• Title/Summary/Keyword: Testing Equipment

Search Result 866, Processing Time 0.031 seconds

Field Tests for Accuracy of GNSS-RTK Surveys by ISO 17123-8 Standard (ISO 17123-8 표준에 의한 GNSS-RTK 수신기 정확도 평가)

  • Lee, Hungkyu
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.40 no.4
    • /
    • pp.333-342
    • /
    • 2022
  • This paper has theoretically and practically reviewed the ISO (International Standard Organization) 17123-8 standard not only to raise the appropriateness for introducing performance criteria of GNSS (Global Navigation Satellite Systems) surveying equipment based on RTK (Real-Time Kinematic) accuracy but also to derive its proper test procedure by introducing the international standard. Field experiments have been performed to appreciate the GNSS-RTK accuracy of five selected receivers via the full testing procedure of the ISO standard, which statistically compares the so-called experimental standard deviations with themselves and with the reference accuracy. A series of statistical tests have revealed that the RTK accuracy of the same class receivers is not identical, whereas that of the different classes can be equivalent. Such a result evidences the urgency of adopting an RTK accuracy-based specification of the GNSS equipment to the performance standard, currently referenced to the static observation technique only. It is believed that this transition helps the maximization of a new generation of cost-effective receivers to legal surveying applications. Finally, this study proposes the ISO full test, comparing an experimental standard deviation with its referenced value, for a potential field verification procedure of the new performance standard.

A study on the measurement and processing of medical service experience data - From the perspective of realizing patient-centeredness - (의료서비스 경험데이터의 측정 및 가공에 관한 연구 -환자중심성 실현 관점에서-)

  • Jinho, Ahn;Jungmin, Choi
    • Journal of Service Research and Studies
    • /
    • v.13 no.3
    • /
    • pp.147-159
    • /
    • 2023
  • This study is a study to develop a model for measurement and processing of experience data, which is emerging as a core value in quality management of medical services. In the theoretical background, a literature study was conducted on the importance of experience in medical service, measurement and processing of experience data, and realization of patient-centeredness. Based on these literature and theoretical background research results, operational definitions were performed for the following four research variables, and statistical tests were conducted. Hypothesis 1 is the effect of measuring experience data from the perspective of three factors on persona modeling, Hypothesis 2 is the effect of persona modeling on service blueprint visualization, Hypothesis 3 is the effect of service blueprint visualization on realization of patient-centeredness, and Hypothesis 4 is persona modeling This is the effect that modeling has on the realization of patient-centeredness. After data-based testing of factor analysis, reliability analysis, and correlation analysis, all four hypotheses were adopted as a result of verification using regression analysis. In conclusion, in an era where it is difficult to recognize the value of having only good medical staff and medical equipment in hospitals, it was possible to grasp the meaning that what kind of medical service experience is continuously obtained is more important to patients than the effectiveness of medical staff and medical equipment. In the era of the service economy, the core of hospital service competitiveness is providing attractive experiences, which is the real strength of hospitals, so the measurement and processing of experience data, which is the subject of this study, will have an important meaning in realizing patient-centeredness and realizing smart hospitals.

Structural Performance Evaluation of Anchors for Power Equipment Electrical Cabinets Considering On-Site Installation Conditions (현장 설치 조건을 고려한 발전설비 전기 캐비닛 정착부 앵커의 구조성능 평가)

  • Lee, Sang-Moon;Jung, Woo-Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.6
    • /
    • pp.709-719
    • /
    • 2023
  • In general, most of the electrical equipment responsible for control within power plants is housed in self-standing cabinets. These cabinets are typically fixed to a slab using post-installed anchors. Although the fixation method of using post-installed anchors provides stability, there is a risk of conductor failure due to external forces, including moments. However, the performance assessment of current anchors is only evaluated through uniaxial material tests. Therefore, the primary purpose of this study is to compare the static performance of post-installed anchors, considering on-site installation conditions, with their performance in material tests and to analyze the behavioral characteristics of the anchors. While conducting experiments using actual cabinets would be ideal, practical and spatial constraints make this approach difficult. As an alternative, experiments were conducted using a test specimen consisting of a steel column and a support. As a result, the pull-out performance of anchors reflecting on-site installation conditions was measured to be about 10% higher than that observed in material tests. The trends in load reduction and the point of maximum performance for the anchors also differed. To verify the reliability of the experimental study, a 3D FEM analysis was performed, which will provide predictive information on the loads transferred to the post-installed anchors for structural performance evaluations of electrical cabinets using shaking table test in the future.

A Study on Microbial Community Diversity and Antibiotic Resistance in Public Waters in Gwangju (광주지역 공공수역의 미생물 군집 다양성 및 항생제 내성에 관한 연구)

  • Sun-Jung Kim;Ji-Young Park;Seung-Ho Kim;Min-Hwa Lim;Ji-Yong Yu;Kyu-Sung Han;Se-Il Park;Gwangyeob Seo;Gwangwoon Cho
    • Journal of Environmental Health Sciences
    • /
    • v.50 no.2
    • /
    • pp.93-101
    • /
    • 2024
  • Background: As pollutants caused by non-point sources flow into rivers, river water quality monitoring for fecal pollution is becoming increasingly important. Objectives: This study was conducted to investigate the distribution of microbial communities in the Yeongsangang River water system and sewage treatment plants in Gwangju and to evaluate their antibiotic resistance. Methods: In the experiment, samples were distributed to five selective media at each point and then cultured for 18 to 24 hours. When bacteria were observed, they were sub-cultured by size and shape and identified using MALDI-TOF MS equipment. When identification was completed, 17 types of antibiotic susceptibility tests were performed using VITEK II equipment, focusing on gram-negative dominant species among the identified strains. Results: During the study period, a total of 266 strains were isolated from 39 samples. Gram-positive bacteria were 37 strains in four genera, or 13.9% of the total, and Gram-negative bacteria were 229 strains in 23 genera, or 86.1% of the total. Antibiotic susceptibility testing of 23 strains, the major dominant species, showed that one strain (4.3%) was resistant to only one antibiotic, and two strains (8.7%) were 100% susceptible to the 17 antibiotics tested. The other 20 strains (87.0%) were multidrug resistant bacteria resistant to two or more antibiotics. There were various types of multidrug resistance. Among them, penicillin and cephalosporin series showed the highest resistance. Conclusions: Based on the results of this study, it was found that the bacterial community structure changed according to regional and environmental factors, and it was judged that continuous research such as genetic analysis of antibiotic-resistant bacteria present in natural rivers is necessary.

The Study on the Marine Eco-toxicity and Environmental Risk of Treated Discharge Water from Ballast Water Management System using Plasma and MPUV (Plasma와 MPUV를 이용한 평형수관리장치의 배출수에 대한 해양생태독성 및 해양환경위해성에 관한 연구)

  • Shon, M.B.;Son, M.H;Lee, J.;Lee, S.U.;Lee, J.D.;Moon, C.H.;Kim, Y.S.
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.15 no.4
    • /
    • pp.281-291
    • /
    • 2012
  • In this study, WET (whole effluent toxicity) test with Skeletonema costatum, Tigriopus japonicus and Paralichthys olivaceus and ERA (environmental risk assessment) were conducted to assess the unacceptable effect on marine ecosystem by emitting the treated discharge water from 'ARA Plasma BWTS' BWMS (ballast water management system) using filtration, Plasma and MPUV module. 34 psu treated discharge water from ARA Plasma BWTS shown slight chronic toxicity effect on the P. olivaceus ($7d-LC_{50}{\Rightarrow}100.00%$ treated discharge water, $7d-LC_{25}{\Rightarrow}85.15%$ treated discharge water). Bromobenzene, chlorobenzene and 4-chlorotoluene in 34 psu treated discharge water from ARA Plasma BWTS were higher than in the background original content of seawater. The PECs (predictive environmental concentrations) of bromobenzene, chlorobenzene and 4-chlorotoluene calculated by MAMPEC (marine antifoulant model to predict environmental concentrations) program (ver. 3.0) were 3.34E-03, 2.10E-03 and 1.73E-03 ${\mu}g\;L^{-1}$, respectively and PNECs (predicted no effect concentrations) of them were 1.6, 0.5 and 1.9 ${\mu}g\;L^{-1}$. The PEC/PNEC ratio of bromobenzene, chlorobenzene and 4-chlorotoluene did not exceed one and 3 substances did not consider as persistence, bioaccumulative and toxic. Therefore, it was suggested that treated discharge water from ARA Plasma BWTS did not pose unacceptable effect on marine ecosystem.

Degradation Evaluation of High Pressure Reactor Vessel in field Using Electrical Resistivity Method (전기비저항법을 이용한 고압반응기 열화도 현장평가)

  • Park, Jong-Seo;Baek, Un-Bong;Nahm, Seung-Hoon;Han, Sang-In
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.5
    • /
    • pp.377-383
    • /
    • 2005
  • Because explosive fluid is used at high temperature or under high pressure in petrochemistry and refined oil equipment, the interest about safety of equipments is intensive. Specially, the safety of high pressure reactor vessel is required among them. The material selected in this study is 2.25Cr-1Mo steel that is widely used for high pressure reactor vessel material of petrochemical plant. Eight kinds of artificially aged specimens were prepared by differing from aging periods under three different temperatures. The material was iso-thermally heat treated at higher temperatures than $391^{\circ}C$ that is the operating temperature of high pressure reactor vessel. Vickers hardness properties and electrical resistivity properties about artificially aged material as well as un-aged material were measured, and master curves were made out from the correlation with larson-Miller parameter. And electrical resistivity properties as well as Victors hardness properties measured at high pressure reactor vessel of the field were compared with master curves made out in a laboratory. Degradation evaluation possibility in the field of high pressure reactor vessel by using electrical resistivity method was examined. Electrical resistivity property measured in the field is similar with that of artificially aged material in similar aging level.

Study on the Micro Crack Detection in Joints by Using Ultrasound Infrared Thermography (초음파 적외선 열화상을 이용한 접합부의 미세균열 검출 연구)

  • Park, Hee-Sang;Choi, Man-Yong;Park, Jeong-Hak;Lee, Seung-Seok;Huh, Yong-Hak;Lee, Bo-Young;Kim, Jae-Seong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.2
    • /
    • pp.162-169
    • /
    • 2012
  • This study detected SCC defects of dissimilar metal welded(STS304 and SA106 Gr. b) pipes using the ultrasonic infrared thermography method and the lock-in image treatment method among infrared thermography method. The infrared excitement equipment has 250 Watt of output and 20 kHz of frequency. By using the ultrasound infrared thermography method, the internal defects of dissimilar metal weld joints of pipes used at nuclear power plants could get detected. By an actual PT test, it was observed that the cracks inside the pipe existed not as a single crack but rather as a multiple cracks within a certain area and generated a hot spot image of a broad area on the thermography image. In addition, UT technology could not easily defects detected by the width of $10\;{\mu}m$ fine hair cracks. but, ultrasound infrared thermography technique was defect detected.

Dynamic Soil Properties of Frozen and Unfrozen Soils from Terra Nova Bay in Eastern Antarctica (동남극 테라노바만 흙 시료의 동결 및 비동결 상태에서의 동적특성 평가)

  • Kim, Jae-Hyun;Kwon, Yeong-Man;Park, Keunbo;Kim, YoungSeok;Kim, Dong-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.3
    • /
    • pp.37-47
    • /
    • 2017
  • The geotechnical characteristics of frozen ground is one of the key design issues for the construction of infrastructure in cold region. In this study, the dynamic properties (shear modulus and damping ratio) of frozen and unfrozen soils sampled from Terra Nova Bay located in eastern Antarctica, where Jang Bogo station was built, were investigated using Stokoe-type resonant column test (RC). In order to freeze the reconstituted soil specimen, the RC testing equipment was modified by adding a cooling system. A series of resonant column tests were performed in frozen and unfrozen soils with various soil densities and temperatures. The shear modulus (G) and damping ratio (D) of soil frozen at $-7^{\circ}C$ were compared with those of unfrozen soil. In addition, the effect of temperature rise on the maximum shear modulus ($G_{max}$) and damping ratio was experimentally investigated. This study has significance in that the difference of dynamic soil properties between frozen and unfrozen soils and the effect of temperature rise on frozen soil were identified.

Study on the Property of Guided Wave Signal Analysis according to Defect Shape of Small Size (소구경 튜브 결함 형태에 따른 유도초음파 신호 해석 특성에 관한 연구)

  • Gil, Doo-Song;Ahn, Yeon-Shik;Jung, Gye-Jo;Park, Sang-Gi;Kim, Yong-Gun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.4
    • /
    • pp.410-417
    • /
    • 2012
  • Currently domestic thermal and nuclear power plants are comprised of many type's condenser and steam generator tubes to produce the electricity of good quality. There are some methods to inspect these tubes in the event that several defects were discovered in these facilities. Among many non-destructive methods, we used guided wave to inspect the soundness of tubes, because this method is very fast to detect the defect and very simple to install the equipment and also, can inspect up to the long range at a fixed point. Also, this method has a drawback that does not detect a very small size defect. So, we made an effort to overcome this drawback through the experimentation and signal analysis according to the size and shape of the defect through the manufacture of various artificial cracks capable to generate within the small size tube in the study and we anticipate that these detect limits can be overcome along with the development of the signal processing and manufacturing technology of the sensor for the inspection.

Precise Estimation of Nonlinear Parameter in Pulse-Like Ultrasonic Signal (펄스형 초음파 신호에서 비선형 파라미터의 정밀 추정)

  • Ha, Job;Jhang, Kyung-Young;Sasaki, Kimio;Tanaka, Hiroaki
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.2
    • /
    • pp.77-83
    • /
    • 2006
  • Ultrasonic nonlinearity has been considered as a solution for the detection of microcracks or interfacial delamination in a layered structure. The distinguished phenomenon in nonlinear ultrasonics is the generation of higher-order harmonic waves during the propagation. Therefore, in order to quantify the nonlinearity, the conventional method measures a parameter defined as the amplitude ratio of a second-order harmonic component and a fundamental frequency component included in the propagated ultrasonic wave signal. However, its application In field inspection is not easy at the present stage because no standard methodology has yet been made to accurately estimate this parameter. Thus, the aim of this paper is to propose an advanced signal processing technique for the precise estimation of a nonlinear ultrasonic parameter, which is based on power spectral and bispectral analysis. The method of estimating power spectrum and bispectrum of the pulse-like ultrasonic wave signal used in the commercial SAM (scanning acoustic microscopy) equipment is especially considered in this study The usefulness of the proposed method Is confirmed by experiments for a Newton ring with a continuous air gap between two glasses and a real semiconductor sample with local delaminations. The results show that the nonlinear parameter obtained tv the proposed method had a good correlation with the delamination.