• 제목/요약/키워드: Test Tool

검색결과 3,984건 처리시간 0.029초

색채동통척도의 신뢰도 연구 (Testing the Reliability of the Pain Color Circle Measurement Tool)

  • 김주희
    • 대한간호학회지
    • /
    • 제21권3호
    • /
    • pp.339-348
    • /
    • 1991
  • The study problem was to determine the reliability of the Stewart pain circle measurement tool with Korean subjects. The purpose was to assess the tool for potential use in research in Korea. The subjects were 95 primary school students and 103 university students in Seoul. The study was conducted from May to June 1990, using Stewart's pain color circle tool. To determine the difference in the rated intensity of the order of the pain color circles, statistical mean and standard deviation were employed. Item reliability and test - retest reliability were used to test for reliability. ANOVA and t-test were used to explore for differences in the rated intensity of the order of the pain color circles according to the subjects' general characteristics. The findings were as follows ; 1. Higher level pain intensity was assigned to color circle numbers 2, 4, and 6 (These contain large amounts of color). Lower level pain intensity was assigned to numbers 1, 3, and 5(These contain small amounts of color). Higher and lower levels of pain intensity selection patterns were the same as Stewart's but the highest rating of pain was different. The highest pain intensity rating was given to the color red in this study instead of black as in Stewart's test. 2. University students and primary school students' ratings were not very difteferent. 3. Pain color circle reliability was $\alpha$=0.3468, Test - retest reliability was supported (t=0.02~0.97, p=0.337~0.988) 4. Differences in the rating of the pain intensity order were related to the subjects' age and sex, but not to religion. It was concluded that the pain color circle measurement tool is worth for further study as a research instrument with both Korean adult and child clients for validity and reliability.

  • PDF

선반 및 밀링 겸용 다축 복합가공기의 정밀도 검증을 위한 표준공작물에 대한 연구 (A study on the test workpiece for accuracy analysis of multi-axis turning and milling center)

  • 신재훈;김홍석;윤재웅
    • 한국융합학회논문지
    • /
    • 제9권11호
    • /
    • pp.277-284
    • /
    • 2018
  • 최근 다축 가공을 통한 정밀가공의 수요가 크게 증대되고 있다. 그러나 5축 이상의 다축 공작기계는 기하학적 관계가 복잡하여 공작기계의 기하학적 정밀도 평가와 분석이 어렵다. 본 연구에서는 먼저, 여러 가지 규정으로 분산되어 있는 KS/ISO 규격을 정리하여 다축 공작기계의 기하학적 정밀도 평가 항목을 체계화하였다. 또한, 다축 공작기계의 정밀도를 평가하고 분석하기 위해 표준공작물을 제안하였고, 표준 공작물을 사전에 정해진 방법과 절차에 따라 가공한 후, 가공면을 3차원 측정하여 분석하였다. 그 결과 표준공작물의 가공 결과와 공작기계의 정밀도가 정성적 및 정량적으로 매우 유사함을 확인하였다. 이 결과로부터 다축 공작기계의 정밀도 분석이 표준공작물의 가공만으로 가능함을 확인할 수 있었다.

융합적 문제해결력 검사 도구 (Development of a Convergence Problem Solving Skill Test Tool)

  • 이동영;윤진아;남윤경
    • 한국지구과학회지
    • /
    • 제41권6호
    • /
    • pp.670-683
    • /
    • 2020
  • 본 연구의 목적은 융합적 문제해결력을 검사할 수 있는 도구를 개발하는 것이다. 이를 위해 먼저 선행연구에서 다양하게 정의된 융합적 문제해결력의 영역들을 융합적 성향, 융합적 사고, 융합적 소양 영역 측면으로 정의하였다. 37개의 예비문항은 문제해결과 융합적 사고, 창의적 사고, 개인적 성향과 사회적 성향, 그리고 융합적 소양을 포함한 각 영역에 대한 선행연구에 근거하여 정의된 하위 영역에 근거하여 개발되었다. 탐색적 요인분석을 통해 30개의 예비 문항이 확정 되었다. 확인적 요인 분석 결과는 확정된 5개 요인 모델이 문항수준에서 적합한 요인구조를 가지고 있다는 것을 보여준다. 측정된 모든 문항과 요인에 대한 신뢰도 검정 결과 검사도구 전체의 Cronbach's α값은 .963으로 매우 양호한 것으로 나타났다. 따라서 본 연구에서 개발된 융합적 문제해결 검사 도구는 통계적으로 신뢰롭다고 할 수 있다.

패킷 필터링 기능 테스트를 위한 테스트 도구 개발 (Development of Test Tool for Testing Packet Filtering Functions)

  • 김현수;박영대;국승학
    • 한국정보과학회논문지:컴퓨팅의 실제 및 레터
    • /
    • 제13권2호
    • /
    • pp.86-99
    • /
    • 2007
  • 패킷 필터링이란 악의적인 네트워크 패킷들을 거르는 작업을 말한다. 패킷 필터링의 기능을 테스트하기 위해서는 구축된 보안 정책이 의도했던 대로 정확하게 동작하는가를 검증하여야 한다. 그러나 이런 기능을 테스트하기 위한 도구들은 많지 않으며, 테스트 과정에서 많은 사용자의 노력을 요구한다. 대부분의 보안 관리자들은 보안 정책을 새로 수립하거나 기존의 보안 정책을 수정할 때에 새로운 보안 정책을 체계적으로 테스트하는 것에 부담을 느낀다. 이런 부담을 경감해주기 위해 우리는 사용자의 참여를 최소화하는 새로운 테스트 방법을 제안한다. 제안하는 방법은 테스트 케이스와 테스트 오라클의 생성을 자동화한다. 자동으로 생성된 테스트 케이스는 테스팅 과정의 입력 요소를 선택해야 하는 고민을 덜어주며, 자동으로 생성된 테스트 오라클은 사용자의 도움 없이 테스트 결과에 대한 판단을 가능하게 한다. 우리의 테스트 방법을 구현한 테스트 도구는 테스트 수행의 전체 4단계 중 테스트 준비, 테스트 실행, 테스트 평가의 3단계에 걸쳐 테스트 자동화를 실현하고 있다. 이런 테스트 도구 위에서 테스팅을 수행하게 된다면 결과적으로 테스트 활동의 신뢰도를 보다 높게 향상시킬 수 있다. 이 논문은 우리의 테스트 방법과 테스트 도구의 설계 및 구현에 관한 내용을 기술한다.

DEVELOPMENT OF AN IMPROVED FARE TOOL WITH APPLICATION TO WOLSONG NUCLEAR POWER PLANT

  • Lee, Sun Ki;Hong, Sung Yull
    • Nuclear Engineering and Technology
    • /
    • 제45권2호
    • /
    • pp.257-264
    • /
    • 2013
  • In Canada Deuterium Uranium (CANDU)-type nuclear power plants, the reactor is composed of 380 fuel channels and refueling is performed on one or two channels per day. At the time of refueling, the fluid force of the cooling water inside the channel is exploited. New fuel added upstream of the fuel channel is moved downstream by the fluid force of the cooling water, and the used fuel is pushed out. Through this process, refueling is completed. Among the 380 fuel channels, outer rows 1 and 2 (called the FARE channel) make the process of using only the internal fluid force impossible because of the low flow rate of the channel cooling water. Therefore, a Flow Assist Ram Extension (FARE) tool, a refueling aid, is used to refuel these channels in order to compensate for the insufficient fluid force. The FARE tool causes flow resistance, thus allowing the fuel to be moved down with the flow of cooling water. Although the existing FARE tool can perform refueling in Korean plants, the coolant flow rate is reduced to below 80% of the normal flow for some time during refueling. A Flow rate below 80% of the normal flow cause low flow rate alarm signal in the plant operation. A flow rate below 80% of the normal flow may cause difficulties in the plant operation because of the increase in the coolant temperature of the channel. A new and improved FARE tool is needed to address the limitations of the existing FARE tool. In this study, we identified the cause of the low flow phenomena of the existing FARE tool. A new and improved FARE tool has been designed and manufactured. The improved FARE tool has been tested many times using laboratory test apparatus and was redesigned until satisfactory results were obtained. In order to confirm the performance of the improved FARE tool in a real plant, the final design FARE tool was tested at Wolsong Nuclear Power Plant Unit 2. The test was carried out successfully and the low flow rate alarm signal was eliminated during refueling. Several additional improved FARE tools have been manufactured. These improved FARE tools are currently being used for Korean CANDU plant refueling.

국내외 보급형 소방용 보호장갑의 동작성 평가 -착탈 시험, 기민성 시험, 회전력 시험을 중심으로- (Mobility Evaluation of Popular Firefighting Protective Gloves in Domestic and Foreign Countries -Don-Doff Test, Dexterity Test, and Torque Test-)

  • 김다미;이인성;이주영
    • 한국의류학회지
    • /
    • 제40권5호
    • /
    • pp.921-935
    • /
    • 2016
  • This research analyzed the manual performance of firefighting protective gloves on global markets in order to suggest an evaluation method for firefighting protective gloves wearing comfort. We collected 13 types of firefighting gloves from domestic and international markets (7 types from Korea, 3 types form Europe, 2 types from the U.S and 1 type from Japan). We set the Don-Doff test as a basal requirement for moving toward to further manual performance tests that consist of: ASTM dexterity test, Minnesota dexterity test, Bennett hand tool test and ASTM torque test. All gloves were evaluated in dry and wet conditions, we included eight current male firefighters ($43.4{\pm}7.0yr$ in age, $173.1{\pm}4.4cm$ in height, $79.9{\pm}9.2kg$ in body mass) for the tests. Four gloves (1 Korea, 1 U.S, 1 Germany, and 1 Japan) out of thirteen firefighting gloves passed the Don-Doff test and had great subject preferences. There was no significant difference between dry and wet conditions on the ASTM dexterity test, Minnesota dexterity test, Bennett hand tool test and ASTM torque test. However, Japanese gloves had the greatest score and showed 3-4 times faster completion time on the ASTM dexterity test (p<.05), 1.2-1.5 times faster on the Minnesota dexterity test (p<.05), as fast as the bare hand on Bennett hand tool test (p<.05), and greater performance on the ASTM torque test compared to bare hand. In conclusion, Don-Doff test in wet conditions should be the first step for a mobility evaluation of domestic firefighting protective gloves; subsequently, a comprehensive test assorting ASTM, Minnesota, and Bennett test should be developed as a second step. The current ASTM torque test can be adopted as a third step. This three-step-method for evaluating firefighting protective glove mobility can be expected to expand into surveys of other safety gloves in Korea.

다단계 스택 지향 포인터가 있는 프로그램 테스트를 위한 테스트 데이터 자동 생성 (Automated Test Data Generation for Testing Programs with Multi-level Stack-directed Pointers)

  • 정인상
    • 정보처리학회논문지D
    • /
    • 제17D권4호
    • /
    • pp.297-310
    • /
    • 2010
  • 최근에 콘콜릭 테스트이라 불리는 새로운 테스팅 방법이 많은 관심을 받고 있다. 콘콜릭 테스팅은 높은 테스트 커버리지를 달성하기 위해 실제 프로그램 수행과 심볼릭 수행을 결합하여 테스트 데이터를 생성한다. CREST는 콘콜릭 테스팅을 구현한 대표적인 open-source 테스트 도구이다. 그러나 현재 CREST는 입력으로 정수형만 다룬다. 이 논문은 포인터형인 입력이 존재하는 경우에 자동 테스트 데이터 생성을 위한 새로운 규칙을 제안한다. 이 규칙들은 C 프로그램에서 주로 사용되는 다단계 스택 지향 포인터를 효과적으로 처리한다. 또한, 이 논문에서는 제안 된 규칙을 구현한 vCREST라 불리는 도구에 대해 기술하고 C 프로그램에 적용한 결과도 함께 기술한다.

로봇 소프트웨어 컴포넌트를 위한 시뮬레이션 기반 인터페이스 테스팅 자동화 도구 (SITAT: Simulation-based Interface Testing Automation Tool for Robot Software Component)

  • 강정석;최형섭;맹상우;김시완;박홍성
    • 제어로봇시스템학회논문지
    • /
    • 제16권6호
    • /
    • pp.608-616
    • /
    • 2010
  • Robot software components can be categorized into two types; the pure S/W component and the H/W-related one. Since interface testing of the robot software component is the labour-intensive and complicated work, an effective automated testing tool is necessary. Especially it is difficult to test all types of H/W-related components because it is hard work to prepare all H/W modules related to them. This paper proposes a new simulation-based interface testing automation tool(SITAT) which generates automatically test cases for interface testing of the robot software component and executes the interface test with the generated test cases where the simulator is used for simulation of the activity of a H/W module instead of the real H/W module. This paper verifies the effectiveness of the suggested SITAT with testing of the real H/W-related robot software component.

Test-retest reliability of the questionnaire in the Sasang constitutional analysis tool (SCAT)

  • Lee, Jeongyun;Yim, Mi Hong;Kim, Jong Yeol
    • Integrative Medicine Research
    • /
    • 제7권2호
    • /
    • pp.136-140
    • /
    • 2018
  • Background: The Sasang constitutional analysis tool (SCAT) is an integrated Sasang constitutional analysis system developed by the Korea Institute of Oriental Medicine. This study aimed to evaluate the reliability of a questionnaire for measuring personality and pathophysiological symptoms that is one of the components of the SCAT. Methods: In this study, data were collected from university students in their twenties. Tests were administered twice, with an interval of 4 weeks between tests. Test-retest data from 176 students were collected and used for analysis. Internal consistency reliability was analyzed by using Cronbach's alpha coefficient, and test-retest reliability was analyzed by using Spearman's rank correlation coefficient. Results: Cronbach's alpha coefficient was 0.788 for personality, 0.511 for eating habits, 0.718 for digestion, 0.667 for heat- or cold-wise penchant, and 0.612 for water ingestion. Spearman's rank correlation coefficients, which were used to assess correlations between test and retest results, ranged from 0.444 to 0.828. Conclusion: The internal consistency and test-retest reliability of the SCAT questionnaire were found to be satisfactory.

보행기호잇기검사: 새로운 신체 및 인지 기능에 대한 이중 과제 평가도구로서의 효용성에 대한 예비연구 (Stepping Trail Making Test: Preliminary Study for the Effectiveness of the Novel Dual Task Assessment Tool for Physical and Cognitive Functions in Elderly )

  • 엄주리;이병주
    • 대한물리의학회지
    • /
    • 제18권2호
    • /
    • pp.41-48
    • /
    • 2023
  • PURPOSE: Falls are caused by a decline in physical and cognitive function. A quantitative evaluation tool that can comprehensively evaluate motor and cognitive functions for elderly people with an impaired physical function. This study assessed the clinical application potential by confirming the correlation between the physical function tests, cognitive and the stepping trail-making test (S-TMT). METHODS: Fourteen community-dwelling older patients (65-75 years) were recruited. The study conducted cognitive function tests with the trail-making test (TMT-A, B), and physical function tests (6-minute walking test (6MWT), short physical performance battery (SPPB), and timed up and go (TUG)). The results of were analyzed using SPSS version 21.0. Descriptive statistics were used for the general characteristics of the study subjects, and the correlations between S-TMT, other functional tests were examined through Pearson's correlation analysis. The statistical significance was set to .05. RESULTS: S-TMT had a significant positive correlation with the TUG (r = .588*) and trail-making test-B (TMT-B) (r = .689*, p < .05). Furthermore, S-TMT showed a negative correlation between SPPB (r = -.397) and 6MWT (r = -.422), but it was not statistically significant. CONCLUSION: S-TMT is a cognitive-gait dual-task performance evaluation tool that can be performed safely. A significant correlation was confirmed between the TUG test and the TMT-B. S-TMT is a dual-task screening tool that can evaluate both physical and cognitive functions simultaneously.