• Title/Summary/Keyword: The Electric Substations

Search Result 109, Processing Time 0.026 seconds

Measurement and Modeling of Personal Exposure to the Electric and Magnetic Fields in the Vicinity of High Voltage Power Lines

  • Tourab, Wafa;Babouri, Abdesselam
    • Safety and Health at Work
    • /
    • v.7 no.2
    • /
    • pp.102-110
    • /
    • 2016
  • Background: This work presents an experimental and modeling study of the electromagnetic environment in the vicinity of a high voltage substation located in eastern Algeria (Annaba city) specified with a very high population density. The effects of electromagnetic fields emanating from the coupled multi-lines high voltage power systems (MLHV) on the health of the workers and people living in proximity of substations has been analyzed. Methods: Experimental Measurements for the Multi-lines power system proposed have been conducted in the free space under the high voltage lines. Field's intensities were measured using a referenced and calibrated electromagnetic field meter PMM8053B for the levels 0 m, 1 m, 1.5 m and 1.8 m witch present the sensitive's parts as organs and major functions (head, heart, pelvis and feet) of the human body. Results: The measurement results were validated by numerical simulation using the finite element method and these results are compared with the limit values of the international standards. Conclusion: We project to set own national standards for exposure to electromagnetic fields, in order to achieve a regional database that will be at the disposal of partners concerned to ensure safety of people and mainly workers inside high voltage electrical substations.

The study on Reduction of Demand Power in Urban Railway using OLTC (OLTC를 활용한 도시철도 최대전력 감축에 관한 연구)

  • Kim, Han-Soo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.10
    • /
    • pp.963-968
    • /
    • 2016
  • This paper proposes a new method reducing the maximum demand power of substations at urban railway by using transformer with OLTC(:On Load Tap Changer). Most of the domestic urban railway is rectified by a diode scheme, and supplies the electric vehicles in dc 1500[v]. Because the substations are connected in parallel, if an input voltage of a substation is increased, then the voltage of rectifiers is also increased, and which leads to an increase in the maximum demand of the substation. Simulation results show that increment of maximum demand power can significantly be limited using the method proposed in this paper.

Gigabit Ethernet Based Substation

  • Yang, Hyo-Sik;Raza, Ali;Park, Min-Woo;Kim, Sang-Sig;Jang, Hyuk-Soo;Lee, Myung-Ho;Kwon, Dong-Seop;Jang, Byung-Tae
    • Journal of Power Electronics
    • /
    • v.9 no.1
    • /
    • pp.100-108
    • /
    • 2009
  • Designing communication architecture for substation automation is a challenging and subtle task for visualizing substations in the digital world under the umbrella of IEC61850. Communication paradigms for substation automation are of critical importance because of two reasons; the communication arena is changing daily and opts for convenience and simple deployment at a lower migration cost and interoperability is one of the core constrains of IEC61850 for substation automation. This paper presents an analysis and outline of the crucial need for the deployment of Gigabit Ethernet in substations and also presents suggestions on how Ethernet technology can help in substation automation. Ethernet is one of the most pervasive communication technologies available and can provide a long term solution in the changing arena of communication. We have performed simulations in NS-2 to prove that our suggested communication paradigm is optimal in various regards with consideration of the constraints imposed by IEC61850.

A Novel Non-contact Measurement Method for the Detection of Current Flowing Through Concealed Conductors

  • Yang, Fan;Liu, Kai;Zhu, Liwei;Hu, Jiayuan;Wang, Xiaoyu;Shen, Xiaoming;Luo, Hanwu;Ammad, Jadoon
    • Journal of Magnetics
    • /
    • v.22 no.1
    • /
    • pp.43-48
    • /
    • 2017
  • In order to detect the current flowing through concealed conductor, this paper proposes a new method based on derivative method. Firstly, this paper analyzes the main peak characteristic of the derivative function of magnetic field generated by a current-carrying conductor, and a relationship between the current flowing through the conductor and the main peak of the derivative function is obtained and applied to calculate the current. Then, the method is applied to detect the conductor current flowing through grounding grids of substations. Finally, the numerical experimental and field experiment verified the feasibility and accuracy of the method, and the computing results show that the method can effectively measure the conductor current of grounding grids with low error, and the error is within 5 %.

Three-Dimensional Electric Field Calculation around the 345kV Sinmasan Substation Busbars (신마산 345kV 전력소 모선하의 3차원 불평등 전계분포 해석)

  • Myung, Sung-Ho;Lee, Byeong-Yoon;Han, Inn-Su;Park, Jong-Keun;Min, Suk-Won;Kim, Eung-Sik;Lee, Ki-Chul
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1804-1806
    • /
    • 1996
  • For the rather complicated and time-consuming three-dimensional electric field calculation in the vicinity of substations, this paper proposes a numerical calculation method based on charge simulation method(CSM). In order to represent non-uniform charge distribution on an electrode better, it is subdivided into small segments with linear charge density. Non-uniform arrangement of subdivided segments makes it possible to obtain high accuracy with a small number of variables. As for the arrangement of subdivided segments, effective formulars were derived from multiple regression analysis of many simulations. These formulars make the arrangement of segments fast and effective. The proposed method is applied to the electric field calculation around the 345kV Sinmasan Substation busbars and the distribution of calculated electric fields is compared with that of the measured electric fields.

  • PDF

A Novel Fault Location Scheme on Korean Electric Railway System Using the 9-Conductor Representation

  • Lee, Chang-Mu;Lee, Han-Sang;Yoon, Dong-Hee;Lee, Han-Min;Song, Ji-Young;Jang, Gil-Soo;Han, Byung-Moon
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.220-227
    • /
    • 2010
  • This paper presents a novel fault location scheme on Korean AC electric railway systems. On AC railway system, because of long distance, 40[km] or above, between two railway substations, a fault location technique is very important. Since the fault current flows through the catenary system, it must be modeled exactly to analyze the fault current magnitude and fault location. In this paper, suggesting the novel scheme of fault location, a 9-conductor modeling technique including boost wires and impedance bonds is introduced based on the characteristics of Korean AC electric railway. After obtaining a 9-conductor modeling, the railway system is constructed for computer simulation by using PSCAD/EMTDC. By case studies, we can verify superiority of a new fault location scheme and propose a powerful model for fault analysis on electric railway systems.

Loop power flow Analysis of Distribution lines Between Substations (변전소간 배전선로 Loop 조류 검토)

  • Jeon, Sang-Dong;Kim, Gi-Il;Jeong, Kyu-Won;Ryu, Hee-Young;Lee, Bong-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.169-170
    • /
    • 2008
  • 최근 전력수요의 증가 및 부하 고밀도화에 효과적으로 대응하고 배전설비 투자비용의 절감을 통한 경영효율성 증진을 위해 전배전선로를 대상으로 배전선로의 상시운전용량과 비상시운전용량을 상향조정하였다. 도심번화가 공단 등 부하밀집지역, 선로전압 유지곤란지역 및 경과지 확보가 곤란한 지역에 대용량 배전방식을 채택하여 운영하고 있다. 이와 같은 배전계통 운전 용량의 큰 변화에 따라 전력회사에서는 일선사업소의 모든 배전계획자들이 배전계획 및 운영시 배전계통의 설비를 가장 효율적으로 이용할 수 있도록 모든 배전선로에 대하여 배전용변전소, 주변압기, 인접 2회선 등의 상정사고 및 작업시에도 건전정전구간이 발생하지 않도록 부하를 융통할 수 있는 연계 기준이 마련되어 있다. 본 논문에서는 배전선로의 루프운전의 조건가능 여부를 보다 정확하고 신속한 방법으로 사전에 검토하여 고장을 예방하고자 한다.

  • PDF

EMTP simulation of 345kv Substation in large network using newly developed Thevenin equivalent network (345kv 미금 변전소 외부 계통의 등가축약 기법을 이용한 EMTP 모델링에 관한 연구)

  • Jeong, Ki-Seok;Baek, Young-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.244-246
    • /
    • 2008
  • EMTP-RV is the very powerful program to analyze the dynamic operation of the power system. To use this package in the large complex power system, it is very important to simplify the power system to simple equivalent network. In our study the 100 MVA STATCOM is placed at 345kV "MIGUM" which is the one of the 345kV substations of the Korean Electric Power System that is consist of more than 1000 bus. MIGUM substation is connected with 7 separated transmission lines to main Korean Electric power system. We developed a new method to simplify the network except the substation that we want to analysis. The power system outside the 345kV substation is modeled into the equivalent network. The loop network outside the substation can be modeled to simplified Thevenin equivalent network. The proposed method is applied to IEEE-14 Reliability Test System and the results shows the effectiveness of the method.

  • PDF

Modelling Voltage Variation at DC Railway Traction Substation using Recursive Least Square Estimation (순환최소자승법을 이용한 직류도시철도 변전소의 가선전압변동 모델링)

  • Bae, Chang-Han
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.6
    • /
    • pp.534-539
    • /
    • 2015
  • The DC overhead line voltage of an electric railway substation swings depending on the accelerating and regenerative-braking energy of trains, and it deteriorates the energy quality of the electric facility in the DC railway substation and restricts the powering and braking performance of subway trains. Recently, an energy storage system or a regenerative inverter has been introduced into railway traction substations to diminish both the variance of the overhead line voltage and the peak power consumption. In this study, the variance of the overhead line voltage in a DC railway substation is modelled by RC parallel circuits in each feeder, and the RC parameters are estimated using the recursive least mean square (RLMS) scheme. The forgetting factor values for the RLMS are selected using simulated annealing optimization, and the modelling scheme of the overhead line voltage variation is evaluated through raw data measured in a downtown railway substation.

A Special Protection Scheme Against a Local Low-Voltage Problem and Zone 3 Protection in the KEPCO System

  • Yun, Ki-Seob;Lee, Byong-Jun;Song, Hwa-Chang
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.3
    • /
    • pp.294-299
    • /
    • 2007
  • This paper presents a special protection scheme, which was established in the KEPCO (Korea Electric Power Corporation) system, against a critically low voltage profile in a part of the system after a double-circuit tower outage. Without establishing the scheme, the outage triggers the operation of a zone 3 relay and trips the component. This sequence of events possibly leads to a blackout of the local system. The scheme consists of an inter-substation communication network using PITR (Protective Integrated Transmitter and Receiver) for acquisition of the substations' data, and under-voltage load shedding devices. This paper describes the procedure for determining the load shedding in the scheme and the experiences of the implementation.