• Title/Summary/Keyword: The Plot of Image

Search Result 89, Processing Time 0.031 seconds

A Study on the 2D Map Production Using the Single Image Rectification (단-사진 기하보정 시스템 구축에 의한 2차원 도면작성)

  • 배상호;주영은
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.19 no.1
    • /
    • pp.77-83
    • /
    • 2001
  • To product the map by terrestrial photogrammetry method, a few rather nuisance stereo image acquiring processing and plot using expensive analytical instruments have to be performed. In this study, plot was made by acquiring and rectification image using simple method rather than above it. For this, geometry rectification system was constructed for the generation of single ortho-image analysis. and these ortho-images of architecture were made and analysed by appling various warping methods. As a result, the performance of single image analysis could be estimated, and it is expected that the application of this is possible to various non-topographic photogrammetry.

  • PDF

A Study of Image Characteristics due to Focus-Grid and Head Phantom Decentering from the Armorphos Silicon Thin Film Transistor Detector the Fixed Focus-Grid is Applied (고정식 초점형 격자가 적용된 비정절 실리콘 평판형 검출기에서 초점-격자와 두부 팬텀의 중심 변위에 의한 화질 특성에 관한 연구)

  • Choi, Jun-Gu;Kim, Byeong-Gi;Cha, Seon-Hwa;Kim, Gyeong-Su
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.1
    • /
    • pp.7-15
    • /
    • 2007
  • This study aim to investigate image characteristics due to focus-grid and head phantom decentering from the armorphos silicon thin film transistor detector the fixed focus-grid is applied, wish to propose right use method of digital medical equipment. Acquired image according to focus-grid and head phantom position decentering using head phantom on armorphos silicon thin film transistor detector the fixed focus-grid is applied. acquired image evaluate pixel value, histogram, plot profile, surface plot using NIB (Image J) image analysis program and compared decentering image with standard image. Mean value and standard deviation value of focus-grid lateral decentering and duplex decentering of focus-grid and head phantom decreased by ratio, consequently increase of horizontality, diagonal decentering. also, deteriorated contrast of image because frequency of high pixel value decreases fairly. according increases decentering, image distortion phenomenon was increase, by next time, pixel mean value of head phantom decentering was no big change but horizontality, diagonal, mean value and standard deviation value of pixel decreased by ratio. Even if increase pixel noise of image because wide latitude and post processing ability of digital detector, radiotechnologist can not recognize. Therefore, radiotechnologist must recognize correctly the photographing factors which increases pixel noise on the grid system installation digital detector and should exam.

  • PDF

Three Dimensional Dynamic Added Variable Plots

  • Seo, Han-Son
    • Communications for Statistical Applications and Methods
    • /
    • v.11 no.2
    • /
    • pp.345-353
    • /
    • 2004
  • Graphical methods for the specification of the curvature as a function of two predictors are animated to see the effect of an added variable to the model. Through a 3D animated plot it might be difficult to find a sequence of interpretable plots. But examples demonstrate that useful information can be obtained by using rotation technique in 3D plot. Besides 3D plots, an example of 2D animated plot applied to the case of high correlation between predictors and an added predictor is also given. It implies that speed of the convergence to a certain image in a dynamic plot may be understood as an influence of collinearity.

DEM Accuracy Assessment from Matching of Color Aerial Image (천연색 항공영상의 매칭 DEM 정확도 평가)

  • Kim, Kam-Lae;Hwang, Won-Soon;Park, Yong
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2003.10a
    • /
    • pp.141-146
    • /
    • 2003
  • In case of producing image map by using the color aerial photograph, DEM makes on huge effects to the accuracy of ortho image. Thus, this paper has the purpose that evaluate the accuracy of DEM acquired by matching the color aerial photograph. At the study, result of color aerial photograph's control point surveying was X=${\pm}$0.14m, f=${\pm}$0.16m. Estimated result by DEM of plot-map and matching has RMSE=${\pm}$1.058m for the elevation(Z). For matching DEM has a minor(-)'s value, it can access that produce by high point than plot-map DEM.

  • PDF

Evaluation of Bone Change by Digital Subtraction Radiography after Implantation of Tooth Ash-plaster Mixture (치아회분과 석고혼합제제 매식후 Digital Subtraction Radiography에 의한 골량 변화의 평가)

  • Kim Jae-Duk;Kim Kwang-Won;Cho Yaung-Gon;Kim Dong-Kie;Choi Eui-Hwan
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.2
    • /
    • pp.423-433
    • /
    • 1999
  • Purpose : To assess the methods for the clinical evaluation of the longitudinal bone changes after implantation of tooth ash-plaster mixture into the defect area of human jaws. Materials and methods : Tooth ash-plaster mixtures were implanted into the defects of 8 human jaws. 48 intraoral radiograms taken with copper step wedge as reference at soon, 1st, 2nd, 4th, and 6th week after implantation of mixture were used. X-ray taking was standardized by using Rinn XCP device customized directly to the individual dentition with resin bite block. The images inputted by Quick scanner were digitized and analyzed by NIH image program. Cu­equivalent values were measured at the implanted sites from the periodic digital images. Analysis was performed by the bidirectional subtraction with color enhancement and the surface plot of resliced contiguous image. The obtained results by the two methods were compared with Cu­equivalent value changes. Results : The average determination coefficient of Cu-equivalent equations was 0.9988 and the coefficient of variation of measured Cu values ranged from 0.08~0.10. The coefficient of variation of Cu-equivalent values measured at the areas of the mixture and the bone by the conversion equation ranged from 0.06 ~0.09. The analyzed results by the bidirectional subtraction with color enhancement were coincident with the changes of Cu-equivalent values. The surface plot of the resliced contiguous image showed the three dimensional view of the longitudinal bone changes on one image and also coincident with Cu-equivalent value changes after implantation. Conclusion : The bidirectional subtraction with color enhancement and the surface plot of the resliced contiguous image was very effective and reasonable to analyze clinically and qualitatively the longitudinal bone change. These methods are expected to be applicable to the non-destructive test in other fields.

  • PDF

DNA Sequence Visualization with k-convex Hull (k-convex hull을 이용한 DNA 염기 배열의 가시화)

  • Kim, Min Ah;Lee, Eun Jeong;Cho, Hwan Gyu
    • Journal of the Korea Computer Graphics Society
    • /
    • v.2 no.2
    • /
    • pp.61-68
    • /
    • 1996
  • In this paper we propose a new visualization technique to characterize qualitative information of a large DNA sequence. While a long DNA sequence has huge information, it is not easy to obtain genetic information from the DNA sequence. We transform DNA sequences into a polygon to compute their homology in image domain rather than text domain. Our program visualizes DNA sequences with colored random walk plots and simplify them k-convex hulls. A random walk plot represents DNA sequence as a curve in a plane. A k-convex hull simplifies a random work plot by removing some parts of its insignificant information. This technique gives a biologist an insight to detect and classify DNA sequences with easy. Experiments with real genome data proves our approach gives a good visual forms for long DNA sequences for homology analysis.

  • PDF

An Assessment of Image Analysis of Longitudinal Bone Changes (시간경과에 따른 골변화의 영상 분석에 관한 연구)

  • Kim Young-Jin;Kim Jae-Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.27 no.1
    • /
    • pp.73-86
    • /
    • 1997
  • This study was performed to assess the analyzing methods developed to detect clinically and quantitatively longitudinal bone changes. Through preliminary experiment, accuracy of Cu-Eq value conversion to the mass of HA was examined. For main experiment, 15 intraoral radiograms taken at soon, 1st, 2nd, 4th, and 6th week after implantation of mixture in extracted sites of 3 cases were used. We took the radiograms with copper step wedge as test object and HA phantom X -ray taking was standardized by using Rinn XCP device customized directly to the individual dentition with resin bite block. The images inputted by Quick scanner into computer were digitized and analyzed by NIH image program. The stability of the copper equivalent transformation and the usefulness of two analyzing methods by ROI and Reslice were examined. Obtained results as follows: 1) On the Cu equivalent images, the coefficient of variation in the measurement of Cu-Eq. value of ROI ranged from 0.05 to 0.24 and showed high reproducibility. 2) All results obtained by resliced contiguous image were coincident with those obtained from the assessment by ROI and formation of plot profile. 3) On the stacked and resliced image at the line of interest, we could analyze directly and quantitatively the longitudinal changes at several portions by plot profile and qualitatively by surface plot. 4) Implant area showed marked resorption till 2 weeks after implantation and showed significant increase in Cu-Eq. value at 6th week(p<0.01) and periapical area showed increase in Cu-Eq. value at 6th week compared to after-operation's.

  • PDF

The Character Design at the Age of Simulation

  • Gong, Nian;Lee, donghun
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2015.05a
    • /
    • pp.425-426
    • /
    • 2015
  • With the progress of science and technology, animation is no longer about simply describing the nature. People's imagination is elevated to new stage, which not only improve the image in the reality, but also create the absent image in the reality. To analyze according to the existence, these characters have two basic elements. The one is the character existing in the reality, we process and design it according to the artistic technique, so as to make it service for the plot and film (hereafter called documentary character). The other is the character not existing in the reality (hereafter called conceptual character), which is called simulation image by Baudrillard.

  • PDF

Development and Evaluation of an Self-Operated Face Capturing System (자가 안면영상 촬영장치 개발 및 검증)

  • Jeon, Young-Ju;Do, Jun-Hyeong;Kim, Jang-Wong;Kim, Sang-Gil;Lee, Hae-Jung;Lee, Yu-Jung;Kim, Keun-Ho;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.17 no.2
    • /
    • pp.115-120
    • /
    • 2011
  • Objectives : The purpose of this study is to develop an apparatus which can take a facial image by self-operated capturing technique. The user can obtain one's facial image immediately after adjusting facial tilt and focusing distance. The system has been designed for classifying Sasang typology based on facial image. Methods : The system is composed of a Webcam, one-way glass mirror and mini LCD. The Webcam takes a facial image which is displayed on the mini LCD. Then the user can see and adjust to the right position in the real time through the image mirror-reflected from the mini LCD. The optical sensor is used to estimate the proper focusing distance. To verify the performance of the system, 11 characteristic points on the facial image are used and compared with high performance DSLR camera(D700) by applying the coefficient of variance and Bland-Altman Plot. Results : The developed system and D700 show enough agreement with the small coefficient of variance to analyse constitutional types with a facial im mage. However, the result of Bland-Altman plot shows that the width parameters have distortions owing to short focusing distance. Conclusions : The system is expected to be utilized on u-healthcare services for home environment after improving the distortion in the width parameters.

DEVELOPMENT OF A POST-PROCESSING PROGRAM FOR VISUALIZATION OF MRI DATA (MRI Data 가시화용 후처리 프로그램 개발)

  • Myong, H.K.;Choi, H.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2007.10a
    • /
    • pp.67-72
    • /
    • 2007
  • A post-processing program based on the OOP(Object-Oriented Programming) concept has been developed for visualization of MRI. User-friendly GUl(Graphic User Interface) has been built on the base of MFC(Microsoft Foundation Class). The program is organized as modules by classes based on VTK-library, and these classes are made to function through inheritance and cooperation which are an important and valuable concept of object-oriented programming. The major functions of this post-processor program are introduced and demonstrated, which include contour plot, surface plots, cut plot and clip plot as well as view manipulation (translation, rotation, scaling etc).

  • PDF