• 제목/요약/키워드: Test Validation

검색결과 1,786건 처리시간 0.029초

컴퓨터 시뮬레이션에 의한 미곡 도정공장의 적정설계 및 개발(II) -미곡 도정시스템의 개발 및 성능평가- (Optimal Design and Development of a Rice Mill Pilot Plant by Computer Simulation (II) -Development and Performance Evaluation of a Rice Mill Pilot Plant-)

  • 정종훈;김보곤;최영수
    • Journal of Biosystems Engineering
    • /
    • 제20권3호
    • /
    • pp.262-274
    • /
    • 1995
  • A rice mill pilot plant was designed and developed in the basis of the simulation results on the mill plants. The performance of the developed rice mill plant was evaluated, and the simulation model on the mill system was validated with the experimental data in the mill plant. The results of this study were as followings : 1. A rice mill pilot plant with the capacity of 0.5 t/h was designed and developed. 2. The hulled ratio of the mill plant was 87.3%, and the milled rice recovery and the head rice recovery of the cleaned rice were 74% and 87% , respectively. The degree of milling of the cleaned rice was 10.6% with a high polish. The intensity of the cleaned rice appeared high compared with that of the milled rice in the analysis of whiteness test using an image processing system. 3. The bottleneck, processing time, and production amount of the developed mill system almost coincided with those of the simulation of the rice mill plant. The developed simulation model of the rice mill plant was proven to be applicable to the design of a rice mill plant through experiments.

  • PDF

A REPRESENTATIVITY TEST OF THE SURFACE SOLAR INSOLATION THROUGH SATELLITE OBSERVATION

  • Yeom, Jong-Min;Park, Youn-Young;Kim, Young-Seup;Han, Kyung-Soo
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume II
    • /
    • pp.655-659
    • /
    • 2006
  • Surface Solar Insolation is important for vegetation productivity, hydrology, crop growth, etc. In this study, Surface Solar Insolation is estimated using Multi-functional Transport Satellite (MTSAT-1R) in clear and cloudy conditions. For the Cloudy sky cases, the surface solar insolation is estimated by taking into account the cloud transmittance and multiple scattering between cloud and surface. This model integrated Kawamura's model and SMAC code computes surface solar insolation with a 5km ${\times}$ 5km spatial resolution in hourly basis. The daily value is derived from the available hourly Surface Solar Insolation, independently for every pixel. To validation, this study uses ground truth data recorded from the pyranometer installed by the Korea Meteorological Agency (KMA). The validation of estimated value is performed through a match-up with ground truth. Various match-up with ground truth. Various match-up window sizes are tested with 3${\times}$3, 5${\times}$5, 7${\times}$7, 9${\times}$9, 10${\times}$10, 11${\times}$11, 13${\times}$13 pixels to define the spatial representativity of pyranometer measurement, and to consider drifting clouds from adjacent pixels across the ground station during the averaging interval of 1 hour are taken into account.

  • PDF

Optimization of Ascorbic Acid Extraction from Rugosa Rose (Rosa rugosa Thunb.) Fruit Using Response Surface Methodology and Validation of the Analytical Method

  • UM, Min;KIM, Ji-Woo;LEE, Jae-Won
    • Journal of the Korean Wood Science and Technology
    • /
    • 제48권3호
    • /
    • pp.364-375
    • /
    • 2020
  • In this study, ultrasound-assisted extraction was performed to extract ascorbic acid from rugosa rose (Rosa rugosa Thunb.) fruit. The optimal conditions were investigated by response surface methodology, using two variable including reaction time (16-44 min) and temperature (16-44℃). The ascorbic acid extraction was sensitive to the reaction time rather than the reaction temperature, and the optimal conditions for ascorbic acid extraction were 25℃ and 30 min. Ascorbic acid and gallic acid in the rugosa rose fruit extract were completely separated by HPLC, with a resolution factor of over 1.5 between the two. The correlation coefficient of the ascorbic acid was 0.999 in a linearity test for 50-150 ㎍/mL concentration of extract. The limit of detection and limit of quantification values were 0.16 ㎍/mL and 29.89 ㎍/mL, respectively. The relative standard deviations (RSD) for repeatability and reproducibility were determined, and each RSD showed good precision at less than 5% (N=6).

신경망모형을 이용한 외래환자 만족도예측 및 민감도분석 (A Neural Network for Prediction and Sensitivity of Outpatients' Satisfaction)

  • 이견직;정영철;김미라
    • 한국병원경영학회지
    • /
    • 제8권1호
    • /
    • pp.81-94
    • /
    • 2003
  • This paper aims at developing a prediction model and analyzing a sensitivity for the outpatient's overall satisfaction on utilizing hospital services by using data mining techniques within the context of customer satisfaction. From a total of 900 outpatient cases, 80 percent were randomly selected as the training group and the other 20 percent as the validation group. Cases in the training group were used in the development of the CHAID and Neural Networks. The validation group was used to test the performance of these models. The major findings may be summarized as follows: the CHAID provided six useful predictors - satisfaction with treatment level, satisfaction with healthcare facilities and equipments, satisfaction with registration service, awareness of hospital reputation, satisfaction with staffs courtesy and responsiveness, and satisfaction with nurses kindness. The prediction accuracy rates based on MLP (77.90%) is superior to RBF (76.80%).

  • PDF

Different Real Time PCR Approaches for the Fine Quantification of SNP's Alleles in DNA Pools: Assays Development, Characterization and Pre-validation

  • Mattarucchi, Elia;Marsoni, Milena;Binelli, Giorgio;Passi, Alberto;Lo Curto, Francesco;Pasquali, Francesco;Porta, Giovanni
    • BMB Reports
    • /
    • 제38권5호
    • /
    • pp.555-562
    • /
    • 2005
  • Single nucleotide polymorphisms (SNPs) are becoming the most common type of markers used in genetic analysis. In the present report a SNP has been chosen to test the applicability of Real Time PCR to discriminate and quantify SNPs alleles on DNA pools. Amplification Refractory Mutation System (ARMS) and Mismatch Amplification Mutation Assay (MAMA) has been applied. Each assay has been pre-validated testing specificity and performances (linearity, PCR efficiency, interference limit, limit of detection, limit of quantification, precision and accuracy). Both the approaches achieve a precise and accurate estimation of the allele frequencies on pooled DNA samples in the range from 5% to 95% and don't require standard curves or calibrators. The lowest measurement that could be significantly distinguished from the background noise has been determined around the 1% for both the approaches, allowing to extend the range of quantifications from 1% to 99%. Furthermore applicability of Real Time PCR assays for general diagnostic purposes is discussed.

수두차를 이용한 수저퇴적물 제거장치 개발에 관한 연구 (Study on the Development of Removing System for Waterbed Sediment by the Difference of Water Head)

  • 이영길;손충렬;정우철;유진원;정광열;김강신;김방열
    • 대한조선학회논문집
    • /
    • 제45권1호
    • /
    • pp.101-107
    • /
    • 2008
  • According to the existing research result on the seabed organic sediment, pollutants from the land and the sea contaminate the coastal water and sediment on the seabed. To tackle this problem, we need to dredge organic sediment. In the present paper, the development of removing system of seabed sediment by the difference of water head is researched by experimental method. For the validation of the decompression system, computations for validation are carried out for sediment removing equipment. The performance of inhalation equipment is analysed by some model tests.

An HPLC method for the determination of thioctic acid in raw material and tablets

  • Mai, Xuan-Lan;Ahn, GyeChan;Lee, SeokHan;Kang, Jong-Seong;Woo, Mi Hee;Na, Dong-Hee;Chun, In-Koo;Kim, Kyeong Ho
    • 분석과학
    • /
    • 제30권5호
    • /
    • pp.221-225
    • /
    • 2017
  • Thioctic acid is a vitamin-like antioxidant which is prepared as tablets and injection. The Korean Pharmacopoeia (KP XI) contains monograph for the quality control of raw thioctic acid using ultra-violet visible spectrophotometry and its formulations using high performance liquid chromatography (HPLC). In British Pharmacopoeia 2013 (BP2013), another HPLC method is used for the assay test of thioctic acid material. For the international harmonization, we present an HPLC method for quantitation of thioctic acid in both raw material and tablets. Method validation was performed to determine linearity, precision, accuracy, system suitability, and robustness. The linearity of calibration curves in the desired concentration range was high ($r^2=0.9995$), while the RSDs for intra- and inter-day precision were 0.93 ~ 1.26 % and 1.40 ~ 1.76 %, respectively. Accuracies ranged from 98.13-100.00 %. Since the system suitability, intermediate-precision and robustness of the assay were satisfactory, this method will be a valuable addition to the Korean Pharmacopoeia (KP XI).

임상간호인성 측정도구 개발 (Development and Validation of Nurse's Character Scale for Care in Clinical Settings)

  • 박정혜
    • 한국간호교육학회지
    • /
    • 제22권2호
    • /
    • pp.137-151
    • /
    • 2016
  • Purpose: The purpose of this study was to develop and validate a Nurse's Character Scale for Care in Clinical settings (NCS_C). Methods: The NCS_C was developed and validated as follows: Item generation, preliminary test of questionnaire, and tests of validity and reliability. One hundred and thirty six preliminary items were developed through a literature review and in-depth interviews by 10 nurse-experts and five patients. The content validity of the items was verified through an evaluation by five nurses and seven professors in the fields of Korean literature, pedagogy and nursing. Finally, 53 items were confirmed through item analysis, factor analysis and validity tests including convergent, discriminant and concurrent validities. Data were analyzed using factor analysis, Pearson correlation coefficients, and Cronbach's alpha. Results: Thirteen factors evolved from the factor analysis, which explained 63.1% of the total variance. The factors referred to the union of two dimensions: the professional dimension and the interpersonal dimension. The internal consistency, Cronbach's alpha, was .95, and reliability of the subscales ranged from .58 to .87. Conclusion: The results of this study suggest that the NCS_C is a reliable and valid primary scale to measure nurses' or students' character level for better care in clinical settings.

유아교육 프로그램 평가척도 개발에 관한 예비 연구 (A Preliminary Study for the Development of An Assessment Scale for Early Childhood Programs in Korea)

  • 이은해;이기숙
    • 아동학회지
    • /
    • 제15권1호
    • /
    • pp.5-21
    • /
    • 1994
  • The purpose of this study was to develop a scale for evaluation of early childhood programs in Korea. The procedures included content validation and a pilot test. A total of 192 items in 10 major areas was developed based on the review of literature and discussions with professionals in early childhood education. The 10 areas include: scheduling, curriculum, interation, physical environment, materials, nutrition, health and safety, administration, staff qualifications, relationships with parents, and evaluation. The pilot scale was administered to 428 classroom teachers and directors, and 47 college professors in early childhood education. The items were rated on a 3-point scale in terms of importance as evaluation criteria. The methods for data analysis included item means and standard deviations for content validation, Cronbach ${\alpha}$ for reliability, and factor analysis for construct validity. Most items in 10 areas were rated as moderate to highly important (average 2.3), especially items in curriculum and staff qualifications. Two factors emerged from the data: institutional management, and curricular planning and implementation. The Cronbach ${\alpha}$ levels were .70 or higher in most areas, but the range covers from .48 to .91. Based on the pilot data, 143 items were selected for the second year study.

  • PDF

Development of an Isotope-Dilution Flow-Injection Electrospray/ Mass Spectrometric Method for the Accurate Determination of Glucosamine in Pharmaceutical Formulation

  • Kim, Gui-Nam;Kim, Byung-Joo;Ahn, Seong-Hee;Hwang, Eui-Jin;Kim, Yong-Seong
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권2호
    • /
    • pp.363-367
    • /
    • 2009
  • An isotope-dilution flow-injection electrospray/mass spectrometric method was developed for the accurate determination of glucosamine contents in pharmaceutical formulations. Samples were extracted by methanol. After spiking glucosamine-1-$^{13}C_1$ as an internal standard, the extracts were then analyzed by flow-injection ESI/MS in a selected ion monitoring (SIM) mode to detect [M+H]$^+$ ions of the analyte and its isotope analogue at m/z 180 and m/z 181, respectively. Confirmatory measurements were made by selectively monitoring the collisionally induced dissociation channels of m/z 180 $\rightarrow$ m/z 72 and m/z 181 $\rightarrow$73, respectively, to test the possibility of bias in the SIM method due to matrix interferences, but any significant bias in the SIM mode was not observed. Repeatability and reproducibility studies showed that the flow-injection ESI/MS method is a reliable and reproducible method which can provide a typical method precision of 1.0 %. Other results for the method validation are reported.