buildings with weak disaster response capabilities. Traditional research is approaching the development of an existing sensor-based risk precursor information monitoring system. However, unlike this, in this study, we will focus on the development of a data analysis platform as part of the development of a continuous monitoring system that can be prepared for earthquakes, collapses, and fires, based on constantly measured data. For this reason, the development of a safety diagnostic algorithm based on the optimal sensor-attached points and sensor data reflecting the fragile characteristics of old school buildings was derived. Utilizing this, a message and action manual system for each management / use entity of school buildings after retirement was constructed.