• Title/Summary/Keyword: Testing Temperature

Search Result 1,536, Processing Time 0.039 seconds

Development of an Effective Method for Testing Resistance to Black Spot of Radish Caused by Alternaria brassicicola (Alternaria brassicicola에 의한 무 검은무늬병에 대한 효율적인 저항성 검정법 개발)

  • Lee, Ji Hyun;Jang, Kyoung Soo;Choi, Yong Ho;Kim, Hun;Choi, Gyung Ja
    • Horticultural Science & Technology
    • /
    • v.35 no.2
    • /
    • pp.210-219
    • /
    • 2017
  • This study was conducted to establish an efficient screening method for radish (Raphanus sativus) cultivars that are resistant to black spot, which is caused by Alternaria brassicicola. Seven A. brassicicola isolates were selected and investigated for their ability to produce spores and pathogenicity. Of these isolates, A. brassicicola KACC 40036 and 43923 produced abundant spores in V-8 juice agar medium and showed pathogenicity and strong virulence on radish seedlings. We examined the resistance of 61 commercial cultivars of radish to A. brassicicola KACC40036, and found that there are no highly resistant radish cultivars; however, some cultivars, such as 'Geumbong' and 'Searom', showed weak resistance to A. brassicicola. For further study, we selected four radish cultivars that showed different disease responses to A. brassicicola KACC40036. According to the growth stage of the radish seedlings, inoculum concentration, and incubation temperature of radish, development of black spot on four cultivars has been investigated. The results showed that younger seedlings were more sensitive to A. brassicicola than older seedlings, and the disease severity depended on the concentration of the spore suspension. The disease severity of plants incubated in humidity chamber at $25^{\circ}C$ was greater than that of plants grown at $20^{\circ}C$ or $30^{\circ}C$. Taken together, we suggest the following method for screening for radish plants that are resistant to A. brassicicola: 1) inoculate 16-day-old radish seedlings with an A. brassicicola spore suspension ($2.0{\times}10^5spores{\cdot}mL^{-1}$) using the spray method, 2) incubate the inoculated plants in a humidity chamber at $25^{\circ}C$ for 24 h and then transfer the plants to a growth chamber at $25^{\circ}C$ with 80% relative humidity under a 12 h light/dark cycle, and 3) assess the disease severity of the plants two days after inoculation.

Development of Evaluation Method for Jointed Concrete Pavement with FWD and Finite Element Analysis (FWD와 유한요소해석을 이용한 줄눈콘크리트포장 평가법 개발)

  • Yun, Kyong-Ku;Lee, Joo-Hyung;Choi, Seong-Yong
    • International Journal of Highway Engineering
    • /
    • v.1 no.1
    • /
    • pp.107-119
    • /
    • 1999
  • The joints in the jointed concrete pavement provide a control against transverse or longitudinal cracking at slab, which may be caused by temperature or moisture variation during or after hydration. Without control of cracking, random cracks cause more serious distresses and result in structural or functional failure of pavement system. However, joints nay cause distresses due to its inherent weakness in structural integrity. Thus, the evaluation at joint is very important. and the joint-related distresses should be evaluated reasonably for economic rehabilitation. The purpose of this paper was to develop an evaluation system at joints of jointed concrete pavement using finite element analysis program, ILLI-SLAB, and nondestructive testing device. FWD. To develop an evaluation system for JCP, a sensitivity analysis was performed using ILLI-SLAB program with a selected variables which might affect fairly to on the performance of transverse joints. The most significant variables were selected from precise analysis. An evaluation charts were made for jointed concrete pavement by adopting the field FWD data. It was concluded that the variables which most significantly affect to pavement deflections are the modulus of subgrade reaction(K) and the modulus of dowel/concrete interaction(G), and limiting criteria on the performance of joints at JCP are 300pci. 500,000 lb/in. respectively. Using these variables and FWD test, a charts of load transfer ratio versus surface deflection at joints were made in order to evaluate the performance of JCP. Practically, Chungbu highway was evaluated by these evaluation charts and FWD field data for jointed concrete pavement. For Chungbu highway, only one joint showed smaller value than limiting criterion of the modulus of dowel/concrete interaction(G). The rest joints showed larger values than limiting criteria of the modulus of subgrade reaction(K) and the modulus of dowel/concrete interaction(G).

  • PDF

A STUDY OF ADDITIONAL VIBRATION EFFECT ON DENTIN BOND STRENGTH (진동이 상아질 결합력에 미치는 영향에 관한 연구)

  • Lee, Jin;Kim, Jung-Wook;Lee, Sang-Hoon;Kim, Chong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.4
    • /
    • pp.632-640
    • /
    • 2002
  • The objective of the study was to apply the vibration technique to reduce the viscosity of bonding adhesives and thereby compare the bond strength and resin penetration into dentinal tubules achieved with those gained using the conventional technique. Eighty-eight noncarious extracted human permanent molar teeth were sectioned to remove the coronal enamel and were embedded in 1-inch PVC pipe with acrylic resin. The occlusal surfaces were placed so that the tooth and the embedding medium were at the same level to form one flat surface, and the samples were subsequently polished with silicon carbide abrasive papers. The samples were randomly assigned to 4 groups(n=22). On Group 1 and 2, Single Bond(3M-ESPE, St. Paul, USA) was used, and on Group 3 and 4, One-Step(Bisco Inc., Schaumburg, USA) was used, and each was applied according to its manufacturer's instructions. For Group 2 and Group 4, vibration was applied with ultrasonic scaler for 10 seconds, and the adhesive was light-cured for 10 seconds. Resin composite was condensed on to the prepared surface in two increments using a mold kit(Ultradent Products Inc., USA) and each was light-cured for 40 seconds. After 24 hours in tap water at room temperature the specimens were thermocycled, and shear bond strengths were measured with a universal testing machine(Instron 4465, Canton, USA). To investigate infiltration patterns of the adhesive materials, the surface of specimen was examined with scanning electron microscope. The results were as follows. 1. The shear bond strengths of vibration groups(Group 2, Group 4) were significantly greater than those of the non-vibration groups(Group 1, Group 3)(p<0.05). 2. The shear bond strengths of Single Bond and One-Step were not significantly different (p>0.05). 3. The vibration groups showed greater number of resin tags in tubules and lateral branches under SEM.

  • PDF

A Study on Comparison of Outdoor Wind Pressure Performance According to Outdoor Exposure and Acceleration Deterioration Methods of Structural Sealants Applied to Curtain Wall (커튼월에 적용된 구조용 실링재의 옥외폭로와 실내복합열화 처리방법에 따른 내풍압성능 비교연구)

  • Jang, Pil Sung;Hong, Soon Gu;Kim, Sung Rae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.9
    • /
    • pp.279-287
    • /
    • 2018
  • Sealants are an important element of modern architecture and serve as a building protection against weathering by providing barriers against ingress of moisture, air, and other materials. Exposure to a variety of environments often reduces lifespan due to changes in physical, chemical and mechanical characteristics, and UV, humidity, and temperature expansion are important issues that are directly related to durability. In this study, a combined deterioration test chamber was developed to simulate the environment of the open air as an instrument for verifying the durability of structural sealing materials indoors. In order to replicate special weather conditions, such as yellow dust, acid rain, and contamination by microorganisms, it was deemed impossible to replicate the outdoor environment by 100 %, and the results of the results of the results of the external exposure test of the structural sealant and the combined deterioration testing device. As a result of the displacement test of the outdoor exposure test, it was determined that the sealant was breaking apart and that it would be smooth, and the displacement would be up to three times greater than the initial material value of 1 year. The displacement test results of the combined deterioration test device show the tendency to deteriorate, decreasing the elasticity and tensile characteristics. In the case of denatured silicon, the current 400 cycles have been completed to confirm 12 months of degradation of the external exposure. The deformation of the test specimen cannot be verified with the naked eye, so it is considered that the conditions of the specimen are more stable than the silicon sealant. As a result of the outdoor exposure test, if the combined deterioration test device is structured and proposed in the relevant guidance or specification, the anticipated lifespan of 12 months in the actual use environment can be verified indoors and below 3 months later, economically.

Control of Bakanae Disease of Rice by Seed Soaking into the Mixed Solution of Procholraz and Fludioxnil (Prochlornz와 fludioxonil 혼용침지소독에 의한 벼 키다리병 방제)

  • Park, Woo-Sik;Choi, Hyo-Won;Han, Seong-Suk;Shin, Dong-Beum;Shim, Hyeong-Kwon;Jung, En-Seon;Lee, Se-Weon;Lim, Chun-Keun;Lee, Yong-Hwan
    • Research in Plant Disease
    • /
    • v.15 no.2
    • /
    • pp.94-100
    • /
    • 2009
  • These experiments were conducted to improve the effect of seed disinfection on rice seed severely infected Bakanae disease by seed soaking into mixed solution of prochloraz EC and fludioxonil FS. We investigated the effects of various concentrations of two fungicides mixed solution on spore germination and mycelial growth of Fusarium fujikuroi. Mycelial growth was inhibited 100% at $10{\mu}g$/ml of prochloraz and 33.3% at $80{\mu}g$/ml of fludioxonil. Spore germination was inhibited 81.4% at $40{\mu}g$/ml of prochloraz. Interestingly, mixed solution of $5{\mu}g$/ml or $10{\mu}g$/ml of each fungicide inhibitied 100% of mycelial growoth and 99.2% of spore germination, respectively. Severely infected rice seeds soaked into mixed solution composed of $125{\mu}l$/ml of prochloraz and $50{\mu}l$/ml of fludioxonil showed 2.1% of disease symptoms compared to 20.4% of prochloraz $125{\mu}l$/ml, but higher concentrations of prochloraz decreased the seedling stand rate. When the seed soaking time was longer and temperature was higher, control effect on Bakanae disease was improved, but seedling stand was lower about 80% over $35^{\circ}C$.

Combination Culture of Rotifer Brachionus rotundiformis and Copepod Apocylops sp. (로티퍼 Brachionus rotundiformis와 코페포다 Apocyclops sp.의 혼합 배양)

  • Jung, Min-Min;Rho, Sum
    • Journal of Aquaculture
    • /
    • v.11 no.4
    • /
    • pp.449-455
    • /
    • 1998
  • The small size food organism(under the size 150${\mu}m$) is needed as food for early stage of marine fish larvae of small mouse (e.g the group of grouper). This study was investigated to develop a method for copepod Apocyclops sp. culture in combination with the rotifer B. rachionus for stable culture of copepod species and harvest of various size food organisms. The culture conditions as temperature, salinity, culture volume, photo period, culture preiod and observation interval were 25${\circ}C$, 22ppt, 40ml, all dark except to observation time, 16 days and every two day during the experimental period, respectively. The Tetraselmis suecica was used as the food for the two testing orgtanisms. After every two day counting, theses two organisms were transferred to fresh culture tanks with Tetraselmis suecica of $7{\times}10^5$cells/ml. In the mixed culture of B. rotundiformis and A. sp., growth of rotifer was suppressed by mixed culture with A. sp. whereas the growth of copepod Apocyclops was promoted in the mixed culture with rotifer B. rotundiformis (the maximum density was 22 individuals/ml through the 16 culture days). Moreover, the number of copepod nauplius were promoted about 2 times in the mixed culture compared to the numbers in single species culture. With this combination culture, the havested two food organisms of variable sizes. This size variation of food organisms was useful tools for larval rearing of small mouse marine fish larvae and next step food organism size of post hatched larvae.

  • PDF

Optimum Stocking Density of 3-year-old Pacific Abalone, Haliotis discus hannai Reared in Net Cage Culture (3년산 북방전복, Haliotis discus hannai의 해상가두리 양성 시 적정 수용밀도)

  • Lee, Si-Woo;Kim, Byeong-Hak;Kim, Tae-Ik;Son, Maeng-Hyun
    • The Korean Journal of Malacology
    • /
    • v.31 no.2
    • /
    • pp.93-101
    • /
    • 2015
  • The effects of different stocking densities on the growth and survival rate of the 3-year-old pacific abalone, Haliotis dicus hannai were investigated in marine net cage for a year. Stocking densities in net cage ($2.4{\times}1.2m$) was set 15, 30, 45 and 60 percentage (= per)/sq m (square meter, $m^2$) with share to cross-sectional area per shelter. The water temperature during the testing period was $8.2^{\circ}C-22.1^{\circ}C$, and salinity is $33.5{\pm}0.6psu$, and dissolved oxygen is $7.87{\pm}0.86mg/L$. In the shell length (initial size : $71.50{\pm}2.28mm$) growth and shell breadth (initial size : $46.43{\pm}2.28mm$) of the test abalones, the absolute growth rate (ARG), daily growth rate (DGR) and specific growth rates (SGR) of the 15 per/sq m and 30 per/sq m were higher than those of 45 per/sq m and 60 per/sq m density group (P < 0.05). Also in the weight (initial weight : $35.7{\pm}8.1g$), it showed the same results. In survival rates, it were that 15 per/sq m and 30 per/sq m is significantly higher than 45 per/sq m and 60 per/sq m. Therefore, it was that the 15 per/sq m is optimized stocking density in marine net cages about the 3-year-old pacific abalone over 70 mm size. The result shown that total cross-sectional area under the shelter is based on 15 per/sq m ($2.4{\times}2.4m$, 354 number in a net cage) is suitable for fast growth and survival. But if the economy consider, optimized stocking density would be appropriate to accept 30 per/sq m ($2.4{\times}2.4m$, 710 number in a net cage).

An Experimental Study on Establishing Criteria of Gripping Work in Construction Site (건설 현장 악력 작업안전 기준 설정에 관한 실험적 연구)

  • 손기상;이인홍;최만진;안병준
    • Journal of the Korean Society of Safety
    • /
    • v.10 no.3
    • /
    • pp.81-95
    • /
    • 1995
  • Now, safety assurance in construction sites should be accomplished by its own organization rather than control of the code or government. It is believed that the safety assurance can be considerably improved by a lecture or an education using the existing theories or literatures up to now, but it is thought that fundamental safety assurance we not able to be accomplished without developing safety devices '||'&'||' equipment or taking fundamental measures, based on the result analyzed from workers behaviors. There are various behaviors of the workers showed in construction site, but only tests for hammerusing works such as form, re-bar, stone workers directly related to the grip strength are mainly performed, investigated and measured here for the study. The above works are similar to power grip, 7th picture on seven items which are categorized for hand grip types(Ammermin 1956 ; Jones ; Kobrick 1958). Measurements of grip strength are commonly taken in anthropometric surveys. They are easy to administer but unfortunately it is rather dubious whether they yield any data that are of interest to the engineer. Very fewer controls of tools are grasped and squeesed studies showed very little overall correlation between grip strength and other measures of bodily strength (Laubach, Kromer, and Thordsen 1972), but hammer-using work which is practically progressed in construction site are mainly influenced with grip strength. According to the investigation on work measurement, it is shown that 77% of form worker are using hammer to be related to grip strength. In this study, it is particularly noticed that wearing safety gloves in construction site is required for workers safety but 20% difference between grip strength with safety gloves and without ones are commonly neglected in the site(Fig. 1). Nevertheless, safety operation with consideration of the above 20% difference is not considered in the construction site. Factors of age, kinds of work, working time, with or without safety gloves are in vestigated '||'&'||' collected at the sites for this study. Test, not at each working hour but at 14 : 00 when the almost all of the workers think the most tired, resulting from the questionaires, also when it is shown on the research report has been performed and compared for main kinds of works : form '||'&'||' re-bar work. Tests were performed with both left SE rightand of the workers simultaneously in construction site using Rand Dynamometer(Model 78010, Lafayette Instrument Co., Indiana, U.S.A) by reading grip strength on the gauge while they are pulling, and then by interviewing on their ages, works, experiences and etc., directly. The above tests have been performed for the dates of 15th march-26th May '95 with consideration of site condition. And even if various factors of ambient temperature on the testing date, working condition, individual worker's habit and worker's condition of the previous ate are concerned with the study. Those are considered as constants in this study. Samples are formwork 53, rebar 62, electrician 5, plumber 4, welding 1 from D construction Co., Ltd, ; formwork 12, re-bar 5, electrician 2, from S construction Co., Ltd, , formwork 78, re-bar 18, plumber 31, electrician 13, labor 48, plumber 31, plasterer 15, concrete placer 6, water proof worker 3, maisony 5 from B construction Co., Ltd. As In the previously mentioned, main aspect to be investigated in this study will be from '||'&'||' re-bar work because grip strength will be directly applied to these two kinds of works ; form '||'&'||' re-bar work, eventhough there are total 405 samples taken. It is thought that a frequency of accident occurrence will be mainly two work postures "looking up '||'&'||' looking down" to be mainly sorted, but this factor is not clarified in this study because It will be needed a lot of work more. Tests has been done at possible large scale of horizontally work-extended sites within one hour in order to prevent or decrease errors '||'&'||' discrepancies from time lag of the test. Additionally, the statistical package computer program SPSS PC+has been used for the study.

  • PDF

Development of a High Heat Load Test Facility KoHLT-1 for a Testing of Nuclear Fusion Reactor Components (핵융합로부품 시험을 위한 고열부하 시험시설 KoHLT-1 구축)

  • Bae, Young-Dug;Kim, Suk-Kwon;Lee, Dong-Won;Shin, Hee-Yun;Hong, Bong-Guen
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.4
    • /
    • pp.318-330
    • /
    • 2009
  • A high heat flux test facility using a graphite heating panel was constructed and is presently in operation at Korea Atomic Energy Research Institute, which is called KoHLT-1. Its major purpose is to carry out a thermal cycle test to verify the integrity of a HIP (hot isostatic pressing) bonded Be mockups which were fabricated for developing HIP joining technology to bond different metals, i.e., Be-to-CuCrZr and CuCrZr-to-SS316L, for the ITER (International Thermonuclear Experimental Reactor) first wall. The KoHLT-1 consists of a graphite heating panel, a box-type test chamber with water-cooling jackets, an electrical DC power supply, a water-cooling system, an evacuation system, an He gas system, and some diagnostics, which are equipped in an authorized laboratory with a special ventilation system for the Be treatment. The graphite heater is placed between two mockups, and the gap distance between the heater and the mockup is adjusted to $2{\sim}3\;mm$. We designed and fabricated several graphite heating panels to have various heating areas depending on the tested mockups, and to have the electrical resistances of $0.2{\sim}0.5$ ohms during high temperature operation. The heater is connected to an electrical DC power supply of 100 V/400 A. The heat flux is easily controlled by the pre-programmed control system which consists of a personal computer and a multi function module. The heat fluxes on the two mockups are deduced from the flow rate and the coolant inlet/out temperatures by a calorimetric method. We have carried out the thermal cycle tests of various Be mockups, and the reliability of the KoHLT-1 for long time operation at a high heat flux was verified, and its broad applicability is promising.

A Study on the Effect of Applying Water Seepage Lowering Method Using Swelling Waterstop for Expansion Joint in the Concrete Dam (콘크리트 댐에서 수축이음부의 수팽창성 차수재를 이용한 침투저감 공법 적용효과 연구)

  • Han, Kiseung;Lee, Seungho;Kim, Sanghoon;Kim, Sejin;Pai, Sungjin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.22 no.10
    • /
    • pp.21-29
    • /
    • 2021
  • Most concrete gravity-type dams in and out of the country were constructed by column method to control cracks caused by concrete hydration heat generated during construction, resulting in a certain level of leakage after impoundment through various causes, such as contraction joints and construction joints. However, due to the characteristics of concrete structures that shrink and expand according to temperature, concrete dams have vertical joints and drains to allow penetration. PVC waterproof shows excellent effects in completion of the dam, which however increases the possibility of interfacial failure due to different thermal expansion. Other causes of penetration may include problems with quality control during installation, generation of cracks due to heat of hydration of concrete, waterproofing methods, etc. In the case of Bohyunsan Dam in Yeongcheon, North Gyeongsang Province, the amount of drainage in the gallery was checked and underwater, and it was confirmed that there are many penetrations from drainage holes connected to vertical joints, and that some of the PVC waterproofs are not fully operated. As a new method to prevent penetration through vertical joints, D.S.I.M. (Dam Sealing Innovation Method) developed by World E&C was applied to Bohyunsan Dam and checked the amount of drainage in the gallery. As a result of first testing three most leaking vertical joints, the drain in the gallery was reduced by 87% on the average and then applied to the remaining 13 locations, which showed a 83% reduction effect based on the total drain in the gallery. Summing up these results, it was found that D.S.I.M. preventing water leakage from the upstream face is a valid construction method to reduce the water see-through and penetration quantity seen in downstream faces of concrete dams. If D.S.I.M. is applied to other concrete dams at domestic and abroad, it is expected that it will be very effective to prevent water leakage through vertical joints that are visible from downstream faces.