• 제목/요약/키워드: Testing temperature

검색결과 1,542건 처리시간 0.031초

오스테나이트계 스테인레스 강관에서의 손상해석에 관한 연구 (Failure Analysis of Austenitic Stainless Steel Pipe)

  • 이상율;이종오;이주석;조경식;조종춘;이보영
    • Journal of Welding and Joining
    • /
    • 제11권1호
    • /
    • pp.21-32
    • /
    • 1993
  • A cracking failure of a austenitic stainless steel elbow in a naphtha cracking line in a petrochenmical plant occurred, resulting in leakage of organic compound flowing inside the elbow. Due to the failure, emergency shutdown of the plant was enforced to repair the troubled part of the line. The repair cost as well as production loss during the unscheduled plant shutdown has cost the company a great amount of financial loss. In this studies, a failure analysis of the cracked elbow was performed using NDT, chemical analysis, microstructural analysis including optical microscopy as well as scanning electron microscopy with EPMA, mechanical testings such as tensile testing, hardness testing and Charphy impact test fractography. The results indicated that several problems such as a welding defect and presence of a detrimental phase which was found to be relate to improper postforming heat treatment process was identified and the failure was concluded to be due to a low temperature embrittlement of the defect-containing elbows.

  • PDF

Contour Integral Method for Crack Detection

  • Kim, Woo-Jae;Kim, No-Nyu;Yang, Seung-Yong
    • 비파괴검사학회지
    • /
    • 제31권6호
    • /
    • pp.665-670
    • /
    • 2011
  • In this paper, a new approach to detect surface cracks from a noisy thermal image in the infrared thermography is presented using an holomorphic characteristic of temperature field in a thin plate under steady-state thermal condition. The holomorphic function for 2-D heat flow field in the plate was derived from Cauchy Riemann conditions to define a contour integral that varies according to the existence and strength of a singularity in the domain of integration. The contour integral at each point of thermal image eliminated the temperature variation due to heat conduction and suppressed the noise, so that its image emphasized and highlighted the singularity such as crack. This feature of holomorphic function was also investigated numerically using a simple thermal field in the thin plate satisfying the Laplace equation. The simulation results showed that the integral image selected and detected the crack embedded artificially in the plate very well in a noisy environment.

수직온도분포 분석을 이용한 몰드변압기 권선의 건전성 평가 연구 (A Study on the Integrity Evaluation of the Windings in Cast Resin Transformers Using Vertical Thermal Distribution Analysis)

  • 김홍래;임용배
    • 조명전기설비학회논문지
    • /
    • 제19권2호
    • /
    • pp.94-99
    • /
    • 2005
  • 본 논문은 수직온도분포 분석을 이용한 몰드변압기 권선의 건전성 평가 방법을 제시하고 있다. 이 방법은 건전 시료의 온도 분포와 가속열화실험에 의해 층간 단락된 고장시료의 온도 분포 비교를 통해 얻어진 결과이다. 분석에 활용된 온도분포는 적외선 열화상 시스템에 의해 취득되었고, 가속 열화시험에는 Arrhenius 방정식이 적용되었다. 제안된 방법은 몰드변압기 고장을 검출하는데 유용할 것이다.

6.6kV급 고온초전도 한류기용 HTS 코일의 절연 설계 및 시험 (Insulation Design and Testing of HTS coil for 6.6 kV Class HTSFCL)

  • 백승명;정종만;곽동순;류엔반둥;김상현
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.263-268
    • /
    • 2003
  • The Electrical insulation design and testing of high temperature superconducting (HTS) coil for high temperature superconducting fault current limiter (HTSFCL) has been performed. Electrical insulating factors of HTS coil for HTSFCL are turn-to-turn, layer-to-layer. The electrical insulation of turn-to-turn depends on surface length, and the electrical insulation of layer-to-layer depends on surface length and breakdown strength of L$N_2$. Therefore, two basic characteristics of breakdown and flashover voltage were experimentally investigated to design electrical insulation for 6.6㎸ Class HTSFCL. We used Weibull distribution to set electric field strength for insulation design. And mini-model HTS coil for HTSFCL was designed by using Weibull distribution and was manufactured to investigate breakdown characteristics. The mini-model HTS coil had passed in AC and Impulse withstand test.

  • PDF

차량 연료시스템에서의 정전기 축적특성 연구 (A Study on Electrostatic Charging Characteristics in Vehicle Fuel Systems)

  • 서준호;나병철;김진용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.2157-2162
    • /
    • 2004
  • As the friction between two mated materials generates electrostatic voltage, vehicles especially in the cold climate has been accumulated an electrostatic voltage by the reason of fuel flow in the fuel line, air flows out side of vehicle, etc. In this study, investigations of electrostatic discharge characteristics has been carried out in the fuel systems of gasoline engines depending on the environment temperature. For the experiment, conventional fuel filters(paint coated steel case) and specially made testing equipment are prepared. The experimental results shows, an accumulation speed of electrostatic voltage depends on the environmental temperature and new methods of testing procedures are required compare to SAE standards.

  • PDF

Creep Lifetime Prediction of Composite Geogrids using Stepped Isothermal Method

  • Koo, Hyun-Jin;Cho, Hang-Won
    • 한국신뢰성학회:학술대회논문집
    • /
    • 한국신뢰성학회 2006년도 학술발표대회 논문집
    • /
    • pp.158-164
    • /
    • 2006
  • The creep behavior of newly developed composite geogrids which consists of PET yarns sheathed in PP were evaluated using SIM. For the SIM procedure, three test parameters, the applied loads, temperature steps and number of ribs were investigated, The study confirmed that temperature steps of 10 and 14$^{\circ}C$ up to 80$^{\circ}C$ are applicable for composite geogrids due to the different transition temperatures between two materials. At applied loads of 40 and 50%, only primary creep state was measured, while secondary creep state appeared at the applied loads of 60%, The lifetimes of composite geogrids were estimated at each of loading level using statistical reliability analysis technique. The results show that the lifetimes longer than 100 years can be predicted within 16 hours. Therefore, SIM is very effective and economical accelerated creep test methods, especially for lifetime prediction. This gives guidelines for users to select the appropriate factor of safety against creep considering the field condition within shorter test times.

  • PDF

고무 제품(製品)의 노화성(老化性)에 관(關)한 연구(硏究)(제1보(第1報)) (Studies on the Aging of Rubber Vulcanizates(PART I))

  • 허동섭;백남철
    • Elastomers and Composites
    • /
    • 제1권1호
    • /
    • pp.56-62
    • /
    • 1966
  • The aging characteristics of vulcanized rubber products manufactured in Korean industries have been studied, especially in terms of relationship between aging temperature and time, and also the comparison of results between Geer's oven testing and tube testing was made. It was assessed from changes in tensile properties resulting from conditioning at elevated temperatures for specified period of time. Even though the recipe of each sample is different, the results, as would be expected, has shown that at lower aging temperature the change of tensile strength indicate moderately and at the elovated severely as shown in Figure 9. Consequently, in spite of that the results from conditioning at various temperatures for certain specified period of time must be equivalent to each other, it shows inignorable tolerance. The results of Geer's oven test and tube test have shown slightly different value. It seemed to be caused by the result of migration phenomena on aging in Geer's oven.

  • PDF

열차 제어의 연속 제동시 마찰특성과 온도분포 (The Friction Characteristic and Distribution of Temperature in The Continuous Braking Effort on The Train Control)

  • 최경진;이시우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.55-58
    • /
    • 2005
  • During braking at a train, thermal energy is generated due to the frictions between disk and lining and wheel and shoe. In general, the braking transfers the kinetic energy into thermal energy. Therefore, the frictional characteristics are varied according to the braking force, the thermal resistance, and the thermostable, etc. Using a Dynamo testing we have studied the frictional characteristics and the thermal distribution to investigate a stable speed and to improve the testing method through comparing and analysing in the measurement of the thermocouple temperature and infrared camera.

  • PDF

블래더와 하우징으로 구성된 축압기의 수명피로예측 (Life Fatigue Prediction of an Accumulator Composed of Bladder and Housing)

  • 김대유;이건희;허장욱
    • 한국기계가공학회지
    • /
    • 제17권5호
    • /
    • pp.58-63
    • /
    • 2018
  • Recently in weapon systems development, the importance of reliability has been emphasized due to the increase in complexity and the rapid development of key components and components. Accordingly, the importance of lifespan testing is increased. However, lifespan testing to verify the reliability of a system is costly and takes a lot of time. Therefore in this paper, it was demonstrated that the most critical item of a bladder type accumulator is the bladder. Fatigue life is sensitive to temperature and pressure, with temperature having more impact. The fatigue life of the bladder was estimated to be 18,140 hr through fatigue analysis, which satisfies the required life expectancy of 10,000 hr.

금속 자기기억법 활용 보일러 튜브의 미소 결함 검출력 연구 (Study of Boiler Tube Micro Crack Detection Ability by Metal Magnetic Memory)

  • 서정석;명주홍;방지예;정계조
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권2호
    • /
    • pp.93-96
    • /
    • 2022
  • The boiler tubes of thermal power plants are exposed to harsh environment of high temperature and high pressure, and the deterioration state of materials rapidly increases. In particular, parent material and welds of the materials used are subjected to a temperature change and various constraints, resulting in deformation and its growth, resulting in frequent leakage accidents caused by tube failure. The power plant checks the integrity of boiler tubes through non-destructive testing as it may act as huge costs loss and limitation of power supply during power station shutdown period due to boiler tube leakage. However, the current non-destructive testing is extremely limited in the field to detect micro cracks. In this study, the ability of metal magnetic memory technique to detect flaws of size that are difficult to inspect by the visual or general non-destructive methods was verified in the early stage of their occurrence.