• Title/Summary/Keyword: The Korean Pharmaceutical Codex

Search Result 18, Processing Time 0.024 seconds

Development of Alternative Assay Method without Hazardous Reagent, Chloroform for Urazamide Tablets in Korean Pharmaceutical Codex (우라자미드 정의 유해시약 대체 시험법의 개발)

  • Lee, Yoo Rim;Kim, Hyun Ji;Seo, Narae;Kim, Kyeong Ho
    • YAKHAK HOEJI
    • /
    • v.58 no.2
    • /
    • pp.125-128
    • /
    • 2014
  • We developed an alternative assay method without hazardous reagent of chloroform for urazamide tablets in Korean Pharmaceutical Codex. The HPLC analytical method was validated by system suitability, linearity, precision, accuracy and robustness. The linearity of the calibration curves in the desired concentration range is good ($r^2$ >0.999). Precision was obtained less than RSD 1.17%. Accuracy was obtained with recoveries in range of 98.12% and 99.47%. The developed assay could be expected to become valuable tools for revising the Korean Pharmaceutical Codex.

Development of alternative titration method without mercuric acetate for the assay of difemerine hydrochloride in Korean Pharmaceutical Codex (디페메린염산염 시험에 사용되는 유해시약인 수은 대체 시험법의 개발)

  • Jeon, Sang-Seol;Kim, Kyeong Ho
    • Analytical Science and Technology
    • /
    • v.27 no.4
    • /
    • pp.196-200
    • /
    • 2014
  • Currently nonaqueous titration method for the assay method using the hazardous reagent, mercury acetate for difemerine hydrochloride has been used in Korean Pharmaceutical Codex. We developed an alternative titration assay method by substituting the use of the hazardous reagent, mercury acetate to the use of less toxic ones like ethyl alcohol. The linearity of the calibration curves in the desired concentration range was good (r>0.999). Precision was less than 0.64%. Accuracy was obtained with recoveries in range of 99.10% and 99.71%. The developed assay could be expected to become valuable tools for revising the Korean Pharmaceutical Codex.

Development of Alternative Testing Methods without Hazardous Reagents used in Korean Pharmaceutical Codex (고시의약품 시험에 사용되는 유해시약 대체 시험법 개발)

  • Kim, Hee-Yun;Kang, Hyun-Kyung;Choi, Seon-Hee;Bang, Su-Jin;Han, Kyung-Jin;Choi, Sung-Hee;Kim, Jin-Hee;Lee, Hwa-Jung;Kang, Chan-Soon
    • YAKHAK HOEJI
    • /
    • v.54 no.2
    • /
    • pp.142-149
    • /
    • 2010
  • Development of alternative testing methods for the replacement of hazardous reagents with less hazardous ones is strongly enforced because exposure of human and environment to hazardous reagents are restricted and hazardous reagents are gradually prohibited from using in various testing methods. Thus, in this study, we developed 8 monographs from the Korean Pharmaceutical Codex by substituting the use of the hazardous reagents including ICH class 1 such as benzene, chloroform and dioxane to the use of less toxic ones like ICH class 2 or 3 reagents. We also improved their qualification and quantification performance. Among 8 monographs, the 6 newly developed TLC methods for the identification of nifedipine, oxolamine citrate, ketoprofen lysinate, chlorquinaldol, retinol acetate, and riboflavin showed a clear spot of corresponding material without any interference in spite of the replacement with ICH class 2 or 3 reagents. For the quantification of domperidone and trimebutine, HPLC methods were developed for the substitution of UV/VIS spectrometry and titrimetry, respectively. These HPLC methods were validated for the linearity, recovery, reproducibility, and inter-laboratory variations. In conclusion, the newly developed methods could be expected to become valuable tools for revising the Korean Pharmaceutical Codex.

Establishment of Quantitative Method for Generic Drugs in Korea Pharmaceutical Codex Monograph (공정서 수재 의약품의 정량법 개선에 관한 연구)

  • Song, JaeYong;Jang, JinSeob;Jang, SeungEun;Kim, SunHoi;Kim, InKyu;Lee, GilBong;Lee, JeaMan;Kim, YongHee
    • YAKHAK HOEJI
    • /
    • v.56 no.5
    • /
    • pp.288-292
    • /
    • 2012
  • The aim of the paper is to ameliorate old research methods of Korean Pharmaceutical Codex to adjust the newest scientistic level which is necessary to maintain quality of medical supplies effectively. After reviewing result of Establishment of Dissolution Specifications for Generic Drugs in Korea Pharmaceutical Codex Monograph, there are two items chosen for the methods - Establishment of Dissolution Specifications for Generic Drugs in Korea Pharmaceutical Codex Monograph which KFDA researched in 2010, arranged new measuring standard by having an experiment to set measuring method after obtaining each item. According to the result, The experiment includes a measuring method of two items; Nafronyl Oxalate Capsules, and Ticlopidine Hydrochloride Tablets. The research is ameliorated by research methods through several experiments such as High Performance Liquid Chromatography validation, preparing items, implement of trial-experiment and authentic experiment, and experiment on measuring method of regulations of Korea Pharmaceutical Codex. The experiments are taken opinions of experts in KFDA into consideration and wrote out a report of the new measuring method on each last item. The report is combined as each two experiment sections of analyzing method to maintain the quality on the basis of the research in 2010 on setting of dissolution specifications for oral solid dosage forms. The result of measuring method of medical supplies through modernizing trial method of oral solid dosage forms is available to be accurate. In conclusion, this study could contribute to promotion of public health by organizing a basis for safe and high quality of medical supplies in domestic market.

Development of the Standard Analytical Methods for Compound Hawthorn Berry 60% Ethanol Extract, Ginkgo Biloba Leaf Extract and Garlic Oil Capsules (복방서양산사60%에탄올엑스.은행엽엑스.마늘유캡슐의 기준 및 시험법과 규격 설정)

  • Cho, Chang-Hee;Kim, Ji-Sun;Whang, Ji-Sang;Baek, Ju-Hyun;Park, Ju-Young;Shim, Young-Hoon;Seong, Rack-Seon;Kim, Dong-Sup;Lee, Jong-Phill;Lee, Joo-Hyeun;Sohn, Su-Jung
    • Korean Journal of Pharmacognosy
    • /
    • v.41 no.1
    • /
    • pp.67-72
    • /
    • 2010
  • In the recent version of the Korea Pharmacopoeia(KP) and the Korean Herbal Pharmacopoeia(KHP), there are 563 items(181 in KP, 381 in KHP) of herbal medicines including finished drugs. Also, approximately 507 items including herbal extracts and herbal medicinal products was published in the 3th edition of Korea Pharmaceutical Codex (KPC). These items help the persons working in the pharmaceutical manufacturing field to register the drug and in research fields to develop the new drug considering as a standard specifications. This study was carried out to establish standard analytical methods for 'Compound Hawthorn Berry 60% Ethanol Extract, Ginkgo Biloba Leaf Extract and Garlic Oil Capsules' in the 3th edition of Korea Pharmaceutical Codex. Ginkgo flavonoid and terpene lactone were employed as reference compounds for analytical method. Analytical methods established in this study could be applied to a reasonable and unified quality control of G. biloba leaf extract and hawthorn berry extract.

Development of alternative assay method without hazardous reagent, carbon tetrachloride, for cefroxadine capsules in Korean Pharmaceutical Codex (세프록사딘 캡슐 시험에 사용되는 유해시약인 사염화탄소 대체 공정시험법 개발)

  • Seo, Narae;Kang, Yeoul;Park, Yeong Shin;Lee, Jong Min;Jeong, Myung Jin;Jeon, Sang Seol;An, Jae Hyung;Kim, Kyeong Ho
    • Analytical Science and Technology
    • /
    • v.27 no.3
    • /
    • pp.161-166
    • /
    • 2014
  • Currently oxidation-reduction titration method for the assay method using the hazardous reagent, carbon tetrachloride, for cefroxadine capsules has been used in Korean Pharmaceutical Codex. We developed and validated an alternative HPLC assay method by substituting the use of the hazardous reagent, carbon tetrachloride, to the use of less toxic ones like acetonitrile. The linearity of the calibration curves in the desired concentration range was good ($r^2$ > 0.999). Relative standard deviations of intra-day precision were ranged between 0.30% and 0.69% and inter-day precision were ranged between 0.47% and 0.82%. Accuracy was obtained with recoveries in range of 100.20% and 100.56%. Developed method was applied to the determination of cefroxadine in commercial cefroxadine capsule and could be expected to become valuable tools for revising the Korean Pharmaceutical Codex.

Revision of The Korean Pharmceutical Codex, The Third Edition (의약품 등 기준 및 시험방법(제 3개정) 소개)

  • Choi, Myoeng-Sin;Yang, Ji-Sun;Yoo, Tae-Moo;Kim, In-Kyu;Kim, Hye-Soo;Lee, Sun-Hee;Chang, Seung-Yeup;Cho, Jung-Hee;Lee, Su-Jung;Kim, Young-Lim;Kim, Mi-Jeong;Kim, Eun-Jung;Lee, Jong-Pil;Kim, Do-Hoon;Baek, Kyung-Min;Kim, Hee-Sung;Park, Sang-Aeh;Kang, In-Ho;Kim, Eun-Kyung
    • Journal of Pharmaceutical Investigation
    • /
    • v.35 no.3
    • /
    • pp.201-205
    • /
    • 2005
  • The aim of publishing the Korean Pharmaceutical Codex is to update and set specification of essential drugs for humane health. In accordance with speedy development of new drugs and improvement of science and technology, the need of revision of drug specification through the ICH guidelines and discussions between regulatory agency and pharmaceutical industry for the quality assurance of safer and efficient drugs is getting higher. The first edition of Korean Pharmaceutical Codex was published in 1983. Now, the third revision of the Codex is prepared because of the revision of domestic and foreign Pharmacopeias, changes of drug control environment, improvement of science and technology and so on. The aim of 3th edition is to improve the quality of essential drugs through the setting of the required specifications and discussions between the regulatory agency and pharmaceutical industry.

Development of Analytical Method for Ambroxol Hydrochloride and Clenbuterol Hydrochloride Formulation in Korean Pharmaceutical Codex (고시수재 의약품 중 암브록솔염산염 및 클렌부테롤염산염 함유 제제의 함량 시험법 개선)

  • Lee, Tae-Woong;Jeong, Rae-Seok;Park, Soo-Jin;Choi, Lan;Shim, Young-Hun;Choi, Bo-Kyung;Kwak, Hyo-Sun
    • YAKHAK HOEJI
    • /
    • v.58 no.3
    • /
    • pp.190-199
    • /
    • 2014
  • The Korean Pharmaceutical Codex (KPC) analytical method of ambroxol hydrochloride and clenbuterol hydrochloride formulation is complicated and needed to carry out multiple processes during the test. To improve the low efficiency of analytical procedure that makes pharmaceutical laboratory consume much time and high cost to conduct the test of this formulation, this study was performed for simplifying the pretreatment process and optimizing conditions of the HPLC assay. The analytical procedure using HPLC was developed to establish analytical specification for ambroxol hydrochloride and clenbuterol hydrochloride formulations. The newly developed analytical method has good linearity ($R^2$ >0.999), specificity, precision (RSD<1.0%) and the recovery ranges of 98.50~101.84% for ambroxol, 98.29~101.35% for clenbuterol syrup and 98.66~101.71% for clenbuterol tablets. The LOQs were 0.204 ${\mu}g/ml$ for ambroxol, 0.021 ${\mu}g/ml$ for clenbuterol syrup and 0.073 ${\mu}g/ml$ for clenbuterol tablets. The new method was performed with commercially available samples to confirm analytical conditions and validated to be suitable for saving time and cost to control the quality of routine manufactured products. This analytical method will be used for revising the monograph of ambroxol hydrochloride and clenbuterol hydrochloride formulation in next supplement of KPC.

Development of Dissolution Test Method for Acebrophylline Capsules and Bromhexine Hydrochloride Tablets in Korean Pharmaceutical Codex (고시수재 의약품 중 아세브로필린 캡슐 및 브롬헥신염산염 정의 용출시험법 개발)

  • Lee, Tae-Woong;Jeong, Rae-Seok;Jeong, Seung-A;Kim, Jeong-Hyun;Shim, Young-Hun;Kim, In-Kyu;Park, Chang-Won
    • YAKHAK HOEJI
    • /
    • v.57 no.3
    • /
    • pp.226-233
    • /
    • 2013
  • Although the dissolution test can serve as an effective tool for quality control and predictor of in vivo performance, there are a number of drugs with no established dissolution specification in Korean Pharmaceutical Codex (KPC). So, with each reference and test drugs, the dissolution test method and an analytical procedure by HPLC were developed and validated to establish dissolution specification for acebrophylline capsules and bromhexine hydrochloride tablets. The dissolution condition was determined based on the "Guidelines on Specifications of Dissolution tests for Oral dosage forms" of Ministry of Food and Drug Safety (MFDS). The analytical method of HPLC was validated in specificity, linearity, precision and accuracy. Final dissolution test was performed with commercially available samples of 3 lots to establish specification. In addition, no difference was observed by the inter-laboratory evaluation. Dissolution specifications and conditions will be used for revising the monograph of acebrophylline capsules and bromhexine hydrochloride tablets in next supplement of KPC.

Development of Dissolution Testing Method for Piracetam Tablets and Fenoterol Hydrobromide Tablets in Korean Pharmaceutical Codex (고시 수재 의약품 중 피라세탐 정 및 브롬화수소산페노테롤 정의 용출시험법 개발)

  • Kim, Eun-Jung;Lee, Jin-Ha;Park, Chan-Ho;Sohn, Kyung-Hee;Kim, In-Kyu;Kim, Dong-Sup;Sah, Hong-Kee;Choi, Hoo-Kyun
    • YAKHAK HOEJI
    • /
    • v.55 no.4
    • /
    • pp.324-331
    • /
    • 2011
  • Although the dissolution test can serve as an effective tool for quality control and predictor of in vivo performance, there are a number of drugs with no established dissolution specifications in Korean Pharmaceutical Codex (KPC). Among those commercially available, Piracetam Tablets and Fenoterol hydrobromide Tablets were selected to develop the dissolution testing method. The dissolution condition was determined based on the "Guidelines on Specifications of Dissolution tests for Oral dosage forms" of Korea Food & Drug Administration (KFDA). The dissolution test for Piracetam Tablets was carried out under sink condition with distilled water as dissolution medium, paddle rotation speed at 50 rpm and medium volume of 900 ml. More than 80% of its label claim was released within 30 min. In case of Fenoterol hydrobromide Tablets, distilled water was also found to be suitable to ensure sink condition. The rotation speed of 50 rpm and 900 ml of dissolution medium were used to evaluate the dissolution profile. The dissolution rate of fenoterol hydrobromide was over 90% in 15 min. The HPLC analysis methods were validated in terms of accuracy, precision, specificity, linearity, quantitation limit and range. The results suggested that the analytical methods used are simple and suitable to measure the dissolution rate of piracetam and fenoterol hydrobromide. Therefore, the analysis methods could be utilized in setting dissolution specifications of Piracetam Tablets and Fenoterol hydrobromide Tablets in the revised version of KPC.