• Title/Summary/Keyword: The dry wall

Search Result 314, Processing Time 0.034 seconds

Development of Fire Extinguishing System Suitable for Unmanned Engine Room of a Small Ship (소형선박 기관실화재에 대한 자동소화시스템 개발연구)

  • Kim, Dong-Suk;Kwark, Ji-Hyun;Kang, Dae-Sun;Son, Bong-Sei
    • Fire Science and Engineering
    • /
    • v.20 no.3 s.63
    • /
    • pp.96-100
    • /
    • 2006
  • A study developing the dry powder fire extinguishing system inside the simulated machinery spaces of small ship was performed. Fire tests were conducted inside the compartments having volume $8m^3,\;4.5m^3\;and\;2.9m^3$ respectively. The openings and fans were established on the walls of the compartments. Diesel oil was used for the test fuel. In addition fire extinguishing nozzles using dry powder were installed downward at ceiling and horizontally at the wall or conner. All fires in the test were extinguished under system activation and there was no reignition.

Investigation of Coke Formation in Dry Methane Reforming over Nickel-based Monolithic Catalysts

  • Pornruangsakun, Pongsakorn;Tungkamani, Sabaithip;Ratana, Tanakorn;Phongaksorn, Monrudee;Sornchamni, Thana
    • International Journal of Advanced Culture Technology
    • /
    • v.3 no.1
    • /
    • pp.31-38
    • /
    • 2015
  • Coking accumulations via dry methane reforming (DMR) over 10NAM monolithic catalyst and pelletized catalyst was investigated. 10NAM catalyst was synthesized and coated on a wall of monolithic reactor. Pelletized catalyst of 10NAM was also prepared for the comparison. Consequently, catalyst was characterized by BET, $H_2-TPR$ and $H_2-TPD$. The catalytic reaction was undergone at $600^{\circ}C$ under atmospheric pressure and $CH_4$ to $CO_2$ reactant ratio of 1:2. The coking formation over spent catalyst was then carried out in the hydrogen flow using temperature programmed technique (TPH). According to the results, DMR over 10NAM monolithic catalyst exhibits a minimized coking formation comparing to the use of pelletized catalyst. This could be attributed to a prominent heat transfer efficiency of the monolithic catalyst.

Shear Strength Characteristics of Short-fiber Reinforced Soil for the Application of Retaining Wall Backfill (옹벽 배면토체 적용을 위한 단섬유 보강토의 전단강도 특성)

  • Park, Young-Kon;Cha, Kyung-Seob;Chang, Pyoung-Wuck
    • Proceedings of the KSR Conference
    • /
    • 2003.10b
    • /
    • pp.73-78
    • /
    • 2003
  • As a fundamental study to develop the retaining wall of new type, short-fibers are mixed with soils and a series of compaction tests and triaxial compression tests for short-fiber reinforced soils are performed. From the results of compaction tests, optimum moisture content is increased and maximum dry unit weight is decreased with fiber mixing ratio. When 60mm fibrillated fiber of 0.2$\%$ mixing ratio is added to SM soil, strength increment of short-fiber reinforced soil is above 1.2 times compared to soil only. Strength increment shows maximum value for composite reinforced soil, namely, soil+short-fiber+planar reinforcement. But in case of mixing with ML soil and short-fiber, the strength of short-fiber reinforced soil is nearly the same as soil only. Internal angle of short-fiber reinforced soil is increased about $2\~3$ degrees and cohesion is also increased above 10kPa compared to soil only. Therefore, it is judged that short-fiber is a good material to strengthen the soil.

  • PDF

Study on the Fire Resistance of Light Weight Inorganic Polymer Concrete Panel Wall (Inorganic Polymer Concrete를 이용한 경량패널의 내화특성에 관한 실험적 연구)

  • Hwang, Ji-Soon;Kim, Woo-Jae;Kim, Dae-Hoi;Park, Dong-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.205-206
    • /
    • 2011
  • Inorganic Polymer Concrete, a type of Alkali activated cement and concrete, is known for various excellent performances, especially for better performance in the area of high temperature heat resistance(thermal characteristic) than portland cement concrete.In this study, light weight concrete panel was manufactured using this Inorganic Polymer Concrete and then evaluated for fire resistance with a small-scale heating furnace. Since the result showed excellent fire resistance, it is considered usable for manufacturing fire resistant concrete panel wall.

  • PDF

A RADIOGRAPHIC STUDY ON THE EXPERIMENTAL LESIONS OF THE MAXILLARY SINUS (상악동 실험병소에 관한 방사선학적 연구)

  • Kim Young-Il;Kim Jae-Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.25 no.1
    • /
    • pp.39-49
    • /
    • 1995
  • This study was performed to determine the each location of lesions in the maxillary sinus and to evaluate the relationship between the floor of the antrum and the apical regions of teeth by the comparison of the panoramic view and panoramic sinus view. For this study, experimentally with two dry skulls, jelly balls of 8mm and 15mm in diameter containing a short wire for the radiopacity similar to the cyst and clinically 5 patients having mucosal cyst in the antrum and 10 patients having periapical lesion of molar were used. The experimental cystic lesions were simulated with jelly ball being attached in turn to each wall of the antrum. The radiolucent periapical lesions of upper molars were formed by using round bur and the radiopaque periapical lesions were simulated by filling the former lesions with lead foil. Each panoramic view and each panoramic sinus view of the experimental lesions and patients were obtained by using panoramic machine and analyzed. The obtained results were as follows : 1. On the panoramic sinus view, the innominate line was approximately coincided with the most lateral portion of the antrum and the posterior wall appeared as the narrow area at the mesial side of the innominate line. The anterior wall occupied totally the mesial side of the innominate line, and the medial wall occupied the mesial half of the antrum. 2. In all cases of experimental cystic lesion attached to each wall of the antrum, the location of each lesion was able to be determined by applying Tube shift technic. 3. The palatal root and mesiobuccal root of the molar appeared as being transposed each other mesiolaterally on the panoramic and panoramic sinus views. 4. The panoramic sinus view was superior to the panoramic view in revealing the relationship between the floor of the antrum and the periapical lesion.

  • PDF

Histological Changes of Tissues and Cell Wall of Rice Straw Influenced by Chemical Pretreatments

  • Wang, Jia-Kun;Chen, Xiao-Lian;Liu, Jian-Xin;Wu, Yue-Ming;Ye, Jun-An
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.21 no.6
    • /
    • pp.824-830
    • /
    • 2008
  • Sodium hydroxide (SH) or ammonium bicarbonate (AB) were applied to rice straw to investigate the effects on histological change of stem tissue or cell wall before and after in sacco degradation using a scanning electron microscope (SEM) and a transmission electron microscope (TEM). The SEM revealed that, the parenchyma and vascular bundles were distorted by treatment with SH at 30 or 45 g/kg straw dry matter. Faultage between phloem of large vascular bundles and parenchyma occurred with further increasing SH to 60 or 75 g/kg. The cell wall in these stem tissues was crimped when observed by TEM. However, only parenchyma and large vascular tissues were slightly distorted in AB-treated stem. For untreated and AB-treated stems, the initiation of observable ruminal degradation of cell wall was prolonged from 12 h for inner parenchyma to 24 h for sclerenchyma and to 48 h for phloem of small vascular bundles, while the outer epidermis was intact even at 72 h. For SH-treated stem, however, the cell wall from all of the investigated tissues, epidermis, small vascular bundles, sclerenchyma, and parenchyma started to be degraded at 12 h incubation. These results indicate that SH treatment contracts rice straw stem leading to an improvement in rumen degradation, and that the degradation of SH-treated stem is bilateral from inner and outer surface simultaneously.

Adsorption of $\textrm{Pb}_{2+}$ in the components of bacterial cell membrane

  • Kim, Mal-Nam
    • Journal of Microbiology
    • /
    • v.33 no.4
    • /
    • pp.278-282
    • /
    • 1995
  • S. epidermidis cell was fractionated into cell wall, cell membrane and cytoplasm. The cell membrane adsorbed the most abundant $\textrm{Pb}_{2+}$ per unit dry weight of the three fractions tested. Adsorption behavior of $\textrm{Pb}_{2+}$ in lipid and protein, which are the main components of the cell membrane, indicated that phosphatidylethanolamine and phosphatidylinositol having phosphoryl group and gangliosides containing carboxyl groups adsorbed much more $\textrm{Pb}_{2+}$ than triglycerides lacking any chargeable functional groups. Protein purified from cell membrane adsorbed larger amount of $\textrm{Pb}_{2+}$ than total native cell membrane or cell membrane lipid.

  • PDF

Seepage-induced behaviour of a circular vertical shaft (침투를 고려한 원형수직터널 거동특성 연구)

  • Kim, Do-Hoon;Lee, Kang-Hyun;Lee, In-Mo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.13 no.6
    • /
    • pp.431-450
    • /
    • 2011
  • When a circular vertical shaft is constructed below the groundwater level, additional forces caused by groundwater flow besides horizontal effective stresses will act on the wall. The inward direction of the groundwater flow will be inclined to the vertical wall and its direction will change depending on the wall depth. In this paper, to figure out the effect of seepage forces acting on the circular vertical shaft, the slope of the inclined flow varying with the depth is divided into vertical and horizontal components to derive the coefficient of earth pressure considering the seepage pressure and to obtain the vertical stress by taking the seepage pressure into account. The control volume in this study is assumed to be the same with that of the dry ground condition within which the earth pressure is acting on the wall by the creation of the plastic zone during shaft excavation. An example study shows that the vertical stress increases by about 1.4 times and the horizontal earth pressure increases up to 2.5 times compared to the dry ground condition. The estimated values from the proposed equation considering seepage forces and the calculated values from numerical analysis with "effective stress plus seepage force" show similar values, which verifies appropriateness of the proposed equation to estimate the earth pressure under the seepage condition.

A study for the performance evaluation of concrete block assembly wall without using mortar (무모르타르로 건식조립된 콘크리트블록 벽체의 성능평가 연구)

  • Lee, Joong-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.7
    • /
    • pp.203-210
    • /
    • 2019
  • A recent earthquake on the Korean Peninsula caused much damage to masonry buildings, and research on performance evaluation has been underway. A masonry building is generally constructed using wet construction and is affected by temperature, which reduces the efficiency of the construction. In this study, we propose a dry construction technique for assembling concrete blocks without using mortar and evaluated its performance through experimental and analytical research. To evaluate the performance, experiments were carried out for the prismatic compressive strength, direct terminal strength, and diagonal tensile strength of the dry construction wall. The adequacy of the cross section shape was also reviewed through FEM analysis. The results show that the compressive strength and diagonal tensile strength could exert a certain intensity or higher. Furthermore, the H-type module of a key block acted as a shear key for the entire concrete block, which resulted in excellent shear strength performance. In addition, the shape and thickness of the main block have a major effect on the strength performance of each block. Therefore, an optimal shape and the proposed dry construction method could be applied to replace the wet method by studying the construction or seismic performance of the proposed method.