• Title/Summary/Keyword: Test method of performance

검색결과 5,858건 처리시간 0.138초

도포형 표면강화제 적용 콘크리트의 성능 검증법에 관한 연구 (A Study on Verification Method for the Performance of Surface-Treatment Agent Applied on Concrete)

  • 고경택;김성욱
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회 논문집(II)
    • /
    • pp.1025-1030
    • /
    • 2000
  • Recently, surface-treatment agent was developed to restore performance of the deteriorated concrete and inhibiting corrosion of the reinforcing-bar. The performance of surface-treatment agent was verified and this agent has been broadly in America and European countries. However, this type agent has not been used broadly in Korea because performance of the agent isn't verify by a proper test method yet. In this study, we suggested our own test procedures and methods through extensive laboratory tests to verify the performance of concrete after applying the surface-treatment agent.

직류 전기철도 성능시험을 위한 레일전위시험 적용연구 (A study on Rail Potential Test adaptation for Performance test of DC Railway system)

  • 정호성;장동욱;한문섭;박현준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.238-240
    • /
    • 2007
  • This paper present adaptation method of rail potential test to verify DC railway system's performance and safety. For protection of person and utility caused by rail potential rise, international standard to limit rail potential rise is made and rail potential is tested at the time of plan and construction of DC railway system in foreign country. So, we need rail potential test at the opening time and prepare a continuous monitoring technique of rail potential and a limitation method of rail potential rise. For these, we describe cause of rail potential rise, international standard about rail potential, protection principle, an example of calculation and measurement, and adaptation method for performance test.

  • PDF

구조보강용 FRP 함침.접착수지의 압축.휨 특성치 시험방법 비교 연구 (Comparative Study on Test Method of Compressive and Flexural Characteristics of Structural Adhesives for FRP Composites used in Strengthening RC Members)

  • 유영찬;최기선;김긍환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.349-352
    • /
    • 2006
  • Pull-off test is generally used as a method of evaluating bond strength of FRP with concrete at the job site. However, pull-off test damages FRP composites and the maximum pull-off strength is limited up to tensile strength of concrete. Accordingly, it is required to set-up a test method that can simply evaluate bond performance of structural adhesive. This study suggested compression and bending test of epoxy resin as test methods that can indirectly evaluate performance of adhesive, as well as standardized test specification for different types of specifications from various countries. In this study, the section dimension of compression and bending test specimens is unified, and standard test specimen size is achieved by test results.

  • PDF

하이브리드 조립형 보강 기법을 적용한 철근콘크리트 보의 휨 성능 평가에 관한 실험적 연구 (An Experimental Study on Flexural Performance of RC Beams Reinforced With Hybrid Prefabricated Retrofit Method)

  • 문상필;이성호;이영학;김민숙
    • 한국공간구조학회논문집
    • /
    • 제20권4호
    • /
    • pp.131-139
    • /
    • 2020
  • In this paper, the hybrid prefabricated retrofit method is suggested and examined. Six specimens were manufactured in order to evaluate their flexural performance of RC beams. Test parameters include the added beam depth, the thickness of bottom plate, the number of the steel plate with openings. The effects of these parameters on the flexural performance of reinforced concrete beams were examined. The load-deflection behavior and modes of cracks are presented from the test results. At the test result, the flexural capacity and the ductility of the hybrid prefabricated retrofit method was increased satbly. Also, comparing the flexural performance of RC beam and retrofitted RC beams, it was increased that the flexural strength is about 3.3 times, the ductility is about 2.55 times, and energy dissipation capacity is about 7.34 times.

발전설비의 성능진단 적용 무선계측 기술 (Wireless Measurement Technology for Power Plant Performance Diagnosis)

  • 김의환;이응곤;홍은기
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제3권1호
    • /
    • pp.9-16
    • /
    • 2017
  • The performance test is conducted for the purpose of determining the accurate thermal performance of the power generation facility or deriving the factors of thermal efficiency degradation. Compared to the acquisition method of power plant thermal performance test data by compensating cable or transmission cable, performance test using wireless instrument can acquire digital data in order to shorten the period due to installation and demolition of instrument and enhance safety of workers and relatively accurate data can be acquired thereby improving work efficiency. Wireless instruments have already been introduced to the market a long time ago, and some of them are used in industry such as petrochemical industry. However, there is no example which has been conducted for performance test of power generation facilities. In order to apply power generation facilities, a reliable system capable of acquiring performance data smoothly without affecting the control system is required. The wireless measurement system can eliminate the measurement defects and errors such as the damage due to the movement of the connecting cable, the extension due to the extension of the shield wire, the contact failure at the contact point between the measuring sensor and the connecting wire, This method has the advantage of collecting relatively accurate performance test data.

근전의수의 성능시험방법에 대한 연구 (Study on a test method for the performance of myoelectric hand prosthesis)

  • 최기원;최규하;신우석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.265-266
    • /
    • 2010
  • This paper propose the test method for performance of myoelectric hand prosthesis(MHP) according to myoelectric signal generated in the human muscle. The MHP consists of a mechanical hand, a surface myoelectric sensor(SMES) for measuring myoelectric signal, a control system and a charging battery. The propose test method is proved the reliability of MHP.

  • PDF

회귀 테스팅의 테스트 케이스 우선 순위화 기법의 실험적 연구 (Empirical Study on Test Case Prioritization Techniques of Regression Testing)

  • 소선섭;채의근
    • 정보처리학회논문지D
    • /
    • 제12D권2호
    • /
    • pp.283-288
    • /
    • 2005
  • 테스트 케이스 우선 순위화는 회귀 테스팅이 시간 제약 하에서 주어진 모든 테스트 케이tm를 수행할 수 없을 때 테스트 케이스의 실행 순서를 스캐쥴링하는 것이다. 본 논문에서는 장기적인 회귀 테스팅 환경에서 과거의 테스트 실행 및 오류 검출 정보를 활용한 HED우선 순위화 방법을 제안하고, 이를 기존의 Random 및 LRU 방법과 비교하였다. 본 실험을 통해 몇 가지 중요한 통찰을 얻을 수 있었다. 첫째, 우선 순위화 방법들이 프로그램의 특성에 따라 성능 면에서 상호 보완적이라는 점이다. 오류를 찾는 테스트 케이스들을 많이 갖고 있는 프로그램의 경우에는 Random이 효과적이고, 상대적으로 오류를 찾는 테스트 케이스의 비율이 작은 경우에는 제안된 HED방법이 좋은 성능을 보였으며, 중간 정도인 경우에는 LRU 방법이 효과적이었다. 둘째, 전체적인 성능이 테스트 스위트의 크기에 영향을 많이 받는다는 점이다. 테스트 스위트의 크기를 달리하여 실험한 결과 오류의 수명 값과 그 성능 순위에 차이를 보였다. 마지막으로 전체 테스트 케이스의 $20\%$만을 실행하여도 전체 테스트 케이스 모두를 실행하는 것과 성능 면에서 유사한 결과를 얻을 수 있다는 점 등이다.

통신방송위성 탑재체 정합시험 방법에 관한연구 (Interface Test Method for Communications and Broadcasting Satellite Payload)

  • 김신홍;김인준;최완식;이성팔
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(1)
    • /
    • pp.291-294
    • /
    • 2002
  • This paper proposed interface test method for performance verification of communication and broadcasting satellite between communication and broadcasting satellite payload and EGSE(Electrical Ground Support Equipment). We need ground support equipment for test them to performance verification and conform interface function of payload. This paper define tile telemetry transfer method for control payload using GSE(Ground Support Equipment) and receive telemetry data collected from GSE through bus simulator

  • PDF

실내모형시험을 통한 지반혼합 및 주입공법의 노후저수지 차수 보강성능 비교 연구 (A Comparative Study on the Impermeability-reinforcement Performance of Old Reservoir from Injection and Deep Mixing Method through Laboratory Model Test)

  • 송상훤
    • 한국농촌건축학회논문집
    • /
    • 제24권2호
    • /
    • pp.45-52
    • /
    • 2022
  • Of the 17,106 domestic reservoirs(as of December 2020), 14,611 are older than 50 years, and these old reservoirs will gradually increase over time. The injection grouting method is most applied to the reinforcement method of the aging reservoir. However, the injection grouting method is not accurate in uniformity and reinforced area. An laboratory model test was conducted to evaluate the applicability of the deep mixing method, which compensated for these shortcomings, as a reservoir reinforcement method. As a result of calculating the hydraulic conductiveity for each method through the model test results, the injection grouting method was calculated as a hydraulic conductiveity value that was about 7.5 times larger than that of the deep mixing method. As a result of measuring the water level change in the laboratory model test, it was found that the water level change decreased in the injection method and deep mixing method compared to the non-reinforcement method. In addition, deep mixing method showed a water level change of about 15% based on 40 hours compared to the injection method, indicating that the water-reducing effect was superior to that of the injection method.

일반 및 군용 차량용 인버터 가속수명시험법 제안 (Proposal of Accelerated Life Test Method of Inverter for General and Military Vehicles)

  • 장인혁;김정호;형재필;임홍우;최연옥
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제17권2호
    • /
    • pp.136-142
    • /
    • 2017
  • Purpose: In this paper, we propose a test method for evaluating the life time of the inverter which is one of the main internal configuration systems in order to evaluate the life time of the power supply for the vehicle. Methods: The performance and failure criteria required for the development of the accelerated life test method were established and the Taguchi method was used to derive the stress factors affecting performance and reliability. Results: The major stress of the product degradation were considered to be high temperature. Conclusion: The acceleration factor was estimated through a two-level high temperature test and a test methods was designed to guarantee the accelerated life time of the inverter.