• Title/Summary/Keyword: Testing & Evaluation Method

Search Result 1,052, Processing Time 0.028 seconds

SSD Test case generation method for early defect detection (불량 조기 검출을 위한 SSD 테스트 케이스 개발 방법)

  • Son, Myeong-Gyu;Lee, Jee-Hyong
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.25 no.6
    • /
    • pp.542-550
    • /
    • 2015
  • Usually, a new SSD (Solide State Drive) product is developed based on the software platform of the previous product. Therefore, when using the same test case was used to evaluate the previous generation evaluation of new products are a number of advantages may be, but a priority or weight is the inefficiency exists in the use of the evaluation resources due to not considered. A new method is proposed to prevent the waste of testing resources. Through the analysis of the evaluation data for the previous products, the combinations of testing cases with the highest probability for defect detections are identified. When the software is to be reused, most part of the base software platform is rarely modified and only some modules are added or modified. So, the whole software system may have similar types of defects with the previous products. By utilizing the evaluation data for the previous proucts, we can detect defects at an early stage.

A Development of Parallel Processing for Power Flow analysis (전력 조류 계산의 병렬처리에 관한 연구)

  • Lee, Chun-Mo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.51 no.2
    • /
    • pp.55-59
    • /
    • 2002
  • Parallel processing is able to be used effectively on computationally intense power system problems. But this technology is not still available is not only parallel computer but also parallel processing scheme. Testing these algorithms to ensure accuracy, and evaluation of their performance is also an issue. Although a significant amount of parallel algorithms of power system problem have been developed in last decade, actual testing on parallel computer architectures lies in the beginning stages because no clear cut paths. This paper presents Jacobian modeling method to supply the base being able to treat power flow by newton's method by the computer. This method is to assign and to compute teared blocks of sparse matrix at each parallel processors. The testing to insure accuracy of developed method have been done on serial computer by trying to simulate a parallel environment.

Development of a Test Method for the Evaluation of DNA Damage in Mouse Spermatogonial Stem Cells

  • Jeon, Hye Lyun;Yi, Jung-Sun;Kim, Tae Sung;Oh, Youkyung;Lee, Hye Jeong;Lee, Minseong;Bang, Jin Seok;Ko, Kinarm;Ahn, Il Young;Ko, Kyungyuk;Kim, Joohwan;Park, Hye-Kyung;Lee, Jong Kwon;Sohn, Soo Jung
    • Toxicological Research
    • /
    • v.33 no.2
    • /
    • pp.107-118
    • /
    • 2017
  • Although alternative test methods based on the 3Rs (Replacement, Reduction, Refinement) are being developed to replace animal testing in reproductive and developmental toxicology, they are still in an early stage. Consequently, we aimed to develop alternative test methods in male animals using mouse spermatogonial stem cells (mSSCs). Here, we modified the OECD TG 489 and optimized the in vitro comet assay in our previous study. This study aimed to verify the validity of in vitro tests involving mSSCs by comparing their results with those of in vivo tests using C57BL/6 mice by gavage. We selected hydroxyurea (HU), which is known to chemically induce male reproductive toxicity. The 50% inhibitory concentration ($IC_{50}$) value of HU was 0.9 mM, as determined by the MTT assay. In the in vitro comet assay, % tail DNA and Olive tail moment (OTM) after HU administration increased significantly, compared to the control. Annexin V, PI staining and TUNEL assays showed that HU caused apoptosis in mSSCs. In order to compare in vitro tests with in vivo tests, the same substances were administered to male C57BL/6 mice. Reproductive toxicity was observed at 25, 50, 100, and 200 mg/kg/day as measured by clinical measures of reduction in sperm motility and testicular weight. The comet assay, DCFH-DA assay, H&E staining, and TUNEL assay were also performed. The results of the test with C57BL/6 mice were similar to those with mSSCs for HU treatment. Finally, linear regression analysis showed a strong positive correlation between results of in vitro tests and those of in vivo. In conclusion, the present study is the first to demonstrate the effect of HU-induced DNA damage, ROS formation, and apoptosis in mSSCs. Further, the results of the current study suggest that mSSCs could be a useful model to predict male reproductive toxicity.

Development of MFL Testing System for the Inspection of Storage Tank Floor (저장탱크 바닥면 검사를 위한 누설자속 탐상 시스템 개발)

  • Won, Soon-Ho;Cho, Kyung-Shik;Lee, Jong-O;Chang, Hong-Keun;Joo, Gwang-Tae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.1
    • /
    • pp.38-44
    • /
    • 2002
  • MFL method is a qualitative inspection tool and is a reliable, fast and economical NDT method. The application of MFL method to the inspection of storage tank floor plates has been shown to be a viable means. Examination of tank floors previously depended primarily upon ultrasonic test methods that required slow and painstaking application. Therefor most ultrasonic inspection of storage tank has been limited to spot testing only. Our NDE group have developed magnetic flux leakage system to overcome limitation of ultrasonic test. The developed system consists of magnetic yoke, array sensor, crawler and software. It is proved that the system is able to detect artificial flaw like 3.2mm diameter, 1.2mm depth in 6mm thick steel plate.

A Study on the Evaluation Method for Penetration Test Method and Procedures (모의 침투 테스트 방법 및 절차의 평가 방법에 관한 연구)

  • Kang, Yong-Suk;Choe, Guk-Hyeon;Shin, Yong-Tae;Kim, Jong-Hee;Kim, Jong-Bae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.230-233
    • /
    • 2014
  • Latest Inforamtion security threats and risks change very rapidly, and there to strengthen the security level of the major companies and organizations are diversified attack to respond to a penetration test conducted. Penetration test(PenTest) is safer for the purpose of looking for vulnerabilities in computer systems by taking advantage of vulnerabilities discovered in the same way as a hacker attack. How to make a security vulnerability could be exploited by attempting to attack show. On the other hand, many security companies are testing in a variety of ways to be penetrated. However, penetration testing to evaluate the strength and reliability has not performed yet. Therefore, in this study, Penetration testing to validate and present a reliable method of evaluation. In this study, penetration testing, assessment information to provide the evaluation results are more reliable. And, as a result, efficient penetration test is expected to be possible.

  • PDF

On the Study of Software Reliability in Quality Testing Metrics (소프트웨어 신뢰도 품질 평가 메트릭에 대한 연구)

  • Jung Hye-Jung
    • Journal of Internet Computing and Services
    • /
    • v.7 no.2
    • /
    • pp.151-160
    • /
    • 2006
  • Software quality evaluation system and software evaluation criterion have to be defined to evaluate software reliability. In this study, we develop software reliability quality metrics for evaluating of software reliability and research for testing of suitable criteria of software reliability. To accomplish a study successfully, we have to estimate the failure time of software using the number of software bugs. Software reliability is very important in software quality. We propose the estimation of software reliability. We propose the software reliability metrics and the software testing method that the basis of international standard ISO/IEC 9126 in software testing metrics.

  • PDF

A Small Crack Length Evaluation Technique by Electronic Scanning (전자적 스캔에 의한 미소결함길이 평가기법)

  • Cho, Yong-Sang;Kim, Jae-Hoon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.1
    • /
    • pp.15-20
    • /
    • 2009
  • The results of crack evaluation by conventional UT(Ultrasonic Test)is highly depend on the inspector's experience or knowledge of ultrasound. Phased array UT system and its application methods for small crack length evaluation will be a good alternative method which overcome present UT weakness. This study was aimed at checking the accuracy of crack length evaluation method by electronic scanning and discuss about characteristics of electronic scanning for crack length evaluation. Especially ultrasonic phased array with electronic scan technique was used in carrying out both sizing and detect ability of crack as its length changes. The response of ultrasonic phased array was analyzed to obtain the special method of determining crack length without moving the transducer and detect-ability of crack minimal length and depth from the material. A method of crack length determining by electronic scanning for the small crack is very real method which has it's accuracy and verify the effectiveness of method compared to a conventional crack length determination.

A Study on the Integrity Evaluation of the Windings in Cast Resin Transformers Using Vertical Thermal Distribution Analysis (수직온도분포 분석을 이용한 몰드변압기 권선의 건전성 평가 연구)

  • Kim, HongRae;Lim, Young-Bae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.2
    • /
    • pp.94-99
    • /
    • 2005
  • This paper presents the integrity evaluation method of the windings in cast resin transformers using vertical thermal distribution analysis. The method is the result from comparing the temperature distribution in a sound condition specimen with that in the failure condition specimen layer-shorted by accelerated testing. The temperature distribution was acquisited by a infrared thermography system, and the Arrhenius equation was adopted to the accelerated testing. The proposed method may be available to detect the failures in cast resin transformers.

Strength Evaluation of Friction Welded SUH35/SUB3 Considering Stress Singularity (응력특이성을 고려한 SUH35/SUH3 마찰용접재의 강도평가)

  • Chung, Nam-Yong;Park, Chul-Hee
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.4
    • /
    • pp.59-67
    • /
    • 2006
  • Recently, application of friction welded SUH35/SUH3 is increasing in the manufacturing process of automotive engine valves For securing its reliability and a reasonable strength evaluation method, it is necessary to assess stress singularity under the residual stress condition on the friction welded interface between dissimilar materials. In this paper, strength evaluation method of friction welded materials was investigated by boundary element method and static tensile testing. An advanced method of quantitative strength evaluation for SUH35/SUH3 friction welded material is to be suggested by establishing fracture criterion by using stress singularity factors.