• 제목/요약/키워드: The period of Vibration

검색결과 450건 처리시간 0.026초

공간평가를 위한 피스톨음원의 적정성에 관한 연구 (A Study of Enemy Aptitude of Pistol Sound Source for Space Estimation)

  • 송장렬;김정중
    • 한국소음진동공학회논문집
    • /
    • 제15권3호
    • /
    • pp.320-328
    • /
    • 2005
  • Last target of architectural acoustics is that people wish to convey voice effectively from the space adaptively in use purpose in building. But, how exactly through space sound (sound source) that wish to deliver from indoor can be passed method to do quantification and evaluate quantity of sound by method to serve indoor architectural acoustics estimation summer period and methods to estimate definition propose. This Study searches special quality of sound source about MLS signal that is occurred short-answer sound source (pistol sound source) and nondirectional speaker among indoor sound estimation method, and measure and analyzed reverberation time (RT60), definition (C80, D50) by regulation of each ISO 3382 in age place (classroom, hall, gymnasium). Analysis result and sound factor among could know that d of two sound sources converges in measurement error extent about reverberation time (RT60) of analysis incidental and sound factors and value shows change irregularly about sound factor of D50, C80, pistol sound source judged there is problem. Also, could know that problem is happened in deflection except reverberation time is in deflection analysis with wave that measure each in fixed distance in branch. Finally, when differ size of sound source and measure about change of sound pressure level in case measure sound pressure level giving difference about 10 dB, sound factor could know that there is no different effect.

Experimental Study on the Unsteady Flow Characteristics for the Counter-Rotating Axial Flow Fan

  • Cho, L.S.;Lee, S.W.;Cho, J.S.;Kang, J.S.
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.790-798
    • /
    • 2008
  • Counter-rotating axial flow fan(CRF) consists of two counter-rotating rotors without stator blades. CRF shows the complex flow characteristics of the three-dimensional, viscous, and unsteady flow fields. For the understanding of the entire core flow in CRF, it is necessary to investigate the three-dimensional unsteady flow field between the rotors. This information is also essential to improve the aerodynamic characteristics and to reduce the aerodynamic noise level and vibration characteristics of the CRF. In this paper, experimental study on the three-dimensional unsteady flow of the CRF is performed at the design point(operating point). Flow fields in the CRF are measured at the cross-sectional planes of the upstream and downstream of each rotor using the $45^{\circ}$ inclined hot-wire. The phase-locked averaged hot-wire technique utilizes the inclined hot-wire, which rotates successively with 120 degree increments about its own axis. Three-dimensional unsteady flow characteristics such as tip vortex, secondary flow and tip leakage flow in the CRF are shown in the form of the axial, radial and tangential velocity vector plot and velocity contour. The phase-locked averaged velocity profiles of the CRF are analyzed by means of the stationary unsteady measurement technique. At the mean radius of the front rotor inlet and the outlet, the phase-locked averaged velocity profiles show more the periodical flow characteristics than those of the hub region. At the tip region of the CRF, the axial velocity is decreased due to the boundary layer effect of the fan casing and the tip vortex flow. The radial and the tangential velocity profiles show the most unstable and unsteady flow characteristics compared with other position of rotors. But, the phase-locked averaged velocity profiles of the downstream of the rear rotor show the aperiodic flow pattern due to the mixture of the front rotor wake period and the rear rotor rotational period.

  • PDF

전기집진장치의 코로나 전류 발생 전극 제작에 따른 추타력 비교에 관한 연구 (The Study of Comparison on Rapping Force on Generation of Corona Discharge Electrode of Electrostatic Precipitator)

  • 이강욱;박정호;장성호;임우택;서정민
    • 한국환경과학회지
    • /
    • 제26권2호
    • /
    • pp.231-238
    • /
    • 2017
  • Rapid industrial development has led to a serious problem of pollution in the industrial sector. With the increasing social need for environmental protection, research on air pollution prevention equipment for reducing pollutants in industrial processes is actively being undertaken. The deterioration of existent, installed facilities, their increased emission rates, and the strengthening of the effluent quality standards make complying with permissible emission standards difficult. In fact, installing new electric precipitators or complementing existent facilities is inevitable. The expansion and complementation of the installed electrical precipitators have led to improvements in dust collection efficiency, shorter working times, and lower costs. Because of its easy installation and simple manufacturing process, the production method with the discharge electrode of an electric precipitator is widely used. The following conclusions were reached by classifying discharge electrodes into four types based on the production method and mutually comparing them by their dust collection efficiency. None of the four types used in this study were damaged by impact. However, we were able to confirm some strain from the compression sites of both type A and type B. Both type B and type C are expected to have greater dust collection efficiencies than the other models due to their large vibration transmissibility. Moreover, the high vibrational energy is expected to cause rapping damage during its operation. Particularly, in the case of type B, some of the strain was found at the end of the compression site. The coupling schemes of both type C and type D are out of vibration transmissibility. On the other hand, the ability to maintain straightness and solidity of the side is regarded as outstanding and stable. Type D has outstanding on-site workability, considering the presence of locking, structural stability, and work conditions. From these experiments, we determined that type C is the most ideal connection method of discharge electrode, considering its construction period of renovation. Type C is inferior to type D with regard to on-site workability. However, type C has outstanding dedusting transmission with regard to the straightness, solidity maintenance, and vibration of shearing stress.

Conditional mean spectrum for Bucharest

  • Vacareanu, Radu;Iancovici, Mihail;Pavel, Florin
    • Earthquakes and Structures
    • /
    • 제7권2호
    • /
    • pp.141-157
    • /
    • 2014
  • The Conditional Mean Spectrum represents a powerful link between the seismic hazard information and the selection of strong ground motion records at a particular site. The scope of the paper is to apply for the city of Bucharest for the first time the method to obtain the Conditional Mean Spectrum (CMS) presented by Baker (2011) and to select, on the basis of the CMS, a suite of strong ground motions for performing elastic and inelastic dynamic analyses of buildings and structures with fundamental periods of vibration in the vicinity of 1.0 s. The major seismic hazard for Bucharest and for most of Southern and Eastern Romania is dominated by the Vrancea subcrustal seismic source. The ground motion prediction equation developed for subduction-type earthquakes and soil conditions by Youngs et al. (1997) is used for the computation of the Uniform Hazard Spectrum (UHS) and the CMS. The disaggregation of seismic hazard is then performed in order to determine the mean causal values of magnitude and source-to-site distance for a particular spectral ordinate (for a spectral period T = 1.0 s in this study). The spectral period of 1.0 s is considered to be representative for the new stock of residential and office reinforced concrete (RC) buildings in Bucharest. The differences between the Uniform Hazard Spectrum (UHS) and the Conditional Mean Spectrum (CMS) are discussed taking into account the scarcity of ground motions recorded in the region of Bucharest and the frequency content characteristics of the recorded data. Moreover, a record selection based on the criteria proposed by Baker and Cornell (2006) and Baker (2011) is performed using a dataset consisting of strong ground motions recorded during seven Vrancea seismic events.

Service Life Prediction of Rubber Bushing for Tracked Vehicles

  • Woo, Chang-Su;Kang, In-Sug;Lee, Kang-Suk
    • Elastomers and Composites
    • /
    • 제55권2호
    • /
    • pp.81-87
    • /
    • 2020
  • Service life prediction and evaluation of rubber components is the foundational technology necessary for securing the safety and reliability of the product and to ensure an optimum design. Even though the domestic industry has recognized the importance thereof, technology for a systematic design and analysis of the same has not yet been established. In order to develop this technology, identifying the fatigue damage parameters that affect service life is imperative. Most anti-vibration rubber components had been damaged by repeated load and aging. Hence, the evaluation of the fatigue characteristics is indispensable. Therefore, in this paper, we propose a method that can predict the service life of rubber components relatively accurately in a short period of time. This method works even in the initial designing stage. We followed the service life prediction procedure of the proposed rubber components. The weak part of the rubber and the maximum strain were analyzed using finite element analysis of the rubber bushing for the tracked vehicles. In order to predict the service life of the rubber components that were in storage for a certain period of time, the fatigue test was performed on the three-dimensional dumbbell specimen, based on the results obtained by the rubber material acceleration test. The service life formula of the rubber bushing for tracked vehicles was derived using both finite element analysis and the fatigue test. The service life of the rubber bushing for tracked vehicles was estimated to be about 1.7 million cycles at room temperature (initial stage) and about 400,000 cycles when kept in storage for 3 years. Through this paper, the service life for various rubber parts is expected be predicted and evaluated. This will contribute to improving the durability and reliability of rubber components.

Combining GPS and accelerometers' records to capture torsional response of cylindrical tower

  • AlSaleh, Raed J.;Fuggini, Clemente
    • Smart Structures and Systems
    • /
    • 제25권1호
    • /
    • pp.111-122
    • /
    • 2020
  • Researchers up to date have introduced several Structural Health Monitoring (SHM) techniques with varying advantages and drawbacks for each. Satellite positioning systems (GPS, GLONASS and GALILEO) based techniques proved to be promising, especially for high natural period structures. Particularly, the GPS has proved sufficient performance and reasonable accuracy in tracking real time dynamic displacements of flexible structures independent of atmospheric conditions, temperature variations and visibility of the monitored object. Tall structures are particularly sensitive to oscillations produced by different sources of dynamic actions; such as typhoons. Wind forces induce in the structure both longitudinal and perpendicular displacements with respect to the wind direction, resulting in torsional effects, which are usually more complex to be detected. To efficiently track the horizontal rotations of the in-plane sections of such flexible structures, two main issues have to be considered: a suitable sensor topology (i.e., location, installation, and combination of sensors), and the methodology used to process the data recorded by sensors. This paper reports the contributions of the measurements recorded from dual frequency GPS receivers and uni-axial accelerometers in a full-scale experimental campaign. The Canton tower in Guangzhou-China is the case study of this research, which is instrumented with a long-term structural health monitoring system deploying both accelerometers and GPS receivers. The elaboration of combining the obtained rather long records provided by these two types of sensors in detecting the torsional behavior of the tower under ambient vibration condition and during strong wind events is discussed in this paper. Results confirmed the reliability of GPS receivers in obtaining the dynamic characteristics of the system, and its ability to capture the torsional response of the tower when used alone or when they are combined with accelerometers integrated data.

The effect of composite-elastomer isolation system on the seismic response of liquid-storage tanks: Part I

  • Shahrjerdi, A.;Bayat, M.
    • Earthquakes and Structures
    • /
    • 제15권5호
    • /
    • pp.513-528
    • /
    • 2018
  • A typical viable technique to decrease the seismic response of liquid storage tanks is to isolate them at the base. Base-isolation systems are an efficient and feasible solution to reduce the vulnerability of structures in high seismic risk zones. Nevertheless, when liquid storage tanks are under long-period shaking, the base-isolation systems could have different impacts. These kinds of earthquakes can damage the tanks readily. Hence, the seismic behaviour and vibration of cylindrical liquid storage tanks, subjected to earthquakes, is of paramount importance, and it is investigated in this paper. The Finite Element Method is used to evaluate seismic response in addition to the reduction of excessive liquid sloshing in the tank when subjected to the long-period ground motion. The non-linear stress-strain behaviour pertaining to polymers and rubbers is implemented while non-linear contact elements are employed to describe the 3-D surface-to-surface contact. Therefore, Nonlinear Procedures are used to investigate the fluid-structure interactions (FSI) between liquid and the tank wall while there is incompressible liquid. Part I, examines the effect of the flexibility of the isolation system and the tank aspect ratio (height to radius) on the tank wall radial displacements of the tank wall and the liquid sloshing heights. Maximum stress and base shear force for various aspect ratios and different base-isolators, which are subjected to three seismic conditions, will be discussed in Part II. It is shown that the composite-base isolator is much more effective than other isolators due to its high flexibility and strength combined. Moreover, the base isolators may decrease the maximum level pertaining to radial displacement.

Failure prediction of a motor-driven gearbox in a pulverizer under external noise and disturbance

  • Park, Jungho;Jeon, Byungjoo;Park, Jongmin;Cui, Jinshi;Kim, Myungyon;Youn, Byeng D.
    • Smart Structures and Systems
    • /
    • 제22권2호
    • /
    • pp.185-192
    • /
    • 2018
  • Participants in the Asia Pacific Conference of the Prognostics and Health Management Society 2017 (PHMAP 2017) Data Challenge were given measured vibration signals from motor-driven gearboxes used in pulverizers. Using this information, participants were requested to predict failure dates and the faulty components. The measured signals were affected by significant noise and disturbance, as the pulverizers in the provided data worked under actual operating conditions. This paper thus presents a fault prediction method for a motor-driven gearbox in a pulverizer system that can perform under external noise and disturbance conditions. First, two fault features, an RMS value in the higher frequency zones (HRMS) and an amplitude of a period for high-speed shaft in the quefrency domain ($QA_{HSS}$), were extracted based on frequency analysis using the higher and lower sampling rate data. The two features were then applied to each pulverizer based on results of frequency responses to impact loadings. Then, a regression analysis was used to predict the failure date using the two extracted features. A weighted regression analysis was used to compensate for the imbalance of the features in the given period. In addition, the faulty components in the motor-driven gearboxes were predicted based on the modulated frequency components. The score predicted by the proposed approach was ranked first in the PHMAP 2017 Data Challenge.

A study on the relationship between exposure to hazardous and risk factors and absenteeism according to the period of the Korean Working Conditions Survey

  • Jin-Yeub Jung;Seo-Yeon Choi
    • 한국컴퓨터정보학회논문지
    • /
    • 제28권8호
    • /
    • pp.165-174
    • /
    • 2023
  • 본 연구는 국내 근로환경조사 자료를 이용하여 조사 시기에 따른 제조업 종사자의 유해·위험요인 노출과 결근과의 관련성을 확인하였다. 이에 2011년도(3차), 2017년도(5차), 2020년도(6차)의 유해·위험요인 동일문항에 대하여 제조업 종사자 8,318명을 대상으로 분석하였다. 업무 관련 유해·위험인자와 결근과의 관련성을 보면 2011년도에 비하여 2020년도에 진동, 소음, 높은 온도, 먼지 등의 흡입, 증기흡입, 화학물질 취급, 감염물질 취급에서 노출 시간 3/4 이상이 결근에 영향을 미치는 것으로 나타났다. 결론적으로 업무 관련 유해·위험요인에 대해서는 조사시기가 증가함에 따라 비노출이 증가함을 알 수 있었고 업무 관련 유해·위험요인의 노출 시간이 결근에 영향을 미친다는 것을 확인할 수 있었다.

A case report of embryo transfer with air-transported fresh bovine embryo produced by multiple ovulation in Hanwoo

  • Sang-Yup Lee;Seong-Eun Heo;Won-Jae Lee
    • 한국동물생명공학회지
    • /
    • 제38권2호
    • /
    • pp.84-88
    • /
    • 2023
  • Because multiple ovulation embryo transfer (MOET) in cattle includes several benefits such as wide spreading of genetically superior offspring for long distance, this biotechnological method has been widely applied to Hanwoo. When the recipients are not stayed close after embryo recovery from donor, the embryos are moved to other farms via several vehicles (car, train, and airplane). However, air travel induces lesser oxygen level, increased vibration, lower air pressure, higher noise, and increased exposure of cosmic radiation to living things than ground level. It was still unknown that fresh embryos obtained from multiple ovulation of Hanwoo could maintain their fertility after being transported via air plane, the present case report introduced a clinical case of MOET in Hanwoo after shipping fresh embryos via air transportation. The donor was multi-ovulated via follicle-stimulating hormone series of injection, which was followed by a gonadotrophin-releasing hormone injection and artificial insemination twice. The embryos were recovered by the uterine flushing, packed in ministraws, transported to recipients for 6 h including 1 h air flight, and then transferred to the synchronized recipients. During pregnancy diagnosis of early gestation period, 5 of 7 recipients (71.4%) presented no heat signs and showed fetal sacs with fluid under transrectal ultrasonography. After normal gestation period, all recipients naturally delivered healthy calves (male n = 2 and female n = 3) without abortion, stillbirth, and premature birth. The present case report indicated that transportation of fresh embryos for MOET via domestic flight in Korea did not affect to their fertility.