• 제목/요약/키워드: Testing case

Search Result 1,692, Processing Time 0.033 seconds

A Case of Short-chain Acyl-CoA Dehydrogenase Deficiency Detected by Newborn Screening

  • Park, Kyungwon;Ko, Jung Min;Jung, Goun;Lee, Hee Chul;Yoon, So Young;Ko, Sun Young;Lee, Yeon Kyung;Shin, Son Moon;Park, Sung Won
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.15 no.1
    • /
    • pp.40-43
    • /
    • 2015
  • Short-chain acyl-CoA dehydrogenase (SCAD) deficiency is an autosomal recessive mitochondrial disorder of fatty acid oxidation associated with mutations in the ACADS gene. While patients diagnosed clinically have a variable clinical presentation, patients diagnosed by newborn screening are largely asymptomatic. We describe here the case of a 1-year-old male patient who was detected by newborn screening and diagnosed as SCAD deficiency. Spectrometric screening for inborn errors of metabolism at 72hrs after birth showed elevated butyrylcarnitine (C4) level of 1.69 mol/L (normal, <0.83 mol/L), C4/C2 ration of 0.26 (normal, <0.09), C5DC+C60H level of 39 mol/L (normal, <0.28 mol/L), and C5DC/C8 ration of 7.36 (normal, <4.45). The follow-up testing at 18 days of age were performed: liquid chromatography tandem mass spectrometry (LC-MS/MS), urine organic acids, and quantitative acylcarnitine profile. C4 carnitine was elevated as 0.91; urine organic acid analysis showed elevated ethylmalonic acid as 62.87 nmol/molCr (normal, <6.5), methylsuccinate 6.81 nmol/molCr (normal, not detected). Sequence analysis of ACADS revealed a homozygous missense mutation, c.164C>T (p.Pro55Leu). He is growing well and no episodes of seizures or growth retardation had occurred.

RETENTIVE FORCE OF ADJUSTABLE DENTAL IMPRESSION TRAYS WITH DIFFERENT RETENTION FORMS (유지형태에 따른 가변형 치과 인상용 트레이의 유지력에 관한 연구)

  • Song Kie-Bum;Kim Sung-Rok;Park Kwang-Soo;Kim Yu-Lee;Dong Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.1
    • /
    • pp.15-29
    • /
    • 2005
  • Statement of problem. The adjustable dental impression trays were made for being adjusted their width automatically along the width of dental arch. Purpose. The purpose of this study was to investigate the best retentive form of adjustable dental impression tray, and so to make it a more satisfactory product. Material and methods. The eight pairs of adjustable trays were made of ABS(acrylonitrile butadiene styrene) with different distribution of holes and with or without the rim on the border area of them. The experiment was done with the horse-shoe shaped metal plate to pull out the set impression body from the tray, and the tray jig which was made for holding the tray on a lower part of Universal Testing Machine(UTM, Zwick Z020, Zwick Co., Germany). After the impression in the tray was allowed to set four minutes, a tensile force was applied at right angles to the tray which had been previously seated on the jig. The force was applied to measure a maximum retentive force by use of a UTM at a constant strain rate of 100mm per minute. A 2-factor analysis of variance (p<.05) was used to determine whether differences existed among distribution of retentive holes and between rim existing and not. Results. 1 The retentive force of the upper and lower resin tray with 2mm holes on the tray border was highest(25.83/24.98kg). (p<.05) 2. As the tray had more retentive holes, it was less retentive. 3. There was no significant difference in the retentive force of the varied hole intervals in the case of distributing all the area. (p>.05) 4. The rimless trays were more retentive generally, than the rimmed trays except 2 case: upper tray group-all area / 2 mm, intervals and lower tray group-margin only / 2 mm, intervals.(p<.05) 5. Most of the adjustable trays were showed higher retentive force than perforated metal tray except the lower group that perforated on the all area at intervals of 2 mm.

Unsteady 2-D flow field characteristics for perforated plates with a splitter

  • Yaragal, Subhash C.
    • Wind and Structures
    • /
    • v.7 no.5
    • /
    • pp.317-332
    • /
    • 2004
  • Wind tunnel experiments were conducted under highly turbulent and disturbed flow conditions over a solid/perforated plate with a long splitter plate in its plane of symmetry. The effect of varied level of perforation of the normal plate on fluctuating velocities and fluctuating pressures measured across and along the separation bubble was studied. The different perforation levels of the normal plate; that is 0%, 10%, 20%, 30%, 40% and 50% are studied. The Reynolds number based on step height was varied from $4{\times}10^3$ to $1.2{\times}10^4$. The shape and size of the bubble vary with different perforation level of the normal plate that is to say the bubble is reduced both in height and length up to 30% perforation level. For higher perforation of the normal plate, bubble is completely swept out. The peak turbulence value occurs around 0.7 to 0.8 times the reattachment length. The turbulence intensity values are highest for the case of solid normal plate (bleed air is absent) and are lowest for the case of 50% perforation of the normal plate (bleed air is maximum in the present study). From the analysis of data it is observed that $\sqrt{\overline{u^{{\prime}2}}}/(\sqrt{\overline{u^{{\prime}2}}})_{max}$, (the ratio of RMS velocity fluctuation to maximum RMS velocity fluctuation), is uniquely related with dimensionless distance y/Y', (the ratio of distance normal to splitter plate to the distance where RMS velocity fluctuation is half its maximum value) for all the perforated normal plates. It is interesting to note that for 50% perforation of the normal plate, the RMS pressure fluctuation in the flow field gets reduced to around 60% as compared to that for solid normal plate. Analysis of the results show that the ratio [$C^{\prime}_p$ max/$-C_{pb}(1-{\eta})$], where $C^{\prime}_p$ max is the maximum coefficient of fluctuating pressure, $C_{pb}$ is the coefficient of base pressure and ${\eta}$ is the perforation level (ratio of open to total area), for surface RMS pressure fluctuation levels seems to be constant and has value of about 0.22. Similar analysis show that the ratio $[C^{\prime}_p$ max/$-C_{pb}(1-{\eta})]$ for flow field RMS pressure fluctuation levels seems to be constant and has a value of about 0.32.

Reduced-scale Model Experiment for Examination of Natural Vent and Fire Curtain Effects in Fire of Theater Stage (공연장 무대부 화재 시 자연배출구 및 방화막 영향 검토를 위한 축소모형 실험)

  • Baek, Seon A;Yang, Ji Hyun;Jeong, Chan Seok;Lee, Chi Young;Kim, Duncan
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.41-49
    • /
    • 2019
  • In the present experimental study, based on a real-scale theater, a 1/14 reduced-scale model was constructed, and the effects of natural vent and fire curtain in fire of a theater stage were investigated. The case without fire curtain under the opened natural vent showed lower temperatures in the stage, whereas the case with fire curtain under the opened natural vent showed lower temperatures in the auditorium. On the other hand, through analyzing the starting time of the temperature rise at the point near the proscenium opening in the auditorium, it was found that the opened natural vent condition can delay the starting time of smoke spread from the stage to the auditorium and suppress the temperature rise in the auditorium. Under the present experimental conditions, the fire curtain installation did not affect significantly the velocity and mass flow rate of the outflow through the natural vent of the stage, which might be due to openings in the stage. The present results can be used to examine the effects of natural vent and fire curtain in a real-scale fire of a theater and to check the accuracy of the numerical simulation code.

Preliminary study on absorption characteristic of a human body according to the amount of clothing worn for developing standard test dummy (표준더미 개발을 위한 착의량에 따른 인체의 흡음특성 기초연구)

  • Kim, Yong-Hee;Lee, Sung-Chan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.36 no.4
    • /
    • pp.254-260
    • /
    • 2017
  • The purpose of this study is to evaluate the sound absorption characteristics of a human body according to the amount of clothing worn by using reverberation method measurement method for developing standard test dummy, which can be used for testing absorption of occupied audience chair. Test method was based on the previous study (Conti et al., 2004), each experiment is conducted in the reverberation room and a subject wearing clothes is standing in that chamber. In this experiment, the sound absorption area of each frequency band according to the wearing of various material clothing was measured. As a result of measurements, the average sound absorption area of the whole frequency band was $0.25m^2-0.48m^2$ in case of a subject not wearing outer clothes, and $0.38m^2-0.98m^2$ in case of wearing of outerwear. Polyester tops by showing the maximum value, the highest characteristics in the 800 Hz to 1 kHz band among the rest of fiber materials. The outer jacket made of the wool and cotton materials show a higher absorption area as the frequency increases to the higher frequency band. The change of the sound absorption area according to the clothing amount was divided by the thermal resistance (clo) of the worn clothes and the weight per body surface area.

Experimental investigation on flexural behaviour of HSS stud connected steel-concrete composite girders

  • Prakash, Amar;Anandavalli, N.;Madheswaran, C.K.;Lakshmanan, N.
    • Steel and Composite Structures
    • /
    • v.13 no.3
    • /
    • pp.239-258
    • /
    • 2012
  • In this paper, experimental investigations on high strength steel (HSS) stud connected steel-concrete composite (SCC) girders to understand the effect of shear connector density on their flexural behaviour is presented. SCC girder specimens were designed for three different shear capacities (100%, 85%, and 70%), by varying the number of stud connectors in the shear span. Three SCC girder specimens were tested under monotonic/quasi-static loading, while three similar girder specimens were subjected to non-reversal cyclic loading under simply supported end conditions. Details of casting the specimens, experimental set-up, and method of testing, instrumentation for the measurement of deflection, interface-slip and strain are discussed. It is found that SCC girder specimen designed for full shear capacity exhibits interface slip for loads beyond 25% of the ultimate load capacity. Specimens with lesser degree of shear connection show lower values of load at initiation of slip. Very good ductility is exhibited by all the HSS stud connected SCC girder specimens. It is observed that the ultimate moment of resistance as well as ductility gets reduced for HSS stud connected SCC girder with reduction in stud shear connector density. Efficiency factor indicating the effectiveness of high strength stud connectors in resisting interface forces is estimated to be 0.8 from the analysis. Failure mode is primarily flexure with fracturing of stud connectors and characterised by flexural cracking and crushing of concrete at top in the pure bending region. Local buckling in the top flange of steel beam was also observed at the loads near to failure, which is influenced by spacing of studs and top flange thickness of rolled steel section. One of the recommendations is that the ultimate load capacity can be limited to 1.5 times the plastic moment capacity of the section such that the post peak load reduction is kept within limits. Load-deflection behaviour for monotonic tests compared well with the envelope of load-deflection curves for cyclic tests. It is concluded from the experimental investigations that use of HSS studs will reduce their numbers for given loading, which is advantageous in case of long spans. Buckling of top flange of rolled section is observed at failure stage. Provision of lips in the top flange is suggested to avoid this buckling. This is possible in case of longer spans, where normally built-up sections are used.

기도와 찬송이 통증과 불안, 외로움, 안녕감에 미치는 영향

  • Kim Su-Ho;Kim Sin-Su;Kim Jae-Song;Park Hui-Myeong;O Seung-Hun;Won Ju-Hui;Lee Seong-Ok;Lee Chae-Yeong
    • Korean Journal of Hospice Care
    • /
    • v.5 no.1
    • /
    • pp.74-81
    • /
    • 2005
  • Purpose: The purpose of this study is to help apply spiritual care in clinics by testing whether spiritual support like prayer and praise, which is appled on a patient who has been cared for by Facility Hospice can have an effect on their physical pain, emotional anxietv, loneliness and well being. Method: This research was done on a subject patient who had been hospitalized in Saemmul from Jan, 2002 to June, 2003, and who could easily communicate. Questionnaire of quality of life, they had this test from the date of admission into the hospital 1week, 3week, 5week later. The Target was 182 people for the hospital data, 124 people after one week, 84 people after 3 weeks and 54 people after for 5 weeks later. For statistics, SPSS for Window(SPSS inc. ver.10), student T-test and one way ANOVA were used. The interrelation between pray and pain was analyzed by the "Pearson correlation". In case where the P-value was below 0.05, we concluded it had statistical-value. Results: When we compared both the party which had a low degree of peace by prayer and praise and the B party which had the highest degree, B party had an increasing tendency for less anxiety and loneliness and more well-being. Each of the data 0, 1, 3 and 5 week showed visible difference between both parties. Conclusion: First, in case that a late cancer patient is hospitalized, the difference for tranquility and pain control by prayer and praise is not noticeable. While, 1 and 3 weeks later, the difference is visible, so we concluded the relationship between the cancer patient's spiritual tranquility and physical pain are closely related with each other. Also the patients who are in spiritual peace by prayer and praise can control the pain better than the other patients. Second, because the patient who can feel calm from the data of being admitted into the hospital is mentally calm, both party's difference is noticeable in each period of the 1, 3 and 5th week. Compared with other patients, the object patients who have spiritual tranquility will have less anxiety and loneliness and more tranquility.

  • PDF

An Experimental Study on the Fracture and Shear Bonding Strength of Resin-modified Glass lonomer Cements (Resin-modified glass ionomer cements의 파절 및 저단결합강도에 관한 실험적 연구)

  • Kim, Jae-Gon;Yang, Cheol-Hee;An, Soo-Hyeon;Rho, Yong-Kwan;Baik, Byeong-Ju
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.1
    • /
    • pp.234-248
    • /
    • 1998
  • The purpose of this study was to compare the fracture and shear bonding strength of resin-modified glass ionomer cements with composite resin and conventional glass ionomer cement Three kinds of restorative materials including a composite resin (Z 100), a conventional glass ionomer cement(Fuji II), and resin- modified glass ionomer cements(Fuji II LC, Vitremer, Dyract and Compoglass) were investigated in this study. For measurement of fracture and shear bonding strength, disk samples of the materials were prepared and cylindrical samples of the materials were bonded the flat enamel and dentin surfaces according to manufactuer's instructions. All specimen were determinated by using an Instron testing machine with a crosshead speed of 1 mm/min. Then, each treated enamel and dentin surface was observed by SEM. The following results were obtained. 1. The bi-axial flexural strength of Z 100 was highest, and Fuji n LC, Vitremer, Dyract and Compoglass were significantly higher than Fuji n (P<0.05). 2. The shear bonding strength of Z 100 on the enamel and dentin surface was higher than other experimental groups except Fuji II LC(P<0.05). Fuji II LC was significantly higher than Fuji II (P<0.05), but in the case of Vitremer, Dyract and Compoglass were similar to Fuji II (P>0.05). 3. The shear bonding strength of Z 100 and Fuji II LC on the enamel surface were highly increased as compared with dentin surface (P<0.05), but in the case of Fuji II, Vitremer, Dyract and Compoglass were not different between enamel and dentin(P>0.05). 4. In the Z 100 and Fuji II LC, obvious etched enamel surface and exposed dentinal tubules according to remove of smear layer and smear plug were observed.

  • PDF

A monitoring for the establishment of microbial limit of herbal medicine(I) (한약재의 미생물허용한도 설정을 위한 모니터링(I))

  • Lee, Ju-Hyun;Jeon, Won-Kyung;Go, Byoung-Seob;Chun, Jin-Mi;Lee, A-Yeong;Kim, Ho-Gyoung
    • Korean Journal of Oriental Medicine
    • /
    • v.12 no.1
    • /
    • pp.49-57
    • /
    • 2006
  • Objectives : This study has attempted to establish an organized system for the microbiological quality of raw materials which are important factors in preparing the standard for microbial limits. Methods : This study has first set up microbial contamination limit test. total aerobic microbial count and total fungi count, int accordance with testing method of the Korea Pharmacopeia 8th edition in order to establish an inspection standard for microbial contamination. Results : The microbial contamination of 18 items that are highly prone to contamination by three regions(Seoul, Daejeon, Gyeongsangbuk-do), As a result, Morus alba Linne and Rehmannia glutimosa Liboschitz var. purpurea Makino showed as high contaminated by WHO's Microbial Contamination Limit standard. In case of Yukjin medicine in the Theory of Herb Medicinal Properties, total bacterial contamination rate showed as 17.7%, total fungal contamination rate showed as 41.2% and total aerobic mircobial count and total fungi count on Ephedra sinica Stapf. Pinellia ternate Breitenbach, Evodia officinalis Dode showed as high measured. The microbial conatmination rate materials which make up Yukmijihwanghwan were mostly high therefore the total aerobic microbial count was measured as high in case of Yukmijihwanghwan, the characteristics about microbial contamination strain is to be researched. Conclusions : By combining the basic data and experimental results related to microbial contamination of herb medicine, the most ideal storage standards for herb medicine has been attempted to be presented.

  • PDF

Impact Analysis for Transit Oriented Street Design (A Case Study for Kangnam Street in Seoul) (대중교통우선가로제 시행방안 및 기대효과 분석 (강남대로 중앙버스전용차로 도입을 중심으로))

  • 황기연;이조영
    • Journal of Korean Society of Transportation
    • /
    • v.21 no.3
    • /
    • pp.47-56
    • /
    • 2003
  • Considering the high density developments along the major traffic corridors in Seoul, transit-oriented street designs will be a very effective to control traffic congestion along the corridors. For testing the effectiveness, we selected. for our case study, Kangnam Street, which is one of the most highly developed corridors in Seoul The traffic study on Kangnam street in 2000 shows that the daily average bus speed is 11.73km/h, which is 5km/h lower than the auto speed. The Central Bus Lane system was applied on the Kangnam street to test impact on bus speed as well as auto speed. Simulation results show that with Central Bus Lane have been improved the travel speeds of bus as well as auto on Kangnam street from 14.4km/hr to 35.0km/hr and from 25.1km/hr to 26.1km/hr, respectively. The bus market share increases about 6-8 percentages. Especially, 13.4% of bus users are increased for long-distance trips.