• Title/Summary/Keyword: Testing & Evaluation Method

Search Result 1,054, Processing Time 0.022 seconds

Evaluation of Efficacy and Risk of Intradermal Skin Testing for Antibiotic Pharmacotherapy in Hospital of Korea (한국 병원의 항생제 치료를 위한 항생제피부반응시험에 대한 유효성 및 위험성 평가)

  • Kim, Kyeong Ha;Lee, Yun Jeong;Lim, Sung Cil
    • YAKHAK HOEJI
    • /
    • v.58 no.4
    • /
    • pp.229-244
    • /
    • 2014
  • Background: Antibiotic skin test(AST) is very useful for the diagnosis of drug allergies to prevent immediate allergic reactions. Although it is a safe and widespread method, it is performed very diversely by doctors and nurses without consistency and it also differs from countries and hospitals. This study aims to evaluate the current practice of AST by nurses in Korea and to compare it to the general guidelines. Methods: During January 1, 2013 to May 20, 2013, the study was conducted as questionnaires and case-based survey. The questionnaires were given to the nurses who were randomly selected in various University Hospitals (University Hospitals N=276, and Medical center N=19). The case-based surveys were given to the nurses who were conducting AST at various wards of a University Hospital (N=130). The analysis and evaluations of the responses were carried out. Results: The response rate for the questionnaires was 97.6% and 130 cases of the actual case-based surveys were collected. There were clear differences between the survey results and the general guidelines, such as the method of skin test (skin prick test was not conducted), the method of patient selection for AST, test drugs, concentration, volume and interpretation of AST. AST conducted by nurses was highly variable and inconsistent, even among nurses who worked in the same wards and hospitals. Manufactured standard concentration antibiotic solution of AST showed consistency of concentration to a certain degree. Conclusion: Although the general guidelines have been published by several countries including Korea, these are not a great help to nurses as they lack details for conducting AST, practical consideration for nurses in the clinical setting, propagation and education. Standardized guideline for nurses should be published and it should be a safe, clear, comfortable and easily accessible protocol. Futhermore, additional antibiotic solutions to standardize skin test should be developed and manufactured. Lastly, it would be the pharmacists role to compare their hospitals antibiotic skin test methods with the standard guidelines and develop a protocol within the hospital for patients' safety, and to strive to consistently implement it.

Evaluation of Chemical Resistance Performance of Synthetic Rubber and Cement Based Injection Repair Materials Used in Underground Concrete Structures (지하 콘크리트 구조물에 적용되는 합성고무계 및 시멘트계 주입형 보수재료의 화학 저항성능평가)

  • Kim, Soo-Yeon;Lee, Yeon-Sil;Song, Je-Young;Kim, Byoungil;Oh, Sang-Keun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.5
    • /
    • pp.148-155
    • /
    • 2017
  • In this study, by using the international standards ISO TS 16774, Part 2 Test method for chemical resistance as a quality control method of injection type repair material used for leakage crack of underground concrete structure, the performance requirement against of chemical environment of underground concrete structures for repair materials was tested. For this testing 3 types for each of the 2 classes of repair materials(synthetic rubber, cement), with a total of 9 types repair materials, were selected and examined. As a result, the test results showed that the smallest performance deterioration by the change in the mass was with the synthetic rubber(RG) type as opposed to the cement type system, showing that the synthetic rubber type had the strongest relative resistance to chemical exposure. Furthermore, it is necessary to investigate the material with high resistance to chemical substances and to examine the material which can increase resistance to sodium hydroxide and sodium chloride in cement system. These results can be used as a basic index for the selection of repair materials with the strongest resistance to chemical environment found in concrete structures. In addition, it is expected that the test results derived in this study can be used as reference data that can be reflected in the quality improvement of the maintenance material to be developed later.

Real-Time Hybrid Testing Using a Fixed Iteration Implicit HHT Time Integration Method for a Reinforced Concrete Frame (고정반복법에 의한 암시적 HHT 시간적분법을 이용한 철근콘크리트 골조구조물의 실시간 하이브리드실험)

  • Kang, Dae-Hung;Kim, Sung-Il
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.15 no.5
    • /
    • pp.11-24
    • /
    • 2011
  • A real-time hybrid test of a 3 story-3 bay reinforced concrete frame which is divided into numerical and physical substructure models under uniaxial earthquake excitation was run using a fixed iteration implicit HHT time integration method. The first story inner non-ductile column was selected as the physical substructure model, and uniaxial earthquake excitation was applied to the numerical model until the specimen failed due to severe damage. A finite-element analysis program, Mercury, was newly developed and optimized for a real-time hybrid test. The drift ratio based on the top horizontal displacement of the physical substructure model was compared with the result of a numerical simulation by OpenSees and the result of a shaking table test. The experiment in this paper is one of the most complex real-time hybrid tests, and the description of the hardware, algorithm and models is presented in detail. If there is an improvement in the numerical model, the evaluation of the tangent stiffness matrix of the physical substructure model in the finite element analysis program and better software to reduce the computational time of the element state determination for the force-based beam-column element, then the comparison with the results of the real-time hybrid test and the shaking table test deserves to make a recommendation. In addition, for the goal of a "Numerical simulation of the complex structures under dynamic loading", the real time hybrid test has enough merit as an alternative to dynamic experiments of large and complex structures.

Evaluation of removal forces of implant-supported zirconia copings depending on abutment geometry, luting agent and cleaning method during re-cementation

  • Rodiger, Matthias;Rinke, Sven;Ehret-Kleinau, Fenja;Pohlmeyer, Franziska;Lange, Katharina;Burgers, Ralf;Gersdorff, Nikolaus
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.3
    • /
    • pp.233-240
    • /
    • 2014
  • PURPOSE. To evaluate the effects of different abutment geometries in combination with varying luting agents and the effectiveness of different cleaning methods (prior to re-cementation) regarding the retentiveness of zirconia copings on implants. MATERIALS AND METHODS. Implants were embedded in resin blocks. Three groups of titanium abutments (pre-fabricated, height: 7.5 mm, taper: $5.7^{\circ}$; customized-long, height: 6.79 mm, taper: $4.8^{\circ}$; customized-short, height: 4.31 mm, taper: $4.8^{\circ}$) were used for luting of CAD/CAM-fabricated zirconia copings with a semi-permanent (Telio CS) and a provisional cement (TempBond NE). Retention forces were evaluated using a universal testing machine. Furthermore, the influence of cleaning methods (manually, manually in combination with ultrasonic bath or sandblasting) prior to re-cementation with a provisional cement (TempBond NE) was investigated with the pre-fabricated titanium abutments (height: 7.5 mm, taper: $5.7^{\circ}$) and SEM-analysis of inner surfaces of the copings was performed. Significant differences were determined via two-way ANOVA. RESULTS. Significant interactions between abutment geometry and luting agent were observed. TempBond NE showed the highest level of retentiveness on customized-long abutments, but was negatively affected by other abutment geometries. In contrast, luting with Telio CS demonstrated consistent results irrespective of the varying abutment geometries. Manual cleaning in combination with an ultrasonic bath was the only cleaning method tested prior to re-cementation that revealed retentiveness levels not inferior to primary cementation. CONCLUSION. No superiority for one of the two cements could be demonstrated because their influences on retentive strength are also depending on abutment geometry. Only manual cleaning in combination with an ultrasonic bath offers retentiveness levels after re-cementation comparable to those of primary luting.

A STUDY ON THE EVALUATION OF POLYMERIZATION SHRINKAGE OF COMPOSITE AND COMPOMER USING STRAIN GAUGE METHOD (스트레인 게이지법을 이용한 복합레진과 컴포머의 중합수축 평가에 관한 연구)

  • Kim, Yeun-Chul;Kim, Jong-Soo;Kwon, Soon-Won;Kim, Yong-Kee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.1
    • /
    • pp.19-29
    • /
    • 2002
  • The purpose of this study was to compare the polymerization shrinkage and the compressive strength of composite and compomer cured with two different light sources ; conventional halogen-light curing unit and recently-developed plasma arc curing unit. The 'strain gauge method' was used for determination of polymerization shrinkage and the compressive strength was measured by universal testing machine. The results of the present study can be summarized as follows: 1. Filling materials in polyethylene molds showed the initial expansion in the early phase of polymerization. This was followed by the rapid contraction in volume during the first 60 seconds and gradually diminished as curing process continued. 2. The polymerization shrinkage in tooth samples was generally lower than in the mold samples. 3. The generally lower amount of linear polymerization shrinkage was observed in compomer and plasma arc curing unit group when compared to composite and conventional curing unit. 4. The higher compressive strength values was found in composite groups regardless curing methods. The results of this study strongly support the application of plasma arc system and fluoride-containing compomer in the field of clinical pediatric dentistry claiming its effectiveness in curing the esthetic dental materials and the anticariogenic capacity.

  • PDF

A study of the measurement systems implementation for the interior impulse noise (실내 충격소음 측정시스템 구현에 관한 연구)

  • Song, Kee-Hyeok;Chung, Sung-Hak
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.6
    • /
    • pp.93-100
    • /
    • 2014
  • The objective of this study is to propose the measurement system implementation method for the evaluation and measurement of the indoor-impulsive over 170 dB noise source. For the purpose of measuring impulse noise, design and implementation constructed followed subsystems of the testing center, microphone, ear simulator, head and torso simulator and so on. Measurement systems for the accuracy and reliability of impulse noise are implemented when measuring 3 ways of measurements method by the simultaneous measurement system design. For the accuracy and reliability of three mutually indoor-impulse noise measurements were compared, three kinds of measuring methods in accordance with the peak sound pressure level and octave band. Comparing the results of data, the indoor-impulse noise by analyzing a frequency characteristic was validated in difference for the statistical significance. Result are determined by the influence of the reflected wave. Therefore, the flexible size of the interior test site while interior impulse noise measurement system was constructed. Throughout this system can be affected by parameters that are the impulse noise source and the corresponding frequency-characteristic analysis to determine the spectrum of the reflected wave. And, in the near future, indoor impulse noise measurement systems for acquisition and analysis are utilized in useful data.

Development of Guidelines for Setting Up Sensory Integration Rooms in Korea Using the Delphi Method (국내 감각통합치료실 구성을 위한 가이드라인 개발: 델파이 연구)

  • Lee, Chan-Hwa;Hwang, Sun-Mi;Park, Seo-Yul;Chae, Song-Eun;Kim, Jung-Ran
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.18 no.2
    • /
    • pp.1-14
    • /
    • 2020
  • Objective : This study presents guidelines for setting up a sensory integration room by applying the Delphi method. Methods : The Delphi method was applied in a survey of 22 expert panels asked to review sensory integration therapy from May to June 2020 to collect expert opinions. The survey was conducted in two rounds. The first round involved the collection of opinions based on prior research that used a total of 40 assessment tools, 23 closed questions about treatment tools, and 10 questions about the physical environment. Based on the results of the first round, the second was conducted using a process of item deletion and modification. Results : A total of 59 items were selected in the first round of the survey. In the second the contents of these 59 items were analyzed: each item scored .42 or higher, so no items were deleted. The stability of the survey was also calculated and found to be less than 0.5, so no further testing was required. The average content feasibility ratio of the final Delphi survey was .92, stability .15, convergence .36, and consensus .80, showing high agreement. Conclusion : This study is expected to help institutions and clinical therapists who want to create a sensory integration therapy room in their facilities by examining the physical environment, treatment tools, and evaluation tools used in sensory integration therapy rooms and understanding the views on such environments obtained from the clinical site to sensory integration therapists.

Agriculture Pollution and its Countermeasures with Special Consideration of Pesticides (작물생산과 농업공해 및 그 대책)

  • Li, Gwo-Chen
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.27 no.4
    • /
    • pp.340-360
    • /
    • 1982
  • Because of the continuing rapid increase in pesticide usage in Taiwan, much attention has been focus on pesticide contamination of food and effect of pesticides on human and environmental health. The Plant Protection Center (PPC) conducts safety evaluation of pesticides usee! in Taiwan. The pesticides are classified into different groups based on their acute toxicities. Pesticides which are classified into extremely toxic group are not allow to used on short term crops or the continuously harvest crops. The acute toxicity of pesticides to the beneficial insects are also studied, special attention has been paid to the two predators of rice brown planthopper. 60% of cultivated land in Taiwan are paddy field; therefore, acute fish toxicity was taken into consideration when a pesticide was applied for registration to be used in the paddy. Fish toxicities were evaluated by the dangerous rating value which is the amount of pesticide residue in the field water over the TLM value. Mutagenicity of pesticides was continuously evaluated by using Arne's microbial testing method. Island wide survey of residual levels of pesticides of known pollutants such as chlorinated hydrocarbon . insecticides, mercurial compounds in soil, water and biological samples were carried out constantly. The potential of a new1y Imported esticides to pollute the environment were studied by using model ecosystem. Ecological magnification (EM) of a chemical was calculated from model ecosystem. A chemical was considered as a pollutant when its EM value over 5000. In order to ensure the levels of pesticides residue of the crop within the safety limit. The 'tolerance' of pesticides on different crop groupings were established base on 1) acceptable daily intake value of individual pesticides, 2) average daily consumption of each crop groupings by Chinese person, 3) Actual residues of pesticides. on different crops obtained from supervised trials. Total about 79 pesticides for which the tolerances have been established on different crop groupings. Because the intensive agricultural system was adopted in Taiwan. The phytotoxicity of pesticides to the non-target crops was therefore become one of the important factor in the safety evaluation of pesticide usage. These will include 1) direct injury, 2) injury caused by pesticide polluted irrigation water, 3) injury caused by the pesticide polluted soil, 4) reduction of growth caused by the effect of pesticide on the soil microorganisms. This paper will reviewed all the aspects mentioned in the previous .paragraphs. Most the works have done in Taiwan by the PPC.y the PPC.

  • PDF

A Study of the Quantitative, Qualitative Analysis on Optimizing Diagnostic Imaging Device Selection in Nasopharynx MRI (비 인두 자기공명 검사 시 최적의 진단영상 장치 선택에 관한 정량, 정성적 평가에 관한 연구)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.1035-1043
    • /
    • 2019
  • The object of is this research is to find out the optimal Tesla by evaluating SNR and CNR, after testing 1.5 T and 3.0 T. The randomly selected patients tested by nasopharynx MRI transmitted in PACS were applied to the research. Two MRI units(1.5 T, 3.0 T) was used for analyzing the data. As a method of analysis, in T1W highlighting and T1 fat removal images, we set up a certain area of interest and evaluated the SNR and CNR on tongue, spinal cord, masseter muscle, fat, parotid gland, and tumor tissue. We evaluated the SNR and CNR by quantitative analysis of six tissue, measuring the quality of images for uniform fat removal, magnetic sensitivity artifact on a four-point scale by qualitative analysis. The statistical significance of this date analysis was based on independent sample verification and was accepted when the P value was less than 0.05. As a result of analysis of both devices, 3.0 T was high in the quantitative evaluation, while 1.5 T was high in the qualitative evaluation. Considering the advantages and disadvantages of each device, and if the device is selected complementarily and applied to patients, it is believed that it will provide the optimal information.

Evaluation on the Applicability of Monitoring for Urban Railway Structure Using Brillouin Optical Correlation Domain Analysis Based Distributed Optical Fiber Sensor (브릴루앙 광 상관영역 기반 분포형 광섬유를 활용한 도시철도 구조물의 모니터링 적용성 평가)

  • Chae, Deokho;Lee, Sungjin;Lee, Jin-Wook
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.9
    • /
    • pp.13-19
    • /
    • 2018
  • Recently, there have been various problems aroused on the domestic infrastructures as the domestic cities become old. Accordingly, the national concerns grow on the urban railway and the related structures, which brings the national interests are brought on the research on the maintenance and rehabilitation of the old infrastructures. The underground structure of urban railway are checked with the strain gages or fiber brag grating (FBG) sensors on the railway. However, these methods are known to have resolution limitations on the investigations of the specified abnormal section. Therefore, the applicability of the Brillouin Optical Correlation Domain Analysis (BOCDA) based distributed fiber optic sensor system on the railway was evaluated in this study. The constructed BOCDA fiber optic sensor system shows high resolution of 10, 20, 50, 100 cm and capability of continuous monitoring on overall or specified section within 2 km range. The applicability evaluation was performed on the 250 m distribution of fiber optic sensors abandoned railway for continuous monitoring. The applicability of the system on the specified area was evaluated with wheel load testing. As a result, data loss tends to increase with the reduction of spatial resolution from 1.0 m to 0.1 m. Even though the measuring speed is reduced with lower spatial resolution, data accuracy increases on the location and deformation. The system can be applicable to various structures if the proper distribution method is invented later.