• Title/Summary/Keyword: The fire safety

Search Result 3,674, Processing Time 0.025 seconds

A Study on the Life Risk Assessment of Ship's Engine Room Fire (기관실화재 인명위험성평가에 관한 연구)

  • Han, Sang-Kook;Cho, Dae-Hwan;Park, Chan-Soo
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2006.11a
    • /
    • pp.283-289
    • /
    • 2006
  • This study is a preparation for the application of FSA (Formal Safety Assessment) to the fire safety of ships. FSA is the new-fashioned methodology proposed to prevent ships from the accidents. To make a base of the fire safety assessment about ship's fire protection design and Classification Society rule, statistical informations for the fire safety engineering are investigated. From results, the necessity of new criterion for ship's fire safety design, the need to study the human behavior in the evacuation from fire, and the development of new fire progress model considering special situations in ships are acknowledged.

  • PDF

A Study on the Performance and the Improving Methods of the Building Fire Compartment under the Domestic Fire Safety Regulations (국내 방화규정에 따른 건축물 방화구획 성능 및 개선방안에 관한 연구)

  • Chun, Woo-Young;Lee, Kwang-Won;Lee, Ji-Hee;Kim, Wha-Jung
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.19-24
    • /
    • 2008
  • Recently, the buildings have gradually become higher, more massive and more complex with high growth of economy and varieties of the patterns of people's living. Therefore we study a performance and Improving Methods of the fire compartment as a measure to minimize the damage of the people and property from the fire. Currently, under the economic crisis situation, we do not consider about prevention of disaster safety enough; safety investment evasion, safety carelessness, and management relaxation etc. Also in the aspect of regulation system, industrial technology and plan engineering, Korean techniques of preventing fire disasters are far behind of other advanced nations. At this point, we are in need of improving about it. When considering like this situation, we need more studies on the practical improvement in order to assure fire prevention for buildings. The fire compartment prevent from magnifying the fire to the wide area by compartment into specific area. From this, it is possible to minimize fire damage and property and secure emergency exit for life safety. This fire compartment has primary function to extinguish fire easily, and the openings and penetrations are important passage which makes the smoke and fire go away from the fire area to the contiguous space. This study suggests improving methods of domestic fire compartment efficiency standard through comparative analysis of overseas advanced provision and domestic provision about base element of the building fire prevention.

  • PDF

A Study on Cable Functional Failure Temperature by Exposed Fire in Nuclear Power Plants (원전 노출 화재시 케이블 기능상실 온도에 관한 연구)

  • Kim, Doo-Hyun;Lim, Hyuk-Soon
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.5
    • /
    • pp.41-45
    • /
    • 2011
  • The fire event occurred in fire proof zone often causes serious electrical problems such as shorts, ground faults, or open circuits in nuclear power plants. These would be directed to the loss of safe shutdown capabilities performed by safety related systems and equipments The fire event can treat the basic design principle that safety systems should keep their functions with redundancy and independency. In case of a cable fire, operators can not perform their mission properly and can misjudge the situation because of spurious operation, wrong indication or instrument. These would deteriorate the plant capabilities of safety shutdown and make disastrous conditions. In this paper, the cables of the representative nuclear power plant in korea is selected and the cable functional failure temperature by exposed fire using Cable Response to Live Fire(CAROLFIRE) is studied. It is expected that the results are very useful to know the cable failure temperature by exposed fire. We confirmed the safety and integrity of the cable by exposed fire and those results will use the based data of cable exposed fire characteristics.

A New Approach to Statistical Analysis of Electrical Fire and Classification of Electrical Fire Causes

  • Kim, Doo-Hyun;Lee, Jong-Ho;Kim, Sung-Chul
    • International Journal of Safety
    • /
    • v.6 no.2
    • /
    • pp.17-21
    • /
    • 2007
  • This paper aims at the statistical analysis of electrical fire and classification of electrical fire causes to collect electrical fires data efficiently. Electrical fire statistics are produced to monitor the number and characteristics of fires attended by fire fighters, including the causes and effects of fire so that action can be taken to reduce the human and financial cost of fire. Electrical fires make up the majority of fires in Korea(including nearly 30% of total fires according to recent figures), The incorrect and biased knowledge for electrical fires changed the classification of certain types of fires, from non-electrical to electrical. It is convenient and required to develop the standardized form that makes, in the assessment of the cause of electrical fires, the fire fighters directly ticking the appropriate box on the fire report form or making an assessment of a text description. Therefore, it is highly recommended to develop electrical fire cause classification and electrical fire assessment on the fire statistics in order to categorize and assess electrical fires exactly. In this paper newly developed electrical fire cause classification structure, which is well-defined hierarchical structure so that there are not any relationship or overlap between cause categories, is suggested. Also fire statistics systems of foreign countries are introduced and compared.

A Study on the Comparison of Building Egress Safety Rule in Countries (건축물의 피난안전에 관한 국가간 기준 비교 연구)

  • 박재성;윤명오;이용재
    • Fire Science and Engineering
    • /
    • v.16 no.2
    • /
    • pp.27-32
    • /
    • 2002
  • As a result of increase of high-rise building and complex building in cities, fire damage become larger and complicated. However, law and standards in connection with life safety in the fire is deficient in safety performance and the institution of fire is divided into two parts : the building law and the fire law. The aim of this research is to compare with egress safety rule in advanced countries and to analyze the national standard of egress safety by investigating research data in order to make fire safety rule more effective. On the basis of this analysis, this research also suggested that reform measures should make egress safety in the fire.

A Study on the Safety Measures of Camping Ground Fire (야영장 화재 안전대책에 관한 연구)

  • Choi, Ji-Hun;Choi, Don-Mook
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.1
    • /
    • pp.57-64
    • /
    • 2016
  • The leisure life pattern of people is changing to a familial and enthusiastic way that eventually develops the camping culture. Thus, the number of campers and the size of camping market have been dramatically increased due to significant expansion of camping people. However, many camp grounds and facilities are operating without a proper registration by government rules and regulations. In addition, many of electronic and gas equipment and tools are not used in a safe way and in a safety regulatory boundary. Therefore, campers at the camping ground is situated in a fire and safety hazard. In addition, there is limitation in rules and regulations associated with camping ground safety and fire. This study analyzed the fire and hazard guidelines and rules regulations of developed countries of campground and compared them to the current situation in South Korea. Therefore, this study is to develop a safety and fire hazard guidelines and rules and regulations related to camp ground operation, gas and electronic equipment operation and management. The study will eventually reduce the future fire and safety incidents in a campground in South Korea.

Effect of Fire Safety Education Based on the Theory of Planned Behavior on the Fire Safety Behavior of Care Worker Trainees (계획된 행동 이론을 적용한 화재안전교육이 요양보호사 교육생들의 화재안전행동에 미치는 효과)

  • Byeon, Do-Hwa
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.147-155
    • /
    • 2019
  • This study was a quasi-experimental research of a non-equivalent control group and non-synchronized design for analyzing the effects of fire safety education on care worker trainees. The subjects of the study were care worker trainees of the S Care Worker Institution: 57 trainees with 28 in the experimental group, and 29 in the control group. The research period was from May 21 to June 14, 2018 and the experiments focusing on fire safety education were performed once per week for a total of four times over the research period. The data were then analyzed using a ${\chi}^2-test$ and t-test. The results showed that fire safety education is an effective source of education for increasing the knowledge on fire safety, attitudes towards fire safety, perceived behavioral control on fire safety, behavioral intention on fire safety, and fire safety behavior in addition to being incredibly useful in practicing fire safety behaviors throughout their daily lives. On the other hand, the subjective norms on fire safety did not show any significant differences. Therefore, this paper suggests a follow-up study that should focus on analyzing the effects of the subjective norms on fire safety.

A Study on the Fire Organization of the Effectiveness Life Safety Services (소방조직의 효과적인 생활안전서비스에 관한 연구)

  • Chae, Jin;Woo, Seong-Cheon;Go, Gi-Bong
    • Fire Science and Engineering
    • /
    • v.27 no.4
    • /
    • pp.47-55
    • /
    • 2013
  • The importance of fire safety services has increased expanding its services into prevention of danger and the reinforcement of safety services. The purpose of this study is to suggest a way for effective safety service by surveying fire fighters and residents of Gyeonggi Province and examining theories of safety services and actual status of 119 safety units. This study suggests the use of social capital by local community, establishment of cooperation between organizations, supports by citizens, cooperative activities by organizations, difference between emergency report and non emergency report and social safety net role of safety fire services.

A Study on the Fire Safety Measures of Korean Nuclear Power Plants (국내 원자력발전소 화재안전 대책에 관한 연구)

  • 김학중;손봉세;허만성
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2003.04a
    • /
    • pp.259-264
    • /
    • 2003
  • The fire protection system of Nuclear Power Plants(NPPs) is an integrated system that is applied multi-field technology. So, it needs synthetic design and analysis, that is, the plan of fire protection, fire compartment, fire detection, fire suppression, and success of safety shut down, etc. In case of a fire in NPPs, secure the safety of reactor and minimize the radioactivity contamination. For this purpose, perform the fire risk analysis and make up the deducted problem through the improvement of design or the change of operation process.

  • PDF

A practical approach for fire safety design of fire-resistant steel members

  • Li, Guo-Qiang;Ding, Jun;Sakumoto, Y.
    • Steel and Composite Structures
    • /
    • v.5 no.1
    • /
    • pp.71-86
    • /
    • 2005
  • Based on the test data of Nippon Steel Corporation, the formulas for calculating mechanical properties of fire-resistant (FR) steel at elevated temperatures have been established. A practical approach for fire safety design of FR steel members, including axially compressed members, flexural members and eccentrically compressed members, is developed in this paper. Compared with the full-scale specimen experiments and FEM numerical analysis, this practical approach for fire safety design of FR steel members is demonstrated to be effective and precise.