• Title/Summary/Keyword: The causes of fire

Search Result 510, Processing Time 0.027 seconds

A Study on Intelligent Technique for Correlation Application of Overcurrent and Leakage Current Signals in the Indoor Wiring (옥내배선에서 과전류와 누전 신호의 상관관계 적용을 위한 지능형 기법 연구)

  • Kim, Doo-Hyun;Kim, Eun-Jin;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.4
    • /
    • pp.14-19
    • /
    • 2015
  • The purpose of this paper is to study the correlation application that electrical fire causes occurs for overcurrent and leakage current signals in the indoor wiring. In the order to purpose, the causes data of overcurrent, or leakage current of electrical fire are drawn out referring to past studies, consulting with experts and experimental data. The correlation application was then applied with fuzzy logic of intelligent technique. To check the reliability and performance of the correlation application, modified center of area(CoA) was adopted to calculate the possibility that electrical fire occurs, whose value was then compared to the results. The chance of electrical fire calculated is higher when two causes of fire are put into the CoA of the correlation application of this paper than that of when each cause is separately put into the CoA. The correlation application developed in this study enables better analysis on possible electrical fire due to overcurrent, or leakage current and provides managers with the possibility of electrical fire so that they can better manage at a time of overcurrent, or leakage current.

A Study on Cause Analysis of a Fire that Broke Out on a No-start Motor Vehicle (시동불능 자동차에서 발생한 화재의 원인 분석 연구)

  • Lee, Eui-Pyeong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.6
    • /
    • pp.92-99
    • /
    • 2012
  • It is often thought that because no-start motor vehicles cannot start an engine, a fire cannot occur for motor vehicle causes. However, although the engine cannot start up, some parts may be live with electricity if a battery is connected. If the parts have problems, a fire can occur. This study analyzed the causes of fires occurring when a motor vehicle was loaded onto a tow truck to service no-start. It is suggested that no-start motor vehicles should separate a battery terminal to prevent a fire. And this fire is related to automotive products liability.

Study of oriental medical science documentory records of tinnitus and neuropsychiatric aspect of hiccup (이명(耳鳴)에 관한 정신의학적 문헌고찰(文獻考察))

  • Jang, Young-Ju;Jung, In-Chul;Lee, Sang-Ryong
    • Journal of Haehwa Medicine
    • /
    • v.18 no.1
    • /
    • pp.67-81
    • /
    • 2009
  • 1. According to causes of attack and symptoms, tinnitus is divided into two categories; deficiency and excess. Causes of excess syndrome of tinnitus were wind fire in the liver and gallbladder, phlegm fire, blood stagnation, and heat in meridian system and the causes of deficiency syndrome of tinnitus were qi deficiency or blood deficiency after an illness or delivery, yin deficiency of liver and kidney, and deficiency of sea of the marrow. 2. Tinnitus was related to the vicera and bowels, especially to liver, gallbladder and urinary bladder. 3. In regard of method of treatment, tonify kidney, nourish heart, clear the liver and discharge heat are used according to visera and bowel theory. Clear phlegm and downbear fire are used for phlegm fire. Tonify spleen and kidney is used for ancestral vessel deficiency. Dispel wind and dissipate fire can be used according to theory of five elements' motion and six kinds of natural factors. 4. The basal meridian of acupuncture and moxibustion treatment were the channels of Shaoyang.. 5. Regarding neuropsychiatric aspect of tinnitus, sudden anger and depression of mind were the main mechanism of disease and liver fire was the main cause. The prescriptions for neuropsychiatric tinnitus were Dangguiyonghuehwan, and Yongdamsagantang.

  • PDF

A Study on Problems of High-rise Building Fires in Korea and the Basic Directions for Fire Safety of High-rise Building Design (우리나라 고층건축화재의 문제점과 그 대책의 기본방향에 관한 연구)

  • 이강훈
    • Fire Science and Engineering
    • /
    • v.4 no.2
    • /
    • pp.15-26
    • /
    • 1990
  • Building become higher. larger and more complex than ever before, showing abrupt changes in building structures. forms and mechanical systems. Likewise hazads of fire and the scale of fire losses become more and more greater. Therefore. considerations for fire safety take up great portion of the building design process. In this study, problems of high-rise building fires and basic directions for fire safety of high-rise building design were studied through the statistical analysis of 138 fire cases. The results of this study are summarized as follows : ·Most of the fires in high-rise building occur on the low floors and the fire frequencies are very low on the upper floors. Fire casualties are liable to be more on the upper floors than on tile floor of fire origin. ·The important causes of evacuation failures were analyzed as being late in escape and lack of stairwell enclosures. ·The main cause of vertical fire spread is lack of stairwell enclosures. However, the fire spreads mainly through the enterior windows in apartment houses. The combustible materials in buildings act on as the major factors of horizontal fire spread and the improper fire doors play role of another the critical causes. ·The basic directions for fire safety of high-rise building design put much stress firstly on the compartmentation of the buildings effectively performing the provision of safe escape routes and the safe refuse places in buildings.

  • PDF

Trend of Fire Outbreaks in Ghana and Ways to Prevent These Incidents

  • Addai, Emmanuel K.;Tulashie, Samuel K.;Annan, Joe-Steve;Yeboah, Isaac
    • Safety and Health at Work
    • /
    • v.7 no.4
    • /
    • pp.284-292
    • /
    • 2016
  • Background: In Ghana, fire incidents have become a regular occurrence, with thousands of lives and millions of dollars lost every year. Hardly a day passes without news of a fire outbreak in some part of Ghana, causing fear and panic among the people. This generates much discussion centering on rumors relating to politics, sabotage, misfortune, religious differences, etc. This article seeks to discuss the trend of fire incidents occurring in Ghana from 2000 to 2013 and the different ways to prevent these incidents. Methods: The pattern of fire incidence in Ghana as a whole as well as in each region is discussed. The study took into consideration the causes, mechanisms, as well as preventive measures against the fire menace. Data were obtained from the head office of Ghana's national fire service. Results: It was noticed that in general the rate of fire incidence increased each year. This increase was attributed to several factors: rate of population growth and industrialization, unstable electricity, urbanization, negligence, illegal electrical connection, etc. The cause of fire was categorized into domestic, industrial, vehicular, institutional, electrical, commercial, bush, and others. Among these causes, domestic fire accounted for 41% of the total number of fire incidents in the country. Conclusion: Finally, this study presents several recommendations to help prevent and mitigate fire incidents in Ghana.

A Study on causes and remedies of hearing disturbance in chinese medical journals (難聽의 原因, 症狀, 治法에 對한 硏究;中醫雜誌를 中心으로)

  • Kim, Seong-Bae;Kim, Jong-Han;Lim, Gyu-Sang
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.7 no.1
    • /
    • pp.35-51
    • /
    • 1994
  • This is the study on causes and remedies of hearing disturbance in chinese medical journals(1991-1993). The results were as follows. 1. The causes of sudden deafness(突發性耳聾) were usually fire in the liver(肝火).phlegmatic fire(痰火), deficiency of the vital function and essence of the kidney(腎虛), blood stasis or sludge due to stagnation of vital energy stagnation(氣滯血瘀). Remove endogenous heat or fire method(淸瀉火熱法). circulation of phlegm and dampness(運化痰濕). using tonics to cure disease due to deficiency of vital essence of both the liver and the kidney(滋補肝腎) were used for each treatment. 2.The causes of menieres disease were usually mental disturbance due to phlegmatit fire(痰化上搖). dampness-phlegm long standing(痰濕內停), water-dampness retention(水濕停滯), Method of remove heat and circulation phlegm(淸熱化痰法), method of remove water and dampness(利水渗濕法), invigorate function of the spleen and circulation of dampness method(健脾化濕法) were used for each treatment. 3. The causes of toxico-deafness(中毒性 耳聾) were usually heart, liver and kidney functional weakness(心肝腎虛), vital essence and blood weakness(氣血虛弱). Remove obstruction in the flow and circulation phlegm(通窮化痰), reinforce vital energy and tonify blood (補氣活血), using tonics to cure disease due to deficiency of vital essence of both the liver and the kidney(滋補肝腎) were used for each treatment. 4. The causes of deafness (耳聾), tinitus(耳鳴) were usually mental disturbance due to wind and heat(風熱上搖). flaming up of excessive heat of the liver(肝火上亢). exhaustion seat of reproductive essence in kidney(腎精虧虛). Remove endogenous heat and disperse wind(淸熱疏風). remove the fire of liver(淸肝瀉火), through nourish kidney check exuberance of yang(滋腎潛陽), nourish kidney yang(補腎陽). replenish vital energy and improve essential substance(益精血), blood activate for treatment of blood stasis(活血化瘀) were used for each treatment. 5. The effects of mainly used drugs were classified into method of water and dampness remove medicine(利水渗濕藥), nourishing liver and kidney medicine(補肝腎藥), improve blood and vital energy activate medicine(活血行氣藥), through nourish yan medicine check exuberance of yang(滋陰潛陽藥).

  • PDF

A Study on Fire and Explosion Accident Cause in Regenerated Thermal Oxidizer (축열식 소각로의 화재.폭발 사고원인 규명 연구)

  • Lee, Keun-Won;Ma, Byung-Chol;Hwang, Soon-Yong
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.4
    • /
    • pp.7-11
    • /
    • 2007
  • There has been a report of fire and explosion accident in regenerated thermal oxidizer (RTO). This paper was to investigate accident causes of RTO in the resin re-treatment process. The experiments carried out physicochemical properties and thermal stability analyses by using flash point tester, flammable range apparatus, autoignition tester, GC/MSD and thermal screening unit. We inferred causes of fire and explosion from the regenerated thermal oxidizer to prevent an accident of its process.

  • PDF

Causes of local collapse of a precast industrial roof after a fire

  • Bruno Dal Lago;Paride Tucci
    • Computers and Concrete
    • /
    • v.31 no.5
    • /
    • pp.371-384
    • /
    • 2023
  • Precast roofing systems employing prestressed elements often serve as smart structural solutions for the construction of industrial buildings. The precast concrete elements usually employed are highly engineered, and often consist in thin-walled members, characterised by a complex behaviour in fire. The present study was carried out after a fire event damaged a precast industrial building made with prestressed beam and roof elements, and non-prestressed curved barrel vault elements interposed in between the spaced roof elements. As a consequence of the exposure to the fire, the main elements were found standing, although some locally damaged and distorted, and the local collapse of few curved barrel vault elements was observed in one edge row only. In order to understand and interpret the observed structural performance of the roof system under fire, a full fire safety engineering process was carried out according to the following steps: (a) realistic temperature-time curves acting on the structural elements were simulated through computational fluid dynamics, (b) temperature distribution within the concrete elements was obtained with non-linear thermal analysis in variable regime, (c) strength and deformation of the concrete elements were checked with non-linear thermal-mechanical analysis. The analysis of the results allowed to identify the causes of the local collapses occurred, attributable to the distortion caused by temperature to the elements causing loss of support in early fire stage rather than to the material strength reduction due to the progressive exposure of the elements to fire. Finally, practical hints are provided to avoid such a phenomenon to occur when designing similar structures.

Characteristics of the Car Fires Related to a Diesel Particulate Filters and an Analysis of the Process of Proving Fire Causes (미세먼지 저감 장치와 관련된 자동차화재의 특징 및 화재원인 입증절차의 분석)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.32 no.1
    • /
    • pp.99-107
    • /
    • 2018
  • Diesel cars employ a diesel particulate filter (DPF) to reduce the discharge of fine dust. However, cases of fires caused by DPFs have been reported in diesel cars. In this study, I examined the regulation of exhaust gas and exhaust gas recirculation in diesel cars. Then, I analyzed cases of car fires caused by DPFs, their characteristics, car fire factors related to DPFs and preventive measures, and their consideration in investigations of the causes of fires. Finally, regarding car fire investigations, this study proposed a process of proving that fires are caused by DPFs.

Classification of Fire Causes in Warehouses Using the TRIZ Technique and Analysis of Preventive Measures Accordingto 4M (TRIZ기법에 의한 물류창고의 화재원인 및 4M에 따른 예방대책 분석)

  • Han, Sang-Hun;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.3
    • /
    • pp.401-412
    • /
    • 2020
  • This study analyzed the causes of warehouse fires using a creative problem-solving technique called TRIZ. It identified preventive measures by applying 4M. The results are as follows. First, this study examined the inconsistency among the causes of warehouse fires using TRIZ. Second, it analyzed human factors and fire prevention measures in warehouses such as safety standards for managers, and methods for the promotion of safety consciousness among workers, and for the reinforcement of construction technology for sandwich panel workers. Third, it identified the mechanical and facility factors and fire prevention measures in warehouses such as safety facilities, the expanded installation of safety devices, the adoption and development of fire suppression equipment, and the deployment of methods to improve the fire resistance of sandwich panels. Fourth, it presented working and environmental factors and fire prevention measures in warehouses such as the tightening of safety precautions and the supervision of working methods, and setting fire partitions both in loading places and based on performance-based design. Finally, it proposed managerial factors and fire prevention measures in warehouses such as specific targeting for firefighting with low fire hazards, reviewing the material quality regulations of non-combustible or higher for sandwich panels in the specific target of firefighting that cannot apply fire safety standards, installing sprinklers in cold storage, and mandating the installation of automated facilities with retroactive application regardless of the floor area in the warehouse with a sandwich panel structure.