• Title/Summary/Keyword: The causes of fire

Search Result 508, Processing Time 0.044 seconds

Cause-specific Spatial Point Pattern Analysis of Forest Fire in Korea (우리나라 산불 발생의 원인별 공간적 특성 분석)

  • Kwak, Han-Bin;Lee, Woo-Kyun;Lee, Si-Young;Won, Myung-Soo;Koo, Kyo-Sang;Lee, Byung-Doo;Lee, Myung-Bo
    • Journal of Korean Society of Forest Science
    • /
    • v.99 no.3
    • /
    • pp.259-266
    • /
    • 2010
  • Forest fire occurrence in Korea is highly related to human activities and its spatial distribution shows a strong spatial dependency with cluster pattern. In this study, we analyzed spatial distribution pattern of forest fire with point pattern analysis considering spatial dependency. Distributional pattern was derived from Ripley's K-function according to causes and distances. Spatially clustered intensity was found out using Kernel intensity estimation. As a result, forest fires in Korea show clustered pattern, although the degrees of clustering for each cause are different. Furthermore, spatial clustering pattern can be classified into two groups in terms of degrees of clustering and distance. The first group shows the national-wide cluster pattern related to the human activity near forests, such as human-induced accidental fire in mountain and field incineration. Another group shows localized cluster pattern which is clustered within a short distance. It is associated with the smoker fire, arson, accidental by children. The range of localized clustering was 30 km. Beyond of this range, the patterns of forest fire became random distribution gradually. Kernel intensity analysis showed that the latter group, which have localized cluster pattern, was occurred in near Seoul with high densed population.

Numerical Study On Combined Natural Convection-Radiation In Partially Open Square Compartments with A Heater (발열체가 있는 열린 공간내에서의 자연대류-복사열전달 현상에 관한 수치적 연구)

  • 손봉세;한규익;서석호;이재효;김태국
    • Fire Science and Engineering
    • /
    • v.9 no.1
    • /
    • pp.10-19
    • /
    • 1995
  • Study on combined natural convection-radiation In partially open square enclosures filled with absorbing-anisotropic scattering media is performed. A heater block located in the enclosure causes the natural circulation of the fluid in the enclosure which results In significant in-flow of the cold fluid through the partially open wall. Four different locations of the heater are considered to observe the effect of the heater locations on the resulting heat transfer. Results obtained from the combined convection-radiation analyses show much stronger circulation of t he fluid inside the enclosure as compared to those obtained from the pure convection analyses. As the ratio of the open area is Increased, the inflow of the cold fluid and the circulation of the fluid inside the enclosure is increased causing lower fluid temperature Inside the enclosure. It is shown that the location of the heater influences the circulation and heat transfer significantly by showing stronger circulations and more uniform temperature distributions for the cases where the heater is located on the bottom wall as compared to those for the cases where the heater is located on the upper part wall of the enclosure. For pure absorbing medium, the expected circulation in the fluid is relatively week as compared to those with absorbing-scattering medium due to the smaller wall heating as the radiant heat is used to heat the fluid instead. The forward anisotropic scattering phase function is shown to increase the fluid circulation further as compared to the isotropic scattering medium.

  • PDF

Molecular Basis of the Hrp Pathogenicity of the Fire Blight Pathogen Erwinia amylovora : a Type III Protein Secretion System Encoded in a Pathogenicity Island

  • Kim, Jihyun F.;Beer, Steven V.
    • The Plant Pathology Journal
    • /
    • v.17 no.2
    • /
    • pp.77-82
    • /
    • 2001
  • Erwinia amylovora causes a devastating disease called fire blight in rosaceous trees and shrubs such as apple, pear, and raspberry. To successfully infect its hosts, the pathogen requires a set of clustered genes termed hrp. Studies on the hrp system of E. amylovora indicated that it consists of three functional classes of genes. Regulation genes including hrpS, hrpS, hrpXY, and hrpL produce proteins that control the expression of other genes in the cluster. Secretion genes, many of which named hrc, encode proteins that may form a transmembrane complex, which is devoted to type III protein secretion. Finally, several genes encode the proteins that are delivered by the protein secretion apparatus. They include harpins, DspE, and other potential effector proteins that may contribute to proliferation of E. amylovora inside the hosts. Harpins are glycine-rich heat-stable elicitors of the hypersensitive response, and induce systemic acquired resistance. The pathogenicity protein DseE is homologous and functionally similar to an avirulence protein of Pseudomonas syringae. The region encompassing the hrpldsp gene cluster of E. amylovora shows features characteristic of a genomic island : a cryptic recombinase/integrase gene and a tRNA gene are present at one end and genes corresponding to those of the Escherichia coli K-12 chromosome are found beyond the region. This island, designated the Hrp pathogenicity island, is more than 60 kilobases in size and carries as many as 60 genes.

  • PDF

Risk of Electric Arcs by Conductive Dust Accumulated on Circuit Breaker (차단기에 누적된 도전성 분진에 의한 아크 위험성)

  • Kim, Doo Hyun;Kang, Yang Hyun;Kim, Eun Jin;Hwang, Dong Gyu
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.4
    • /
    • pp.20-25
    • /
    • 2015
  • In general, the causes of the electrical fire are overcurrent, short circuit, poor contact, etc. This study is aimed to recognize the risk of electric arc to prevent electrical fires due to the conductive dust accumulated on the circuit breaker. The experiment was carried out by the method that conductive metal dust collected from the field is being accumulated on the experimental electrodes with gap of 13 mm until the arc is generated. In case that arc was generated, the amount of conductive dust was measured and the thickness was calculated. This experiments was conducted by particle size. In order to distinguish particle size, mesh size(60~100, 100~150, 150~200, 200~250mesh) was classified using a sieve. As the results of experiment for each of the particle sizes, it was confirmed that there is differences in the generation of arc depending on the thickness of dust accumulated.

Analysis on the Falling Risk of Building Electric Shutter and Reduction Measures (건축물 전동셔터 추락 리스크 분석 및 저감 방안)

  • Jung, Young-Min;Bang, Hong-Soon;Kim, Ok-Kyue
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.295-296
    • /
    • 2021
  • With the recent diversification and complication of buildings, the functions of building are also developing. As much as the development of buildings, the machine or equipment used for them is also developing. Thus, all sorts of domestic/foreign industrial facilities and fire stations in the whole nation are using the electric shutter that could meet the insulation just like the exterior wall of general buildings, for bringing-in/storage and crime prevention/fire prevention. Currently, various types of electric shutters are used. Such wrong operation and poor management are causing many panel-falling accidents. This study researched the reduction of electric shutter panel-falling risk by reviewing the domestic/foreign laws and standards, and researching the new safety equipment. First, the causes for falling and accident types were drawn by analyzing the cases of electric shutter accidents. After that, a checklist as the measures for reducing the falling of electric shutter in building was suggested by analyzing the items for the inspection of electric shutter.

  • PDF

Analysis of Thermal Characteristics of the Electrical Socket-Outlets by Overcurrent (과전류에 의한 전기콘센트의 열적특성 분석)

  • Kim, Doo Hyun;Kim, Sung Chul;Kim, Kyung Chun
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.3
    • /
    • pp.8-14
    • /
    • 2019
  • Many electrical socket-outlet fire accidents take place not only in homes but in the offices each year. The causes are mostly faulty constructions, managerial problems and carelessness. Construction and managerial flaws can be resolved by regular or special inspections, but carelessness is not solvable through inspections. Such carelessness can be related to the consumption capacity of electrical socket-outlets presently, the rated current of electrical socket-outlets is based on 16A. However, even at 16A, the heat generated in the insulator of an electrical socket-outlet varies due to such factors as part damage and environmental conditions of use. To explore this situation, the study conducted an experiment to analyze thermal relationship by applying 10A, 20A, and 30A currents. To secure reliability, the study employed thermal analysis simulation and compared the thermal relationship in the same current value. The experimental and simulation values were found to be similar and therefore, diverse current values were replaced with the simulation. At 30A, the temperature was found to rise to at least $169.9^{\circ}C$ which had worked as a sufficient amount of energy to bring the insulation aging of insulator.

An Analysis of Patients distribution Rescued or Tansported by Fire Service Department Helicopter at the KangWonDo Region, KOREA (강원도 지역에서의 소방헬기에 의한 이송환자 분석)

  • Lee, Kyoung-Hee
    • The Korean Journal of Emergency Medical Services
    • /
    • v.6 no.1
    • /
    • pp.55-64
    • /
    • 2002
  • This analysis is accomplished by using 331 rescue and medical evacuation cases performed by KangWonDo Fire Service Department Aviation(KFSA-119 Heicopters) between Jan. 1998 and Oct. 2002. By analysing injury causes, annual differences, sexual, scenic(locaional) distribution and wounded part distribution, this study tried to figure out the general tendency of the helicopter-transported patients in Korea. The results are as follows; 1. The whole population of the patients rescued and transported by helicopters is increasing by the annual rate of 150%~200%. 2. For the locational (scenic) distribution of the patients, 57% (190 cases) of the target population were injured on their mountain-climbing or tracking. 3. 12% (41 cases) of the target population were the Inter-Hospital transport cases. 4. 6% (16 cases) were the expired cases. 5. for the wounded part distribution, 46% (106 cases) were muscular skeletal injuries. 6. The aircraft and personnel of the KFSA were rescue-oriented, so for the EMS operations especially inter-hospital transport missions, different medical equipments and personnels are needed.

  • PDF

AUTOMATION OF QUANTITATIVE SAFETY EVALUATION IN CHEMICAL PROCESSES

  • Lee, Byung-Woo;Kang, Byoung-Gwan;Suh, Jung-Chul;Yoon, En-Sup
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.252-259
    • /
    • 1997
  • A method to automate hazard analysis of chemical plants is proposed in this paper. The proposed system is composed of three knowledge bases - unit knowledge base, organizational knowledge base and material knowledge base, and three hazard analysis algorithms - deviation, malfunction and accident analysis algorithm. Hazard analysis inference procedure is developed based on the actual hazard analysis procedures and accident development sequence. The proposed algorithm can perform hazard analysis in two methods and represent all conceivable types of accidents using accident analysis algorithm. In addition, it provides intermediate steps in the accident propagation, and enables the analysis result to give a useful information to hazard assessment. The proposed method is successfully demonstrated by being applied to diammonium phosphate manufacturing process. A system to automate hazard analysis is developed by using the suggested method. The developed system is expected to be useful in finding the propagation path of a fault or the cause of a malfunction as it is capable to approach causes of faults and malfunctions simultaneously.

  • PDF

A Study on Electric Field Dependence of Tree Shape in Low Density Polyethylene (저밀도폴리에틸렌에서 트리 형상의 전계의존성에 관한 연구)

  • 김재환;박창옥;윤헌주
    • Fire Science and Engineering
    • /
    • v.14 no.1
    • /
    • pp.1-7
    • /
    • 2000
  • Internal insulators give rise to partial discharge(PD), which cause local breakdown and even entire insulation breakdown. Treeing due to PD is one of the main causes of breakdown of the insulating materials and reduction of the insulation life. Therefore the necessity for establishing a method to diagnose the aging of insulation materials and to predict the breakdown of insulation has become important. From this viewpoint, we have studied on Electric Field dependence of tree shape in Low Density Polyethylene about treeing phenomena occurring on the high electrical field. As the result, under the reasoning that the growing of tree supposing when the inner part of tree is either dielectrec or conductor has the intermediate characteristics between dielectrec and conductor, theoretically investicated results well according with the experimental results.

  • PDF

Study of the Improvement of Hazardous Chemical Management for Chemical Accident Prevention (화학사고 예방을 위한 유해화학물질 관리 개선 연구)

  • Lee, Deok-Jae;Lee, Tae-Hyung;Shin, Chang-Hyun
    • Fire Science and Engineering
    • /
    • v.31 no.1
    • /
    • pp.74-80
    • /
    • 2017
  • Chemicals are convenient for humans but the damage caused by hazardous chemicals can be widespread if they are not managed properly. The Chemical Substance Management Act strengthened the management of hazardous chemicals and the management of handling facilities. On the other hand, an analysis of chemical accidents occurring in the past 4 years showed that chemical accidents occurring at the handling facilities are increasing, and additional preventive measures are needed. In this study, to prevent chemical accidents of hazardous chemicals, the causes and problems of accidents were analyzed through the case study of chemical accidents and measures for improvement are proposed.