• 제목/요약/키워드: Test and evaluation

검색결과 14,965건 처리시간 0.051초

Development of an evaluation method for nuclear fuel debris-filtering performance

  • Park, Joon-Kyoo;Lee, Seong-Ki;Kim, Jae-Hoon
    • Nuclear Engineering and Technology
    • /
    • 제50권5호
    • /
    • pp.738-744
    • /
    • 2018
  • Fuel failure due to debris is a major cause of failure in pressurized water reactors. Fuel vendors have developed various filtering devices to reduce debris-induced failure and have evaluated filtering performance with their own test facilities and methods. Because of the different test facilities and methods, it is difficult to compare filtering performances objectively. This study presents an improved filtering test and an efficiency calculation method to fairly compare fuel-filtering efficiency regardless of the vendor's filtering features. To enhance the reliability of our evaluation, we established requirements for the test method and had a facility constructed according to the requirements. This article describes the debris specimens, the amount of debris, and the replicates for the proposed test method. A calculation method of comprehensive debris-filtering efficiency using a weighted mean is proposed. The test method was verified by repeated tests, and the tests were carried out using the PLUS7 and 17ACE7 test fuels to calculate the comprehensive debris-filtering efficiencies. The evaluation results revealed that the filtering performance of PLUS7 is better than that of 17ACE7. The proposed method can be used on any kind of debris-filtering devices and is appropriate for use as a standard.

A Study on the Development of Traction Motor for Electric Railway: Insulation System Design & Performance Test

  • Wang, Jong-Bae
    • Transactions on Electrical and Electronic Materials
    • /
    • 제2권4호
    • /
    • pp.19-23
    • /
    • 2001
  • In this paper, design considerations and manufacturing procedure of 200 class insulation system with polyimide(Kapton) main insulation and silicone resin VPI process on the traction motor thor EMU will be reviewed. The performance test and the long life evaluation test that prove stability and reliability of Insulation system for traction motor will also be introduced.

  • PDF

장기간 사용된 발전설비용 고온 스터드 암나사부 관리방법 (Managing method for stud female threads used long period under high temperature on the power plants)

  • 정남용;김문영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집A
    • /
    • pp.199-205
    • /
    • 2000
  • The stud female threads for stud bolts tend to degrade faster by high temperature over 450 C. Therefore, inspection for replacement cycle of stud bolts is used to carry out many kinds of method such as ultrasonic test(UT), magnetic test(MT), wobble test, visual test and hardness test. The visual inspection among those has been only applied for stud female threads generally and wobble test is often used to apply stud bolts. In this paper, wobble test is applied for evaluation of stud female threads on the contrary stud bolts especially. It is also applied three types of inspection method included wobble test on the two sites which is used for each other different operation cycle and three kinds of acquisition data are compared with evaluation methods. From the results, we have studied the characteristic exchanging of integrity evaluation data distribution according to using time and proposed managing method for female thread of stud on the power plants.

  • PDF

주행 구동 유니트의 가속 수명 시험 및 분석 (Accelerated Life Test and Analysis of Track Drive Unit for an Excavator)

  • 이용범;박종호
    • 유공압시스템학회논문집
    • /
    • 제2권2호
    • /
    • pp.1-7
    • /
    • 2005
  • For the reliability evaluation of the track drive unit(TDU), firstly, we analyzed the major failure modes through FMEA(failure mode & effects analysis), FTA(failure tree analysis), and 2-stage QFD(quality function deployment), and then quantitatively determined the priority order of test items. The Minitab analysis was also performed for prediction of life distribution and parameters of TDU by use of field failure data collected from 430 excavators for two years. In addition, we converted the fluctuation load in field conditions into the equivalent load, and for evaluation of the accelerated lift by the cumulative fatigues, the equivalent load is again divided into the fluctuation load by reference of test time. And then, by use of the test method in this paper, the acceleration factor(AF) of needle bearing inside planetary gear which is the most weakly designed part of TDU is achieved as 5.3. This paper presents the quantitative selection method of test items for reliability evaluation, the determination method of the accelerated life test time, and the method of non-failure test time based on a few of samples. And, we proved the propriety of the proposed methods by experiments using a TDU for a 30 ton excavator.

  • PDF

반도체장비용 오링의 종합 신뢰성 평가기술에 관한 연구 (A Study on the Reliability Evaluation System for O-ring of Semiconductor Equipments)

  • 김동수;김광영;최병오;박화영
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.613-617
    • /
    • 2001
  • The test items like as endurance, air leakage and oil endurance test is requested for reliability evaluation about O-ring which is a kind of core machinery accessories of semi-conduct manufacturing equipment. For verification of these, we design and manufactured a test system for endurance, air leakage and oil endurance of O-ring for semi-conduct manufacturing equipment, and also performed the test for two kinds of O-ring, as it were Viton and Kalretz. The characteristics of this test equipment consist in realization of the test conditions of semi-conduct manufacturing equipment and satisfying the test method. The test conditions are cut gas, vacuum grade, temperature and revolution numbers in the endurance test system, vacuum grade and temperature in the air leakage test system, temperature and time in the oil endurance test system. The separating test results for wearing which is an oil endurance test item, the wearing index of domestic produced Viton O-ring is higher than foreign product by 2%, wearing rate of Kalretz O-ring better than Viton O-ring by 17%, and particles existed in various place. The test result of air leakage which is measured through the RGA sensor used Helium, the vacuum grade was $10^-3$Torr. And the test result of oil endurance, the volume change rate was 7~15%. Hereafter, we intend to analysis the reliability test evaluation and to utilize for domestic manufacturing companies by establishing data base and developing reliability softwares.

  • PDF

TLS용 테스트 타깃의 개발과 거리측정 정확도 검증 (The Evaluation of Distance Accuracy and The Test Target Manufacturing of A Terrestrial Laser Scanner)

  • 이인수;차득기;서호성
    • 한국측량학회지
    • /
    • 제30권3호
    • /
    • pp.279-285
    • /
    • 2012
  • 지상3차원레이저스캐너는 산사태 모니터링, 문화재 문서화, 토목건설, 도시공학 등의 분야에 그 활용이 날로 증가하고 있다. 그러나 지상3차원레이저스캐너의 측정값의 정확도 평가, 실험용 타깃 및 장비 교정, 그리고 시험 절차 등에 대한 국제 표준규정이 마련되어 있지 않다. 이에 본 연구에서 지상3차원레이저스캐너의 거리측정을 위한 타깃을 제작하였고, 또 이 타깃으로 지상3차원레이저스캐너의 거리측정 정확도를 검정하여 실험용 타깃으로서의 적합성을 확인하였다.

Verifying ASCE 41 the evaluation model via field tests of masonry infilled RC frames with openings

  • Huang, Chun-Ting;Chiou, Tsung-Chih;Chung, Lap-Loi;Hwang, Shyh-Jiann;Jaung, Wen-Ching
    • Earthquakes and Structures
    • /
    • 제19권3호
    • /
    • pp.157-174
    • /
    • 2020
  • The in-situ pushover test differs from the shake-table test because it is performed outdoors and thus its size is not restricted by space, which allows us to test a full-size building. However, to build a new full-size building for the test is not economical, consequently scholars around the world usually make scale structures or full-scale component units to be tested in the laboratory. However, if in-situ pushover tests can be performed on full-size structures, then the seismic behaviors of buildings during earthquakes can be grasped. In view of this, this study conducts two in-situ pushover tests of reinforced concrete (RC) buildings. One is a masonry-infilled RC building with openings (the openings ratio of masonry infill wall is between 24% and 51%) and the other is an RC building without masonry infill. These two in-situ pushover tests adopt obsolescent RC buildings, which will be demolished, to conduct experiment and successfully obtain seismic capacity curves of the buildings. The test results are available for the development or verification of a seismic evaluation model. This paper uses ASCE 41-17 as the main evaluation model and is accompanied by a simplified pushover analysis, which can predict the seismic capacity curves of low-rise buildings in Taiwan. The predicted maximum base shear values for masonry-infilled RC buildings with openings and for RC buildings without masonry infill are, respectively, 69.69% and 87.33% of the test values. The predicted initial stiffness values are 41.04% and 100.49% of the test values, respectively. It can be seen that the ASCE 41-17 evaluation model is reasonable for the RC building without masonry infill walls. In contrast, the analysis result for the masonry infilled RC building with openings is more conservative than the test value because the ASCE 41-17 evaluation model is limited to masonry infill walls with an openings ratio not exceeding 40%. This study suggests using ASCE 41-17's unreinforced masonry wall evaluation model to simulate a masonry infill wall with an openings ratio greater than 40%. After correction, the predicted maximum base shear values of the masonry infilled RC building with openings is 82.60% of the test values and the predicted initial stiffness value is 67.13% of the test value. Therefore, the proposed method in this study can predict the seismic behavior of a masonry infilled RC frame with large openings.

기계편용 장식사 니트소재의 물성 및 감성 평가 (Physical and Hand Properties of the Knitted Fabrics From Machine Knitting Fancy Yarns)

  • 박기윤;박명자
    • 한국의상디자인학회지
    • /
    • 제10권2호
    • /
    • pp.125-138
    • /
    • 2008
  • For physical and hand property evaluation of fabrics, the knitted fabrics from 11 types of machines knitting fancy yarns, boucle (M1), knot (M2), snarl (M3), and slub (M4), tamtam (M5), tubular (M6), fur 1 (M7), bead (M8), fur 2 (M9), fur 3 (M10), and ladder (M11) yarns, were prepared with 7-10 G plain stitch. Washing test and pilling test had also been carried out. For hand properties by objective sensibility evaluation, 17 items of sir mechanical properties using KES-FB (Kawabata Evaluation System) had been measured. Then hand values of knitted fabrics were calculated with a calculation formula, namely KN-402-KT. Finally the total hand values were obtained through KN-301-WINTER. As a result of physical properties and objective evaluation for machines knitting fancy fabrics, most of them shrank in the direction of wale and course after the washing test, in which their shrinkage rate had a maximum of 3.5%. Therefore, the washing test indicated that the shrinkage ratio of knitted fabrics had a minor change. The results of the pilling test are mostly 4-5th grade, and all of the machines knitting fancy fabrics showed good results in the pilling resistance. In hand properties and objective sensibility evaluation, twisted fancy yarns, such as boucle (M1), knot (M2), snarl (M3), and slub (M4), were superior to bonding rigidity (B) and shear rigidity (G). The surface property between course and wale differs in all samples and course direction is tougher than wale direction. FUKURAMI (fullness and softness) of all samples have high values, besides NUMERI (smoothness) of tamtam (M5) and boucle (M1), which were rather good. Most samples except fur 1 (M7) had low KOSHI (stiffness) value. The total hand value (THV) of twisted yarns was low. This study proves that manufacturers, who plan knitting yarn products and knit fashion, can apply these data to develop machines knitting yarns and knits that fit the consumers' demands.

  • PDF

고정목표에 대한 자율주행자동차 시험방법에 관한 연구 (A Study on the Test Method of Autonomous Vehicle for Fixed Targets)

  • 김봉주;이선봉
    • 자동차안전학회지
    • /
    • 제14권3호
    • /
    • pp.6-16
    • /
    • 2022
  • Recent, the issue of the fourth industrial revolution triggered by technological advances has changed the automobile industry centered on internal combustion engines, and quantitative growth of the global automobile market, which has grown rapidly, has been slowing since 2015. These advances in technology are expected to develop beyond the advanced driver assistance system to autonomous driving technology. According to SAE-J3016 published by the Society of Automotive Engineers, the technology of autonomous vehicles is divided into a total of six stages according to the driver's intervention and automation level from 0 to 5. Securing safety for autonomous vehicles is important. But, research on safety evaluation theory and autonomous vehicle evaluation method based on real vehicle test is insufficient. In this study, the longitudinal distance theory equation and continuous test scenario were proposed for the test method of autonomous vehicles for fixed targets, and the real vehicle test was conducted. When comparing the theoretical values compared to the measured values, it was determined that it was reliable with a minimum error rate of 0.484% and a maximum error rate of 7.391%. Using the proposed theoretical equation, it is judged that it can be used as a safety evaluation method in an environment where real vehicle test is not possible because it can grasp the trend in the longitudinal direction in the development stage.

Test Plan for Anti-Jamming System Performance Evaluation

  • Park, Ji-Hee;Kwon, Seung Bok;Shin, Dong-Ho
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제4권1호
    • /
    • pp.17-23
    • /
    • 2015
  • With the increase in the risk of GPS jamming, the development and application of anti-jamming GPS techniques have been actively performed. As the objective performance verification of developed techniques is important, equipment development for verification and discussion on anti-jamming performance test method and procedure have also been conducted. However, most tests are related to the specification of equipment and therefore detailed procedure of the performance verification of an anti-jamming system needs to be developed. In this study, requirements for anti-jamming performance verification were described, and test configurations and performance evaluation items depending on three kinds of test methods (lab test, basic outdoor test, and chamber test) were suggested for anti-jamming performance verification.