• Title/Summary/Keyword: Test section

검색결과 3,087건 처리시간 0.028초

대학수학능력시험 수학(수리) 영역 변천사 (History of the College Scholastic Ability Test in Mathematics Section)

  • 전영주
    • 한국수학사학회지
    • /
    • 제26권2_3호
    • /
    • pp.177-195
    • /
    • 2013
  • 본 연구는 대학수학능력시험 수리(수학) 영역의 개념 및 성격을 살펴보고, 수리(수학) 영역의 20년 변천 과정을 도입기(1994~1996학년도), 조정기(1997~2004학년도), 발전기(2005~2011학년도), 전환기(2012학년도 이후)로 구분하여 시기별 변천 과정을 고찰한 후, 향후 수학 영역의 과제를 제시하였다.

차체구조용 박육부재의 단면형상변화에 따른 에너지흡수 특성 (Energy Absorbing Characteristics of Thin-Walled Members for Vehicles Having Various Section Shapes)

  • 차천석;정진오;이길성;백경윤;양인영
    • 한국정밀공학회지
    • /
    • 제20권10호
    • /
    • pp.177-182
    • /
    • 2003
  • The front-end side members of automobiles absorb most of the energy in a case of front-end collision. The front-end side members are required to have a high stiffness together with easiness to collapse sequentially to absorb more impact energy. The axial static collapse test (5mm/min) was conducted by using UTM for form different types of members which have different cross section shapes; single hat, single cap, double cap, and double hat. The single hat shaped section member has the typical standard section, which the double hat shape section has a symmetry in the center to have more stiffness. As a result of the test, the energy absorbing characteristic was analyzed for different section shapes. It turned out that the change of section shape influence the absorbing energy, the mean collapse load and the maximum collapse load, and the relation between the change of section shape and the collapse mode.

Effects of 4-week PNF Exercise Program on Activity, Posture, and Muscle Strength in a Patient with Abdominalis Weakness after Cesarean Section: A Single-Subject Study

  • Beom-Ryong Kim;Tae-Woo Kang;Seo-Yoon Park
    • The Journal of Korean Physical Therapy
    • /
    • 제36권1호
    • /
    • pp.1-8
    • /
    • 2024
  • Purpose: The purpose of this study was to determine the effect of proprioceptive neuromuscular facilitation (PNF) abdominal muscle strengthening exercise on the activity, posture, and body function of clients with abdominal muscle weakness after cesarean section. Methods: PNF abdominal muscle strengthening exercise was applied to one patient with abdominal muscle weakness after cesarean section. PNF abdominal muscle strengthening exercise was applied five times a week for four weeks. The 5-time supine-to-long sitting test (5-TSLST) and supine-to-stand test (SST) were used to measure activity, and the pelvis tilt angle test (PTAT) and anterior head translation test (AHTT) were used to measure posture. Body function was assessed using the transverse abdominis muscle strength test (TAMST), the internal oblique and external oblique muscle strength test (IOEOMST), and the rectus abdominis muscle strength test (RAMST). Results: Activity, posture, and body function were improved post-intervention. Conclusion: The study verified that PNF abdominal muscle strengthening exercises are effective when applied to patients with abdominal muscle weakness after cesarean section. The findings of this study provide useful data for future interventions in patients with abdominal muscle weakness after cesarean section.

차체구조용 박육단면부재의 단면형상변화에 따른 축압궤 특성에 관한 연구 (A Study on the Axial Collapse Characteristics of Thin-Walled Members for Vehicles on the Variation of Section Shapes)

  • 이길성;백경윤;차천석;정진오;양인영
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1549-1552
    • /
    • 2003
  • The front-end side members of automobiles absorb most of the energy in a front-end collision. The front-end side members are required to have a high stiffness together with easiness to collapse sequentially to absorb more impact energy. The axial static collapse test (5mm/mim) was conducted by using UTM with respect to the single hat shaped section members which are the standard section shape of the spot welded section members, to the single cap shaped section members, to the double cap shaped section members and to the double hat shaped section members whose section shape are changed in order to give more stiffness. As a result of test, the energy absorbing characteristic was analyzed for different section shapes. That is, it was analyzed that the change of section shape influenced the absorbing energy, the mean collapse load and the maximum collapse load, and that the relation between the change of section shape and the collapse mode.

  • PDF

Film Boiling Heat Transfer from Relatively Large Diameter Downward-facing Hemispheres

  • Kim Chan Soo;Suh Kune Y.;Park Goon Cherl;Lee Un Chul;Yoon Ho Jun
    • Nuclear Engineering and Technology
    • /
    • 제35권4호
    • /
    • pp.274-285
    • /
    • 2003
  • Film boiling heat transfer coefficients for a downward-facing hemispherical surface are measured from the quenching tests in DELTA (Downward-boiling Experimental Loop for Transient Analysis). Two test sections are made of copper to maintain Bi below 0.1. The outer diameters of the hemispheres are 120 mm and 294 mm, respectively. The thickness of both the test sections is 30 mm. The effect of diameter on film boiling heat transfer is quantified utilizing results obtained from the two test sections. The measured heat transfer coefficients for the test section with diameter 120 mm lie within the bounding values from the laminar film boiling analysis, while those for diameter 294 mm are found to be greater than the numerical results on account of the Helmholtz instability. There is little difference observed between the film boiling heat transfer coefficients measured from the two test sections. In addition, the higher thermal conductivity of copper results in the higher minimum heat flux in the tests. For the test section of diameter 120 mm, the Leidenfrost point is lower than that for the test section of diameter 294 mm. Destabilization of film boiling propagates radially inward for the 294 mm test section versus radially outward for the 120 mm Test Section.

FIV 시험루프의 유동기인 진동 신호분석 (Flow-Induced Vibration Signal Analysis of the FIV Test Loop)

  • 이강희;강흥석;윤경호;송기남
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.601-606
    • /
    • 2004
  • Vibration spectrums of the test loop according to flow conditions were analyzed in order to identify the sources of vibration at peak frequencies. While a flow condition of the sweep test was changed by varying pump rotational speed from 450 rpm to 1500 rpm by the step 150 rpm, midspan acceleration of the test section in width-direction and dynamic pressure perturbation in the test section were measured. Other sources of vibration due to the flow structure interactions, such as acoustic resonance, blade pulsing frequency and bellows wrinkles, were investigated. Pressure perturbation in the section and acoustic resonance due to branch pipe give major effects to the vibration of the test section in high frequency range of 1.5 kHz to 2.8 kHz.

  • PDF

고강도 PSC BEAM 교량의 휨거동 (Flexural Behavior of PSC Beam Using High Strength Concrete)

  • 정원기;이형준;이규정;윤석구;한승환;김기수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표대회 논문집(III)
    • /
    • pp.706-711
    • /
    • 1998
  • Structural tests of the PSC Beam bridge using high strength concrete, concrete compressive strength 700kg/$\textrm{cm}^2$, are conducted for the application including durability and serviceability of the bridge. Current design safety factors with respect to the jacking force and the service design load DB-24 are applied to the design of the bridge. Concrete compressive strength 700kg/$\textrm{cm}^2$, girder depth 2.3m, girder space 3.2m, span length 20m, and slab thickness 27cm are selected for the bridge test. The Bulb-Tee section of the girders is applied instead of I section because it is well known more stable to the longer span(40m). Static load test(4 beams) with composite and non-composite section, and fatigue load test(1 beams) with composite section are conducted. Crack moment, ultimate load, deflections with load steps, and strains of the beam section for those bridges are investigated. The structural test results of the bridges showed a good performance for a safety and a serviceability.

  • PDF

전산유동 해석을 이용한 수동의 유동 균질성 평가 (Estimation of Flow Uniformity in Water Tunnel by Using CFD Analysis)

  • 임영택;장조원;김문상
    • 한국항공운항학회지
    • /
    • 제12권3호
    • /
    • pp.13-24
    • /
    • 2004
  • It is easier to view flow visualization by using a water tunnel rather than a smoke wind tunnel because of low speed at same Reynolds number. Using a water tunnel also produces more definite flow visualization by the use of various color dyes. The flow uniformity in test section is very significant for accuracy of the test because most flow experiments elicit results through the installation of a model in uniform flow. The purpose of small-size desktop-type water tunnel is not to produce quantitative measurements, but rather to give a visualization of the fluid flow phenomenon. However, uniformity in the test section affects the accuracy of the results. Accordingly, this research estimates uniformity in a water tunnel test section by using the commercially available CFD code FLUENT. Results of the CFD analysis show that the flow uniformity of the test section is good.

  • PDF

상급종합병원의 예측 제왕절개분만율과 실제 제왕절개분만율의 격차 관련요인 (Factors on the Gap between Predicted Cesarean Section Rate and Real Cesarean Section Rate in Tertiary Hospitals)

  • 김윤미;김세영
    • 여성건강간호학회지
    • /
    • 제18권3호
    • /
    • pp.200-208
    • /
    • 2012
  • Purpose: This study was aimed to examine the gap between predicted cesarean section rate and real cesarean section rate and it's determining factors of 44 tertiary hospitals. Method: This study is a cross-sectional analysis using the data of 25,623 deliveries in 2009 drawn from homepage of Health Insurance Review and Assessment Service. Data were analyzed with t-test, F-test, Scheff$\acute{e}$ test, and logistic regression. Result: There were statistically significant differences in the gap of cesarean section rate (more gap indicates higher quality of delivery) by grade of nurse staffing and delivery cases. Hospitals with nurse staffing grade 1 to 2 had more possibility to be classified into higher grade in quality of delivery (OR 5.67, 95% CI 1.07-30.08). Also hospitals with over 500 delivery cases had more possibility be classified into higher grade in quality of delivery (OR 4.92, 95% CI 1.14-21.23, respectively). Conclusion: The finding suggests that grade of nurse staffing may influence the real cesarean section rate because nurses do a vital role to prevent unnecessary cesarean section. Further study is required to provide evidence that nurse staffing influence on patient outcome and cost-effectiveness in order to obtain adequate number of nursing staffs.

환기 초공동 실험을 위한 캐비테이션 터널 기포 포집부 연구 (Study on Bubble Collecting Section of Cavitation Tunnel for Ventilated Supercavitation Experiments)

  • 백부근;박일룡;김기섭;이건철;김민재;김경열
    • 대한조선학회논문집
    • /
    • 제53권4호
    • /
    • pp.300-306
    • /
    • 2016
  • The gas ventilated by supercavitation splits into smaller bubbles and follows the water passage of the cavitation tunnel. The bubbles quickly return to the test section by rather high speed flow, and interrupt the observation of the supercavitation. To secure clear observation in the test section, the bubble collecting section(settling chamber) of large volume is prepared to collect bubbles in the water passage ahead of the test section. The bubble collecting section should provide enough buoyancy effect to the bubbles for proper bubble collecting. However, rather high-speed oncoming flow produces non-uniform velocity distribution and deteriorates buoyancy effect in the bubble collecting section. In the present study, the bubble collecting space and three porous plates are designed and analyzed through numerical methods, and the bubble collecting function is experimentally validated by 1/10-scaled model in terms of the formation of uniformly low velocity distribution in the bubble collecting section.