• Title/Summary/Keyword: Test field

Search Result 9,504, Processing Time 0.034 seconds

Assessment on Natural Frequencies of Structures using Field Measurement and FE Analysis

  • Kim, Do Hyun;Kim, Ji Young
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.4
    • /
    • pp.305-310
    • /
    • 2014
  • Wind-induced responses of a structure are often evaluated through dynamic analysis, where measured wind forces obtained from a wind-tunnel test and dynamic properties obtained from a FE (Finite Element) model are utilized. However, the FE model generally shows considerable discrepancies in the estimation of natural frequencies compared to field measurements due to some assumptions and simplifications. In this paper, a calibration method that can improve the estimation of natural frequencies in the FE model is proposed, and specific cases are studied for its validity with comparison to the field measurement results.

Geocomat를 활용한 폐기물매립장의 사면안정성 검토

  • 신은철;이성근;이영재
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.06a
    • /
    • pp.45-54
    • /
    • 2001
  • In this study, slope stability analysis of LCRS(Leachate Collection Removel System) in waste landfill was peformed by large scale field test. Geocomat is new type of geocomposite product. Gecomat is a sort of Geocomposite product. It is composed of nonwoven geotextiles, woven geotextile, and geonet. Large scale field tests were performed on the slope of different two LCRSsections with static loading condition. One is LCRS section witch consist of GCL, HDPE and Geocomat, another is GCL, HDPE, and woven type geocomposite. The behavior of geosynthetics lined slope was monitored by incorporating instrumentation including vertical soil pressure meter, settlement plate, strain gauges, potential meter, displacement pin.. Based on the field monitoring, the Geocomat LCRS section is less sliding than the conventional geocomposite LCRS section.

  • PDF

Field Testing Center Design of Cathodic Protection System for Maritime Metallic Structures (해양구조물 전기방식시스템 현장적용실험장 설계)

  • Ha, Tae-Hyeon;Bae, Jeong-Hyo;Lee, Hyeon-Gu;Ha, Yun-Cheol;Kim, Dae-Gyeong
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.633-636
    • /
    • 2003
  • Most of maritime metallic structures are adopted a CP(Cathodic Protection) System for protection of corrosion in advanced country. So, we had been developed a remote corrosion monitoring control system. And we want to know the characteristics of efficiency, reliability, durability and so on. On the view point of it, we have to test in real field. in terms of design, cathodic protection systems, corrosion monitoring systems and optimal corrosion control systems compare to general commercial products. So, these systems have being studied to improve their capability. In this paper, the result of field testing center design of intelligent cathodic protection system including anodes, a real-time wireless remote corrosion monitoring and corrosion control system are described in naval ports.

  • PDF

A Study on Self-Concept and Satisfaction on Field Practice of E.M.T. College Students (일부 응급구조 전문대학생의 자아개념과 현장실습 만족도에 관한 연구)

  • Choi, Eun-Sook;Lee, In-Soo
    • The Korean Journal of Emergency Medical Services
    • /
    • v.1 no.1
    • /
    • pp.87-99
    • /
    • 1997
  • The purpose of this study was to analyze and confirm the correlation between self-concept and the degree of satisfaction on field practice of EMT students. Data were collected from 66 junior college EMT students by quertionaire from August 12 to 13, 1997. The data were analyzed by percentage, mean, t-test, F-test, and Person correlation using SAS program. The results of this study were as follows : 1. Self-concept level revealed to be high as 3.784 of a total score 5.0. 2. Satisfaction level revealed to be low as 2.970 of a total score 5.0. Satisfaction level of teaching revealed to be high and environments revealed to be low. 3. Subject satisfaction, practice time were significant in satisfaction level on field practice. 4. Self-concept was not influenced to the degree of satisfaction on field practice.

  • PDF

Evaluation of Bridge Load Carrying Capacity of PSC Girder Bridge using Pseudo-Static Load Test (의사정적재하시험을 이용한 PSC 거더교의 공용 내하력평가)

  • Yoon, Sang-Gwi;Shin, Soobong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.4
    • /
    • pp.53-60
    • /
    • 2019
  • In this study, a method for updating the finite element model of bridges with genetic algorithm using static displacement were presented, and verified this method using field test data for PSC girder bridge. As a field test, static load test and pseudo-static load test were conducted, and updated the finite element model of test bridge using each test data. Finally, evaluated the bridge load carrying capacity with updated model using pseudo-static load test's displacement data. To evaluate the bridge load carrying capacity, KHBDC-LSD, KHBDC and AASHTO LRFD's live load model were used, and compared the each results.

Fog Generated Field Test for Criteria of Sign Size of Variable Speed Limit Signs (가변 제한속도 표지판 크기기준 정립을 위한 안개재현 현장실험)

  • Kim, Yongseok;Lee, Sukki;Kim, Soullam
    • International Journal of Highway Engineering
    • /
    • v.18 no.6
    • /
    • pp.87-96
    • /
    • 2016
  • OBJECTIVES : A fog generated field test was conducted to analyze the relationship between different sizes of variable speed limit signs and the legibility distance under various fog density conditions. By using this study, appropriate sizes of signs can be selected depending on the density of fog. METHODS : An actual tunnel was selected as the area for this test, as other places cannot maintain the fog condition because of rapid air current. A total 121 subjects were recruited for this test, which took place over the course of four days. The test on the first day was conducted under normal weather conditions for comparison. Visibility-distance detecting sensor was used to measure the visibility distance due to the fog density time, simultaneously with the evaluation of legibility distance by subjects. RESULTS : The test results show the relationship between the different sizes of signs and the legibility distance corresponding to the visibility distance due to both non-fog and fog generated conditions. According to the technical test results, appreciable amount of reduction in legibility distance due to fog was resulted in all sizes of signs. Moreover, the legibility distance is reduced proportionately with the decrease in the visibility distance due to fog. CONCLUSIONS : The results of this study can be used to select appropriate sizes of valuable speed signs under fog conditions. Hence, drivers can expect to have more room to respond to adverse weather conditions, thereby reducing the risk of accidents.

Fog Generated Field Test for Luminance Criteria of Variable Speed-Limit Signs (가변속도형 표지 휘도기준 정립을 위한 안개재현 현장실험)

  • Kim, Yongseok;Lee, Sukki;Kim, Soullam
    • International Journal of Highway Engineering
    • /
    • v.18 no.6
    • /
    • pp.77-85
    • /
    • 2016
  • OBJECTIVES : A fog generated field test was conducted to analyze the relationship between the luminance of variable speed-limit signs and the legibility distance under various fog density conditions. By using this study, appropriate luminance values can be selected depending on the density of fog. METHODS : An actual tunnel was selected as the area to conduct the test, as other places cannot maintain the fog condition because of rapid air current. Ninety-two subjects were recruited for this test, which took place during the course of three days. Visibility-distance detecting sensor was used to measure the visibility distance due to the fog density time, simultaneously with the evaluation of legibility distance by subjects. RESULTS : The test results show the relationship between luminance values and the legibility distance corresponding to the visibility distance due to fog. According to the technical test results, lower luminance value such as $7000cd/m^2$ corresponds to less legibility distance compared to higher values such as $20000cd/m^2$ or $40000cd/m^2$. However, the amount of difference between $20000cd/m^2$ and $40000cd/m^2$ is negligible in our test. CONCLUSIONS : The results of this study can be used to select appropriate luminance of valuable speed signs under fog conditions. Hence, drivers can expect to have more room to respond to adverse weather conditions, thereby reducing the risk of accidents.

Antenna Test Range for Telecommunication Satellite (통신위성용 안테나 테스트 레인지)

  • Lim, Seong-Bin;Kim, Tae-Youn;Choi, Seok-Won;Sim, Eun-Sup
    • Aerospace Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.52-59
    • /
    • 2007
  • Telecommunication satellite consists of a bus system and an RF payload system with high efficiency and high gain reflector antennas. Antenna measurement and also RF system performance (antenna under test, payload and satellite level) have to be evaluated enough before launching in the far-field range or equivalent test range. Basically far-field range is required in a range from two hundred meters to several kilo meters, and it is highly constrained to the externa1 environment, like the RF and the whether environment So the compact antenna test range is developed and used efficiently without external environments as in-door facility. This paper describes the configuration of the compact antenna test range, the range error, and the physical concept of the plane wave illumination Also, it provides a overall design of the anechoic chamber and range parameter values to accommodate the precision measurements in antenna test range.

  • PDF

Field Tests for the Application of Bottom Ash and Shred Tire as Fill Materials (석탄회 및 폐타이어의 성토재로의 적용성 검토를 위한 현장시험)

  • Lee, Sungjin;Lee, Taeyoon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.10
    • /
    • pp.29-37
    • /
    • 2013
  • In this study, we constructed the test embankment with four kinds of sections(2 kinds of bottom ash; tire shred-bottom ash mixture, weathered soil) in field and had been monitoring the behaviour of the test embankment and change of ground water quality for 1 year. In the geotechnical aspects, there was no relative difference of deformation in 4 test materials section and we could not see the possibility of the strength-reduction of coal ash materials by freezing inside of the embankment. In addition, no settlement was observed in the test sections because the base soil of the test sections was rigid enough that no consolidation was occurred. In the examination of water quality, all of the heavy metals and negative ions were detected below the drinking water standards except for sulfate($SO_4^{2-}$). In the beginning of measurement, higher concentrations of sulfate from 4 test sections were detected than drinking water standard for 20 days after beginning of the test but the concentrations decreased below the drinking water standard after 50 days after the tests.

Field Test on IEC60364-4-44 for the Application in Korean distribution system (IEC60364-4-44의 국내 배전계통 적용을 위한 실증시험)

  • Nam, Kee-Young;Choi, Sang-Bong;Jeong, Seong-Whan;Lee, Jae-Duck;Ryoo, Hee-Suk;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.486-487
    • /
    • 2006
  • The authors have studied on the application of IEC 60364-4-44 to Korean electrical installations of buildings from 2004 sponsored by Korean ministry of commerce, industry and energy and the test field is established in K.E.R.I. (Korea Electrotechnology Research Institute). This paper presents the summary results of establishment of test field and analysis for the application of IEC 60364 in Korea. IEC 60364-4-44 provides rules for the protection against the effects of conducted and radiated disturbances on electrical installations. Especially this standard deals with the protection of low voltage facility against the ground fault in the high voltage side of power distribution system. Many countries define the regulations on the use and production of electrical facilities based on their own power system and technical references which are considered to be suitable for them. The background of circuit of IEC 60364-4-44 is based on the ungrounded system as most of European countries. However, since Korean electric power distribution system is based on multi-grounding system different from European system, it is necessary to evaluate or prove the effect of the IEC 60364-4-44 for introducing and applying it to the domestic grounding system as a Korean standard. This paper presents the establishment of test field to get background data to introduce the IEC 60364-4-44 and to evaluate the standard is applicable to domestic rule for the protection against ground fault through the related test

  • PDF