• Title/Summary/Keyword: The Configuration of the zone

Search Result 142, Processing Time 0.025 seconds

A Study on the Space Zoning and Area Composition of the Operation Department in Regional Public Hospitals - Focused on Net Floor Area (지방의료원 수술부 영역 및 면적 구성에 관한 조사·분석연구 - 순면적을 중심으로)

  • Yun, Woo Yong;Chai, Choul Gyun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.25 no.3
    • /
    • pp.25-36
    • /
    • 2019
  • Purpose: To establish guidelines for local public hospitals, the survey was conducted primarily on the current status of local public hospitals, focusing on the zone configuration and the spatial area of the operating department. Methods: 3 Methods have been used in this paper. 1) Analyzing drawings to derive the net floor area of each room. 2) A literature survey about composition of the zone by infection control. 3) Observation survey for user circulation analysis. Results: The operation department consists of the major, secondary, support and connected zones according to the user's actions. The spatial area composition ratio for each zone is major zone: 41.79%, secondary zone: 10.87%, support zone: 23.10%, and connected zone: 24.24%. Implications: This study is a basic research for guideline for the operation department in local public hospitals. In this study, zones configuration of the operation departments are classified in terms of user actions and room functions. In the future, it is required to establish criteria considering infection control and copper connection aspects.

A CFD Study of Near-field Odor Dispersion around a Cubic Building from Rooftop Emissions

  • Jeong, Sang Jin
    • Asian Journal of Atmospheric Environment
    • /
    • v.11 no.3
    • /
    • pp.153-164
    • /
    • 2017
  • Odor dispersion around a cubic building from rooftop odor emissions was investigated using computational fluid dynamics (CFD). The Shear Stress Transport (here after SST) $k-{\omega}$ model in FLUENT CFD code was used to simulate the flow and odor dispersion around a cubic building. The CFD simulations were performed for three different configurations of cubic buildings comprised of one building, two buildings or three buildings. Five test emission rates were assumed as 1000 OU/s, 2000 OU/s, 3000 OU/s, 4000 OU/s and 5000 OU/s, respectively. Experimental data from wind tunnels obtained by previous studies are used to validate the numerical result of an isolated cubic building. The simulated flow and concentration results of neutral stability condition were compared with the wind tunnel experiments. The profile of streamline velocity and concentration simulation results show a reasonable level of agreement with wind tunnel data. In case of a two-building configuration, the result of emission rate 1000 OU/s illustrates the same plume behavior as a one-building configuration. However, the plume tends to the cover rooftop surface and windward facet of a downstream building as the emission rate increases. In case of a three-building configuration, low emission rates (<4000 OU/s) form a similar plume zone to that of a two-building configuration. However, the addition of a third building, with an emission rate of 5000 OU/s, creates a much greater odorous plume zone on the surface of second building in comparison with a two-building configuration.

Trend Changes of Spatial Configuration in Housing Units of Korean Apartments in the 2000s (2000년대 한국 아파트 단위세대의 공간구성 동향 변화)

  • Park, Joon Young;Jeong, Sang Kyu;Cheong, So Yi;Park, Woo Jang
    • KIEAE Journal
    • /
    • v.12 no.1
    • /
    • pp.21-27
    • /
    • 2012
  • This study aims at finding the trend changes of spatial configuration in housing units of Korean apartments in the 2000s. Among the housing units in the apartments built by large construction companies, we have selected ones with small and regular sizes, $59m^2$ and $84m^2$ respectively, and investigated the number of bays, the location of wet zone and the spatial flexibility in the housing units selected for analysis. In conclusion, the number of bays in the housing unit has gradually increased, after allowing for the structural change of the balcony in the legal. It is estimated that the trend has came from the intent to increase the numbers of the externally exposed surfaces of the balcony, ensure a good view, lighting, ventilation and spatial flexibility. The location of wet zone, water-needed space such as a bathroom or a kitchen, has changed in the direction to facilitate the expansion and modification of space. Variable range of space has gradually expanded by using the balcony and wet zone as much as possible. In order to configure more effectively spaces in housing environments, the future study should be implemented to develop tools for realizing sustainable housing environment at the levels of not only the housing unit. but also the entire building, housing site, and city.

Confinement Effectiveness on Compressive Zone of RC Walls (철근콘크리트 벽체 압축단부의 구속효과)

  • 김장훈;안상훈
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.459-464
    • /
    • 2001
  • A great level of strength and deformability on compressive zone of RC wall is essentially required when subjected to high axial and in-plane lateral loading due to earthquakes. One of the best ways to handle this situation is to provide the confinement effectiveness to the compressive zone by reinforcing steel. For this a series of design charts were constructed to evaluate the confinement effectiveness for a given steel configuration in accordance with a well-known model and part of them are presented in this paper. Using the chart, designers can choose a desirable steel arrangement in flexural compressive zone of RC walls for a prescribed confinement factor.

  • PDF

Study on the Fire Hazard and Risk Analysis Derived from the Plant Configuration Change During the Shutdown Period at Nuclear Power Plants

  • Jee Moon-Hak;Hong Sung-Yull;Sung Chang-Kyung;Jung Hyun-Jong
    • Nuclear Engineering and Technology
    • /
    • v.35 no.6
    • /
    • pp.547-555
    • /
    • 2003
  • Fire hazard and risk analysis at Nuclear Power Plants is implemented on the basis of the normal operational configuration. This steady configuration, however, can be changed due to the temporary displacement of equipment, electric cable and irregular movement of workers through the fire compartments when the on-line maintenance is processed during the power operation mode or the scheduled outage mode for the refueling. With the consequence of this configuration change, the fire analysis condition and the evaluation result will be different from those that were analyzed based on the steady configuration. In this context, at this paper, the general items for the reassessment are categorized when the configuration has changed. The contemporary zone models for the detail fire analysis are also illustrated for their application for each classified condition.

Correlation Analysis of Control Factors in Automatic Exposure Control of Digital Radiography System Based on Fine Contrast Images (미세 대조도 영상을 기반한 디지털 방사선 영상 시스템의 자동노출제어 조절인자 간의 상관관계 분석)

  • Lim, Se-Hun;Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.44 no.1
    • /
    • pp.1-8
    • /
    • 2021
  • The purpose of this study was to analyze the effect of automatic exposure control (AEC) control factors in digital radiography systems based on the fine contrast images using coin phantoms. The AEC control factors were targeted at the range of dominent zone, sensitivity, and density. The dominent zone was divided into cases where a single coin was used to cover the field configuration, and cases where seven coins were used to cover the field configuration. The sensitivity was classified into three stages (200, 400, 800) and the density was classified into three stages (2.5, 0, 2.5). Image quality was evaluated by signal to noise ratio (SNR) and contrast to noise ratio (CNR). Then, the automatically exposed tube current was measured. As a result, the X-ray image of seven coins obtained a result value of about 1.2 times higher for SNR and 1.9 times higher for CNR than the X-ray image for one coin. The tube current was also about 1.6 times higher. In conclusion, In AEC, the higher the field configuration and dominent zone are matched and the higher the density, the lower the sensitivity, which increases the tube current and CNR, which increases the image quality. Therefore, it is judged that the appropriate setting of the range of dominent zone, sensitivity, and density of the control, which is the AEC control factor, could improve the fine contrast of images.

A Study on the Architectural Planning of Spatial Composition and Circulation in Private Regional Infectious Disease Hospital (민간 권역 감염병 전문병원의 공간구성 및 동선에 관한 건축계획 연구)

  • Choi, Kwangseok;Jeong, Dawoon;Kwon, Soon Jung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.25 no.4
    • /
    • pp.81-91
    • /
    • 2019
  • Purpose: Since infectious disease hospitals are premised on emergency operations, the operational efficiency of secured personnel, equipment, facilities, etc. is relatively low. In order to increase such normal operational efficiency, it is necessary to flexibly operate facilities and operations during normal and emergency times. The purpose of this study is to suggest the architectural planning method focusing on the space composition and circulation of the regional infectious disease hospital which can increase the operational efficiency in the private hospitals. Methods: Through literature review, functional requirements of infectious disease hospitals were identified, and related personnels inter-views and field surveys were conducted to understand the spatial composition and circulation requirements of infectious disease hospitals. Results: Through the complete separation between the negative pressure zone and the general zone, even when the negative pressure zone is completely closed, the general zone should be operated separately to achieve operational efficiency. In addition, the separation of the negative pressure zone and the general zone should simultaneously consider the optimal space configuration and movement for each function while the zone settings match in the floor plan of each department and the overall cross-sectional configuration of the hospital. Implications: Infectious disease hospitals intended to be installed in private hospitals should not apply excessive space just for safety reasons and should plan to ensure their operational efficiency.

Validation of an asymptotic zone conditional expression for turbulent burning velocity against DNS database (영역조건평균에 기초한 난류연소속도의 직접수치해법검증)

  • Kim, Soo-Youb;Huh, Kang-Y.
    • Journal of the Korean Society of Combustion
    • /
    • v.9 no.4
    • /
    • pp.1-8
    • /
    • 2004
  • Zone conditional formulation for the Reynolds average reaction progress variable is used to derive an asymptotic expression for turbulent burning velocity. New DNS runs are performed for validation in a statistically one dimensional steady state configuration. Parametric study is performed with respect to turbulent intensity, integral length scale, density ratio and laminar flame speed. Results show good agreement between DNS results and the asymptotic expression in terms of measured maximum flame surface density and estimated turbulent diffusivity in unburned gas.

  • PDF

Validation of an asymptotic zone conditional expression for turbulent burning velocity against DNS database (영역조건평균에 기초한 난류연소속도의 직접수치해법검증)

  • Kim, Soo-Youb;Huh, Kang-Y.
    • 한국연소학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.62-69
    • /
    • 2004
  • Zone conditional formulations for the Reynolds average reaction progress variable are used to derive an asymptotic expression for turbulent burning velocity. New DNS runs are performed for validation in a statistically one dimensional steady state configuration. Parametric study is performed with respect to turbulent intensity, integral length scale, density ratio and laminar flame speed. Results show good agreement between DNS results and the asymptotic expression in terms of measured maximum flame surface density and estimated turbulent diffusivity in unburned gas.

  • PDF

Oscillatory Thermocapillary Flow in Cylindrical Columns of High Prand시 Number Fluids

  • Lee, Kyu-Jung;Yasuhiro Kamotani;Simon Ostrach
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.6
    • /
    • pp.764-775
    • /
    • 2001
  • Oscillartory thermocapillary flow of high Prandtl number fluids in the half-zone configuration is investigated. Based on experimental observations, one oscillation cycle consists of an active period where the surface flow is strong and the hot corner region is extended and a slow period where the opposite occurs. It is found that during oscillations the deformation of free surface plays an important role and a surface deformation parameter S correlates the experimental data well on the onset of oscillations. A scaling analysis is performed to analyze the basic steady flow in the parametric ranges of previous ground-based experiments and shows that the flow is viscous dominant and is mainly driven in the hot corner. The predicted scaling laws agree well with the numerical results. It is postulated that the oscillations are caused by a time lag between the surface and return flows. A deformation parameter S represents the response time of the return flow to the surface flow.

  • PDF