• 제목/요약/키워드: The Electrical Fires

검색결과 184건 처리시간 0.036초

화염에 의한 수직배치전극에서 공기의 절연파괴전압특성 (Breakdown voltage characteristics of air with vertical arranged electrodes due to flame)

  • 김충년;지승욱;이광식;이동인;김인식;김이국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1735-1737
    • /
    • 2001
  • The occurrence of fires under transmission lines is responsible for a great number of power line outages. In this paper, the ac flashover voltages and the corona onset voltages of a needle-plane electrode gap of vertical arrangement in the presence of flame were investigated. We also observed the corona discharge current and variation of shapes in flame with increasing the applied voltages. We found that the corona onset voltages and the flashover voltages were drastically decreased with the position of flames and gap length of electrodes, and observed that the deflection or fluctuation phenomena in the shape of flames.

  • PDF

단일 사각 레일 주행이 가능한 감시 로봇 설계 (Development of an Inspection Robot Operating on a Single Square Rail Track)

  • 류우석;이성온
    • 로봇학회논문지
    • /
    • 제17권2호
    • /
    • pp.216-220
    • /
    • 2022
  • This paper proposes an inspection robot that can operate on a single square rail. Various inspection robots have been developed to identify emergency situations in industrial environments, such as those involving fires or individuals with cardiac arrest. Because the robots must operate in wide areas and long tunnels, they are designed to move along a rail installed on the ceiling. Double rail track are typically used to ensure the stability of robot movement. However, the cost for installing a double rail track is nearly two times that for a single rail track. Moreover, it is challenging to install double rail tracks while ensuring the same curvature and interval between the two rails. Therefore, in this study, an inspection robot that operate on a single square rail track is developed. To ensure stable movement in the longitudinal and lateral directions, two passive guide parts are used, and the main active wheel is allowed to move on the upper side of the square rail. The prototype was manufactured, and experiments were performed for different robot velocities.

산불에 의한 활선선로의 이도변화 거동 (Temperature and Load Change behavior of Overhead Conductor under loading current due to Forest Fire)

  • 김병걸;김상수;장용호;한세원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1295_1296
    • /
    • 2009
  • The authors have published several technical reports on the deterioration of conductor due to forest fire in series so far. This is because even we have been experiencing hundreds of forest fires every year, no systematic research on conductor which is very vulnerable to fire have been fulfilled. This paper describes the sag-tension behavior of conductor under loading current normally when only partial area of a long conductor is exposed to fire. Temperaures of Overhead Conductor were different with measurement position. When the partial area of conductor was heated up to $500^{\circ}C$, 20 % of permanent tension loss was observed. This results in the increase of sag of 1.5 m when span is 300 m. The other results will be presented in the text.

  • PDF

모의 송전선로의 섬락특성에 미치는 화염의 영향 (Influence of flame on flashover characteristics of model transmission line)

  • 김인식;김충년;지승욱;이상우;이광식;이동인;김이국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1738-1740
    • /
    • 2001
  • The occurrence of fires under transmission lines is responsible for a great number of power line outages. In this paper, the ac flashover voltages and the corona onset voltages of a model transmission line in the presence of flame were investigated. We found that the corona onset voltages and the flashover voltages were varied with the position of flames. Flashover voltages of vertical arranged electrodes with flame appeared to decrease 43[%] lower than those of same conditions with no flame.

  • PDF

화염으로 인한 전기적 섬락특성 변화 (A Flashover Characteristics Due to Flames)

  • 손홍관;이형권;한형주;박인표;오한호;민병욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.703-704
    • /
    • 2007
  • Most of the transmission lines in Korea pass through a mountains. The forest fire occurred in around the transmission lines make an accident such as flashover and faults in the power transmission lines. In spite of that risk, there are no research on the flashover characteristics by fires in electric discharge engineering in our country. This paper was mentioned about the relation between the flame and flashover characteristics. We were carried out simple test by using artificial flame generator and rod-plane or conductor-plane gaps. And we were summarized test results.

  • PDF

전기화재 분야에서 다목적으로 시험장치의 활용범위를 증가시키기 위한 시험장치의 설계 및 구현 (Design and Implementation of a Multi-purpose Test Equipment with a Large Utilization Range for use in Electric Fire)

  • 신동철;고형호
    • 센서학회지
    • /
    • 제32권3호
    • /
    • pp.180-186
    • /
    • 2023
  • Test devices can perform various functions, such as research on detection targets, sensors that detect detection targets, combined products containing sensors, and certification for the launch of combined products. However, the scope of use of test devices is limited because they perform only a single role or could only serve a particular purpose in the past. Therefore, studies on test devices that can perform various functions, such as research on detection targets, sensors that detect detection targets, combined products containing sensors, and certification for the release of combined products are necessary. Accordingly, this study proposes a test device that can increase the scope of use in the technical field of electric fires. In addition, we examine various outcomes of the proposed test device.

선풍기의 운전 상황별 발열특성 및 전류신호 검출 (Detection of Current Signal and Thermal Characteristics of Electric Fan Operated in Various Situations)

  • 김두현;이흥수
    • 한국안전학회지
    • /
    • 제29권3호
    • /
    • pp.20-27
    • /
    • 2014
  • Cooling equipment is the frequent occurrence of fire despite the absence of the heating element. National fire statistics in 2013 show that a total of 263 fires occurred in the cooling equipment and the number of electric fan has 145 fire cases. This is accounted for 55.1% of the whole. Electric fan is the electrical appliance that the heat is generated on the winding wire and the iron core. If such characteristic is not controled properly, fire would break out at the electric fan. also there is a gap filled with an insulator between connection terminals of the capacitor in the electric fan. But in case that the gap on the capacitor is covered with some conductive material such as dust, there would be a fire as well caused by electrical heating locally. Although many studies related with those have been conducted, electric fan fire is continuously occurred. In this study, thermal characteristics and current signal in various conditions such as the heat generation of windings including iron cores of the motor and the dielectric breakdown of terminals on the capacitor connected to the motor were detected. In order to measure the maximum temperature, "third level" wind velocity button was pushed and the time selection switch to "continuation" was set. Analyzed data would be available for the fire safety of the electric fan.

500MW급 화력발전소 수소냉각시스템의 안전대책 (A Study on the safety measures for hydrogen cooling system of 500MW class thermal power plant)

  • 김순기;육현대;가출현
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.385-390
    • /
    • 2005
  • This paper provided a counter measures against the troubles and accidents that are likely to take place in the power plant using hydrogen gas as a coolant for the cooling system of the generator. Because of the extremely wide flammability limits of hydrogen in comparison to the other flammable gases, the safety measures against the hydrogen accidents is very important to ensure the normal operation of electric-power facility. This study's purpose was a presentation of standard model of safety management of hydrogen equipments in the coal firing power plant such as following items: 1) providing the technical prevention manual of the hydrogen explosions and hydrogen fires occurring in the cooling system of power generator; 2) the selection of explosion-proof equipments in terms of the risk level of operating environment; 3) the establishment of regulations and counter measures, such as the incorporation of gas leakage alarm device, for preventing the accidents from arising; 4) the establishment of safety management system to ensure the normal operation of the power plant.

  • PDF

열화된 저압용 콘센트에서 방전신호의 발생과 검출 (Generation and Detection of Discharge Signals in Deteriorated)

  • 송재용;서황동;문승보;길경석;조영진
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2005년도 추계종합학술대회
    • /
    • pp.200-203
    • /
    • 2005
  • Most of electrical fires are caused by short circuits, overheating of wires, deterioration and incomplete connection of wiring devices. The last two cases are predictable before the occurrence of fire because of its slow progress. In this paper, we have simulated the discharge signals caused by the deterioration and incomplete connection of wiring devices using an aged concent to provide information on the characteristics of discharge signals. From the experimental data, we could characterize the frequency spectrums of the discharge signals depending on the cases. The higher frequency components of the signal are attenuated by the capacitance and inductance of power lines as the measuring point is getting away from the discharges. Main frequency components of the discharge signal are existent at 600 kHz - 1.5 MHz in incomplete connections and at 210 kHz - 8 Mhz in deteriorations of the concent.

  • PDF

전기화재의 발생원인 및 분석 -누전차단기의 동작특성을 중심으로- (The Causes and Analysis of Electrical Fires -focused on Dynamic Characteristics of RCD-)

  • 이상호
    • 한국화재소방학회논문지
    • /
    • 제17권2호
    • /
    • pp.1-5
    • /
    • 2003
  • 현재 고감도의 누전차단기(RCD)와 배선용차단기(WCCB)및 퓨즈(Fuse)설치를 통하여 누전·단락사고와 과전류 발생시 차단기능을 부여함으로써, 전기화재의 발생을 억제하고 있으나, 매우 미흡한 실정이다. 특히 소손사고와 접속·접촉불량사고 및 순간단락사고 발생시는 구조적으로 차단이 불가능할 것으로 사료되며, 이에 대한 연구가 필요하다. 따라서 본 논문에서는 상기의 상황에 기초해서 가장 일반적으로 사용되고 있는 열동형 누전차단기(단락보호, 과부하 겸용)의 동작원리와 시험항목 및 기준분석을 통하여 문제점을 제시하고자 한다. 또한 저압 배선선로의 소손사고와 접속·접촉불량사고 및 순간단락사고 발생시 전등(R)부하 및 전동기(R-L)부하에 따른 누전차단기의 동작특성을 실제 실험을 통하여 검토하고자 한다.