• Title/Summary/Keyword: The size of human body

Search Result 489, Processing Time 0.031 seconds

TISSUE REACTION IN RESPONSE TO AUGMENTATION OF SOFT TISSUE DEFECTS ACCORDING TO THE DERMIS GRAFT MATERIALS IN RABBITS (연조직 결손을 일으킨 가토에서 진피 이식재에 따른 조직반응 비교)

  • Ha, Hyun;Kim, Sun-Kook;Ryu, Sun-Youl
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.2
    • /
    • pp.114-120
    • /
    • 2007
  • The augmentation of soft tissue defects is one of the critical problems in the oral and maxillofacial surgery. Various types of graft materials, both autologous and non-autologous, have been used for the augmentation of soft tissue in the facial region. However, it is not easy to choose an ideal material for soft tissue augmentation because each has its advantages and disadvantages. An ideal graft material should meet the following criteria : it should not leave a scar at the area from which it was taken; should have less likelihood of causing infection; should feel natural after implanted; and should be not absorbed. Among the materials meeting these criteria, human dermis and artificial dermis are commonly used for clinical purposes. The present study was aimed to investigate and compare the resorption rate and the histological change following the use of the autologous dermis, the human homogenous dermis $Alloderm^{(R)}$, and the artificial dermis $Terudermis^{(R)}$ to reconstruct the soft tissue defect. Twenty mature rabbits of either sex, weighing about 2 ㎏, were used. Each rabbit was transplanted with the autologous dermis, $Alloderm^{(R)}$, and $Terudermis^{(R)}$ size $1{\times}1-cm$ at the space between the external abdominal oblique muscle and the external abdominal oblique fascia. They were then divided into 4 groups (n=5 each) according to the time elapsed after the surgery: 1, 2, 4, and 8 weeks. The resorption rate was calculated by measuring the volume change before and after the transplantation, and H-E stain was preformed to observe the histological changes. The resorption rate after 8 weeks was 21.5% for the autologous dermis, 16.0% $Alloderm^{(R)}$, and 36.4% $Terudermis^{(R)}$, suggesting that $Alloderm^{(R)}$ is the most stable while $Terudermis^{(R)}$ is the most unstable. In microscopic examinations, the autologous dermis graft was surrounded by inflammatory cells and showed foreign body reactions. The epidermal inclusion cyst was observed in the autologous dermis graft. $Terudermis^{(R)}$ and $Alloderm^{(R)}$ demonstrated neovascularization and the progressive growth of new fibroblast. The results suggest that $Terudermis^{(R)}$ and $Alloderm^{(R)}$ can be availably for substituting the autologous dermis.

Comparison of Temperature Distribution in Agar Phantom and Gel Bolus Phantom by Radiofrequency Hyperthermia

  • Jung, Dong Kyung;Kim, Sung Kyu;Lee, Joon Ha;Youn, Sang Mo;Kim, Hyung Dong;Oh, Se An;Park, Jae Won;Yea, Ji Won
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.224-231
    • /
    • 2016
  • The usefulness of Gel Bolus phantom was investigated by comparing the temperature distribution characteristic of the agar phantom produced to investigate the dose distribution characteristic of radiofrequency hyperthermia device with that of the Gel Bolus phantom under conditions similar to those of an agar phantom that can continuously carry out temperature measurement. The temperatures of the agar phantom and the Gel Bolus phantom were raised to $36.5{\pm}3^{\circ}C$ and a temperature sensing was inserted at depths of 5, 10, and 15 cm from the phantom central axis. The temperature increase rate and the coefficient of determination were analyzed while applying output powers of 100 W and 150 W, respectively, at intervals of 1 min for 60 min under conditions where the indoor temperature was in the range $24.5{\sim}27.5^{\circ}C$, humidity was 35~40%, internal cooling temperature of the electrode was $20^{\circ}C$, size of the upper electrode was 250 mm, and the size of the lower electrode was 250 mm. The coefficients of determination of 150 W output power at the depth point of 5 cm from the central axis of the phantom were analyzed to be 0.9946 and 0.9926 in the agar and Gel Bolus phantoms, respectively; moreover, the temperature change equation of the agar and Gel Bolus phantoms with time can be expressed as follows in the state the phantom temperature is raised to $36^{\circ}C:Y(G)$ is equation of Gel Bolus phantoms (in 5 cm depth) applying output power of 150 W. Y(G)=0.157X+36. It can be seen that if the temperature is measured in this case, the Gel Bolus phantom value can be converted to the measured value of the agar phantom. As a result of comparing the temperature distribution characteristics of the agar phantom of a human-body-equivalent material with those of the Gel Bolus phantom that can be continuously used, the usefulness of Gel Bolus phantom was exhibited.

Development and Evaluation of Natural Hydroxyapatite Ceramics Produced by the Heat Treatment of Pig Bones

  • Lim, Ki-Taek;Kim, Jin-Woo;Kim, Jangho;Chung, Jong Hoon
    • Journal of Biosystems Engineering
    • /
    • v.39 no.3
    • /
    • pp.227-234
    • /
    • 2014
  • Purpose: The aim of this research was to develop and evaluate natural hydroxyapatite (HA) ceramics produced from the heat treatment of pig bones. Methods: The properties of natural HA ceramics produced from pig bones were assessed in two parts. Firstly, the raw materials were characterized. A temperature of $1,200^{\circ}C$ was chosen as the calcination temperature. Fine bone powders (BPs) were produced via calcinations and a milling process. Sintered BPs were then characterized using field emission scanning electron microscopy (FE-SEM), X-ray diffraction (XRD), X-ray fluorescence spectroscopy (XRF), energy dispersive X-ray spectroscopy (EDX), Fourier transform infrared (FTIR) spectroscopy, and a 2-year in vitro degradability test. Secondly, an indirect cytotoxicity test was conducted on human osteoblast-like cells, MG63, treated with the BPs. Results: The average particle size of the BPs was $20{\pm}5{\mu}m$. FE-SEM showed a non-uniform distribution of the particle size. The phase obtained from XRD analysis confirmed the structure of HA. Elemental analysis using XRF detected phosphorus (P) and calcium (Ca) with the Ca/P ratio of 1.6. Functional groups examined by FTIR detected phosphate ($PO{_4}^{3-}$), hydroxyl ($OH^-$), and carbonate ($CO{_3}^{2-}$). The EDX, XRF, and FTIR analysis of BPs indicated the absence of organic compounds, which were completely removed after annealing at $1,200^{\circ}C$. The BPs were mostly stable in a simulated body fluid (SBF) solution for 2 years. An indirect cytotoxicity test on natural HA ceramics showed no threat to the cells. Conclusions: In conclusion, the sintering temperature of $1,200^{\circ}C$ affected the microstructure, phase, and biological characteristics of natural HA ceramics consisting of calcium phosphate. The Ca-P-based natural ceramics are bioactive materials with good biocompatibility; our results indicate that the prepared HA ceramics have great potential for agricultural and biological applications.

Pre-service Elementary Teachers' Conceptions on the Relative Sizes of Celestial Bodies (천체의 상대적 크기에 대한 초등 예비교사들의 인식)

  • Jang, Myoung-Duk;Nam, Younkyeong
    • Journal of the Korean earth science society
    • /
    • v.33 no.7
    • /
    • pp.645-657
    • /
    • 2012
  • The purpose of this study was to investigate pre-service elementary teachers' conceptions about the relative sizes of celestial bodies including the universe, galaxy, star, planet, satellite, asteroid, and comet, which were presented in elementary school science textbook. This study also examined the causes of their misconceptions as shown in the study. Sixty three pre-service elementary teachers participated in this study. The survey was developed for this study that asked to make an order of relative sizes of the given celestial bodies and to write scientific facts about each of the celestial bodies. The survey items were analyzed by simple descriptive statistics, and the written responses were analyzed using qualitative and inductive methods. The results showed that only five (7.9%) of the participants correctly answered about the relative size of the given celestial bodies. There were three common misconceptions identified in relation to the relative sizes of the celestial bodies; more than 20% of the participants had: (1) a planet is bigger than a star (46.0% of the participants), (2) an asteroid is bigger than satellite (58.7%), 3) a comet is bigger than a star (22.2%).

Auto-Segmentation Algorithm For Liver-Vessel From Abdominal MDCT Image (복부 MDCT 영상으로부터 간혈관 자동 추출 알고리즘)

  • Park, Seong-Me;Lee, You-Jin;Park, Jong-Won
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.3
    • /
    • pp.430-437
    • /
    • 2010
  • It is essential for living donor liver transplantation that surgeon must understand the hepatic vessel structure to improve the success rate of operation. In this paper, we extract the liver boundary without other surrounding structures such as heart, stomach, and spleen using the contrast enhanced MDCT liver image sequence. After that, we extract the major hepatic veins (left, middle, right hepatic vein) with morphological filter after review the basic structure of hepatic vessel which reside in segmented liver image region. The purpose of this study is provide the overall status of transplantation operation with size estimation of resection part which is dissected along with the middle hepatic vein. The method of liver extraction is as follows: firstly, we get rid of background and muscle layer with gray level distribution ratio from sampling process. secondly, the coincident images match with unit mesh image are unified with resulted image using the corse coordinate of liver and body. thirdly, we extract the final liver image after expanding and region filling. Using the segmented liver images, we extract the hepatic vessels with morphological filter and reversed the major hepatic vessels only with a results of ascending order of vessel size. The 3D reconstructed views of hepatic vessel are generated after applying the interpolation to provide the smooth view. These 3D view are used to estimate the dissection line after identify the middle hepatic vein. Finally, the volume of resection region is calculated and we can identify the possibility of successful transplantation operation.

Lifetime test of batteries for BLE modules for site identification of vessel's crews and passengers (SIVCP) (SIVCP용 BLE 모듈의 배터리 수명시험)

  • Kwon, Hyuk-joo;Kim, Min-Gwon;Kim, Yoon-Sik;Lee, Sung-Geun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.7
    • /
    • pp.754-759
    • /
    • 2015
  • Nowadays, short distance communication systems with low power energy (LPE) are developed for identification and monitoring of site identification of vessel crews and passengers (SIVCP). LPE communication modules, such as Bluetooth low energy (BLE) and Zigbee, are used for short distance communications with LPE. These modules enable 1:N communications and their popularity is growing since the modules can be mounted on movable objects, such as mobile devices and human body. When these modules are used, the important factor that affects their operation time and design are the capacity and size of battery. Therefore, they must be made as small as possible, and the battery should be selected to be slightly smaller than the module. In this study, we calculate the theoretical life of batteries used in SIVCP BLE modules using data sheet and discharge characteristic graph under the condition of a 1/250 transmission-ratio (TR). We thus calculate experimental life by measuring transmission current for the same TR, and low speed mode current for a 1/5000 TR and measure long-term experimental life using 1/25 TR for days. Through these experiments, we verify experimental methods for the prediction and extension of battery life that would enable us to select appropriate sizes of batteries based on vessel usage and passenger types. The selections of the module TR and battery size are important factors affecting the cost reduction of module design, the battery maintenance, and passenger convenience.

Harmfulness of Particulate Matter in Disease Progression (미세먼지의 질병에 미치는 유해성)

  • Choi, Jong Kyu;Choi, In Soon;Cho, Kwang Keun;Lee, Seung Ho
    • Journal of Life Science
    • /
    • v.30 no.2
    • /
    • pp.191-201
    • /
    • 2020
  • As society develops rapidly, environmental pollution is becoming a greater risk factor threatening human health. One of the major causes of air pollution that affects human health is particulate matter (PM), which contains a heterogeneous mixture of different particle sizes and chemical compositions. PM is classified by size into general PM (PM10; diameter below 10 ㎛) and fine PM (PM2.5; diameter below 2.5 ㎛). PM2.5 can pass through the respiratory tract into the circulatory system and thence throughout the body. PM2.5 is known to stimulate oxidative stress and inflammatory responses to cells, promoting diseases such as asthma, chronic respiratory disease, cardiovascular disease, diabetes mellitus, and immunological disorders. Although detailed molecular mechanisms for how PM stimulates disease progression still need to be elucidated, together with national efforts to reduce PM production, significant research has been conducted that demonstrates the harmfulness of PM in disease progression through in vitro and in vivo experiments. This review focuses on the harmfulness of PM in disease progression; we also introduce a biological verification method for determining the hazards of PM.

Anti-cancer effect of Sarijang on colorectal cancer cells in a xenograft nude mouse model (대장암 세포가 이식된 동물모델에서 사리장의 항암효과에 대한 연구)

  • Lee, Tae-Hee;Song, Hyun-Kyung;Kim, Dong-Yoon;Lee, Isaac;Seo, Hyeong-Ho;Choi, Ji-Young;Kim, Hong-Geun;Choi, Eun-A;Han, Beom-Seok
    • Korean Journal of Food Science and Technology
    • /
    • v.50 no.4
    • /
    • pp.451-456
    • /
    • 2018
  • The current study was conducted to confirm the anti-cancer effect of Sarijang, which is a mixture of extracts from purple bamboo salt, Rhynchosia nulubilis, garlic, and Ulmi cortex. Nude mice were injected with a human-derived colorectal cancer cell (HCT116 cell line) and subsequently administered Sarijang for 4 weeks, following which the body weight, organ weight, and tumor size were measured. To evaluate the anti-cancer mechanism of Sarijang, the levels of p16 and extracellular signal-regulated kinase (ERK), cell cycle regulators in colorectal cancer, were measured. To evaluate the toxicity of Sarijang on liver and kidney, aspartate transaminase, alanine transaminase, blood urea nitrogen, and creatinine were analyzed. Sarijang not only reduced the tumor size by enhancing p16 and suppressing ERK, but also showed no side-effect in the liver and kidneys. Taken together, Sarijang has the potential to inhibit tumor growth without side effects, and may be used as a useful functional food.

A Study on a Quantified Structure Simulation Technique for Product Design Based on Augmented Reality (제품 디자인을 위한 증강현실 기반 정량구조 시뮬레이션 기법에 대한 연구)

  • Lee, Woo-Hun
    • Archives of design research
    • /
    • v.18 no.3 s.61
    • /
    • pp.85-94
    • /
    • 2005
  • Most of product designers use 3D CAD system as a inevitable design tool nowadays and many new products are developed through a concurrent engineering process. However, it is very difficult for novice designers to get the sense of reality from modeling objects shown in the computer screens. Such a intangibility problem comes from the lack of haptic interactions and contextual information about the real space because designers tend to do 3D modeling works only in a virtual space of 3D CAD system. To address this problem, this research investigate the possibility of a interactive quantified structure simulation for product design using AR(augmented reality) which can register a 3D CAD modeling object on the real space. We built a quantified structure simulation system based on AR and conducted a series of experiments to measure how accurately human perceive and adjust the size of virtual objects under varied experimental conditions in the AR environment. The experiment participants adjusted a virtual cube to a reference real cube within 1.3% relative error(5.3% relative StDev). The results gave the strong evidence that the participants can perceive the size of a virtual object very accurately. Furthermore, we found that it is easier to perceive the size of a virtual object in the condition of presenting plenty of real reference objects than few reference objects, and using LCD panel than HMD. We tried to apply the simulation system to identify preference characteristics for the appearance design of a home-service robot as a case study which explores the potential application of the system. There were significant variances in participants' preferred characteristics about robot appearance and that was supposed to come from the lack of typicality of robot image. Then, several characteristic groups were segmented by duster analysis. On the other hand, it was interesting finding that participants have significantly different preference characteristics between robot with arm and armless robot and there was a very strong correlation between the height of robot and arm length as a human body.

  • PDF

Embryonic and Larval Development of Slender Catfish, Silurus microdorsalis Mori, 1936, Endemic to Korea (한국 고유종 미유기(Silurus microdorsalis Mori, 1936)의 난 발생 및 자치어 형태발달)

  • Kang-Rae Kim;Yeong-Ho Kwak;Mu-Sung Sung;Heon Yang;Seong-Jang Cho;Bong Han Yun;In-Chul Bang
    • Korean Journal of Ichthyology
    • /
    • v.35 no.2
    • /
    • pp.91-100
    • /
    • 2023
  • The early life history of Silurus microdorsalis living in Jahocheon Stream was studied by observing egg and morphological development. Live fish were captured in June 2018, then reared in a circulating filtration system under a 14L : 10D photoperiod with a water temperature of 18℃. To artificially induce spawning, females were injected with 0.5 mL of Ovaprim (Syndel, Nanaimo, BC, Canada) per kg of body weight, and males were injected with 10,000 IU/kg body weight of human chorionic gonadotropin. Approximately 15 h later, eggs were artificially inseminated by the dry method. Mature eggs were light pale yellow, which separated them from immature eggs. Fertilized eggs were 2.16±0.06 mm (n=8) in diameter and fully hatched at 181 h after fertilization. The fertilization rate was 63.1±2.2%, and 10.0±3.7% of the embryos were malformed at 18℃. The rates of development were 181 h at 18℃, 109 h at 21℃, and 76 h at 24℃. The larval size immediately after hatching was 4.64±0.22 mm (n=8), and the larvae displayed negative phototaxis at 1 day after hatching. The total larval length on 7 days after hatching was 12.47±0.53 mm, with 25~30 basal anal fin rays and 14~16 basal caudal fin rays observed. The total larval length was 14.13±0.51 mm on 9 days after hatching, and approximately 90% of the black endoplasmic reticulum was deposited on the head and body. The dorsal fin had formed, and a single basal body was observed. On 15 days after hatching, the total larval length was 16.69±0.31 mm; the number of basal caudal fin rays (18 poles) was an integer because 2 dorsal fin basal rays and 60~63 anal fin basal rays were observed. The total larval length was 28.96±1.10 mm on 50 days after hatching; the numbers of caudal fins (n=18), dorsal fins (n=3), pectoral fins (n=11), and anal fin basal rays (n=67~73) were integers.