• 제목/요약/키워드: The height of wall

검색결과 894건 처리시간 0.025초

Clinical evaluation of a biphasic calcium phosphate grafting material in the treatment of human periodontal intrabony defects

  • Lee, Min-Jae;Kim, Byung-Ock;Yu, Sang-Joun
    • Journal of Periodontal and Implant Science
    • /
    • 제42권4호
    • /
    • pp.127-135
    • /
    • 2012
  • Purpose: The aim of this study was to compare the clinical outcome of open flap debridement (OFD) with a biphasic calcium phosphate (BCP) graft to that of OFD without BCP graft for the treatment of intrabony periodontal defects (IBDs). Methods: The study included 25 subjects that had at least one intrabony defect of 2- or 3-wall morphology and an intrabony component ${\geq}4$ mm as detected radiographically. Subjects were randomly assigned to treatment with (BCP group, n=14) or without BCP (OFD group, n=11). Clinical parameters were recorded at baseline and 6 months after surgery and included the plaque index, gingival index, probing depth (PD), clinical attachment level (CAL), and gingival recession (REC). A stringent plaque control regimen was enforced for all of the patients during the 6-month observation period. Results: In all of the treatment groups, significant PD reductions and CAL gains occurred during the study period (P<0.01). At 6 months, patients in the BCP group exhibited a mean PD reduction of $3.7{\pm}1.2$ mm and a mean CAL gain of $3.0{\pm}1.1$ mm compared to the baseline. Corresponding values for the patients treated with OFD were $2.5{\pm}0.8$ mm and $1.4{\pm}1.0$ mm, respectively. Compared to OFD group, the additional CAL gain was significantly greater in the patients in BCP group (P=0.028). The additional PD reduction was significant for the BCP group (P=0.048). The REC showed a significant increase in both groups, and the amount of recession was significantly smaller in the BCP group than OFD group (P=0.023). In radiographic evaluation, the height of the bone fill in the BCP group was significantly greater than OFD group. Conclusions: The clinical benefits of BCP found in this study indicate that BCP may be an appropriate alternative to conventional graft materials.

Anatomical Morphometric Study of the Cervical Uncinate Process and Surrounding Structures

  • Kim, Sung-Ho;Lee, Jae Hack;Kim, Ji Hoon;Chun, Kwon Soo;Doh, Jae Won;Chang, Jae Chil
    • Journal of Korean Neurosurgical Society
    • /
    • 제52권4호
    • /
    • pp.300-305
    • /
    • 2012
  • Objective : The purpose of this study is to elucidate the anatomic relationships between the uncinate process and surrounding neurovascular structures to prevent possible complications in anterior cervical surgery. Methods : Twenty-eight formalin-fixed cervical spines were removed from adult cadavers and were studied. The authors investigated the morphometric relationships between the uncinate process, vertebral artery and adjacent nerve roots. Results : The height of the uncinate process was 5.6-7.5 mm and the width was 5.8-8.0 mm. The angle between the posterior tip of the uncinate process and vertebral artery was $32.2-42.4^{\circ}$. The distance from the upper tip of the uncinate process to the vertebral body immediately above was 2.1-3.3 mm, and this distance was narrowest at the fifth cervical vertebrae. The distance from the posterior tip of the uncinate process to the nerve root was 1.3-2.0 mm. The distance from the uncinate process to the vertebral artery was measured at three different points of the uncinate process : upper-posterior tip, lateral wall and the most antero-medial point of the uncinate process, and the distances were 3.6-6.1 mm, 1.7-2.8 mm, and 4.2-5.7 mm, respectively. The distance from the uncinate process tip to the vertebral artery and the angle between the uncinate process tip and vertebral artery were significantly different between the right and left side. Conclusion : These data provide guidelines for anterior cervical surgery, and will aid in reducing neurovascular injury during anterior cervical surgery, especially in anterior microforaminotomy.

한탄강(漢灘江) 일대(一帶)의 지표기복(地表起伏)에 관한 정보(情報) (A Study on the Information of Landforms in the vicinity of the Hantan River)

  • 김주환
    • 동굴
    • /
    • 제72호
    • /
    • pp.19-30
    • /
    • 2006
  • 본 연구의 목적은 한탄강유역의 지질 및 지형정보를 제공하려는 것이다. 추가령 열곡과 관련이 있는 이 지역에는 선지형, 원지형, 차지형으로 구분하는 것이 가능하다. 또한 단구의 분포도 연구지역을 통하여 잘 나타난다. 결론적으로 보면 한탄강 유역에는 화산활동에 의해 용암대지가 형성되었으며 이 지역에 나타나는 백의리층은 용암층 밑의 하상 역을 의미한다. 하계패턴의 발달은 불안정하며, 분기율, 하천길이비율 등은 다른 하천에 비해 낮다. 단구의 높이는 $5{\sim}25m$ 정도이고 대부분이 충적단구이다. 직탕폭포지역은 기반암인 화강암위에 용암대지가 덮혀있다 구침식면지역은 수평용암대지 보다 경사가 급하나 고석정 지역의 지형은 직탕폭포 부근과는 다르다. 기반암이 화강암인 것은 직탕폭포 주변과 동일하나 하천의 횡단면이 비대칭적인 것이 특징이다.

열전도성 플라스틱을 이용한 김치냉장고용 열교환기에 관한 연구 (Research on the Heat Exchanger for Kimchi Refrigerator Using Thermal Conductive Plastic)

  • 강태호;백정용;권용하;김인관;김영수;신대식;박재홍
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권4호
    • /
    • pp.407-416
    • /
    • 2005
  • The kimchi refrigerator is the electric home appliance which is used for the maturing and preserving of the kimchi in domestic and foreign market. The kimchi refrigerator is composed in 3 main parts as insulation. kimchi container, machinery room. The heat exchanger of kimchi refrigerator is made of aluminum and the other parts are made of steel and polymer. Also, kimchi refrigerator is expensive and heavy as compared with same class of refrigerator until now. In the present study, the possibility to replace heat exchanger from aluminum to thermal conductive plastic was analyzed and experimented. The thermal conductive plastic has $10{\sim}100$ times heat conductivity than that of normal plastic. It is known that heat transfer process is dependent not only conduction but convection or radiation. Thermal conductivity of the applied material in this research is over than 2 W/mK, thermal conductivity doesn't play a vital role on heat transfer. In this study, temperature is the most important parameter on the kimchi refrigerator and the temperature of kimchi refrigerator's heat exchanger was measured and compared with the temperature calibrated by CFD analysis on the inside wall of the kimchi refrigerator. It is important to keep constantly the inside temperature of the Kimchi refrigerator. Besides numerical analyses for the new thermal conductive plastic for heat exchanger were executed with the various height of evaporation tube. A series of experiments were conducted to compare the performance of the two heat exchanger made of aluminum and thermal conductive plastic at the same condition and certified the possibility of the thermal conductive plastic. According to these results, it was confirmed that the conventional aluminium heat exchanger can be replaced by thermal conductive plastic successfully.

한국 전통건축미(美)와 전통가구에 내재된 자연미(美)의 유기적 특징 연구 (Study of the organic characteristics between Korean traditional aesthetic of architecture and the natural beauty being intrinsic in traditional furniture)

  • 임광순
    • 한국가구학회지
    • /
    • 제20권5호
    • /
    • pp.504-516
    • /
    • 2009
  • Korean traditional architecture has been carried out in the manner that it harmonized surrounding natural environments and never disturbed them in the scale which did not overwhelm the nature, based on the view of architecture predicated on Yin Yang School. The exposed grain of the wood like pillar, hinge and house rafte, the linear expression of the construction material and the formation between the window and door monopolizing the front side presented a harmony with the nature showing the linear structure. Furthermore the ceiling is low due to the sit life style thanks to the ondol (Korean under-floor heating system and the furniture was made in simple manner to utilize the space as large as possible, for the interior was narrow and close, and also the furniture placing in the middle of the room was movably manufactured to improve the room space. Like this Korean traditional furniture was close associated with the low height and simplicity and harmonized with the blank of the wall accordingly, and it characterized linear & planar natural beauty focusing on the simple and refined unique beauty, because it was made in a good harmony with the interior utensils. This study has presented that the organic characteristics of Korean traditional aesthetic of architecture and the natural beauty being intrinsic in traditional furniture have a mutual relation on the basis of not only the visual recognition, also the aesthetic of naturalism made of the natural material, the constructional naivety as a frame method and the linear & planar formative beauty shown in appearance.

  • PDF

고층건물의 필로티 형태별 피크풍압계수 특성에 대한 연구 (A Study on the Characteristics of Peak Wind Pressure Coefficient according to Type of Pilotis of High-rise Buildings)

  • 김근호;유장열;김영문;유기표
    • 대한건축학회논문집:구조계
    • /
    • 제34권4호
    • /
    • pp.51-58
    • /
    • 2018
  • Various types of pilotis frames are used on the ground level of high-rise buildings. In some cases, their interior finishing is destroyed by strong winds or typhoons. In the case of a corner pilotis, the peak wind pressure coefficients were greater on the ceiling than they were on the wall for all wind angles. Specifically, on the ceiling portion of a pilotis, the coefficient increased gradually from the outside to the inside in a symmetrical form that centered on the corner edge. However, the minimum peak wind pressure coefficient was greater at the center of the ceiling than it was on the edge of the pilotis' interior. Additionally, the higher the height of the pilotis, the greater the peak wind pressure coefficient was due to the turbulent flow that occurs within a pilotis. In this study, we evaluated peak wind pressures to design an interior finishing for the end edge of a pilotis and for corner piloti. In terms of specific wind angles, the maximum and minimum peak wind pressure coefficients were each observed. They were a maximum of $320^{\circ}$ and a minimum of $270^{\circ}$ for corner piloti and $0^{\circ}$ and $270^{\circ}$, respectively, for the end edge piloti.

60Hz 고압 송전선로의 자기장 발생범위에 대한 GIS 적용 방안에 대한 연구 (Study about the Applicable Plan of GIS on Range of Magnetic Field Emitted from 60 Hz Powerline)

  • 홍승철;최성호;김윤신;박재영
    • 환경영향평가
    • /
    • 제15권4호
    • /
    • pp.271-277
    • /
    • 2006
  • In this study, we investigated the applicable plan of GIS on the environmental impact assessment of 60 Hz Powerline. So we assessed distance data based on calculations by use of 2D and 3D Geographical information systems(GIS) and distance data based on measurements on 1: 5000 maps accord with on site distance measurements to use input data for calculating magnetic field. One hundred eight of the on site measured addresses were selected from residences. The data were achieved by measuring the distance between residence and power line on maps with scales of 1: 5000. The digital map was obtained from National Geographic Information Institute with scales of 1: 5000, and we made 2D and 3D map. Correlation analyses were performed for statistical analyses. For the 3D GIS versus on site comparison of different exposure categories, 70 of 108 measurements were assigned to the correct category. Similarly for 2D GIS versus on site comparison, 71 of 108 were correctly categorized. When comparing map measurement with on site measurement, 62 of 108 were correctly categorized. When the correlation analysis was performed, best correlation was found between 3D GIS and on site measurements with r = 0.84947 (p<0.0001). The correlation between map and on site measurement yielded an r of 0.76517 (p<0.0001). Since the GIS measurements and map measurement were made from the center point in the building and the on site measurements had to be made from the closest wall on the building, this might introduce and additional error in urban areas. The difference between 2D and 3D calculations were resulted from the height of buildings.

고압 호스에서 굽힘의 각도가 압력 변화에 미치는 영향에 대한 수치해석적 연구 (Numerical Study on The Effect of Bending Angle on Pressure Change in High Pressure Hose)

  • 홍기배;김민석;유홍선
    • 한국산업융합학회 논문집
    • /
    • 제25권1호
    • /
    • pp.61-70
    • /
    • 2022
  • Fire damage time in high-rise buildings and wildland fire increasing every year. The use of high-pressure fire pumps is required to effectively extinguish fires. Reflecting the curvature effect of the fire hose occurring at the actual fire fighting site, this study provides a database of pressure drop, discharge velocity and maximum discharge height through C FD numerical analysis and it can provide using standards for fire extinguishing. Two Reynolds numbers of 200000 and 400000 were numerically analyzed at 0° -180° bending with water of 25℃ as a working fluid in hoses with a diameter of 65mm, a length of 15m, and a radius of curvature of 130mm. Realizable k-ε turbulence model was used and standard wall function was used. The pressure drop increases as the bending angle increases, and the maximum value at 90° and then decreases. The increasing rate is greater than the decrease. The velocity of the secondary flow also decreases after having the maximum value at 90°. The decreasing rate is greater than the increase. The turbulent kinetic energy increases to 120° and decreases with the maximum value. Pressure drop, velocity of the secondary flow, and turbulence kinetic energy are measured larger in the second bending region than in the first bending region.

Heating and Cooling Energy Conservation Effects by Green Roof Systems in Relation with Building Location, Usage and Number of Floors

  • Son, Hyeong Min;Park, Dong Yoon;Chang, Seong Ju
    • KIEAE Journal
    • /
    • 제14권2호
    • /
    • pp.11-19
    • /
    • 2014
  • Building energy consumption takes up almost 25% of the total energy consumption. Therefore, diversified ways, such as improving wall and window insulation, have been considered to reduce building energy consumption. Recently, green roof system has been explored as an effective alternative for dealing with reducing heating and cooling energy, thermal island effect and improving water quality. However, recent studies regarding a green roof system have only focused on building energy reduction without considering the applied usage, location, and story of the green roof system. Therefore, this study pays attention to the heating and cooling energy in relation to the applied usage, location, and story of a green roof system for investigating its impact on energy reduction. The result of simulations show that the reduction in heating energy consumption is higher when applied to Cherwon-gun province which has a continental climate condition, compared to the city of Busan that is distinguished by its warm climate. Cooling energy saving turns out to be higher when the green roof system is applied to Busan in comparison with Cherwon. As for the applied usage or function of the building, residential space acquires the highest heating and cooling energy saving effect rather than commerce, educational or office space because of HVAC's running time based on usage. When it comes to the story of the green roof, both heating and cooling energy saving become the highest when the green roof is applied to single-storied buildings. The reason is that single story building is affected by the ground largely. Generally, the variations of heating energy consumption are larger than the cooling energy consumption. The outcome of the simulations, when a green roof system is applied, indicates that the energy consumption reduction rate is dynamically responding to the applied usage, location, and story. Therefore, these factors should be counted closely for maximizing the reduction of energy consumption through green roof systems.

Micro-Channel형 열교환기에 부착된 핀의 열접촉저항이 열전달 특성에 미치는 영향 (Effect of Thermal Contact Resistence on the Heat Transfer Characteristics of Air Flow around the Finned Micro-Channel Tube for MF Evaporator)

  • 박용석;성홍석;성동민;서정세
    • 한국기계가공학회지
    • /
    • 제20권11호
    • /
    • pp.121-126
    • /
    • 2021
  • In this study, the effect of thermal contact resistance between pin-channel tubes on the heat transfer characteristics was analytically examined around the channel tubes with the pins attached to two consecutive arranged channel pipes. The numerical results showed that the heat transfer coefficient decreased geometrically as the thermal contact resistance increased, and the corresponding temperature change on the contact surface increased as the thermal contact resistance increased. The thinner the pin, the more pronounced the geometric drop in the heat transfer coefficient. It was confirmed that the higher the height of the pin, the higher was the heat transfer coefficient, however, the greater the size of the thermal contact resistance, the smaller was the heat transfer coefficient. It was found that the temperature change in the inner wall of the channel tube did not significantly affect the heat transfer characteristics owing to the thermal contact resistance. Furthermore, the velocity of air at the entrance of the channel tube was proportional to the heat transfer coefficient due to a decrease in the convective heat resistance corresponding to an increase in the flow rate.