• 제목/요약/키워드: The maximum heat flow rate

검색결과 219건 처리시간 0.024초

정상유동에서 유동형 단엽폴리머 인공심장판막의 수력학적 성능평가 (Hydrodynamic Investigation of a Floating-type Monoleaflet Polymer Heart Valve under Steady Flow Condition)

  • 박복춘;김준우;백병준;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 춘계학술대회
    • /
    • pp.241-246
    • /
    • 1995
  • An experimental investigation was performed under steady flow condition to assess hydrodynamic performance of floating-type monoleaflet polymer valves (MLPV) with different leaflet thickness. The St. Jude Medical valve (SJMV) was also used for comparison tests. Pressure drops of MLPVs are larger than those for other types of polymer valves and mechanical valves. Furthermore, the thicker is the leaflet thickness of a polymer valve, the larger arc the corresponding press drop. The velocity profiles for MLPV reveal a large reversed flow region downward to the valve position. The maximum wall shear stresses of MLPVs at a flow rate of 30 l/min are in the range $54-130\;dyn/cm^2$, and the corresponding maximum. Reynolds shear stresses are in the range of $100-500\;dyn/cm^2$, respectively. Both arc beyond the allowable limit clinically. In contrast, floating-type monoleaflet polymer valves show better hydrodynamic performance in leakage volume. From the designing point of view, it can be concluded that the optimum thickness of leaflet for better hydrodynamic performance is one of the important parameters.

  • PDF

얼음 벽면의 융해율을 고려한 비평행 자연대류에서 유동의 불안정성과 천이에 관한 연구 (Instability and Transition of Nonparallel Bouyancy-Induced Flows Adjacent to an Ice Surface Melting in Water)

  • 황영규
    • 설비공학논문집
    • /
    • 제8권3호
    • /
    • pp.437-450
    • /
    • 1996
  • A set of stability equations is formulated for natural convection flows adjacent to a vertical isothermal surface melting in cold pure water. It takes account of the nonparallelism of the base flows. The melting rate is regarded as a blowing velocity at the ice surface. The numerical solutions of the linear stability equations which constitute a two-point boundary value problem are accurately obtained for various values of the density extremum parameter $R=(T_m-T_{\infty})/(T_0-T_{\infty})$ in the range $0.3{\leq}R{\leq}0.6$, by using a computer code COLNEW. The blowing effects on the base flow becomes more significant as ambient temperature ($T_{\infty}$) increases to $T_{\infty}=10^{\circ}C$. The maximum decrease of heat transfer rate is about 6.4 percent. The stability results show that the melting at surface causes the critical Grashof number $G^*$ and the maximum frequency of disturbances to decrease. In comparision with the results for the conventional parallel flow model, the nonparallel flow model has a higher critical Grashof number but has lower amplification rates of disturbances than does the parallel flow model. The spatial amplification contours exhibit that the selective frequency $B_0$ of the nonparallel flow model is higher than that of the parallel flow model and that the effects of melting are rather small. The present study also indicates that the selective frequency $B_0$ can be easily predicted by the value of the frequency parameter $B^*$ at $G^*$, which comes from the neutral stability results of the nonparallel flow model.

  • PDF

저온 수술 프로브용 소형 Joule-Thomson 냉동기의 설계 (Design of the miniature Joule-Thomson refrigerator as a cryoprobe)

  • 황규완;정상권;인세환
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제9권1호
    • /
    • pp.86-90
    • /
    • 2007
  • The cryoprobe used in cryosurgery should be fabricated in milimeter-order size for its practical usage. In general a miniature J-T(Joule-Thomson) refrigerator is applied to a cryoprobe. In case of the miniature J-T refrigerator, the mass flow rate of working fluid is small due to considerable friction in a minute flow path. For that reason, the miniature J-T refrigerator has a limited cooling power. To obtain the large cooling power from the J-T refrigerator, the refrigerator should have large mass flow rate and effective J-T temperature drop. These quantities are closely related to the geometry of the heat exchanger and the expansion nozzle in a cryoprobe, and are contradictory. The large mass flow rate leads to the small J-T temperature drop and vice versa in the miniature J-T refrigerator. Therefore, the optimal design of a cryoprobe to achieve maximum cooling power at fixed tube size and fixed operating temperature is required. This paper presents the design procedure of such case.

R22/R142b 혼합냉매를 사용한 열펌프의 성능 (Experimental Study on the Performance of Heat Pump Using Refrigerant Mixture R22/R142b)

  • 김민수;장세동;노승탁
    • 설비공학논문집
    • /
    • 제4권1호
    • /
    • pp.33-47
    • /
    • 1992
  • Experimental investigation on the performance of a heat pump system using refrigerant mixtures is done. The condenser and the evaporator are double pipe heat exchangers of counter flow type and the compressor is driven by a variable speed motor. The refrigerant mixture used in the experiment is R22/R142b. Experiments are performed by changing the compressor speed, composition on ratio of mixture, and the average temperatures of condenser and evaporator. The compressor work, heating capacity and the coefficient of performance are calculated. Results show that the heating capacity can be changed by varying the mass flow rate of refrigerant mixtures to meet the heating load. It is shown that the capacity control by changing the composition ratio is more effective than by changing the compressor speed. Under the condition where the external conditions are fixed and the heating loads are equal, the coefficient of performance has its maximum value near 50 : 50 mass fraction of the refrigerant mixture in this study.

  • PDF

Performance Analysis and Optimal Design of Heat Exchangers Used in High Temperature and High Pressure System

  • Kim, Yang-Gu;Choi, Byoung-Ik;Kim, Kui-Soon;Jeong, Ji-Hwan
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제11권1호
    • /
    • pp.19-25
    • /
    • 2010
  • A computational study for the optimal design of heat exchangers (HX) used in a high temperature and high pressure system is presented. Two types of air to air HX are considered in this study. One is a single-pass cross-flow type with straight plain tubes and the other is a two-pass cross-counter flow type with plain U-tubes. These two types of HX have the staggered arrangement of tubes. The design models are formulated using the number of transfer units ($\varepsilon$-NTU method) and optimized using a genetic algorithm. In order to design compact light weight HX with the minimum pressure loss and the maximum heat exchange rate, the weight of HX core is chosen as the object function. Dimensions and tube pitch ratio of a HX are used as design variables. Demanded performance such as the pressure loss (${\Delta}P$) and the temperature drop (${\Delta}T$) are used as constraints. The performance of HX is discussed and their optimal designs are presented with an investigation of the effect of design variables and constraints.

유기 플래쉬 사이클(OFC)의 열역학적 성능 특성 (Characteristics of Thermodynamic Performance of Organic Flash Cycle (OFC))

  • 김경훈;정영관;박상희
    • 한국수소및신에너지학회논문집
    • /
    • 제24권1호
    • /
    • pp.91-97
    • /
    • 2013
  • Recently a novel cycle named organic flash cycle (OFC) has been proposed which has improved potential for power generation from low-temperature heat sources. This study carries out thermodynamic performance analysis of OFC using various working fluids for recovery of low-grade heat sources in the form of sensible energy. Special attention is focused on the optimum flash temperature at which the exergy efficiency has the maximum value. Under the optimal conditions with respect to the flash temperature, the thermodynamic performances of important system variables including mass flow ratio, separation ratio, heat addition, specific volume flow rate at turbine exit, and exergy efficiency are thoroughly investigated. Results show that the exergy efficiency has a peak value with respect to the flash temperature and the optimum working fluid which shows the best exergy efficiency varies with the operating conditions.

평면식 건조기의 적정작업조건 설정에 관한 연구 (Study on The Qptimization of Operating Conditions of batch-type Grain Dryer)

  • 박경규;정창주
    • 한국농공학회지
    • /
    • 제16권4호
    • /
    • pp.3600-3610
    • /
    • 1974
  • Experimental work of batch-type dryer was conducted to develop its optimurm operating conditions by analyzing the major factors which affect the drying performance. A laboratory batch-type dryer was constructed and tested for various levels of heated-air rates, and depths of grain deposit. Tong-il rice variety having the initial moisture content of approximaely 23 per cent in wet basis was used for the experiment. The criteria selected for establishing the optimum operating condition were the drying performance rate, the thermal efficiency, and the operational cost of the dryer. The results of the study are summarized as follows: 1. The performance rate of dryer for a specific operating condition was defined as total amount of material dried per hour when the moisture content of grains in the upperlayer reaches to 16 per cent in wet basis. The optimum operating conditions as viewed in the rate of drying performance could be justified by functional realtionship between the depth of grain deposit and air flow rate. In other words, there was a definite depth of grain deposit for a given air-rate which make the dryer performance maximum. The optimum grain depth for the batch-type dryer with 3.3㎡ loading area and with the attached axial fan was about 35cm. 2. The thermal efficiency for the dryer was evaluated by the ratio of the latent heat required to evaporate the grain moisture to the heat input required to raise the ambient air-temperature to 40 degree centigrade. The optimum operating condition as viewed in term of thermal efficiency analyzed was that grater depth and lower air flow-rate may be desirable. This condition is contracted with the optimum condition as viewed by the dryer performance rate. 3. The annual operating cost of batch-type dryer was analyzed for different annual hour of use and for different operation condition. The optimum condition as viewed in terms of operating cost was almost identical to one as viewed in terms of dryer performance rate. Therefore, the most economical use of batch-type dryer for the same annual operating hours can be obtained when the dryer operated in the condition of maximum dryer performance rate. Increasing the annual operating hour may be desirable to cut down the dryer operation cost, since the annual hour of dryer use is much sensitive to the operating cost than any peractical conditions of dryer operation. 4. The most desirable operational condition as justified by combining all the criteria, dryer performance rate, thermal efficiency and annual operating cost, could be concluded to operate the dryer in the condition of maximum performance rate. The condition in general is identical to the lowest operation cost for a given annual operating hour.

  • PDF

Numerical Comparison of Thermalhydraulic Aspects of Supercritical Carbon Dioxide and Subcritical Water-Based Natural Circulation Loop

  • Sarkar, Milan Krishna Singha;Basu, Dipankar Narayan
    • Nuclear Engineering and Technology
    • /
    • 제49권1호
    • /
    • pp.103-112
    • /
    • 2017
  • Application of the supercritical condition in reactor core cooling needs to be properly justified based on the extreme level of parameters involved. Therefore, a numerical study is presented to compare the thermalhydraulic performance of supercritical and single-phase natural circulation loops under low-to-intermediate power levels. Carbon dioxide and water are selected as respective working fluids, operating under an identical set of conditions. Accordingly, a three-dimensional computational model was developed, and solved with an appropriate turbulence model and equations of state. Large asymmetry in velocity and temperature profiles was observed in a single cross section due to local buoyancy effect, which is more prominent for supercritical fluids. Mass flow rate in a supercritical loop increases with power until a maximum is reached, which subsequently corresponds to a rapid deterioration in heat transfer coefficient. That can be identified as the limit of operation for such loops to avoid a high temperature, and therefore, the use of a supercritical loop is suggested only until the appearance of such maxima. Flow-induced heat transfer deterioration can be delayed by increasing system pressure or lowering sink temperature. Bulk temperature level throughout the loop with water as working fluid is higher than supercritical carbon dioxide. This is until the heat transfer deterioration, and hence the use of a single-phase loop is prescribed beyond that limit.

온실 난방을 위한 모세관형 태양열 집열기의 성능에 미치는 유량의 효과에 관한 연구 (The Effects of Water Flow Rates on the Performance of a Capillary Tube Solar Collector for Greenhouse Heating)

  • 유영선;장유섭;홍성기;윤진하;정두호;강영덕
    • 생물환경조절학회지
    • /
    • 제5권1호
    • /
    • pp.57-64
    • /
    • 1996
  • To use effectively the solar energy in greenhouse heating, a high performance solar collector should be developed. And then the size of the solar collector and thermal storage tank should be determined through the calculation of heating load. The solar collector must be set in the optimum tilt angle and direction to take daily solar radiation maximally, and the flow rate of heat transfer fluid through the solar collector should be kept in the optimum range. In this research, the performance tests of a capillary tube solar collector were performed to determine the optimum water flow rate and the results summarized as follows. 1. The regressive equations for efficiency estimations of the capillary tube solar collector in the open loop were modeled in the water flow rate of 700-l,000 $\ell$/hr. 2. The optimum water flow rate of the solar collector was estimated by the second order polynomial regression and the maximum efficiency was 80% at the water flow rate of 850 $\ell$/hr. 3. The solar thermal storage system consisted of a capillary tube solar collector and a water storage tank was tested at the water flow rate of 850 $\ell$/hr in the closed loop, and obtained the solar thermal storage efficiency of 55.2%. 4. As the capillary tube solar collector engaged in this experiment was made of non-corrosive polyolefin tubes, its weight was as light as 1/30 of the flat plate solar collector made of copper tubes. Therefore it was considered to be suitable for the greenhouse heating system.

  • PDF

Enhancement of Absorption Performance Due to the Wavy Film of the Vertical Absorber Tube

  • Kim Jung-Kuk;Cho Keum-Nam
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제14권2호
    • /
    • pp.41-48
    • /
    • 2006
  • Absorption performance at the vertical interface between refrigerant vapor and liquid solution of $LiBr-H_{2}O$ solution was enhanced by the waves formed due to the interfacial shear stress. The present study investigated experimentally and analytically the improvements of absorption performance in a falling film by wavy film flow. The dynamic parameter was the film Reynolds numbers ranged from 50 to 150. The energy and diffusion equations were solved simultaneously to find the temperature and concentration profiles at the interface of liquid solution and refrigerant vapor. Absorption characteristics due to heat and mass transfer were analyzed for the falling film of the LiBr aqueous solution contacted by refrigerant vapor in the absorber. Absorption performance showed a peak value at the solution flow rate of $Re_{f}>100$. Absorption performance for the wavy film flow was found to be greater by approximately 10% than that for uniform film flow. Based on numerical and experimental results, the maximum absorption rate was obtained for the wavy flow caused by spring insert. The difference between the measured and the predicted results were ranged from 5.8 to 12%.