• Title/Summary/Keyword: The City Structures

Search Result 606, Processing Time 0.032 seconds

Raffles City in Hangzhou China -The Engineering of a 'Vertical City' of Vibrant Waves-

  • Wang, Aaron J.
    • International Journal of High-Rise Buildings
    • /
    • v.6 no.1
    • /
    • pp.33-47
    • /
    • 2017
  • This mixed-use Raffles City (RCH) development is located near the Qiantang River in Hangzhou, the capital of Zhejiang province, located southwest of Shanghai, China. The project incorporates retail, offices, housing, and hotel facilities and marks the site of a cultural landscape within the Quianjiang New Town Area. The project is composed of two 250-meter-tall twisting towers with a form of vibrant waves, along with a commercial podium and three stories of basement car parking. It reaches a height of 60 stories, presenting views both to and from the Qiantang River and West Lake areas, with a total floor area of almost 400,000 square meters. A composite moment frame plus concrete core structural system was adopted for the tower structures. Concrete filled steel tubular (CFT) columns together with steel reinforced concrete (SRC) beams form the outer moment frame of the towers' structure. The internal slabs and floor beams are of reinforced concrete. This paper presents the engineering design and construction of this highly complex project. Through comprehensive discussion and careful elaboration, some conclusions are reached, which serve as a reference guide for the design and construction of similar free-form, hybrid, mix-use buildings.

Use of Architectural Heritage for the Conservation of Historic Urban Environment -Kurazukuri Buildings in the city of Kawagoe, Japan- (역사적 도시환경보존을 위한 건축문화재 활용방안 연구 -일본(日本) 카와고에시(川越市) 쿠라츠쿠리(藏造り)를 중심으로-)

  • Hwangbo, A.B.
    • KIEAE Journal
    • /
    • v.14 no.3
    • /
    • pp.121-126
    • /
    • 2014
  • Many cities in Japan retain older city structures with buildings in traditional form and style. Visitors are fascinated by charms and tranquility of pre-modern life styles. Architectural features of olden days are well conserved or carefully restored on purpose. In the case of Kawagoe city near Tokyo, local residents are largely replete with visitors without being necessarily aware of slow commodification of historic spaces. Kawagoe is yet socio-culturally sustainable and financially fit. This paper intends to analyse conservation strategies, with focus on architectural heritage, taken for the historic city of Kawagoe. With the population of 300,000 in the suburb of Tokyo, it is one of the best known historic cities in Japan. Kawagoe grew as a merchant city since 1700s, and it once reached to a major port of silk trade en-route to Edo (Tokyo) from northen provinces. Tourism industry is discovered as a key element in the conservation strategies applied to revitalize historic city center, Ichibangai, an important cultural heritage site with special reference to kurazukuri. This paper argues that augmentation of conceptions in architectural heritage is not only advantageous for the conservation of historic urban environment but it also provides opportunities for sustainable urban renewal.

Particle filter for model updating and reliability estimation of existing structures

  • Yoshida, Ikumasa;Akiyama, Mitsuyoshi
    • Smart Structures and Systems
    • /
    • v.11 no.1
    • /
    • pp.103-122
    • /
    • 2013
  • It is essential to update the model with reflecting observation or inspection data for reliability estimation of existing structures. Authors proposed updated reliability analysis by using Particle Filter. We discuss how to apply the proposed method through numerical examples on reinforced concrete structures after verification of the method with hypothetical linear Gaussian problem. Reinforced concrete structures in a marine environment deteriorate with time due to chloride-induced corrosion of reinforcing bars. In the case of existing structures, it is essential to monitor the current condition such as chloride-induced corrosion and to reflect it to rational maintenance with consideration of the uncertainty. In this context, updated reliability estimation of a structure provides useful information for the rational decision. Accuracy estimation is also one of the important issues when Monte Carlo approach such as Particle Filter is adopted. Especially Particle Filter approach has a problem known as degeneracy. Effective sample size is introduced to predict the covariance of variance of limit state exceeding probabilities calculated by Particle Filter. Its validity is shown by the numerical experiments.

Landscape pattern analysis from IKONOS image data by wavelet and semivariogram method

  • Danfeng, Sun;Hong, Li
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.1209-1211
    • /
    • 2003
  • The wavelet and semivariogram analysis method are used to identify the city landscape and farmland landscape pattern on the 1m resolution IKONOS images. The results prove that wavelet method is a potential way for landscape pattern analysis. Compared to semivariogram analysis, Wavelet analysis can not only detect the overall spatial pattern, but also find multi-scale and direction structures. In this experiment, the wavelet analysis results indicate: (1) the city landscape image is mainly composed of three level structures whose spatial pattern characters appear at 2m, 16m, 128m and 256m accordingly; (2) the farmland landscape is mainly two scale spatial patterns appearing at the 2m, 128m and 256m. IKONOS Remote sensing, with the high spatial and spectral information, is a powerful tool that can use in many ecological systems research and sustainable management.

  • PDF

Joints: the weak link in bridge structures and lifecycles

  • Yanev, Bojidar
    • Smart Structures and Systems
    • /
    • v.15 no.3
    • /
    • pp.543-553
    • /
    • 2015
  • The condition of the vehicular bridge network in New York City, as represented by ratings obtained during biennial inspections is reviewed over a period of three decades. Concurrently, the bridges comprising the network are considered as networks of structural elements whose condition defines the overall bridge condition according to New York State assumptions. A knowledge-based matrix of assessments is used in order to determine each element's vulnerability and impact within the network of an individual structure and the network of City bridges. In both networks expansion deck joints emerge as the weak link. Typical joint failures are illustrated. Bridge management options for maintenance, preservation, rehabilitation and replacement are examined in the context of joint performance.

Grounding Resistance Measurement and Analysis of Building Structures for Applying as Safety Earthing (보호접지로 활용하기 위한 건축물 구조체의 접지저항 측정분석)

  • Oh, Se-Jung;Kim, Chan-O
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.8
    • /
    • pp.50-55
    • /
    • 2012
  • Grounding is very important for electrical safety. But it is very difficult to secure enough space for the installation and management of grounding in the city because of the congestion of the buildings. Therefore, to solve this problem, this paper suggest structure-grounding application taking advantage of building structure as protective grounding. And, to verify its feasibility, this paper shows the result to measure and analyze grounding-resistance of structure for 12 buildings mainly structed in the city.

Establishment of the Measurement Model about the Adequate Urban Development Density using System Dynamics (시스템다이내믹스를 활용한 도시개발밀도의 적정성 평가 모델 구축 연구)

  • 전유신;문태훈
    • Proceedings of the Korean System Dynamics Society
    • /
    • 2003.08a
    • /
    • pp.1-24
    • /
    • 2003
  • The purpose of this paper was developing a development density control model for urban growth management, using system dynamics modeling. The density control model was developed to see how urban growth, transition, and decay occur depending on the interaction among population, houses, industry structure, land and urban infrastructure such as road, water supply, and sewage treatment facilities. Suggesting adequate level of development density control using the model was another purpose of this paper. The model was applied to An'yang city to estimate the maximum number of population, industry structures, houses, and cars that can be adequately sustained with the current An'yang city's infrastructur capacity. The computer simulation results shows that the city is overpopulated by some 90,000 people. To reduce the population to the adequate level that the current urban infrastructure can sustain, the current city regulation on floor area ratio are needed to be strengthened at least 20 to 35%.

  • PDF

3D City Model Construction using Low Altitude Aerial Photography (저고도 항공사진을 이용한 3차원 도시 모형 구축)

  • Jung, Sung-Heuk
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2010.04a
    • /
    • pp.249-250
    • /
    • 2010
  • The study aims to propose a method that shall rapidly acquire 3D spatial information of the frequently changing city areas by using the low altitude aerial images taken by the UAV. The artificial 3D model of the artificial structures was constructed using the aerial image data photographed at the test area, calibration data of the non-metric camera and the results of the ground control point survey. Also, the digital surface model was created for areas that were changed due to a number of civil works. Through the above studies, the possibilities of constructing a 3D virtual city model, renewal of 3D GIS database, abstraction of changed information in geographic features and on-demand updating of the digital map were suggested.

  • PDF

Feedback control design for intelligent structures with closely-spaced eigenvalues

  • Cao, Zongjie;Lei, Zhongxiang
    • Structural Engineering and Mechanics
    • /
    • v.52 no.5
    • /
    • pp.903-918
    • /
    • 2014
  • Large space structures may have resonant low eigenvalues and often these appear with closely-spaced natural frequencies. Owing to the coupling among modes with closely-spaced natural frequencies, each eigenvector corresponding to closely-spaced eigenvalues is ill-conditioned that may cause structural instability. The subspace to an invariant subspace corresponding to closely-spaced eigenvalues is well-conditioned, so a method is presented to design the feedback control law of intelligent structures with closely-spaced eigenvalues in this paper. The main steps are as follows: firstly, the system with closely-spaced eigenvalues is transformed into that with repeated eigenvalues by the spectral decomposition method; secondly, the computation for the linear combination of eigenvectors corresponding to repeated eigenvalues is obtained; thirdly, the feedback control law is designed on the basis of the system with repeated eigenvalues; fourthly, the system with closely-spaced eigenvalues is regarded as perturbed system on the basis of the system with repeated eigenvalues; finally, the feedback control law is applied to the original system, the first order perturbations of eigenvalues are discussed when the parameter modifications of the system are introduced. Numerical examples are given to demonstrate the application of the present method.

Performance of structures and infrastructure facilities during an EF4 Tornado in Yancheng

  • Tao, Tianyou;Wang, Hao;Yao, Chengyuan;Zou, Zhongqin;Xu, Zidong
    • Wind and Structures
    • /
    • v.27 no.2
    • /
    • pp.137-147
    • /
    • 2018
  • Heavy damages to properties with attendant losses were frequently caused by tornadoes in recent years. This natural hazard is one of the most destructive wind events that must be fully studied and well understood in order to keep the safety of structures and infrastructure facilities. On June 23, 2016, a severe tornado, which is an Enhanced Fujita (EF) 4 storm, occurred in the rim of a coastal city named as Yancheng in China. Numerous low-rise buildings as well as facilities (e.g., transmission towers) were destroyed or damaged. In this paper, damages to structures and infrastructure facilities by the severe tornado are reviewed. The collapses of residential buildings, industrial structures and other infrastructure facilities are described. With an overview of the damages, various possible mechanisms of the collapse are then discussed and utilized to reveal the initiation of the damage to various facilities. It is hoped that this paper can provide a concise but comprehensive reference for the researchers and engineers to help understand the tornado effects on structures and expose the vulnerabilities that need to be improved in current wind-resistant design practices.