• Title/Summary/Keyword: The single transformer

검색결과 380건 처리시간 0.028초

Magnetic Field Analysis of 1 MVA HTS Transformer Windings

  • Park, Chan-Bae;Kim, Woo-Seok;Lee, Sang-Jin;Han, Jin-Ho;Park, Kyeong-Dal;Joo, Hyeong-Gil;Hong, Gye-Won;Hahn, Song-Yop
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권1호
    • /
    • pp.66-70
    • /
    • 2003
  • In a HTS transformer, the perpendicular component of magnetic flux density ($B_r$) applied to HTS tapes of pancake windings becomes larger than that of solenoid winding, thereby decreasing the critical current in the HTS tapes. This paper introduces several methods to reduce $B_r$ applied to the HTS tapes in the transformer with double pancake windings by changing winding arrangements and the relative permeability of flux diverters. We have conducted a winding design for a single-phase 1MVA 22.9kV/6.6kV HTS transformer. We observed a change of $B_r$ due to a variation of gap-length between the high voltage windings and the low voltage windings, reciprocal arrangement and an increase of the number of the high voltage pancake. We also observed a change of Br on the HTS tapes due to variation of the relative permeability of flux diverters placed between the high voltage winding and the low voltage winding. Finally, we have designed a 1MVA 22.9kV/6.6kV HTS transformer winding using suggested methods and calculated transformer parameters by the 3D finite element method.

식물성 절연유 변압기의 냉각특성 변화에 따른 최고점온도 특성 해석 (Characteristic Analysis of Hot Spot Temperature according to Cooling Performance Variation of Natural Ester Transformer)

  • 김지호;이향범
    • 전기학회논문지P
    • /
    • 제64권4호
    • /
    • pp.236-240
    • /
    • 2015
  • Natural ester has a higher biodegradability, flash and fire points, and a greater permittivity compared to conventional mineral oils. However, natural ester also has a higher pour point, viscosity, and water content. These characteristics hamper circulation and the electrical properties of oil-filled transformer. Thus, this paper applied electromagnetic-thermal-flow coupled analysis method to predict temperature distribution inside 154kV single phase power transformer using natural ester. It modeled in the actual appearance for the tank and winding of the power transformer to improve the accuracy of analysis and applied heat flow analysis that considered hydromechanics and heat transfer at the same time. It calculated the power loss, the main cause of temperature rise, from winding and core with electromagnetic analysis then used for the heat source for the heat flow analysis. It then compared the reasonability of result of measurement analysis based on the result acquired from temperature rise test using FBG sensor on the power transformer.

1MVA 고온초전도 변압기용 더블 팬케이크 권선의 절연시험 (Test of Insulation of Double Pancake Windings for a 1MVA HTS Transformer)

  • 김성훈;김우석;최경달;주형길;홍계원;한진호;한송엽;송희석;박정호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1015-1017
    • /
    • 2003
  • In a research and development team of high temperature superconducting (HTS) transformer for power distribution, prior to manufacture a single phase 1MVA 22.9 kV/6.6 kV HTS transformer, a 1MVA transformer for insulation test with windings made of copper tapes with the same size as BSCCO-2223 HTS tape was manufactured. The test transformer was composed of both the copper windings of double pancake type and the shell type core of laminated silicon steel plates. The characteristics tests of the test transformer were performed, such as no load test, load test and short test at 77k using liquid nitrogen. Insulation tests, lightning impulse test, power-frequency voltage test and external insulation test, were accomplished also.

  • PDF

쇄교자속비를 이용한 3권선 변압기 보호 (Three-Winning Transformer Protection Based on Flux Linkage Ratio)

  • 강용철;이병은;김은숙;원성호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권7호
    • /
    • pp.375-381
    • /
    • 2004
  • This paper describes a three-winding transformer protective relaying algorithm based on the ratio of increments of flux linkages (RIFL). To minimize the approximation errors, the algorithm uses integration approximation. The RIFL of the two windings is equal to the turns ratio for all operating conditions except for an internal fault. For a single-phase and three-phase transformer containing the wye-connected windings, the increments of flux linkages (IFL) are calculated. For a three-phase transformer containing the delta-connected windings, the difference of IFL between the two phases are calculated to use the line currents, because the winding currents are practically unavailable. Their ratios are compared with the turns ratio. The comparative study between the proposed and differential approximation methods was conducted. The test results show that the algorithm can reduce the errors resulting from the conventional methods.

유기 전압비를 이용한 3권선 변압기 보호계전 알고리즘 (A Three-Winding Transformer Protective Relaying Algorithm Based on the Induced Voltages)

  • 강용철;이병은
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권3호
    • /
    • pp.173-178
    • /
    • 2003
  • This paper proposes a three-winding transformer protective relaying algorithm based on the ratio of the induced voltages (RIV). The RIV of the two windings is the same as the turn ratio for all operating conditions except an internal fault. For a single phase and a three-phase transformer containing the wye-connected windings, the induced voltages of the windings are estimated. For a three-phase transformer containing the delta-connected windings, the induced voltage differences are estimated using the line currents, because the winding currents are practically unavailable. The algorithm can identify the faulted phase and winding if a fault occurs on one phase of a winding. The test results clearly show that the algorithm successfully discriminates internal winding faults from magnetic inrush. The algorithm not only does not require hysteresis data but also can reduce the operating time of a relay.

주상변압기 고압권선의 서지응답 특성 (Electrical Characteristics of Insulation Paper for Distribution Transformers)

  • 송일근;정종욱;이병성;이재봉;김상준;오재형
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.156-159
    • /
    • 2002
  • This paper presents an experimental study of the surge response characteristics for the primary winding of a pole transformer and ultimately aims at devising countermeasures against the surge in operating transformer. After applying the impulse voltage to the primary of the 30 kVA pole transformer with single bushing, the voltage waveforms were measured at each tap lead and compared with one another. As a result, the voltage peak of the surge propagating in the primary was decreased in magnitude at a constant rate and somewhat delayed compared to the peak of the applied surge as the tap leads were getting closer to the grounding terminal. The voltage measured at the secondary was not delayed in time, different from that at the primary, and it was about 1/6 according to the turn ratio.

  • PDF

Winding Temperature Measurement in a 154 kV Transformer Filled with Natural Ester Fluid

  • Kweon, Dongjin;Koo, Kyosun
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권1호
    • /
    • pp.156-162
    • /
    • 2013
  • This paper measures the hot spot temperatures in a single-phase, 154 kV, 15/20 MVA power transformer filled with natural ester fluid using optical fiber sensors and compares them with those calculated by conventional heat run tests. A total of 14 optical fiber sensors were installed on the high-voltage and low-voltage windings to measure the hot spot temperatures. In addition, three thermocouples were installed in the transformer to measure the temperature distribution during the heat run tests. In the low-voltage winding, the hot spot temperature was $108.4^{\circ}C$, calculated by the conventional heat run test. However, the hot spot temperature measured using the optical fiber sensor was $129.4^{\circ}C$ between turns 2 and 3 on the upper side of the low-voltage winding. Therefore, the hot spot temperature of the low-voltage winding measured using the optical fiber sensor was $21.0^{\circ}C$ higher than that calculated by the conventional heat run test.

Characteristics of Non-Isolated OSAKA Converter -Characteristics of Three-Phase Soft-Switching Power Factor Corrected Converter for Large Scale Power Without Three-Phase Transformer-

  • Taniguchi, Katsunori;Shimomori, Wataru;Lee, Hyun-Woo
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1383-1386
    • /
    • 2005
  • Non-isolated OSAKA Converter, which removes a three-phase transformer, is described in this paper. The converter switches once in every half cycle of an AC commercial power source. Therefore, it can solve many problems caused by the high frequency operation. The proposed converter achieves the soft-switching operation and the EMI noise can be reduced. In this circuit, the resonant capacitor, which is used for the soft-switching operation, is utilized for the improvement of an input current waveform. To achieve low cost and compact structure, non-isolated OSAKA converter removes a three-phase transformer of the OSAKA converter. By removing the three-phase transformer, three phase currents occur the interferences each other. To avoid the interference, a new switching method for non-isolated OSAKA converter is preposed. The converter can be constructed by the low-speed large power devices. The converter generates the low distorted input current waveforms with high power factor.

  • PDF

An Ensemble Model for Credit Default Discrimination: Incorporating BERT-based NLP and Transformer

  • Sophot Ky;Ju-Hong Lee
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2023년도 춘계학술발표대회
    • /
    • pp.624-626
    • /
    • 2023
  • Credit scoring is a technique used by financial institutions to assess the creditworthiness of potential borrowers. This involves evaluating a borrower's credit history to predict the likelihood of defaulting on a loan. This paper presents an ensemble of two Transformer based models within a framework for discriminating the default risk of loan applications in the field of credit scoring. The first model is FinBERT, a pretrained NLP model to analyze sentiment of financial text. The second model is FT-Transformer, a simple adaptation of the Transformer architecture for the tabular domain. Both models are trained on the same underlying data set, with the only difference being the representation of the data. This multi-modal approach allows us to leverage the unique capabilities of each model and potentially uncover insights that may not be apparent when using a single model alone. We compare our model with two famous ensemble-based models, Random Forest and Extreme Gradient Boosting.

The study of Method for the Diagnosis of Transformers Trouble

  • Song, Jae-Tae;Jeong, Seung-Cheol;Choi, Hyun-Seob;Park, Poo-Gyeon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.118.1-118
    • /
    • 2001
  • In this paper, we suggest a new distribution model for a single phase transformer which is different from the existing model which was modeled for only primary parts, but new distribution model is modeled for primary and secondary parts. Using this model, we simulate various faults of the transformer to know how the transfer function vary from the normal one, i.e., the trend of the variation of transfer function. As an another approach, we measure the voltage and current of a three phase transformer while various faults are made at the transformer. From the simulation of the model and experiment, we fine some trends of the variation of transfer function.

  • PDF