Reliability and Validity of the Korean Version of Melbourne Low-Vision ADL Index (한국판 맬버른 저시력 일상생활지수(Melbourne Low-vision ADL Index: MLVAI)의 신뢰도 및 타당도)

  • Yoo, Yeon Hwan;Park, Ji-Hyuk;Jung, Min-Ye;Park, Hae Yean
    • Therapeutic Science for Rehabilitation
    • /
    • v.7 no.2
    • /
    • pp.51-61
    • /
    • 2018
  • Objective: The purpose of this study was performed to modify the performance-based assessment tool, Melbourne Low-Vision ADL Index (MLVAI) had been developed in Australia to suit the Korea culture to verify the reliability and validity. Methods: The subjects were only over the age of 20 living in communities, 26 with low-vision and 42 normal persons. The Korean MLVAI was completed through the expert translation verification and validation of the configuration tool. The validity of the Korean MLVAI was established through the content, discriminant, and convergent validity. Also, the reliability was analyzed through internal consistency reliability for the items, test-retest, and interrater reliability. Results: The Content Validity Index(CVI) was more than .78. There was a statically significant low in low-vision. Also, there was a statically significant low in low-vision. The convergent validity was determined the correlation coefficient of .751 analyzing LVQOL and Korean MLVAI total score, had a significant correlation(p<.05). Cronbach's ${\alpha}$ coefficient indicated an internal consistency of .983(p<.05). Test-retest reliability had a high, significant correlation of .976 and interrater reliability had a high, an intraclass correlation coefficient of .91(p<.05). Conclusion: The results of this study mean that the Korean MLVAI which was modified to fit the Korean is the ADL assessment tool with both validity and reliability. Based on this study, the Korean MLVAI can be used as a useful ADL assessment for OT interventions in low vision.

Psychometric Properties of the Persian Version of Satisfaction with Care EORTC-in-patsat32 Questionnaire among Iranian Cancer Patients

  • Pishkuhi, Mahin Ahmadi;Salmaniyan, Soraya;Nedjat, Saharnaz;Zendedel, Kazem;Lari, Mohsen Asadi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.23
    • /
    • pp.10121-10128
    • /
    • 2015
  • Background: Cancers impose an increasing burden on health of the populations and individuals, but little is known about cancer patient satisfaction with care. The aim of this study was to assess the psychometric properties of the Persian version of European Organisation for Research and Treatment of Cancer (EORTC) In-Patsat32, as a recently developed questionnaire to assess cancer patient satisfaction with care and information provided during hospital admission. Materials and Methods: Complying with EORTC protocols, the Persian version of Inpatsat32 was translated and piloted in a small group of patients, then applied to 380 cancer patients admitted to different oncology wards in Tehran. Validity (convergent, discriminant, and divergent) and reliability of the tool was assessed through using multitrait analysis, factor analysis, intraclass correlations, Chronbach's alpha and test-retest (on a sample of 70 patients). Results: Good acceptance and high sensitivity of the questionnaire with low floor and ceiling effects were recognized, indicating power of the instrument to detect differences between groups with heterogeneous levels of satisfaction. Multitrait scaling analyses supported the convergent validity of the majority of scales (correlation coefficient >0.4) and favorable discriminant validity (item own scale correlation >0.8). There was no correlation between In-patsat32 scales and the EORTC-C30, which measures different concepts, confirming divergent validity of the tool. Internal consistency for all domains was high (${\alpha}$ >0.70) except for the hospital access score and the test-retest reliability was excellent (r=0.86-0.96). There was a weak responsiveness to change except for nurses technical skills. Principle component analysis confirmed five domains with much improved internal consistency (${\alpha}$ >0.9). Conclusions: The Persian version of the EORTC-in-patsat32 module is a reliable and valid instrument to measure cancer patient satisfaction with care received during their hospitalization period and can be utilized in clinical cancer research.

Psychometric Validation of the Bahasa Malaysia Version of the EORTC QLQ-CR29

  • Magaji, Bello Arkilla;Moy, Foong Ming;Roslani, April Camilla;Law, Chee Wei;Raduan, Farhana;Sagap, Ismail
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.18
    • /
    • pp.8101-8105
    • /
    • 2016
  • Background: This study examined the psychometric properties of the Bahasa Malaysia (BM) version of the European Organization for Research and Treatment of Cancer (EORTC) Colorectal Cancer-specific Quality Of Life Questionnaire (QLQ-CR29). Materials and Methods: We studied 93 patients recruited from University Malaya and Universiti Kebangsaan Medical Centers, Kuala Lumpur, Malaysia using a self-administered method. Tools included QLQ-C30, QLQ-CR29 and Karnofsky Performance Scales (KPS). Statistical analyses included Cronbach's alpha, test-retest correlations, multi-traits scaling and known-groups comparisons. A p vaue ${\leq}0.05$ was considered significant. Results: The internal consistency coefficients for body image, urinary frequency, blood and mucus and stool frequency scales were acceptable (Cronbach's alpha ${\alpha}{\geq}0.65$). However, the coefficients were low for the blood and mucus and stool frequency scales in patients with a stoma bag (${\alpha}=0.46$). Test-retest correlation coefficients were moderate to high (range: r = 0.51 to 1.00) for most of the scales except anxiety, urinary frequency, buttock pain, hair loss, stoma care related problems, and dyspareunia (r ${\leq}0.49$). Convergent and discriminant validities were achieved in all scales. Patients with a stoma reported significantly higher symptoms of blood and mucus in the stool, flatulence, faecal incontinence, sore skin, and embarrassment due to the frequent need to change the stoma bag (p < 0.05) compared to patients without stoma. None of the scales distinguished between patients based on the KPS scores. There were no overlaps between scales in the QLQ-C30 and QLQ-CR29 (r < 0.40). Conclusions: the BM version of the QLQ-CR29 indicated acceptable psychometric properties in most of the scales similar to original validation study. This questionnaire could be used to complement the QLQ-C30 in assessing HRQOL among BM speaking population with colorectal cancer.

Reliability and Validity of the Korean Version of the Post-Traumatic Stress Disorder Checklist in Public Firefighters and Rescue Workers (소방공무원과 구조대원에서 한국어판 Post-Traumatic Stress Disorder Checklist의 신뢰도와 타당도)

  • Park, Shinwon;Jeong, Hyeonseok S.;Im, Jooyeon Jamie;Jeon, Yujin;Ma, Jiyoung;Choi, Yera;Ban, Soonhyun;Kim, Sungeun;Yu, Siyoung;Lee, Sunho;Jeon, Saerom;Kang, Ilhyang;Lee, Bora;Lee, Sooyeon;Son, Jihee;Lim, Jae-ho;Yoon, Sujung;Kim, Eui-Jung;Kim, Jieun E.;Lyoo, In Kyoon
    • Korean Journal of Biological Psychiatry
    • /
    • v.23 no.1
    • /
    • pp.29-36
    • /
    • 2016
  • Objectives Firefighters and rescue workers are likely to be exposed to a variety of traumatic events; as such, they are vulnerable to the risk of post-traumatic stress disorder (PTSD). The psychometric properties of the Korean version of the PTSD Checklist (PCL), a widely used self-report screening tool for PTSD, were assessed in South Korean firefighters and rescue workers. Methods Data were collected via self-report questionnaires and semi-structured clinical interviews administered to 221 firefighters. Internal consistency, item-total correlation, one-week test-retest reliability, convergent validity, and divergent validity were examined. Content validity of the PCL was evaluated using factor analysis and receiver operating characteristic (ROC) analyses were used to estimate the optimal cutoff point and area under the curve. Results The PCL demonstrated excellent internal consistency (${\alpha}=0.97$), item-total correlation (r = 0.72-0.88), test-retest reliability (r = 0.95), and convergent and divergent validity. The total score of PCL was positively correlated with the number of traumatic events experienced (p < 0.001). Factor analysis revealed two theoretically congruent factors: re-experience/avoidance and numbing/hyperarousal. The optimal cutoff was 45 and the area under the ROC curve was 0.97. Conclusions The Korean version of the PCL may be a useful PTSD screening instrument for firefighters and rescue workers, further maximizing opportunities for accurate PTSD diagnosis and treatment.

Development and Validation of a Novel Generic Health-related Quality of Life Instrument With 20 Items (HINT-20)

  • Jo, Min-Woo;Lee, Hyeon-Jeong;Kim, Soo Young;Kim, Seon-Ha;Chang, Hyejung;Ahn, Jeonghoon;Ock, Minsu
    • Journal of Preventive Medicine and Public Health
    • /
    • v.50 no.1
    • /
    • pp.38-59
    • /
    • 2017
  • Objectives: Few attempts have been made to develop a generic health-related quality of life (HRQoL) instrument and to examine its validity and reliability in Korea. We aimed to do this in our present study. Methods: After a literature review of existing generic HRQoL instruments, a focus group discussion, in-depth interviews, and expert consultations, we selected 30 tentative items for a new HRQoL measure. These items were evaluated by assessing their ceiling effects, difficulty, and redundancy in the first survey. To validate the HRQoL instrument that was developed, known-groups validity and convergent/discriminant validity were evaluated and its test-retest reliability was examined in the second survey. Results: Of the 30 items originally assessed for the HRQoL instrument, four were excluded due to high ceiling effects and six were removed due to redundancy. We ultimately developed a HRQoL instrument with a reduced number of 20 items, known as the Health-related Quality of Life Instrument with 20 items (HINT-20), incorporating physical, mental, social, and positive health dimensions. The results of the HINT-20 for known-groups validity were poorer in women, the elderly, and those with a low income. For convergent/discriminant validity, the correlation coefficients of items (except vitality) in the physical health dimension with the physical component summary of the Short Form 36 version 2 (SF-36v2) were generally higher than the correlations of those items with the mental component summary of the SF-36v2, and vice versa. Regarding test-retest reliability, the intraclass correlation coefficient of the total HINT-20 score was 0.813 (p<0.001). Conclusions: A novel generic HRQoL instrument, the HINT-20, was developed for the Korean general population and showed acceptable validity and reliability.

Surface Topographic Measurement Method for Assessing Lower Extremity Alignment: Examination on a novel clinical and research Tool (하지 정렬 평가를 위한 체표면 토포그래피를 이용한 측정법: 새로운 임상 및 연구 도구에 대한 검토)

  • Yim, Ji-Young;Yim, Hyun-Seung;Park, Dae-Sung;Lee, Na-Kyung;Lee, Na-Kyung
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.1
    • /
    • pp.37-45
    • /
    • 2016
  • The purpose of this study was to assess the intra-rater, inter-rater and test-retest reliability and validity of frontal plane lower extremity alignment estimated from a rasterstereographic method using ABW-Mapper. Eighteen subjects participated in this study. The S angle (stereographic angle-frontal plane lower extremity alignment estimated from a rasterstereographic method) in standing was measured throughout the two sessions with one week interval by two different readers. In the first session, a reader measured S angle twice per subject with a short break in-between. The Q-angle (quadriceps angle) was measured using a standard goniometer from a photography taken through digital camera with the participant standing in the same position as in the S angle measurement. The HKA(hip-knee-ankle) angle was measured from a computer based digital radiograph with the computerized measurement software. Reliability was tested using intraclass correlation coefficients(ICC). Validity was tested using a Pearson's correlation coefficient. Excellent intra-rater(ICC=0.956~0.974), inter-rater(ICC=0.962), test-retest reliability (ICC=0.945) were demonstrated. There were strong negative correlations between S angle and Q-angle (r=-0.739), and between S angle and HKA angle (r=-0.702). Therefore, the S angle measured using a rasterstereographic mapper may be used to as a preliminary or supplementary tool to evaluate and study LE alignment in the frontal plane in relation to HKA angle or Q-angle.

Study on function evaluation tools for stroke patients (뇌졸중(腦卒中) 환자(患者)의 기능평가방법(機能評價方法)에 대(對)한 연구(硏究))

  • Ko, Seong-Gyu;Ko, Chang-Nam;Chox, Ki-Ho;Kim, Young-Suk;Bae, Hyung-Sup;Lee, Kyung-Sup
    • The Journal of Korean Medicine
    • /
    • v.17 no.1 s.31
    • /
    • pp.48-83
    • /
    • 1996
  • Our conclusions for function evaluation tools of Stroke patients are as follows. 1. Evaluating tools of Activities of Daily Living, Katz Index, Barthel Index, Modified Barthel Index have high validity and reliability because of ease of measuring, high accuracy, consistency, sensitivity and sufficient stastistics, but they mainly measure motor function except sense, mentation, language, and social conception. Therefore cerebrovascular disease and brain injury in trauma patients with lacked acknowledgement and sensation, we are not able to apply these tools. 2. PULSES Profile is a useful scale for measuring the patient's over-all status, upper and lower limb functions, sensory components, excretary functions, and intellectual and emotional adaptabilities. It is recognized as a good, useful tool to evaluate patient's whole function. 3. Motor Assessment Scale was designed to measure the progress of stroke patients. The scale was supplemented with upper arm function items. We believe that the Motor Assessment Scale could be a useful evaluation tool with inter-rater reliability ,test-retest reliability. 4. The existing evaluation tools, Katz Index, Barthel Index, Modified Barthel Index, PULSES Profile, Motor Assessment Scale, mainly measured the rehabilitational motor function of sequela of cerebrovascular patients. On the other hand CNS & INH stroke scale can measure cerebrovascular disease patient's neurologic deficits and over-all stautus, which are recognition ability, speech status, motor function, sensory function, activities of daily living. Those scales have been recognized as useful tools to measure function of cerebrovascular disease patients and have increased in use. 5. Every function evaluation tool was recognized to have some validity and inter-rater, test-retest reliability in items of each evaluation tool and total scores of each evaluation tools, but it is thought that none of these scales have been fully validated and proved reliable. Therefore afterward, the development of a highly reliable rating system may best be accomplished by a careful comparison of several tools, using the same patients and the same observers in order to choose the most reliable items from each. 6. Ideal evaluation tools must have the following conditions; (1) It should show the objective functional statues at the same time. (2) It should be repeated consecutively to know changed function status. (3) It should be easy to observe the treatment program. (4) It should have the same result with another rater to help rater exchange information with treatment team members. (5) It should be practical and simple. (6) The patient should not suffer from the observer.

  • PDF

Measuring Quality of Life in Cerebral Palsy Children According to the Severity Using the Visual Analogue Scale, Time Trade-Off, and EQ-5D-Y Proxy (뇌성마비 환아 중증도별 시각화척도, 시간교환법, EQ-5D-Y Proxy를 이용한 삶의 질 측정)

  • Lee, Go-Eun;Kim, Nam Kwen;Yun, Young Ju;Wang, Hye Min;Kim, Jeong Hun;Lee, Dong Hyo
    • Journal of Oriental Neuropsychiatry
    • /
    • v.28 no.2
    • /
    • pp.49-59
    • /
    • 2017
  • Objectives: To measure the quality of life in patients according to virtual cerebral palsy severity by using the Korean version of EQ-5D-Y proxy, Visual Analogue Scale (VAS), and Time Trade-Off method (TTO). Methods: The study was conducted in parents of children and adolescents aged 4 to 15 years in Seoul. We analyzed the difference in the utility value according to five levels of cerebral palsy severity in the Gross Motor Function Classification System (GMFCS) and test-retest reliability. Results: 1. There were significant differences in VAS, TTO, and EQ-5D-Y proxy according to the cerebral palsy severity (p<.001). 2. VAS was significantly different according to the respondent's visit to the medical institution, the presence of disease in the respondent, a visit to the child's medical institution, the age of the child, and the sex of the child. The value of TTO was significantly different according to the respondent's visit to the medical institution, respondent's sex, and the age of the child. Also, EQ-5D-Y proxy was significantly different according to the age of the child. 3. Intraclass correlation coefficient values were more than 0.6 for both VAS and TTO at all stages. But for the EQ-5D-Y proxy, the value was less than 0.6 at all stages. Conclusions: The quality of life assessment using EQ-5D-Y proxy showed significant differences in the severity of cerebral palsy. However, large-scale studies using EQ-5D-Y proxy are needed because of low test-retest reliability.

The Development of Physical Functioning Scale for Community-Dwelling Older Persons (지역사회 노인의 신체기능 평가도구 개발)

  • Lee, Kyung-Jong;Han, Geun-Shik;Yoon, Soo-Jin;Lee, Yeon-Kyung;Kim, Chan-Ho;Kim, Jeong-Lim;Lee, Yun-Hwan
    • Journal of Preventive Medicine and Public Health
    • /
    • v.35 no.4
    • /
    • pp.359-374
    • /
    • 2002
  • Objectives : To develop a physical functioning instrument for older adults living in the community. Methods : A representative sample of 979 people aged 65 years or over were interviewed in-person. Of these, 199 people also completed a detailed in-hospital examination. The scale items were selected based on the frequency of endorsement, along with the item-total and inter-item correlations. The associations of the scale with their physical performance and clinical examination were analyzed to evaluate the criterion-related validity. Construct validity was assessed using factor analysis, and internal consistency through Cronbach's alpha and item-total correlations. Test-retest reliability was measured by agreement between the household survey and the repeat survey at the in-hospital examination. Results : Initially, 23 items on the level of difficulty, ranging from no difficulty to an inability to complete a task, with the specific mobility and self-care tasks were included. Those with a high frequency of endorsement and a low inter-item or item-total correlations were excluded, resulting in a 10-item Physical Functioning (PT) scale. Equal weights were given to each item and a summated score was calculated. Significant associations were found between the PF scores and the physical performance, surrey and clinical data. The scale revealed a 2-factor (mobility and self-care) structure. Cronbach's alpha was 0.92 and the item-total correlations were in the 0.63 to 0.78 range. Pearson's correlations for the test-retest ranged between 0.56 and 0.61. Conclusions : The newly developed Physical Functioning (PF) scale showed good psychometric properties in older people. Further work, however, is needed to improve its sensitivity to discriminate higher levels of functioning, in addition to assessing its predictive value in detecting changes in health.

Usefulness of Comorbidity Indices in Operative Gastric Cancer Cases (위암 수술 환자의 건강결과 측정을 위한 동반상병 측정도구의 유용성 연구)

  • Hwang, Se-Min;Yoon, Seok-Jun;Ahn, Hyeong-Sik;An, Hyong-Gin;Kim, Sang-Hoo;Kyeong, Min-Ho;Lee, Eun-Kyoung
    • Journal of Preventive Medicine and Public Health
    • /
    • v.42 no.1
    • /
    • pp.49-58
    • /
    • 2009
  • Objectives : The purpose of the current study was to evaluate the usefulness of the following four comorbidity indices in gastric cancer patients who underwent surgery: Charlson Comorbidity Index(CCI), Cumulative Illness rating scale(CIRS), Index of Co-existent Disease(ICED), and Kaplan-Feinstein Scale(KFS). Methods : The study subjects were 614 adults who underwent surgery for gastric cancer at K hospital between 2005 and 2007. We examined the test-retest and inter-rater reliability of 4 comorbidity indices for 50 patients. Reliability was evaluated with Spearman rho coefficients for CCI and CIRS, while Kappa values were used for the ICED and KFS indices. Logistic regression was used to determine how these comorbidity indices affected unplanned readmission and death. Multiple regression was used for determining if the comorbidity indices affected length of stay and hospital costs. Results : The test-retest reliability of CCI and CIRS was substantial(Spearman rho=0.746 and 0.775, respectively), while for ICED and KFS was moderate(Kappa=0.476 and 0.504, respectively). The inter-rater reliability of the CCI, CIRS, and ICED was moderate(Spearman rho=0.580 and 0.668, and Kappa=0.433, respectively), but for KFS was fair(Kappa=0.383). According to the results from logistic regression, unplanned readmissions and deaths were not significantly different between the comorbidity index scores. But, according to the results from multiple linear regression, the CIRS group showed a significantly increased length of hospital stay(p<0.01). Additionally, CCI showed a significant association with increased hospital costs (p<0.01). Conclusions : This study suggests that the CCI index may be useful in the estimation of comorbidities associated with hospital costs, while the CIRS index may be useful where estimatation of comorbiditie associated with the length of hospital stay are concerned.