• Title/Summary/Keyword: Thallium-201

Search Result 68, Processing Time 0.025 seconds

Is $^{201}Tl-^{99m}Tc$-Subtraction Scan an Accurate Diagnostic Method to Detect Parathyroid Mass? ($^{201}Tl/^{99m}Tc$ 감영스캔으로 부갑상선종괴를 얼마나 찾을 수 있는가?)

  • Yang, Hyung-In;Kim, Deog-Yoon;Kim, Kwang-Won;Choi, Young-Kil
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.1
    • /
    • pp.31-36
    • /
    • 1994
  • We studied 65 patients with hypercalcemia who had heed performed $^{201}Tl/^{99m}Tc$ subtraction scan, 21 of them were confirmed as parathyroid tumor (19 adenoma, 2 carcinoma). The diagnostic sensitivity of $^{201}Tl/^{99m}Tc$ subfraction scan for detecting parathyroid mass was 90.5%, specificity was 97.6%, ultrasonography was 80.6%, 58.8%, respectively. The causes of two false negative cases were relatively small size ($1.5{\times}1{\times}0.8cm$) compared to remainig cases and poor thallium uptake due to cystic necrosis of parathyroid adenoma. The one false positive case was non-functioning thyroid nodule. $^{201}Tl/^{99m}Tc$ subtraction scan was simple, effective diagnostic tool and superior to ultrasonography for evaluating the parathyroid mass with high sensitivity and specificity.

  • PDF

Thallium-201 SPECT in Differential Diagnosis of Malignancy from Benign Pathology in Patients with a Solitary Pulmonary Lesion (단일 폐병변에서 T1-201 SPECT를 이용한 악성 종양의 감별진단)

  • Ahn, Byeong-Cheol;Lee, Jae-Tae;Chun, Kyung-Ah;Kim, Dong-Hwan;Sohn, Sang-Kyun;Kim, Chang-Ho;Park, Jae-Yong;Jeong, Tae-Hoon;Lee, Kyu-Bo;Kim, Chun-K.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.2
    • /
    • pp.143-150
    • /
    • 1998
  • Purpose: T1-201 SPECT has been used in differentiating benign and malignant pulmonary lesions. While its sensitivity may be high, the specificity and predictive values are reported to be variable depending on the type of benign lung lesion. The purpose of this study was to prospectively assess the efficacy of T1-201 SPECT for differentiating benign and malignant single pulmonary lesion in a population with a high prevalence of benign pulmonary lesion, especially, tuberculosis. Materials and Methods: One-hundred thirty-three patients, having 89 malignant and 44 benign lesions(23 active tuberculosis, 5 inactive tuberculosis, 3 aspergil-loma, 3 focal pneumonia, 2 thymoma, and 8 others), were imaged using a dual-headed system at 15 minute(early) and 3 hour (delayed) following administration of 111MBq T1-201. The images were read visually and lesion-to-background ratios(L/B) were obtained from transverse tomographic slices. Retention index was expressed as [(delayed L/B- early L/B) $\div$ early L/B]. Results: 82/89(92%) and 83/89(93%) of the malignant lesions were visually positive on the early and delayed images, and 27/44(61%) and 26/44(59%) of the benign lesions were also visually positive on both images. Although a statistically significant difference was found between the mean L/B's of the malignant and benign lesions, L/B was not useful for differentiating the two due to a large overlap. There was no difference in retention indices. Conclusion: Despite of its high sensitivity, the specificity of T1-201 SPECT was unacceptably low in patients with active benign lesions. The positive and negative predictive values for lung cancer in a population with a high prevalence of the benign single pulmonary lesion was only marginal.

  • PDF

Quantitative Analysis of Thallium-201 Myocardial Tomograms (Thallium-201 심근 단층영상의 정량적 분석)

  • Kim, Sang-Eun;Nam, Gi-Byoung;Choi, Chang-Woon;Choi, Kee-Joon;Lee, Dong-Soo;Sohn, Dae-Won;Ahn, Cu-Rie;Chung, June-Key;Lee, Myoung-Mook;Lee, Myung-Chul;Park, Young-Bae;Choi, Yun-Shik;Seo, Jung-Don
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.2
    • /
    • pp.165-176
    • /
    • 1991
  • The purpose of this study was to assess the ability of quantitative Tl-201 tomography to identify and localize coronary artery disease (CAD). The study population consisted of 41 patients (31 males, 10 females; mean age $55{\pm}7$ yr) including 14 with prior myocardial infarction who underwent both exercise Tl-201 myocardium SPECT and coronary angiography for the evaluation of chest pain. From the short axis and vertical long axis tomograms, stress extent polar maps were generated by Cedars-Sinai Medical Center program, and the % stress defect extent (SDE) was quantified for each coronary artery territory. For the purpose of this study, the coronary circulation was divided into 6 arterial segments, and the "myocardial ischemic score" (MIS) was calculated from the coronary angiogram. Sensitivity for the detection of CAD ($\geq50%$ coronary stenosis by angiography) by angiography) by stress extent polar map was 95% in single vessel disease, and 100% in double and triple vessel deseases. Overall sensitivity was 97%. Sensitivity and specificity for the detection of individual diseased vessels were, respectively, 87% and 90% for the left anterior descending artery (LAD), 36% and 93% for the left circumflex artery (LCX), and 71% and 70% for the right coronary artery (RCA). Concordance for the detection of individual diseased vessels between the coronary angiography and stress polar map was fair for the LAD (kappa=0.70), and RCA (kappa=0.41) lesions, whereas it was poor for the LCX lesions (kappa : 0.32). There were siginificant correlations between the MIS and SDE in LAD (rs=0.56, p=0.0027), and RCA territory (rs=0.60, p=0.0094). No significant correlation was found in LCX territory. When total vascular territories were combined, there was a significant correlation between the MIS and SDE (rs=0.42, p=0.0116). In conclusion, the quantitative analysis of Tl-201 tomograms appears to be accurate for determining the presence and location of CAD.

  • PDF

Stress Testing and Imaging Protocols for Myocardial Perfusion Studies (심근관류영상을 위한 심근부하 방법 및 검사 프로토콜)

  • Kim, Seong-Min
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.3
    • /
    • pp.179-195
    • /
    • 2009
  • Scince $^{201}$TI was introduced as a myocardial perfusion imaging agent in the early 1970s, scintigraphic evaluation of myocardial perfusion for the diagnosis of coronary artery disease is a valuable noninvasive diagnostic imaging modality. Stress radionuclide myocardial perfusion imaging is widely accepted to have high diagnostic and prognostic use in the assessment of patients with known or suspected coronary artery disease. With wise use of this nonivasive imaging technique, more patients are referred for stress perfusion imaging. Until now various protocols for stress testing and myocardial imaging were developed and used in worldwide. This article presented various protocols of stress testing and myocardial imaging for clinical use.

Reproducibility of Gated Myocardial Perfusion SPECT for the Assessment of Myocardial Function: Comparison with Thallium-201 and Technetium-99m-MIBI (심근 기능 측정에 사용된 게이트 심근 관류 SPECT 방법의 재현성 평가: $^{201}Tl$$^{99m}Tc$-MIBI 게이트 SPECT의 비교)

  • Hyun, In-Young;Seo, Jeong-Kee;Hong, Eui-Soo;Kim, Dae-Hyuk;Kim, Sung-Eun;Kwan, Jun;Park, Keum-Soo;Choe, Won-Sick;Lee, Woo-Hyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.5
    • /
    • pp.381-392
    • /
    • 2000
  • Purpose: We compared the reproducibility of $^{201}Tl\;and\;^{99m}Tc$-sestamibi (MIBI) gated SPECT measurement of myocardial function using the Germano algorithm Materials and Methods: Gated SPECT acquisition was repeated in the same position in 30 patients who received $^{201}Tl$ and in 26 who received $^{99m}Tc$-MIBI. The quantification of end-diastolic volume (EDV), end-systolic volume (ESV), and ejection fraction (EF) on $^{201}Tl\;and\;^{99m}Tc$-MIBI gated SPECT was processed independently using Cedars quantitative gated SPECT software. The reproducibility of the assessment of myocardial function on $^{201}Tl$ gated SPECT was compared with that of $^{99m}Tc$-MIBI gated SPECT Results: Correlation between the two measurements for volumes and EF was excellent by the repeated gated SPECT studies of $^{201}Tl$ (r=0.928 to 0.986; p<0.05) and $^{99m}Tc$-MIBI (r=0.979 to 0.997; p<0.05). However, Bland Altman analysis revealed the 95% limits of agreement (2 SD) for volumes and EF were tighter by repeated $^{99m}Tc$-MIBI gated SPECT (EDV: 14.1 ml, ESV: 9.4 ml and EF: 5.5%) than by repeated $^{201}Tl$ gated SPECT (EDV: 24.1 ml, ESV: 18.6 ml and EF: 10.3%). The root mean square (RMS) values of the coefficient of variation (CV) for volumes und EFs were smaller by repeated $^{99m}Tc$-MIBI gated SPECT (EDV: 2.1 ml, ESV 2.7 ml and EF: 2.3%) than by repeated $^{201}Tl$ gated SPECT (EDV: 3.2 ml, ESV: 3.5 ml and EF: 5.2%). Conclusion: $^{99m}Tc$-MIBI provides more reproducible volumes and EF than $^{201}Tl$ on repeated acquisition gated SPECT. $^{99m}Tc$-MIBI gated SPECT is the preferable method for the clinical monitoring of myocardial function.

  • PDF

Comparison of Thallium-201, Tc-99m MIBI and I-131 Scan in the Follow-up Assessment after I-131 Ablative Therapy in Differentiated Thyroid Cancer (방사성 옥소 치료 후 분화된 갑상선암 추적관찰에서 Thallium-201 스캔, Tc-99m MIBI 스캔과 I-131 스캔 검사 결과의 비교)

  • Kwon, Jae-Sung;Lee, Sung-Keun;Kim, Doe-Min;Park, Sae-Jong;Jang, Kyong-Sun;Kim, Eun-Sil;Kim, Chong-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.6
    • /
    • pp.493-501
    • /
    • 1999
  • Purpose: We conducted a comparative study to evaluate the diagnostic values of T1-201, Tc-99m MIBI and I-131 scans in the follow-up assessment after ablative I-131 therapy in differentiated thyroid cancer. Materials and Methods: The study population consisted of 20 patients who underwent surgical removal of thyroid cancer and ablative radioactive iodine therapy, and followed by one or mote times of I-131 retreatments (33 cases). In all patients, T1-201, Tc-99m MIBI, diagnostic and therapeutic I-131 scans were performed and the results were analyzed retrospectively. Also serum thyroglobulin levels were measured in all patients. The final diagnosis of recurrent or metastatic thyroid cancer was determined by clinical, biochemical, radiologic and/or biopsy findings. Results: Positive rates (PR) of Tc-99m MIBI, T1-201, diagnostic and therapeutic I-131 scans in detecting malignant thyroid tissue lesions were 70% (19/27), 54% (15/28), 35% (17/48) and 63% (30/48), respectively. The PR in the group of 20 cases (28 lesions) who underwent concomitant T1-201 and I-131 scans were in the order of therapeutic 131 scan 71%, T1-201 scan 54% and diagnostic I-131 scan 36%. There was no statistically significant difference between T1-201 and diagnostic I-131 scans (p>0.05). In the group of 20 cases (27 lesions) who underwent concomitant Tc-99m MIBI and I-131 scans, the PR were in the order of Tc-99m MIBI scan 70%, I-131 therapeutic scan 52% and I-131 diagnostic scan 33%. The PR of Tc-99m MIBI was significantly higher than that of diagnostic I-131 scan (p<0.05). Conclusion: Tc-99m MIBI scan is superior to diagnostic I-131 scan in detecting recurrent or metastatic thyroid cancer following ablation therapy in patients with differentiated thyroid cancer. T1-201 scan did not showed significantly higher positive rate than diagnostic I-131 scan. Instead of diagnostic I-131 scan before the I-131 retreatment, Tc-99m MIBI scan without discontinuing thyroid hormone replacement would be a prudent and effective approach in the management of these patients.

  • PDF

Thallium-201 SPECT in the Evaluation of Postoperative Tumor Recurrence on the Chest Wall in Lung Cancer (폐암 수술 후 흉벽의 종양 재발 검출에 있어 Tl-201 폐 SPECT의 유용성)

  • Ryu, Young-Hoon;Kim, Hyung-Jung;Ahn, Chul-Min;Kim, Se-Kyu;Paik, Hyo-Chae;Lee, Doo-Yun;Chung, Kyung-Young;Yune, Min-Jin;Park, Sang-Jung;Moon, Sung-Wook;Kim, Sang-Jin;Lee, Jong-Doo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.5
    • /
    • pp.542-549
    • /
    • 2002
  • Purpose : The purpose of our study was to assess the usefulness of the Tl-201 SPECT for the detection of the postoperative tumor recurrence on chest wall. Methods: 28 patients including 14 with suspected recurrence of tumor in the chest wall on postoperative chest cr scan, 10 with postoperative pleural effusion which proved benign on radiologic, cytologic and laboratory findings, and 4 with chronic tuberculous empyema as control group were included. All patients underwent SPECT 30 minutes and 4 hours after intravenous injection of 111MBq of Tl-201. Tumor uptake was visually graded by two interpreters and scored as follows : no uptake:0, similar to contralateral lung: 1, higher than contralateral lung but less than heart:2 and similar to heart:3. Results : Markedly increased (grade 3 or 2) Tl-201 uptake was noted in patients with suspected recurrence of tumor in the chest wall (13/14) whereas no (8/10) or minimal (2/10) uptake along the collapsed lung in patients with postoperative benign pleural effusion. In two patients, Tl-201 SPECT revealed additional recurrent tumor mass lesions that were barely perceptible on chest cr scan. Patients with chronic tuberculous empyema showed relatively smoothly marginated increased uptake along the chest wall 4/4), but lesser in degree (grade 1 or 2), when compared to recurrent tumor uptake. Conclusion : Tl-201 lung SPECT seems to be useful to detect postoperative tumor recurrence on chest wall and to differentiate malignant from benign pleural effusion and may provide additional information to the morphologic data obtained by CT.

Nitroglycerin-Challenged Tc-99m MIBI Quantitative Gated SPECT to Predict Functional Recovery After Coronary Artery Bypass Surgery (니트로글리세린 투여 Tc-99m-MIBI 정량 게이트 심근SPECT를 이용한 관상동맥우회로술 후 심근 기능 회복 예측)

  • Lee, Dong-Soo;Kim, Yu-Kyeong;Cheon, Gi-Jeong;Paeng, Jin-Chul;Lee, Myoung-Mook;Kim, Ki-Bong;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.5
    • /
    • pp.278-287
    • /
    • 2003
  • Purpose: The performance of nitroglycerin-challenged Tc-99m-MIBI quantitative gated SPECT for the detection of viable myocardium was compared with rest/24-hour redistribution Tl-201 SPECT Materials and Methods: In 22 patients with coronary artery disease, rest Tl-20l/ dipyridamole stress Tc-99m-MIBI gated/24-hour redistribution Tl-201 SPECT were peformed, and gated SPECT was repeated on-site after sublingual administration of nitroglycerin (0.6 mg). Follow-up gated SPECT was done 3 months after coronary artery bypass graft surgery. For 20 segments per patient, perfusion at rest and 24-hour redistribution, and wall motion and thickening at baseline and nitroglycerin-challenged state were quantified. Quantitative viability markers were evaluated and compared;(1) rest thallium uptake, (2) thallium uptake on 24-hour redistribution SPECT, (3) systolic wall thickening at baseline, and (4) systolic wall thickening with nitroglycerin-challenge. Results: Among 100 revascularized dysfunctional segments, wall motion improved in 66 segments (66%) on follow-up gated myocardial SPECT after bypass surgery. On receiver operating characteristic (ROC) curve analysis, the sensitivity and specificity of rest and 24-hour delayed redistribution Tl-201 SPECT were 79%, 44% and 82%, 44%, respectively, at the optimal cutoff value of 50% of Tl-201 uptake. The sensitivity and specificity of systolic wall thickening at baseline and nitroglycerin-challenge were 49%, 50% and 64%, 65% at the optimal cutoff value of 15% of systolic wall thickening. Area under the ROC curve of nitroglycerin-challenged systolic wall thickening was significantly larger than that of baseline systolic wall thickening (p=0.004). Conclusion: Nitroglycerin-challenged quantitative gated Tc-99m-MIBI SPECT was a useful method for predicting functional recovery of dysfunctional myocardium.

Radiolabelled Monoclonal Antibodies (McAb): An Alternate Approach to the Conventional Methods for the Assessment of Cardiomyocyte Damage in an Experimental Brain-Death Pig Model

  • Haider, Kh.H.;Stimson, W.H.
    • Archives of Pharmacal Research
    • /
    • v.21 no.5
    • /
    • pp.496-502
    • /
    • 1998
  • The present study was carried out to determine the possible use of cTn-I in the cardiac myofibrillar architecture, as a potential target for in vivo radioimmunodetection of cardiac damage in a brain death pig model. Radioiodiantion of the anti-cTn-I 5F4 McAb was carried out by lactoperoxidase method. the percentage iodine incorporation achieved was 70-75%. The radioiodinated McAbs were purified on Sephadex G-25 column and characterised by Paper chromatography, Phast Gel electrophoresis and electroimmunoblotting. Radioiodinated anticTn-I 5F4 McAbs were employed alongside Pyrophosphate($Tc_{99m}$-PPi$) and $Thallium^{201}$ chloride($TI^{201}$) in 24 landrace pigs (brain-dead=18 & sham-operated=6). The percentage cardiac uptake of the radiolabelled antibody injected dose was significantly higher in the brain dead animals(0.196%) as compared to that of sham-operated animals (0.11%). Specific in vivo localization of radiolabelled McAbs in the infarcted cardiac tissue was confirmed by computer-aided reconstruction of 3-D images of the isolated heart. The preliminary results of the study revealed preferential uptake of radiolabelled antibody at the site of myocyte damage resulting from artificially induced brain death.

  • PDF

A Study on Optimal Myocardium Perfusion SPECT According to Possible Myocardial Infarct Sites (8) 예측성 경색 부위별 최적의 심근관류 단층촬영술 시행에 관한 연구)

  • Song Jae Beom;Lee Wan Kyu;Shu Myung Duk;Jang Sang Sup
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.25 no.1
    • /
    • pp.234-252
    • /
    • 1999
  • Purpose : Physical properties of radiophamaceuticals of technetium($^{99m}Tc$) and thallium($^{201}Tl$) have early been used for clinical diagnostics. The studies of those radiophamaceuticals have been contributed to the efficient to

  • PDF