• Title/Summary/Keyword: Test methods

Search Result 27,194, Processing Time 0.055 seconds

Comparison of LAL Test with Pyrogen Test (발열성 물질시험과 세균 내독소 시험의 비교 연구)

  • 이유경;강윤숙;백선영;김용관;신광훈;민홍기
    • YAKHAK HOEJI
    • /
    • v.43 no.5
    • /
    • pp.606-613
    • /
    • 1999
  • To survey the possibility of replacing the pyrogen test with Limulus Amebocyte Lysate(LAL) test and to find out a standard methods suitable to our blood products made in Korea, 100 samples of 20% human serum albumin were tested by commercial LAL test kits and results of those were compared with rabbit pyrogen test. The LAL test is used both dinetic-chromogenically and kinetic-turbidimetrically. Both methods equally showed broad detection range (5.0~0.005 EU/ml), excellent sensitivity ($\geq$ 0.005 EU/ml) and predominant recovery rate within valid dilution range, but kinetic-turbidimetric method seemed to be more reproducible than kinetic-chromogenic method(kinetic-chromogenic method : S.D. = 15.88, kinetic-turbidimetric method : S.D. = 8.12). After heating the sample at 75$^{\circ}C$ for 15 min, the results showed a little elevated recovery rate with both methods. After performing the test on 100 albumin samples with both kits, the results were analysed using the USP standard (1.33 EU/ml). 7% of samples in kinetic-chromogenic methods and 1% of samples in kinetic-turbidimetric method exceeded the limit of endotoxin levels regulated for blood products in USA. Because this phenomenon was not observed in both methods at the same time and both methods have high sensitivity ($\geq$0.005 EU/ml), these results seemed to depend on nonspecific reaction. Considering its sensitivity and reproducibility, we could assure that LAL test is proper to detecting pyrogenic with good sensitivity.

  • PDF

Performance Evaluation of NDE Methods in Condition Assessment of Structural Elements (구조물 진단에 있어 비파괴 시험법의 성능평가)

  • Shim, Hyung Seop;Kang, Bo Soon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.3
    • /
    • pp.167-175
    • /
    • 2007
  • The relations between data from test methods and conditions in structural elements are considered. NDE(Nondestructive Evaluation) methods are joint application of a test and a basis for interpretation of data obtained in the test. Correct assessments of conditions of elements depend on the inaccuracy and variability in the test data and on the uncertainty of correlations between attributes(what is measured) and conditions(what is sought in the inspection). A full description of the performance of NDE methods considers the relation of test data to condition of elements. The quality of the test data itself is important, but equally important is the interpretation that occurs after the test. To make the decision of the performance of NDE methods, this paper presents mathematical basis to measure the reliability of NDE methods.

Outlier Tests in Sample Surveys

  • Namkyung, Pyong;Lee, Joon Suk
    • Communications for Statistical Applications and Methods
    • /
    • v.7 no.2
    • /
    • pp.447-456
    • /
    • 2000
  • In this paper, we considered three methods for outlier identification sample surveys. First, we studied method of handling and adjusting outliers in normal population. Second, we studied existing methods using mean, maximum and minimum and proposed a test using of median which well reflects characteristic of data regardless of sampling distribution. Finally, we showed our test using median works better than Dixon and mean test through simulation.

  • PDF

Fire Testing Methods For The Electric Hair Dryer (전기 헤어드라이기에 대한 화재 시험법에 관한 연구)

  • Jang, In-Hyeok;Na, Hyun-Jun;Moon, Eun-A;Lee, Chang-Hoon;Lim, Houng-Woo
    • Journal of Applied Reliability
    • /
    • v.16 no.1
    • /
    • pp.7-14
    • /
    • 2016
  • Purpose: The purpose of this study is to development the fire evaluating test methods for the Electric hair dryers. Methods: We was designed FMEA (Failure mode and effects analysis) in order to analyze the fire mechanism on the electric hair dryers and designed evaluating test methods (Durability tests on the environment, Mechanical durability tests) obtained through the two-step QFD (Quality Function Depolyment) and tested. Conclusion: We verified the evaluating fire test methods on the electric hair dryers through the analysis of the test results and some reproduction test.

Status and Prospect of Test Methods of Quality Silicone Water Repellent for Protecting Reinforced Concrete

  • Sun, H.Y.;Yuan, Z.Y.;Yang, Z.;Shan, G.L.;Shen, M.X.
    • Corrosion Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.141-150
    • /
    • 2017
  • Impregnating with quality silicone water repellent on the concrete surface is an effective method of protecting concrete. Quality silicone water repellent has been widely used in the engineering profession because of its desirable properties such as hydrophobicity, keeping concrete breathable and preserving the original appearance of the concrete. The companies in China that produce silicone water repellent are listed. Test methods in the specifications or standards about silicone water repellent in China are summed. The test methods relative to durability of concrete impregnated with silicone water repellent (such as resistant to chloride ion penetration, resistant to alkali, resistance to freezing and thawing and weatherability etc.) and the constructive quality (such as water absorption rate, impregnating depth and the dry velocity coefficient etc.) are compared and analyzed. The results indicate that there are differences among test methods relative to different specifications with the same index and therefore, confusion has ensued when selecting test methods. All test methods with the exception of the method of water absorption rate by using a Karsten flask are not non-destructive methods or conducted in a laboratory. Finally, further research on silicone water repellent during application is proposed.

Estimation of Predictive Value of a Positive Test from a Screening Test

  • Shin, Hyun Chul;Park, Sang Gue;Kim, Yong Hee
    • Communications for Statistical Applications and Methods
    • /
    • v.10 no.2
    • /
    • pp.567-574
    • /
    • 2003
  • The estimation problem of predictive value of a positive test(PVP), which is assessing the accuracy of a screening test is considered. Score methods discussed by Gart and Nam(1988) are proposed for constructing confidence interval for PVP. The simulation studies are conducted in evaluating the proposed methods and existing approximate ones.

Study of Performance Test Methods for RFID Devices Using Ontology Concept (온톨로지 기법을 이용한 RFID 장비성능 측정체계 및 방법)

  • Kwon, Hyun-Soo;Chang, Yoon-Seok
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.8 no.3
    • /
    • pp.144-151
    • /
    • 2009
  • In this paper, we consider various international and local standards and applied ontology concepts which are used in Semantic Web, to make more structured test methods/procedure. Based on the ontology concept, we classify test method as three categories (i.e., conformance test, interoperability test and performance test), and make test structures for each category. We believe that this research provides test methods which reflect various standards as well as the guidelines for users to construct RFID device software more structurally.

  • PDF

Index Properties and Undrained Shear Strength of the Pusan Clays by Fall Cone Test (부산점토의 Fall Cone Test에 의한 지수 및 강도특성)

  • ;;Pham Huy Giao
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.391-398
    • /
    • 2000
  • The index properties of cohesive soils play an important role to examine entire tendency of soil properties. Especially, the Atterberg limits have a good correlation with compression and shear strength of cohesive soils. However, these values strongly depend on their testing methods. In this study, for Pusan clays the Atterberg limits were peformed under different conditions; for example, four kinds of specimen preparation, two kinds of testing equipment, and four kinds of estimating method. And a laboratory vane test was peformed to compare the undrained shear strength with that of the fall cone test. As experimental results, the value of liquid limit performed for oven-dried sample, followed in ASTM D4318, underestimated by about 10% compared to those of another three methods, irrespective to the used equipments. But the value of plastic limit was not influenced by sample preparation methods and equipments. The liquid limits by one-point methods(Leroueil et al., 1996; Nagaraj et al., 1981) were agreed well with those of different methods. Finally, the undrained shear strength by laboratory vane test was relatively larger than that of fall cone test, and the relationship between both showed a bad trend.

  • PDF

Comparisons of Different Step-drawdown Test Analysis Methods; Implication for Improrvced Analysis for Step-drawdown Test Data (단계양수시험 해석 방법에 따른 우물 및 수리 상수 변동 분석)

  • An, Hyowon;Ha, Kyoochul;Lee, Eunhee;Do, Byung Hee
    • Journal of Soil and Groundwater Environment
    • /
    • v.25 no.4
    • /
    • pp.35-47
    • /
    • 2020
  • Step-drawdown test is one of the widely-used aquifer test methods to evaluate aquifer and well losses. Various approaches have been suggested to estimate well losses using the step-drawdown test data but the uncertainties associated with data interpretation and analysis still exist. In this study, we applied three different step-drawdown test analysis methods -Jacob (1947), Labadie and Helweg (1975), Gupta (1989)- to the step-drawdown test data in Seobu-myeon, Hongseong-gun, South Korea and estimated aquifer and well losses. Comparisons of different step-drawdown test analysis methods revealed that the estimated well losses showed different values depending on the applied methods and these variations are likely to be related to the limitation of the assumptions for each analysis method. Based on the detailed analysis of time-drawdown data, we performed step-drawdown test analysis after removing outlier data during the initial stage of step drawdown test. The results showed that the application of the revised time-drawdown data could substantially decrease the error of the analysis as well as the variations in the estimated well losses from different analysis methods.

Diagnostic Evaluation Methods in TMJ Balancing Medicine (턱관절균형의학의 기본 진단검사법)

  • Lee, Young-Jun;Yin, Chang Shik
    • Journal of TMJ Balancing Medicine
    • /
    • v.3 no.1
    • /
    • pp.27-30
    • /
    • 2013
  • Diagnostic evaluation methods frequently adopted in Temporomandibular Balancing Medicine (TBM) are briefly reviewed as to their basic concepts and procedures. TBM diagnostic evaluation methods may be classified into direct and indirect ones. Indirect methods are to observe any change in the manifestations with regard to the (1) posture, (2) pain, (3) muscle strength, and (4) stretching. Direct methods are to evaluate through (1) cervical palpation test, (2) restricted cervical rotation test, and (3) lateral cervical tension test. These methods may provide clinicians valuable information on the current yinyang balance and potential therapeutic factors in relation with the temporomandibular joint, a meridian system, and the whole body.

  • PDF