Conformance Testing for IEC 61850 based OCR IED (IEC 61850 기반의 OCR IED에 대한 적합성 시험방안)

  • Yu, Fei;Rim, Seong-Jeong;Choi, Myeon-Song;Lee, Seung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.19-20
    • /
    • 2008
  • IEC 61850 is a new approach international standard which is applicable to Substation Automation System (SAS) and defines the communication between intelligent electric devices (IEDs) in the substation and the related system requirements. It already has a significant impact on the development of different devices or systems used in substation. Conformance claims and the establishment of their validity are important parts of the acceptance of systems and equipment. This paper introduces the conformance testing, mapping of IEC 61850 services and MMS services, and in case study part it gives the example of testing OCR IED.

  • PDF

A Study on Next Generation IT Fields Application of Embedded Systems (임베디드시스템의 차세대 IT 분야 응용에 관한 연구)

  • Park, Chun-Myoung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.840-841
    • /
    • 2012
  • This paper represent a method of next generation IT fields of embedded systems. we discuss the background why the embedded systems is the importance in the next generation IT fields. Also, we describe the hardware oriented embedded systems, the embedded hardware processor, specified processor. And we discuss the embedded system application fields, i.e. mobile phone application, STB application, telematics fields, home automation, personal digital assistant and so on.

  • PDF

Development of Direct Drive Motor for Next Generation Train (차세대전동차용 직접구동전동기 개발)

  • Kim, Gil-Dong;Lee, Han-Min;Lee, Jang-Mu;Oh, Se-Chan;Joung, Eui-Jin
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.688-694
    • /
    • 2009
  • As a drive system for next generation train, we have been making research and development of a direct drive traction motor system without the conventional reduction gear. This traction motor is expected to have many advantages such as low noise, reduced maintenance, and energy saving. Due to the demand for high-output motors in the limited space between the wheels, open-ventilating traction motors with gear box have been widely used for many years. However, a conventional open-ventilating traction motor is necessary periodical disassembly to remove the accumulated dust from open-air ventilation. Reducing this burden, as well as increasing energy efficiency and reducing noise, would benefit the next generation of traction motors. To address these needs, KRRI have been developing a fully enclosed type direct drive motor(DDM) with high-efficiency permanent magnet for the next generation train.

  • PDF

A Study on the Restoration Algorithm For Multi-Outage Areas in distribution system (광역고장을 고려한 정전 복구 알고리즘 연구)

  • Jung Jin Soo;Moon Hyun Kyung;Lim Seong Il;Lee Seung Jae
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.381-383
    • /
    • 2004
  • This paper presents for service restoration Abstract -in electric power distribution systems. The aim of the service restoration is an emergency control in distribution system to restore out-of service areas as soon as possible when a fault occurs in distribution system. For this reason, this paper presents a new service restoration strategy for multi-outage areas. Proposed algorithm consists of two methods. One is individual restoration scheme, the other one is integrated restoration scheme. The former determines restoration order of outage areas based on restoration index. If the former method can not generate a feasible restoration plan, the latter would try to find new configuration without overloaded section through tie exchange method.

  • PDF

Algorithm for Improving the Computing Power of Next Generation Wireless Receivers

  • Rizvi, Syed S.
    • Journal of Computing Science and Engineering
    • /
    • v.6 no.4
    • /
    • pp.310-319
    • /
    • 2012
  • Next generation wireless receivers demand low computational complexity algorithms with high computing power in order to perform fast signal detections and error estimations. Several signal detection and estimation algorithms have been proposed for next generation wireless receivers which are primarily designed to provide reasonable performance in terms of signal to noise ratio (SNR) and bit error rate (BER). However, none of them have been chosen for direct implementation as they offer high computational complexity with relatively lower computing power. This paper presents a low-complexity power-efficient algorithm that improves the computing power and provides relatively faster signal detection for next generation wireless multiuser receivers. Measurement results of the proposed algorithm are provided and the overall system performance is indicated by BER and the computational complexity. Finally, in order to verify the low-complexity of the proposed algorithm we also present a formal mathematical proof.

Optimal Location of a Protective Device by using Parametric Protection Ability Index (파라메터 관점의 보호능력 평가지표를 이용한 보호기기의 위치 선정)

  • Shin, J.H.;Lim, S.I.;Hyun, S.H.;Lee, S.J.;Ha, B.N.;Seol, I.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.366-368
    • /
    • 2003
  • In this paper, a parametric evaluation method of protection ability is proposed. The adequacy of every parameter is evaluated for the setting rules. Then the results are combined to give protection level of a whole protective system. The setting rules are categorized into three groups for hierarchical calculation. The proposed scheme is applied to a location problem of a new protective device to show its effectiveness.

  • PDF

Protective Relaying Algorithm for 3-Phase Power Transformer Protection based on Fuzzy Decision Making

  • Kim, Sang-Tae;Lee, Seung-Jae;Kang, Sang-Hee;Park, Myeon-Song;Yoon, Sang-Hyun;Lee, Tae-Sung
    • KIEE International Transactions on Power Engineering
    • /
    • v.12A no.1
    • /
    • pp.26-30
    • /
    • 2002
  • The four fuzzy criteria to distinguish the internal fault from the inrush fur the power transformer protection have been identified. They are based on the wave shape, terminal voltage, fundamental and second harmonic component of differential current. systematic way to determine the associated fuzzy membership function is also proposed.

SDR Software Download Framework using Jini (Jini를 이용한 SDR 소프트웨어 다운로드 Framework)

  • Jang Kee-Hyun;Kwon Yong-Ho;Kim Mun-Gi;Rhee Byung-Ho
    • Proceedings of the IEEK Conference
    • /
    • 2004.06a
    • /
    • pp.257-260
    • /
    • 2004
  • This paper describes the software download framework for SDR(Software Defined Radio). SDR is expected to solve the compatibility problem among various mobile communication standards so that people can use the same device for different wireless network. We integrated the SDR software download process into Jini architecture, and modified Jini's several functions. We implemented this proposed framework on a Linux and windows operating systems with Java programming language. With Java platform, we can easily transfer this framework into hand-held devices.

  • PDF

Protectability: An Index to Indicate Protection Level of Primary Distribution Systems

  • Lee, Seung-Jae;Park, Myeon-Song;Kang, Sang-Hee;Kim, Sang-Tae
    • KIEE International Transactions on Power Engineering
    • /
    • v.3A no.1
    • /
    • pp.7-16
    • /
    • 2003
  • A new method to evaluate the protection capability of distribution systems is reported in this paper. This work describes the fuzzy evaluation attributes and aggregation method of evaluation results based on a hierarchical model and the modified combination rule. An evaluation grade index called "protectability" is proposed and is expected to be a very uscful tool in defining an optimal protection and realizing the adaptive protection.rotection.

Using Protective Relaying for Power Quality Monitoring (보호계전기를 이용한 전기품질 감시 기법 연구)

  • Bea, Y.J.;Lim, S.I.;Choi, I.S.;Lee, S.J.;Kim, J.H.;Kim, B.J.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.62-64
    • /
    • 2002
  • Power quality monitoring system is devoted to more concern than before, because the innovation of industrial technology needs more accurate instruments and more advanced power quality. Therefore, this paper is proposed to use digital protective relays for power quality monitoring. In addition, taking power quality events, Electrical magnetic phenomenon of IEEE std 1159, proposing that adaptive power quality event list consider limitation memory capacity and signal processing ability of protective relay. The prototype S/W of power quality analysis is also developed. Especially this prototype S/W analysis scheme is verified through many kinds of power quality events (gathering protective relay data) in EMTP simulation.