• Title/Summary/Keyword: Test module

Search Result 1,585, Processing Time 0.029 seconds

Hail Impact Analysis of Photovoltaic Module using IEC Test (IEC 우박시험에 대한 태양광모듈 충돌 해석)

  • Park, Jung-Jae;Park, Chi-Yong;Ryu, Jae-Woong
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.4
    • /
    • pp.23-33
    • /
    • 2020
  • The loss in photovoltaic power due to hailstorms has been highlighted as a major issue in the sustained growth of the PV power plant industry. This study investigates the safety of a solar module by conducting a numerical analysis of a hail test according to the IEC 61215 standard. Our study aims to elucidate the detailed behavior between the ice and solar modules and the micro-cracks forming on solar modules during hailstorms. To analyze the impact of hail, we used the ANSYS AUTODYN software to evaluate the impact characteristics on a solar module with different front glass thicknesses. The simulations show that a solar module with a glass thickness of 4.0 mm results in excellent durability against hail. The results indicate the feasibility of using simulations to analyze and predict micro-cracks on solar modules tailored to various conditions, which can be used to develop new solar modules.

Leakage Rates Measurement System Development of NPP Primary Containment using Wireless Data Communication Method (원전 격납건물 누설시험용 무선데이터전송을 적용한 시험장치 개발)

  • Ryu, Jae-Kyu;Sohn, Chang-Ho;Hwang, Hee-Jung;Kim, Gun-Soo;Choi, Kyong-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.916-919
    • /
    • 2003
  • In this paper, we deal with a development of measurement system to apply the leakage rates test of primary containment in nuclear power plant. The measurement test about leakage rates in primary containment is one sort of test to prove safety of nuclear power plant. The parameters which are measured to calculate leakage rates are drybulb temperature, dew point temperature(or relative humidity), absolute pressure and flow. Overall, the measurement system consists of sensor module for data acquisition of the parameters, transfer module for wireless data communication and control module to control system and to calculate leakage rates. Because existing measurement systems are difficult to set in field, we pursued convenience of use, we applied wireless data communication and individual form module using battery. We also changed for the better in confidence. Recently, we are developing a drybulb temperature and a dew point temperature sensor module. We describe about function of developed measurement system, its standard and an plan for verification of measurement system.

  • PDF

Design and Implementation of Hand-Held Inspection Device for High Performance Mobile TFT LCD/OLED Module (고성능 모바일 TFT LCD/OLED 모듈을 위한 헨드헬드 검사장비 설계 및 구현)

  • Moon, Seung-Jin;Kim, Hong-Kyu
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.6B
    • /
    • pp.630-640
    • /
    • 2009
  • The thesis suggests hand-held equipment to overhaul for mobile TFT LCD/OLED module of high-performance. The established module equipment to overhaul could distinguish outputting video data to module for distinguishing flicker, but it is impossible with low system. In this thesis, supporting system could check the various supplement functions from bringing equipment to overhaul without changing design of FPGA or H/W the module various size for equipment to overhaul for module of high-performance coincidently. The system includes hand-held equipment to overhaul, test software embedded and software a base personal computer and have designed to output, save, and certify all contents of module test of hand-held equipment to overhaul to interface universal serial bus. Setting up 9 items that represent for efficient verification of the proposed system have been possible confirmation with TFT LCD/OLED module of high-performance, establishment scan time, creation gamma, changing register, supporting interface, and multi inch modules.

An Accelerated Life Test of Thermoelectric Module for Water Purifier (정수기 적용 열전모듈의 가속수명시험)

  • Moon, Ji Seob;Lee, Sung Min;Jeong, Seon Yong;Kim, Myung Soo
    • Journal of Applied Reliability
    • /
    • v.14 no.1
    • /
    • pp.21-28
    • /
    • 2014
  • This paper presents an accelerated life test to estimate the lifetime of thermoelectric module for home water purifier. Clamping force and thermal cycle are selected as accelerating variables through the technical review about failure mechanism. It is assumed that its lifetime follows weibull distribution. The relationship, acceleration factor, and BP life at design condition are estimated by analyzing the accelerated life test data.

A Design of a Simulation Platform to Test PRT Vehicle Operational Control Algorithms Using On-board Embedded Process Board (차상용 임베디드 제어보드를 이용한 PRT 차량 운행제어 알고리즘 시험을 위한 플랫폼 설계)

  • Lee, Jun-Ho;Jeong, Rac-Gyo;Kim, Yong-Kyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.1962-1967
    • /
    • 2009
  • This paper deals with a design of a platform to simulate PRT vehicle operational control algorithms using on-board embedded process board. The configuration of the platform is composed of the central control module, the station control module, man-machine interface and monitoring module. Since PRT system needs inherently very reliable vehicle operational control algorithm in order to avoid the impact between vehicles, it is very important to construct a simulation platform to test a designed vehicle operational control algorithm during the development process For the test of the proposed platform a path of the each moving vehicle is predefined in the central control system before the dispatch order is given to the vehicle. The simulation results show the effectiveness of the proposed simulation platform for test and evaluation of the PRT operational control algorithms.

Module level EMC verification method for replacement items in nuclear power plant

  • Hee-Taek Lim;Moon-Gi Min;Hyun-Ki Kim;Gwang-Hyun Lee;Chae-Hyun Yang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2407-2418
    • /
    • 2023
  • Internal replaceable electronic module substitutions can impact EMC (ElectroMagnetic Compatibility) qualification testing and results if EMC testing is conducted at the cabinet level. The impact of component substitutions on EMC qualification results therefore should be evaluated. If a qualitative evaluation is not adequate to ensure that the modified product will not impact the cabinet level EMC qualification results, a new qualification testing should be conducted. Component level retesting should be conducted under electromagnetically equivalent conditions with the cabinet level test. This paper analyzes the propagation of conducted susceptibility test waveforms in a representative cabinet and evaluates the impact of component substitutions on cabinet level EMC qualification results according to the location of the replacement items. A guideline for a qualitative evaluation of the impact of component substitutions is described based on the propagation of the conducted susceptibility test waveforms. A module level test method is also described based on an analysis of the shielding effectiveness of the cabinet.

A Review on the Failure Mechanism for Crystalline Silicon PV Module (결정계 PV 모듈에 대한 고장 메커니즘 검토)

  • Kim, Jeong-Yeon;Kim, Ju-Hee;Chan, Sung-Il;Lim, Dong-Gun;Kim, Yang-Seob
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.6
    • /
    • pp.343-349
    • /
    • 2014
  • It is summarized that potential causes of performance degradations and failure mechanisms of crystalline silicon photovoltaic (PV) modules installed in Middle East area. In addition, we also reviewed current PV module qualification test (IEC 61215) and the methods for detection of wear-out fault. The failure of PV modules in the extreme environmental conditions such as deserts is mainly due to high temperature, humidity, and dust storms. In particular, cementation phenomenon caused by combination of sand and moisture leads to rapid degradation in the performance of PV modules. In order to evaluate and guarantee the long term reliability of PV modules, specific qualification tests such as sand dust test, salt mist test and potential induce degradation test considering operating environment of PV module should be carried out.

A study on the vowel extraction from the word using the neural network (신경망을 이용한 단어에서 모음추출에 관한 연구)

  • 이택준;김윤중
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 2003.11a
    • /
    • pp.721-727
    • /
    • 2003
  • This study designed and implemented a system to extract of vowel from a word. The system is comprised of a voice feature extraction module and a neutral network module. The voice feature extraction module use a LPC(Linear Prediction Coefficient) model to extract a voice feature from a word. The neutral network module is comprised of a learning module and voice recognition module. The learning module sets up a learning pattern and builds up a neutral network to learn. Using the information of a learned neutral network, a voice recognition module extracts a vowel from a word. A neutral network was made to learn selected vowels(a, eo, o, e, i) to test the performance of a implemented vowel extraction recognition machine. Through this experiment, could confirm that speech recognition module extract of vowel from 4 words.

  • PDF

Degradation Behavior of Eutectic and Pb-free Solder Plated Ribbon in Crystalline Silicon Photovoltaic Module (유무연 용융도금 리본에 따른 결정질 실리콘 태양전지 모듈 열화거동)

  • Kim, Ju-Hee;Kim, A Yong;Park, Nochang;Ha, Jeong Won;Lee, Sang Guon;Hong, Won Sik
    • Journal of Welding and Joining
    • /
    • v.32 no.6
    • /
    • pp.75-81
    • /
    • 2014
  • Usage of heavy metal element (Pb, Hg and Cd etc.) in electronic devices have been restricted due to the environmental banning of the European Union, such as WEEE and RoHS. Therefore, it is needed to develop the Pb-free solder plated ribbon in photovoltaic (PV) module. This study described that degradation characteristics of PV module under damp heat (DH, $85^{\circ}C$ and 85% R.H.) condition test for 1,000 h. Solar cell ribbons were utilized to hot dipping plate with Pb-free solder alloys. Two types of Pb-free solder plated ribbons, Sn-3.0Ag-0.5Cu (SAC305) and Sn-48Bi-2Ag, and an electroless Sn-40Pb solder hot dipping plated ribbon as a reference sample were prepared to evaluate degradation characteristics. To detect the degradation of PV module with the eutectic and Pb-free solder plated ribbons, I-V curve, electro-luminescence (EL) and cross-sectional SEM analysis were carried out. DH test results show that the reason of maximum power (Pm) drop was mainly due to the decrease fill factor (FF). It was attributed to the crack or oxidation of interface between the cell and the ribbon. Among PV modules with the eutectic and Pb-free solder plated ribbon, the PV module with SAC305 ribbon relatively showed higher stability after DH test than the case of PV module with Sn-40Pb and Sn-48Bi-2Ag solder plated ribbons.

The Effect Development and Application of ASI Module using Science Notebooks in Open Inquiry Activity : Focused on Earth and Space (자유 탐구에서 과학 탐구 노트를 활용한 ASI 모듈 개발 및 적용 효과 -지구와 우주 영역을 중심으로-)

  • Lee, Sang-Gyun;Kim, Soon-Shik;Choe, Seong-Bong
    • Journal of Korean Elementary Science Education
    • /
    • v.31 no.1
    • /
    • pp.40-56
    • /
    • 2012
  • The purpose of this study was to understand the teaching effects after conducting ASI module in the open inquiry activities of the elementary science class. in order to understand the effects of ASI(Authentic Scientific Inquiry) module application using science research notes in open inquiry activities to students' science research ability. The results of this study were as follow. First, the after test results were covariance-analyzed to be the effects to science process skills were statistically significant in 0.5 significance level. Second, in the covariance analysis of the after test of the study group and the comparative group, the effects to scientific creative problem solving skills were statistically significant in 0.5 significance level. Third, the covariance analysis of the after test in the effects of ASI module application using science notebooks to students' scientific attitude revealed that the two groups' average difference was statistically significant in 0.5 significance level. In conclusion, application of the ASI module using science notebooks had a positive effect on improvements of students' science process skills, science creative problem solving ability and scientific attitude. Therefore, the ASI module using science notebooks is hopefully to be provided as an effective instructive strategy in the open inquiry activities courses in school in the future.