• Title/Summary/Keyword: Test Unit

Search Result 3,993, Processing Time 0.029 seconds

COMPARISON OF LINEAR POLYMERIZATION SHRINKAGE IN COMPOSITES AND COMPOMER POLYMERIZED BY PLASMA ARC OR CONVENTIONAL VISIBLE LIGHT CURING (리노미터를 이용한 할로겐 가시광선 광조사기와 플라즈마 아크 광조사기의 복합레진 및 컴포머의 광중합 양상 비교)

  • Lee, Jae-Ik;Park, Sung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.5
    • /
    • pp.488-492
    • /
    • 2002
  • The purpose of this study was to evaluate the effectiveness of plasma arc curing (PAC) unit for composite and compomer curing. To compare its effectiveness with conventional quartz tungsten halogen (QTH) light curing unit, the polymerization shrinkage rates and amounts of three composites (Z100, Z250, Synergy Duo Shade) and one compomer, that had been light cured by PAC unit or QTH unit, was compared using a custome made linometer. The measurement of polymerization shrinkage was peformed after polymerization with either QTH unit or PAC unit. In case of curing with the PAC unit, the composite was light cured with Apollo 95E for 6s, the power density of which was recorded as 1350 mW/$\textrm{cm}^2$ by Coltolux Light Meter. For light curing with QTH unit, the composite was light cured for 30s with the XL2500, the power density of which was recorded as 800 mW/$\textrm{cm}^2$ by Coltolux Light Meter. The amount of linear polymerization shrinkage was recorded in the computer every 0.5s for 60s. Ten measurements were made for each material. The amount of linear polymerization shrinkage for each material in 10s and 60s which were cured with PAC or QTH unit were compared with t test. The amount of polymerization shrinkage in the tested materials were compared with 1way ANOVA with Duncan's multiple range test. As for the amounts of polymerization shrinkage in 60s, there was no difference between PAC unit and QTH unit in Z250 and Synergy Duo Shade. In Z100 and Dyract AP, it was lower when it was cured with PAC unit than when it was cured with QTH unit (p<0.05). As for the amounts of polymerization shrinkage in 10s, there was no difference between PAC unit and QTH unit in Z100 and Dyract AP. The amounts of polymerization shrinkage was significantly higher when it was cured with PAC unit in Z250 and Synergy Duo Shade (p<0.05). The amounts of polymerization shrinkage in the tested materials when they were cured with QTH unit were Z250 (6.6um) < Z100 (9.3um), Dyract AP (9.7um) < Synergy Duo Shade (11.2um) (p<0.05). The amount of polymerization shrinkage when the materials were cured with PAC unit were Dyract AP (5.6um) < Z100 (8.1um), Z250(7.0um) < Synergy Duo Shade (11.2um) (p<0.05).

A Study of the flight s/w test environment for the LEO satellite (저궤도위성 탑재소프트웨어 시험환경에 대한 연구)

  • Chae, Dong-Seok;Lee, Jae-Seung;Choi, Jong-Wook;Yang, Seung-Eun;Lee, Jong-In
    • Aerospace Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.45-51
    • /
    • 2007
  • The various levels of test are performed to verify the correctness, completeness, and quality of the developed flight software. The three main test levels are unit test, integration test and verification test. The flight software unit test is performed on the individual PC environment using target simulator. And integration and verification test is mainly performed on STB(S/W Test Bed) which provides test and debugging environments for flight software on the target board This document is to present the test environment for the next generation low earth orbit satellite flight software development.

  • PDF

A Steady-State Simulation and Experimental Study of Turboshaft Engine with Free Power Turbine (분리축방식 터보축 엔진의 정상상태 모사 및 실험연구)

  • 공창덕;기자영;고광웅
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.1 no.2
    • /
    • pp.84-90
    • /
    • 1997
  • The turboshaft engine with the free power turbine has been used for various purposes, for instance electric power generator, emergency power source, helicopter powerplant and so on. Steady-state simulation program was developed and experimental tests was carried out for comparing with computer simulation results. The test unit was composed of 1-stage centrifugal compressor, the can type combustor chamber, 1-stage radial type compressor turbine, and radial type free power turbine, and its output power is obtained from 3-phase AC generator. Main component characteristics which was used for the steady state simulation program, were obtained from the manufacturer of the test unit, and modified from experimental results of test unit. In comparison between computer simulation and experimental test results even though the test unit has the operational limit, deviation of component performance characteristics in simulation were within 6% range of experimental results.

  • PDF

Functional Testing of Level Crossing Obstruction Detecting System Using Laser Radar Sensor (레이저 레이더 센서를 이용한 건널목 지장물 검지장치의 기능시험)

  • Shin, Dong-Ho;Baek, Jong-Hyen;Choi, Hyeon-Yeong;Kim, Yong-Gyu
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39C no.3
    • /
    • pp.307-315
    • /
    • 2014
  • Existing level crossing obstruction detecting system occurs section of not detecting an obstruction by line detecting. Due to installation of decentralized equipment, it has become a problem in terms of safety and maintenance costs. accordingly, We have developed level crossing obstruction detecting system using laser radar sensor in order to solve these problems. In this paper, Describe results of functional test for the developed level crossing obstruction detecting system. functional tests are normal operation test(control unit and sensor unit) and test to display the fault information in event of a failure(control unit and sensor unit). It was confirmed that it works properly all according to functional test of level crossing obstruction detecting system using laser radar sensor.

Adaptive Random Testing for Integrated System based on Output Distribution Estimation (통합 시스템을 위한 출력 분포 기반 적응적 랜덤 테스팅)

  • Shin, Seung-Hun;Park, Seung-Kyu;Choi, Kyung-Hee;Jung, Ki-Hyun
    • Journal of the Korea Society for Simulation
    • /
    • v.20 no.3
    • /
    • pp.19-28
    • /
    • 2011
  • Adaptive Random Testing (ART) aims to enhance the performance of pure random testing by detecting failure region in a software. The ART algorithm generates effective test cases which requires less number of test cases than that of pure random testing. However, all ART algorithms currently proposed are designed for the tests of monolithic system or unit level. In case of integrated system tests, ART approaches do not achieve same performances as those of ARTs applied to the unit or monolithic system. In this paper, we propose an extended ART algorithm which can be applied to the integrated system testing environment without degradation of performance. The proposed approach investigates an input distribution of the unit under a test with limited number of seed input data and generates information to be used to resizing input domain partitions. The simulation results show that our approach in an integration environment could achieve similar level of performance as an ART is applied to a unit testing. Results also show resilient effectiveness for various failure rates.

A Study on the Conversion Method of CO2 Emission Unit of Automobiles (자동차 CO2 배출가스 배출단위 변환방법 고찰)

  • Han, JO;Kim, HT
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.2
    • /
    • pp.68-73
    • /
    • 2019
  • We proposed a method to convert the CO2 emission data of vehicles collected from the chassis dynamometer test from distance unit to energy unit which generally measured from the engine dynamometer tests. In the future, if engine dynamometer tests are limited, it is expected to be applied as an alternative method to calculate CO2 emission based on energy unit through the chassis dynamometer test. At this moment, engine efficiency is required and the test mode average efficiency should be used to improve the accuracy, not the result derived from specific speed and load conditions. Also, this method was applied to foreign data and the results were within 0.2%. However, CO, NOx and THC which have very low emission characteristics except CO2, are limited by the method proposed in this study and need to be considered separatively.

Production of Hepatotoxin by the Cyanobacterium Scytonema sp. Strain BT 23

  • Ashok, Kumar;Singh, D.P.;Tyagi, M.B.;Kumar, Arvind;Prasuna, E.G.;Thakur, J.K.
    • Journal of Microbiology and Biotechnology
    • /
    • v.10 no.3
    • /
    • pp.375-380
    • /
    • 2000
  • The preliminary screening of several cyanobacteria, using mice bioassay, reveale the production of a hepatotoxin by the cyanobacterium Scytonema sp. strain BT 23 isolated from soil. An intraperitoneal injection of the crude toxin (LD50 56 mg/kg body wt) from this strain caused the death of the mice within 40 min, and the anmals showed slinical signs of mice within 40 min, and the animals showed clinical signs of hepatotoxicity. The toxin was purified and partially characterized. The active fraction appears to be nonpolar in nature and shows absorption peaks at 240 and 285 nm. The purified toxin had an LD50 of TEX>$100<\mu\textrm{g}/kg$ body wt and the test mice died within 40 min of toxin administration. The toxin-treated mice showed a 1.65-fold increase in liver weight at 40 min and the liver color chnged to dark red due to intrahepatic hemorrhage and pooling of blood. Furthermore, the administration of the toxin to test mice induced a 2.58, 2.63, and 2.30-fold increse in the activity of the serum enzymes alanine aminotransferase, lactate dehydrogenase, and alkaline phosphatase, respectively. Further experiments with the 14C-labeled toxin revealed a maximum accumulation of the toxin in the liver. The clinical symptoms in the mice were similar to those produced by microcystin-L.R. These results suggest that hepatotoxins may also be produced in non bloom-forming planktonic cyanobacteria.

  • PDF

Analysis of rainfall infiltration characteristics for unsaturated soils using a column test equipment (모형실험장치를 이용한 불포화토의 강우 침투특성 분석)

  • Park, Kyu-Bo;Chae, Byung-Gon;Kim, Kyeong-Su
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.736-742
    • /
    • 2010
  • This study was conducted to characterize on the relationships of rainfall intensity and infiltration rate of rainfall dependent on unit weight change in the gneissic weathered soil by a column test equipment. In this study, volumetric water content and pore water pressure were measured using TDR sensors and tensiometers at regular time intervals. Rainfall conditions including continuous rainfall and repeated rainfall were selected in order to know the effect of antecedent rainfall. In the condition of rainfall intensity 20mm/h and the unit weights of soil as $1.35g/cm^3$, $1.55g/cm^3$ and $1.61g/cm^3$, average rainfall infiltration rate was $2.814{\times}10^{-3}cm/sec$, $1.969{\times}10^{-3}cm/sec$ and $1.252{\times}10^{-3}cm/sec$ respectively. The higher rainfall intensity and lower unit weight of soil, the faster average infiltration rate. Overflow in the column was happened except rainfall condition of rainfall intensity 20mm and soil unit weight $1.35g/cm^3$. Increasing the soil unit weight, overflowed water was increased and occurrence time was faster.

  • PDF

Insecticidal Efficacy of Porteresia coarctata (Roxb.) on Bio-chemical Alteration of Spodoptera litura (Fab.)

  • Bhattacharyya Atanu;Goswami Arunava;Dihidar Shankar;Adhikari Sujit;Banerjee Sudip Kumar;Talapatra Soumendra Nath;Barik Bikas Ranjan;Bhattacharya Subir Kumar;Chandra Asit Kumar
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.14 no.1
    • /
    • pp.9-13
    • /
    • 2007
  • Hexane extract of Porteresia coarctata (Roxb.) exhibits a toxic effect on the tissues of Spodoptera litura (F) while fed at the dose of 1000 and 2000 ppm thoroughly mixing with castor leaves (Ricinus communis L) after dissolving in DMSO at late fourth instar whereas only DMSO treated castor leaves were fed to control group. The larvae were put to rear at $28^{\circ}C{\pm}1^{\circ}C$, $76{\pm}4%$ R.H. under 12 L + 12 D photoperiodic regime. In test group insects substantial reduction of protein and DNA content was marked in fat body and midgut tissues compared to DMSO treated control group. The significant biochemical alterations in the midgut tissues and fat body of test group insects indicate the insecticidal property of the said plant extract that could be tested in facilitating the phenomenal stride in Integrated Pest Management.

Analysis of Vibration Parameters for the Fault Diagnosis of Reduction Unit for High-speed Train (고속철도차량 감속기 결함진단을 위한 진동 파라미터 분석)

  • Kim, Jae Chul;Ji, Hae Young;Lee, Kang Ho;Moon, Kyung Ho;Seo, Jung-Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.7
    • /
    • pp.679-686
    • /
    • 2013
  • The reduction unit is one of the most important components in railway cars, due to the transmission of torque from the motor to the wheels. Faulty reduction gears in high-speed trains result from excessive wear on the gear or damage to the gear. These types of gear defects have a significant effect on high-speed rail operation and safety; thus, a diagnosis system for the reduction unit is needed. Vibration diagnosis technology is one of the most effective diagnostics. In this paper, the vibration parameters of a reduction unit were evaluated during a driving-gear test and a full-vehicle test, using kurtosis and the crest factor. These tests were performed under normal operating conditions; a specimen tester was used to diagnose problems in defective gears.