• Title/Summary/Keyword: Test-bed Application

Search Result 176, Processing Time 0.02 seconds

Application Effect of Heating Energy Saving Package on Venlo Type Glasshouse of Paprika Cultivation (파프리카 재배 벤로형 유리온실에서 난방에너지 절감 패키지 기술 적용효과)

  • Kwon, Jin Kyung;Jeon, Jong Gil;Kim, Seung Hee;Kim, Hyung Gweon
    • Journal of Bio-Environment Control
    • /
    • v.25 no.4
    • /
    • pp.225-231
    • /
    • 2016
  • Glasshouse heating package technologies to improve energy usage efficiency in winter were developed. Heating package was composed of the ground water source heat pump with heating capacity of 105kW, the aluminum multi-layer thermal curtain with six layers of different materials and the root zone local heater with XL pipes of ${\phi}20mm$. Venlo type glasshouse($461m^2$) with the heating package was compared with the same type and area control glasshouse with the light oil boiler, the usual non-woven fabric thermal curtain with respect to the glasshouse inside temperature, relative humidity, crop growth, and heating energy consumption. The results of test in paprika cultivation glasshouses showed that the air temperature inside glasshouse with aluminum multi-layer thermal curtain was maintained $2.2^{\circ}C$ higher than that of control glasshouse in un-heating night time and the temperature in bed with root zone local heating was $4.7^{\circ}C$ higher than that in bed without local heating. Average heating coefficient of performance(COP) of the ground water source heat pump used in paprika cultivation was 3.7 and the glasshouse inside temperature was maintained at $21^{\circ}C$ of heating set up temperature. The heating energy consumptions per 10a were measured at 14,071L of light oil and 364kWh of electric power for the control glasshouse and 35,082kWh for the glasshouse applied heating package. As results, the heating cost of the glasshouse applied heating package was 87 percent lower than that of control glasshouse. The growths of paprika in glasshouses of control and applied heating package did not show any significant difference.

Critical Pathway Development for the Hysterectomy Patients and its applied Effect (자궁적출술 환자를 위한 critical pathway 개발과 적용효과)

  • Noh, Gi-Ok;Park, Kyung-Sook
    • Women's Health Nursing
    • /
    • v.6 no.2
    • /
    • pp.234-257
    • /
    • 2000
  • At present in the medical care, the study and effort for producing health service to consider efficiency, effectiveness, and quality are urgently called for because of the difficulty in the keen competition according to the inter- nationalization and opening, the operation in the medical institution service testing system, the change in the medical policy of KDRGs, and the lack of the health care cost increasing rate. As an alternative, the case management for the new management system is introduced in the U.S., and the Critical Pathway that is the method designing the contents of activity and its result has been developed and applied in order to anticipate and manage the patient-outcome for the realization of the cost-effective case-management. Thus, this study intended to analyze the effectiveness to obtain by developing the Critical Pathway presented as the method to improve the quality-betterment and cost effectiveness through the continuous and consistent patient management for the hysterectomy patient and applying it to the real practice. As a study method, this author formed a conceptual framework through considering five Critical Pathway used in the current U.S. and three Critical Pathway presented in the literature to develop the Critical Pathway for the hysterectomy patient, and made out the preliminary Critical Pathway through reviewing the old chart. This author made the verified the validity of the expert group about the developed Critical Pathway, and to confirm the possibility of practice application, completed and settled the final Critical Pathway after using the Critical Pathway to the hysterectomy patient from March 1st to 15th, 1997. Finally, to analyze the application-effect of the developed Critical Pathway, this author offered health care service applying the Critical Pathway to the hysterectomy patient from April 15th to August 31th, 1997. The guide for the Critical Pathway was carried out in advance by outpatient setting nurse for outpatient setting visit before the operation, and after hospitalization the primary nurse monitored the execution degree on the every duty. After discharge this author surveyed the complication through phone visiting, and one month after discharge surveyed the patient's reaction about the offered service when outpatient setting visit and analyzed the result. The source for health care cost was obtained by the statistics about the hospital charge which was offered by the General Business Department. The results were as follows. 1. It was decided that the vertical line of the Critical Pathway was made up of eight items such as monitoring/assessment, treatment, line/drains, activity, medication, lab test, diet, patient teaching, and the horizontal line of the Critical Pathway was made up of from hospitalization to discharge. 2. After the analysis of service contents through reviewing the old chart, it was decided that the horizontal line of the preliminary Critical Pathway was made up of from hopitalization to fourth postoperative day, and the vertical line of it was divided into eight items which were the contents to occur with the time frame of the horizontal line. 3. After the verifying the validity of the expert group about the preliminary Critical Pathway, the horizontal line was amended from hopitalization to third postoperative day, and taking their consensus, some contents of the horizontal line was amended and deleted. 4. From March 1st to 15th, 1997, to confirm the clinical suitability, this author offered eight hysterectomy patients the medical service through the Critical Pathway. The result was that three of them could be discharged at the expected discharge day, and the others later than that day. Supplementing the preliminary Critical Pathway through analyzing the cause of that delay- case, this author developed the final Critical Pathway. 5. There were no significant differences between the experimental and the control group in the incidence of complication(P > 0.05). 6. The 92.4% of experimental group was satisfied with the Critical Pathway service. 7. The length of hospital stay of the experimental group offered with the Critical Pathway service was 4.6 days and there was a significant difference that it was 1.3 days shorter than that of the control group(t=-29.514, P=0.000). 8. There wsa a significant difference that the mean medical charge per one patient of the experimental group offered the Critical Pathway service was cheaper \124,150 than that of the control group(t=-9.826, P=0.000). 9. The result that the author assumed and analyzed hospital income with the rate of turning bed was assumed that the increase of hospital income was \63,245,072 for that study, and the income increase was expected with \68,704,864 for a year. The result that this author applied the Critical Pathway to the hysterectomy patient have no differences in the incidence of complication, high satisfaction with that service, and the length of hospital stay decreased in the experimental group, and the mean hospital charge per one patient decreased, but hospital income increased. Suggestions for further study and nursing practice are as follows. 1. The study to apply the Critical Pathway for a year, verify the validity, and measure the effect repeatedly is needed. 2. To apply and manage the Critical Pathway effectively, the study to computerize it is needed. 3. The study to develop hospital-based Critical Pathway about other diseases or procedure, and measure the effect is needed.

  • PDF

A Study on Effects of Air-delivery Rate upon Drying Rough Rice with Unheated Air. (벼의 자연통풍건조에 있어서 통풍량이 건조에 미치는 영향에 관한 연구)

  • 이상우;정창주
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.16 no.1
    • /
    • pp.3293-3301
    • /
    • 1974
  • An experimental work was conducted by using a laboratory-made model dryer to investigate the effect of the rate of natural forced-air on the drying rate of rough rice which was deposited in the deep-bed. The dryer consisted of 8 cylinderical containers with grain holding screen at their bottoms, each of which having 30cm in diameter and 15cm in height. The containers were sacked vertically with keeping them air-tight by using paper tape during dryer operation. Two separate layers of containers were operated in the same time to have two replications. The moisture contents of grains within each bins after predetermined period of dryer operation were determined indirectly by measuring the weight of the individual containers. The air-rates were maintained at 6 levels, or 5, 8, 10, 15, 18 and 20 millimenters of static head of water. The roomair conditions during dryer operation were maintained in the range of 10-l5$^{\circ}C$ in temperature and 40-60% in relative humidity. The results of the study are summarized as follows: 1. Drying characteristics of the grains in the bottom layers were approximately the same regardless of airdelivery rates, giving the average drying rate as about 0.35 percent per hour after 40-hour drying period, during which moisture content (w. b.) reduced from 24 percent to about 10 percent. 2. After about 40-hour drying period, the mean drying rates increased from 0.163 percent per hour to 0.263 percent per hour as air-flow rates increased from 5mm to 87.16mm of static head of water. In the same time, the moisture differences of grains between lower and upper layers varied from 12.7 percent at the air rate of 5mm of water head to 7.5 percent at the air-flow rate of 20mn of water head. Thus, the greater the air-flow rate was, the more overall improvement in drying performance was. Additionally, from the result of ineffectiveness of drying grain positioned at 70cm depth or above by the air rate of 5mm of static head of water it may be suggested in practical application that the height of grain deposit would be maintained adequately within the limits of air-rates that may be actually delivered. 3. Drying after layer-turning operation was continued for about 30 hours to test the effectiveness of reducing moisture differences in the thick layers. As a result of this layer-turning operation, moisture distribution through layers approached to narrow ranges, giving the moisture range as about 7 percent at air-flow rate of 5mm head of water, about 3 percent at 10mm head about 2 percent at 15mm head, and less than 1 percent at 20mm head. In addition, from the desirable results that drying rate was rapid in the lower layers and dully in the upper layers, layer-turning operation may be very effective in natural air drying with deep-layer grain deposit, especially when the forced air was kept in low rate. 4. Even though the high rate of air delivery is very desirable for deep-layer natural-air drying of rough rice, it can be happened that the required air delivery rate could not be attained because of limitation of power source available on farms. To give a guide line for the practical application, the power required to perform the drying with the specified air rate was analyzed for different sizes of drying bin and is given in Table (5). If a farmer selects a motor of which size is 1 or {{{{1 { 1} over {2 } }}}} H.P. and air-delivery rate which ranges from 8~10mm of head, the diameter of grain bin may be suggested to choose about 2.4m, also power tiller or other moderate size of prime motor may be recommended when the diameter of grain bin is about 5.0m or more for about 120cm grain deposit.

  • PDF

Adequate Standard Pot and Number of Plants Per Tree of Raising Seeding Pot on the Foxtail Millet Transplanting Culture in the Southern Province (남부지방 조 이식재배시 육묘폿트의 적정규격 및 주당본수)

  • Kim, Yong-Soon;Kim, Dong-Kwan;Choi, Jin-Gyung;Park, Heung-Gyu;Kim, Myeong-Seok;Shin, Hae-Ryoung;Choi, Gyung-Ju;Yun, Jong-Tag
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.60 no.1
    • /
    • pp.23-28
    • /
    • 2015
  • This study was performed to investigate the adequate standard pot and number of plants per tree of raising seeding pot on the foxtail millet transplanting culture in the southern province. Due to the various application of wellbeing-health food recently, for upbringing of the foxtail millet, millet and sorghum in minor cereals, R & D and policy support is being promoted actively. The foxtail millet growing season is so short from 90 to 130 days, and it is large variations for a growth temperature. The main results are as follows. When it comes to foxtail millet transplantation, seedling quality of 406 holes, 200 holes and 162 holes of raising seeding pot type were not all significant, and field rooting percentage is accounted for all 94 to 95%. Yield of a foxtail millet was exposed in 406holes 305 kg/10a>162holes 303 kg> 200holes 302 kg order, and it was no significance between test processing. When it's the raising seeding transplanting culture, in case of pot culture, 406holes pot culture were reduced the bed soil cost 63%, pot 50%, working hours 18% for 200holes pot. Transplanting seedling quality per a foxtail millet transplanting culture method, dry weight was high inclination as transplanting number of plant is less, and field rooting percentage displayed more than all 95%. Yield appeared to 2 plants seedling transplanting 315kg/10a> 3 plants seedling transplanting 304kg>1 plant seedling transplanting 256kg order. The projected cost per the pot-sort on the raising seeding transplanting culture of foxtail millet, the seedling transplanting culture of 406holes was reduced 40% percentages compared to 200holes as 76,230won/10a. As a result, 406holes pot and 2plants seedling transplanting culture, labor-saving culture was possible.

Development and Application of Multi-Functional Floating Wetland Island for Improving Water Quality (수질정화를 위한 다기능 인공식물섬의 개발과 적용)

  • Yoon, Younghan;Lim, Hyun Man;Kim, Weon Jae;Jung, Jin Hong;Park, Jae-Roh
    • Ecology and Resilient Infrastructure
    • /
    • v.3 no.4
    • /
    • pp.221-230
    • /
    • 2016
  • Multi-functional floating wetland island (mFWI) was developed in order to prevent algal bloom and to improve water quality through several unit purification processes. A test bed was applied in the stagnant watershed in an urban area, from the summer to the winter season. For the advanced treatment, an artificial phosphorus adsorption/filtration medium was applied with micro-bubble generation, as well as water plants for nutrient removal. It appeared that the efficiency of chemical oxygen demand (COD) and total phosphorus (T-P) removal was higher in the warmer season (40.9%, 45.7%) than in the winter (15.9%, 20.0%), and the removal performance (suspended solid, chlorophyll a) in each process differs according to seasonal variation; micro-bubble performed better (33.1%, 39.2%) in the summer, and the P adsorption/filtration and water plants performed better (76.5%, 59.5%) in the winter season. From the results, it was understood that the mFWI performance was dependent upon the pollutant loads in different seasons and unit processes, and thus it requires continuous monitoring under various conditions to evaluate the functions. In addition, micro-bubbles helped prevent the formation of anaerobic zones in the lower part of the floating wetland. This resulted in the water circulation to form a new healthy aquatic ecosystem in the surrounding environment, which confirmed the positive influence of mFWI.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013 (설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.