• 제목/요약/키워드: Test-Retest

검색결과 442건 처리시간 0.028초

보건소 이미지 척도 개발 (Development of Public Health Center Image Scale)

  • 이인영;김은미;배상수
    • 보건행정학회지
    • /
    • 제23권4호
    • /
    • pp.415-426
    • /
    • 2013
  • Background: This study was aim to identify the specific words and to develop the scale for the public health center (PHC) image. Methods: We collected 824 words from the previous studies and by open questions and reduced them by 77 words, then which were rated properly by 355 citizens of Seoul. We examined explanatory factor analysis for 69 words, and examined content validity test and confirmatory factor analysis (CFA) for the image structures (4 factors and 16 words). And then we developed the image questionnaire using them through council. We conducted a survey and retested the PHC image scales as the measuring tool targeting 2,000 persons, and compared the inexperience and experience persons for PHC usage. Results: The image structures were consisted of 4 factors and 16 words such as 'trustworthiness' (warm, exemplary, faithful, service-mindedness, beneficial to health), 'fairness' (honesty, clear, consistent, ruled), 'development possibility' (changing, goal-directed, developmental, propulsive), and 'flexibility' (not authoritative, not perfunctory, not rigid) in total. Cronbach's ${\alpha}$ values of all factors were above 0.7. As a result of CFA, model fit indexes yielded satisfactory results (root mean square error of approximation [RMSEA] 0.049, goodness of fit index [GFI] 0.937, and adjusted goodness of fit index [AGFI] 0.912). According to the result of retest for measuring tool by using other samples, Cronbach's ${\alpha}$ values were above 0.8, and model fit indexes yielded satisfactory results (RMSEA 0.059, GFI 0.952, AGFI 0.933). RMSEAs of the inexperiences and the experiences were each 0.59, 0.68. Conclusion: A reliable, valid, and generalizable scale was created for PHC image.

한국판 공포-회피 반응 설문지의 신뢰도와 타당도 (Reliability and Validity of the Korean Version of the Fear-Avoidance Beliefs Questionnaire)

  • 주명규;김택연;김진택;김선엽
    • 한국전문물리치료학회지
    • /
    • 제16권2호
    • /
    • pp.24-30
    • /
    • 2009
  • The purpose of this study was to determine the reliability and validity of the fear-avoidance beliefs questionnaire (FABQ) in assessing Korean patients with low back pain. We performed translation and cross-cultural adaptation of the questionnaire and enrolled 52 patients (18 males and 34 females) with low back pain. The subjects completed a standardized self-administered questionnaire that included the FABQ assessment along with evaluations for the visual analogue scale (VAS), Oswestry disability index (ODI), self-rating anxiety scale (SAS), and Beck depression inventory-Korean version (K-BDI). The reliability of the obtained data was determined by evaluating the internal consistency on the basis of the intraclass correlation coefficient (ICC) and the Cronbach's alpha values, while the validity of the data was examined by correlating the FABQ scores to the VAS, ODI, SAS, and K-BDI scores. The translated versions of the FABQ showed good test-retest reliability: ICC (3, 1)=.90 (FABQ for physical activity) and .97 (FABQ for work) these values were statistically significant (p<.01). The Cronbach's alpha value for FABQ was .90 (p<.01). FABQ moderately correlated with pain, disability, anxiety, and depression (p<.01). The results of this study indicate that the Korean version of the FABQ is a reliable and valid instrument for measuring fear-avoidance beliefs in Korean patients with low back pain.

  • PDF

경통 환자들을 위한 Neck Pain and Disability Scale의 신뢰도 연구 (Reliability of the Neck Pain and Disability Scale in Neck Pain Patients)

  • 신원섭;이은우;정경심;이석민;정이정
    • 한국전문물리치료학회지
    • /
    • 제15권1호
    • /
    • pp.77-85
    • /
    • 2008
  • The self-report measure is a useful tool for evaluating self-recognized disability and difficulty in daily living activities. Although many studies and clinics used the Neck Pain and Disability Scale (NPDS) for measuring neck pain and functional impairment, there has not been much adaptation of this for use with Korean patients. The purpose of this study was to establish the reliability and validity of NPDS among Korean neck pain patients. Fifty-five subjects (32 males, 23 females) with neck pain enrolled in this study. They completed standardized self-administered questionnaires. The NPDS measures pain intensity; its interference with vocational, emotional, recreational, social, and functional aspects of living; and the presence and extent of associated factors. Reliability was determined by the intraclass correlation coefficient (ICC) and Cronbach's alpha for internal consistency. Validity was examined by correlating the NPDS scores to the Visual Analog Scale (VAS) score. The test-retest reliability of the translated versions of the NPDS was good ICC (2,1)=.86 (95%CI .76~.92). Cronbach's alpha value for NPDS was found to be .93, and this was statistically significant (p<.05). The criterion-related validity coefficient was .79 (p<.Oll. We conclude that the Korean version of NPDS has been shown to be a reliable and valid instrument for the assessment of neck pain. Successful linguistic and cultural translation will admit appropriate cross-cultural comparison for clinical analysis. Therefore, this study can be expected to be used as an adequate evaluation scale for neck pain related studies and treatments.

  • PDF

The Validity and Reliability of the Second Korean Working Conditions Survey

  • Kim, Young Sun;Rhee, Kyung Yong;Oh, Min Jung;Park, Jungsun
    • Safety and Health at Work
    • /
    • 제4권2호
    • /
    • pp.111-116
    • /
    • 2013
  • Background: The aim of this study was to evaluate the quality of the Second Korean Working Conditions Survey (KWCS), focusing on its validity and reliability. Methods: The external validity was evaluated by the assessment of sampling procedures and the response rate, in order to investigate the representativeness of the sample. The content validity was evaluated by the assessment of the development of the questionnaire, and the consistency of questions for the selected construct. The test-retest method was used to evaluate the reliability by means of a phone call survey of 30% of the respondents, who were randomly selected. The respondents' satisfaction regarding the survey procedures and interview time were analyzed to evaluate the quality of survey data. Results: The external validity was assured by an acceptable sampling procedure, rigid multi-stage stratified cluster random sampling. The content validity was also guaranteed by a reasonable procedure for the development of the questionnaire with a pretest. The internal consistency of the questions for work autonomy was maintained, with 0.738 of Cronbach's alpha. The response rate of 36% was lower than that of the European Working Conditions Survey (EWCS), with a contact rate of 66%, compared to 76% for the EWCS. The matching rates of the five retested questions were more than 98% reliable. Conclusion: The quality of the second KWCS was assured by the high external and content validity and reliability. The rigid sampling procedure and development of the questionnaire contributed to quality assurance. The high level of reliability may be guaranteed by the sophisticated field survey procedures and the development of a technical manual for interviewers. The technical strategies for a high response rate should be developed for future surveys.

지면반력장비의 정밀성, 신뢰도와 장비설치.사용 환경의 영향 (Accuracy and Reliability of Ground Reaction Force System and Effect of Force Platform Mounting and Environment)

  • 박영훈;염창홍;손승;서국웅;김의환;김태완
    • 한국운동역학회지
    • /
    • 제17권1호
    • /
    • pp.1-8
    • /
    • 2007
  • Ground reaction force (GRF) measures are one of the most commonly used in biomechanical study. GRF system is very useful educational tool to explain and demonstrate the Newton's law of universal gravitation and laws of motion as well. However, accuracy, intra- and inter- force platform measures' consistency, reliability, noise, and the effect of platform mounting to GRF measures were not clearly viewed. The aim of this study was to examine the above. GRFs of a plastic dummy and two subjects' quiet upright standing were collected at four university laboratories eight force platforms. The types of platforms, analysis programs, and platform set-up were various. Three 100s-trials were conducted with sampling frequency of 100 Hz. First two trials' vertical component of GRFs, Fz, and CoP sway ranges of mid-60s-portion of 100s trials were analyzed by the paired t-tests and one-way ANOVA. Six of eight platforms' 1st and 2nd trial dummy Fz were statistically different (p<.05) and all platforms ICC were poor (<.28). Fz of the two platforms in every four laboratories were statistically different (p<.05). There were white noises and/or very distinctive noises at specific frequency ranges in all Fz measures. 5 Hz low-pass filtering made clear the Fz differences. CoP ranges of dummy were less than 0.5 cm and the best was 0.02 cm. This CoP range finding agrees with previous results suggests the importance of force platform mounting and A/D card resolution.

정상성인에 대한 정적 및 동적 자세균형제어의 정량적 분석 (A Quantitative Assissment of Static ann Dynamic Postural Sway in Normal Adults)

  • 신용일;김연희;김남균
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권2호
    • /
    • pp.157-166
    • /
    • 1997
  • Postural balancing in human is known to be maintained by the complex mechanism coupled with cerebellum, equilibrium organ of ear, proprioception and other various organs. We developed a Computerized Balance Evaluation and Training system(COBET system) to evaluate postural control and to rehabilitate geriatrics and disabled patient. In addition, 55 normal adult were tested to investigate the influencing factors on balancing posture. For the analysis of static postural sway, areas of the moving center of pressure were calculated under 8 different positions of subjects. And subjects were also asked to follow the visual targets on monitor for the evaluation of the dynamic postural sway. In comparison of the first and the second sets of tests, there was test-retest reliability($\textit{p}$< 0.05). The controllability of the static pmtwn sway was decreased as the ages of subjects increase. When the ages of subject are over 60, the controllability was significantly decrease4 The dynamic postural sway was significantly greater in the age groups of 7th and 8th decade than the younger groups. It is concluded that COBET system is a reliable system in the evaluation of postural sway. The COBET system is considered to be a valuable training modality for the disabled patients as well as the elderly.

  • PDF

Development of the Korean Form of the Premonitory Urge for Tics Scale: A Reliability and Validity Study

  • Kim, Mira;Chung, Sang-Keun;Yang, Jong-Chul;Park, Jong-Il;Nam, Seok Hyun;Park, Tae Won
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • 제31권3호
    • /
    • pp.146-153
    • /
    • 2020
  • Objectives: This study aimed to evaluate the reliability and validity of the Korean Form of the Premonitory Urge for Tics Scale (K-PUTS). Methods: Thirty-eight patients with Tourette's disorder who visited Jeonbuk National University Hospital were assessed with the K-PUTS. Together with the PUTS, the Yale Global Tic Severity Scale (YGTSS), the Children's Yale-Brown Obsessive Compulsive Scale (CY-BOCS), the attention-deficit/hyperactivity disorder (ADHD) rating scale (ARS), and the Adult ADHD Self-Report Scale (ASRS) were implemented to evaluate concurrent and discriminant validity. Results: The internal consistency of items on the PUTS was high, with a Cronbach's α of 0.79. The test-retest reliability of the PUTS, which was administered at 2 weeks to 2 months intervals, showed high reliability with a Pearson correlation coefficient of 0.60. There was a significant positive correlation between the overall PUTS score and the YGTSS score, showing concurrent validity. There was no correlation between the PUTS, CY-BOCS, and ASRS scores, demonstrating the discriminant validity of the PUTS. Factor analysis for construct validity revealed three factors: "presumed functional relationship between the tic and the urge to tic," "the quality of the premonitory urge," and "just right phenomena." Conclusion: The results of this study indicate that the K-PUTS is a reliable and valid scale for rating premonitory urge of tics.

한국판 영적간호역량 측정도구의 타당도와 신뢰도 (Validity and Reliability of Korean Version of the Spiritual Care Competence Scale)

  • 정미자;박영례;은영
    • 대한간호학회지
    • /
    • 제46권6호
    • /
    • pp.871-880
    • /
    • 2016
  • Purpose: The aim of this study was to examine the validity and reliability of the Korean Version of the Spiritual Care Competence Scale (K-SCCS). Methods: A cross-sectional study design was used. The K-SCCS consisted of 26 questions to measure spiritual care competence of nurses. Participants, 228 nurses who had more than 3 years'experience as a nurse, completed the survey. Confirmatory factor analysis was used to examine the construct validity and correlations of K-SCCS and spiritual well-being (SWB) were used to examine the criterion validity of K-SCCS. Cronbach's alpha was used to test internal consistency. Results: The construct and the criterion-related validity of K-SCCS were supported as measures of spiritual care competence. Cronbach's alpha was .95. Factor loadings of the 26 questions ranged from .60 to .96. Construct validity of K-SCCS was verified by confirmatory factor analysis (RMSEA=.08, CFI=.90, NFI=.85). Criterion validity compared to the SWB showed significant correlation (r=.44, p<.001). Conclusion: The findings suggest that K-SCCS serves as an appropriate measure of spiritual care competence with validity and reliability. However, further study is needed to retest the verification of the factor analysis related to factor 2 (professionalisation and improving the quality of spiritual care) and factor 3 (personal support and patient counseling). Therefore, we recommend using the total score without distinguishing subscales.

암 환자에서 우울증의 선별도구로서 단축형 에딘버러 우울증 척도의 한국 표준화 (The Standardization of the Korean Version of Brief Edinburgh Depression Scale as a Screening Tool for Depression in Cancer Patients)

  • 이정현;김태석;고윤호;윤수정;류인균;전태연;이철
    • 생물정신의학
    • /
    • 제16권2호
    • /
    • pp.112-120
    • /
    • 2009
  • Objectives : Depression is a common psychiatric disorder in cancer patients. The Brief Edinburgh Depression Scale(BEDS), which is an abbreviated version of the Edinburgh Depression Scale, may serve as a useful tool in screening for the depression in patients with the medical illnesses. This report investigated the reliability and validity of the Korean Version of the BEDS(K-BEDS) for the depression in cancer patients. Methods : One-hundred cancer patients were enrolled in this study. All subjects completed the K-BEDS, the Hospital Anxiety Depression Scale(HADS), and the Karnofsky Performance Status Scale(KPSS). Reliability, validity and Receiver Operating Characteristic(ROC) curve analysis measures were assessed. Results : The K-BEDS showed good internal consistency(Cronbach ${\alpha}$=0.77) and test-retest reliability(0.94, p<0.001). All item-total correlations were above 0.3. Also, it revealed moderate correlation with the depression subscale of the HADS(r=0.617), but no correlation with the KPSS. Exploratory factor analysis produced only one factor, accounting for 47.1% of the total variance. The most valid cutoff value to screen for depression was a total score of 5 on the K-BEDS, which showed sensitivity of 62.5% and specificity of 86.4% with a positive predictive value of 4.60 and a negative predictive value of 0.43.

  • PDF

정신분열병 환자의 한국어판 사회기능척도 개발 : 신뢰도 및 타당도 연구 (Development of the Korean Version of the Social Functioning Scale in the Schizophrenics : A Study on the Reliability and Validity)

  • 김철권;이지아
    • 생물정신의학
    • /
    • 제16권2호
    • /
    • pp.76-111
    • /
    • 2009
  • Objectives : The purpose of this study was to develop the Korean version of the Social Functioning Scale (KSFS) in the patients with schizophrenia. Methods : KSFS was administered to 90 schizophrenic patients and 80 their parents and 90 normal controls for examining the reliability and validity. Results : Data analysis showed statistically significant reliabilities and validities of KSFS. The test-retest reliability, rater vs. self-report reliability, and internal consistency for total scores of KSFS were 0.93, 0.44 and 0.94 respectively. Evidence for discriminant validity of KSFS comes from the results that the mean scores of schizophrenic patients were significantly higher than those of normal controls. Construct validity was assessed by calculating the 7 inter-areas correlations of the KSFS, and all areas were statistically significant. Significant correlations between the total scores of KSFS and those of SOFAS lend support for the concurrent validity of this instrument. Factor analyses were performed and two factors were extracted accounting for 63.7% of the variance. Sensitivity was assessed indirectly via the distribution and range of scores on the SFS. The normal control group showed a distribution around a higher mean with a moderate positive skew. Conclusion : KSFS was found to be a valid, reliable, and sensitive instrument which can be used to evaluate the degree of social functioning in the patients with schizophrenia.

  • PDF