• Title/Summary/Keyword: Test Temperature

Search Result 10,040, Processing Time 0.04 seconds

Effect of Curing Temperature and Time on Measuring Fundamental Properties of Asphalt Mixture (양생온도 및 시간이 아스팔트 혼합물의 기초특성치 측정에 미치는 영향)

  • Kim, Kwang-Woo;Hong, Sang-Ki;Oh, Heung-Lak;Lee, Soon-Jae
    • International Journal of Highway Engineering
    • /
    • v.4 no.4 s.14
    • /
    • pp.13-21
    • /
    • 2002
  • This study examines the importance of conditioning temperature and period before measuring fundamental properties of asphalt mixture. Marshall specimens were made and cured in the air for one day and conditioned by submerging at $60^{\circ}C$ water for 30 min before loading. It was observed that if the specimen was cured in a lower (or higher) than normal lab temperature ($25^{\circ}C$) before submerging, the measured values were not consistent. Indirect tensile strength (ITS) was also measured on the specimens cured at different temperatures. Although there is no regulation specifying how long the specimen should be conditioned before testing, it is recommended that the conditioning time be for the specimen to be at $25^{\circ}C$. Test must be conducted for the specimen cured well before conditioning for desired test. If curing temperature was lower or higher than normal, and mixture was not properly cured, then test results would not be reliable. This study showed how long the specimen should be submerged at $60^{\circ}C$ for Marshall test and conditioned at $25^{\circ}C$ for ITS test for the specimens cured in different temperature.

  • PDF

Thermal Shock Tests and Thermal Shock Parameters for Ceramics

  • Awaji, Hideo;Choi, Seong-Min
    • Journal of the Korean Ceramic Society
    • /
    • v.49 no.4
    • /
    • pp.385-396
    • /
    • 2012
  • Thermal shock test methods and thermal shock parameters for ceramics were reviewed from the following viewpoints: (1) The test methods should be based on the precise estimation of both temperature and thermal stress distributions in a specimen taking into account the temperature-dependent thermo-mechanical properties; (2) The thermal shock parameters must be defined as a physical property of the materials and described as a function of temperature at the fracture point of the specimen; (3) The relation between the strength and fracture toughness of brittle ceramics under a thermal shock load must be the same as the relation under a mechanical load. In addition, appropriate thermal shock parameters should be defined by the thermal shock strength and thermal shock fracture toughness based on stress and energy criteria, respectively. A constant heat flux method is introduced as a testing technique suitable for estimating these thermal shock parameters directly from the electric power charged.

Behavior of FRP bonded to steel under freeze thaw cycles

  • Toufigh, Vahab;Toufigh, Vahid;Saadatmanesh, Hamid
    • Steel and Composite Structures
    • /
    • v.14 no.1
    • /
    • pp.41-55
    • /
    • 2013
  • Fiber reinforced polymers (FRP) materials are increasingly being used for strengthening and repair of steel structures. An issue that concerns engineers in steel members which are retrofitted with FRP is stress experienced due to temperature changes. The changing temperature affects the interface bond between the FRP and Steel. This research focused on the effects of cyclical thermal loadings on the interface properties of FRP bounded to steel members. Over fifty tests were conducted to investigate the thermal effects on bonding between FRP and steel, which were cycled from temperature of $-11^{\circ}C$ ($12^{\circ}F$) to $60^{\circ}C$ ($140^{\circ}F$) for 21-36 days. This investigation consisted of two test protocols, 1) the tensile test of epoxy resin, tack coat, FRP and FRP-steel plate, 2) tensile test of each FRP compound and FRP with steel after going through thermal cyclic loading. This investigation reveals an extensive reduction in the composite's strength.

Effect of Annealing on the Improvement of Strength of Butt Welded Joint (맞대기 이음용접의 강도향상을 위한 어니일링 효과에 관한 연구)

  • ;;Shin, Keun-Ha
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.3 no.2
    • /
    • pp.43-47
    • /
    • 1979
  • This paper presents the effect of stress relief annealing on mechanical properties in single Vee-groove welding joint. In this experiment, the investigation of annealing effect on mechanical properties of test material carried out by changing the annealing temperature from $600^{\circ}C$ to $900^{\circ}C$ under the given conditions. The results pbtained by this study are as follows: (1) Under the constant welding conditions, the tensile strength of test welded joint decrease in accordance with the increase of annealing temperature. The experimental results show that the reduction rate of tensile strength is about 35.09% of base metal strength. (2) Microhafdness distribution of welded joint bring about the maximum hardness near the bended line of welding joint. (3) Izod impact energy of welded joint in increase in according to the rise of annealing temperature and the peak energy of impact test occurs at $800^{\circ}C$

A Study on Determination for Mixture Lever's Position by Flight Test (비행시험을 통한 엔진의 혼합기레버 위치 설정에 관한 연구)

  • Kim, Jin-Gon;Kim, Chil-Yeong;Lee, Jeong-Mo;Lee, Jeong-Hun
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.3 no.1
    • /
    • pp.37-47
    • /
    • 1995
  • It is very important to determine the performance and operating envelope of engine for aircraft's flight. The basic performance is provided by manufacturer, but installed engine's operating envelop is only determined by flight test. First, this study was measured cylinder head temperature(CHT), exhaust gas temperature(EGT) and oil temperature. At pre-determined altitude and power rate, these temperatures were measured by change of mixture ratio and mixture ratio condition for economic operation and max. power were found. And secondly, with the measured temperatures, possible positions of mixture lever were determined by flight test for stable flight Chang-91 and Lycoming IO-360-A series four cylinders engine with 200 hp was used for this study.

  • PDF

A Study on Thermosonic Bonding Process and Its Reliability Evaluation of Joints (열초음파 접합 공정과 접합부의 신뢰성 평가에 관한 연구)

  • Shin, Young-Eui;Pak, Jin-Suk;Son, Sun-Eik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.8
    • /
    • pp.625-631
    • /
    • 2009
  • In this thesis, lateral thermosonic bonding with ACFs was investigated as a process to make high reliability joints for FPD fabrication. Conditions for thermosonic and thermocompression bonding with ACFs were determined and used to make specimens in a driving test jig for testing of bond reliability by thermal shock. The results showed that thermosonic bonding temperature of $199\;^{\circ}C$ and bonding time of 1s produced bonds with good reliability. Additionally, thermosonic bonding temperature and time were reduced and thermal shock test results compared to this proposed curing condition. It is concluded that theromosonic bonding with ACFs can be effectively applied to reduce bonding temperature and time compared with that of thermocompression bonding.

A Study on Thermal Stress in T/G Wall of Containment Building (격납건물 텐던갤러리 벽체의 온도응력에 대한 연구)

  • 김진근;양은익;박영진;송영철;방기성
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04a
    • /
    • pp.193-198
    • /
    • 1998
  • In this study, the change of concrete temperature, strain and thermal stress were measured by using the embedded type concrete gauges in tendon gallery wall of containment building. A finite element analysis was performed to clarify the thermal behavior of concrete. The analytic and test results were investigated to improve the validity of analytic method. According to the test results, concrete temperature, strain and thermal stress were strongly affected by measuring point and environment condition of member. And the thermal stress was developed in the member which was not demoulded at early ages. This is caused by the change of internal temperature and restrained condition. A finite element effectively interpreted the test results by estimating the concrete properties and the site condition.

  • PDF

Analysis on Thermo-Mechanical Characteristics of Underground Cable Termination (지중송전케이블 종단접속함 Thermo-Mechanical 특성 분석)

  • Jung, Chae-Kyun;Kang, Ji-Won;Park, Hung-Sok;Kim, Du-Jin;Roh, Tae-Hyueng;Yoon, Jong-Keon
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.365-366
    • /
    • 2015
  • This paper describes the analysis on thermo-mechanical characteristics of underground cable termination. Specially, the interface pressures between stress relief cone and XLPE insulation were analysed according to the change of conductor temperature and ambient temperature. This interface pressures were measured by real test with current transformer and chamber and the interface pressure was changed with conductor and ambient temperature. This paper will continue to perform the test with various cases, then the relation between low interface pressure and breakdown will prove with test results in the near future.

  • PDF

High-temperature Mechanical Properties Measurement and Life Assessment of Boiler Equipment by Instrumented Indentation Technique (계장화 압입시험법을 이용한 보일러 설비의 고온 기계적 물성 측정과 수명 평가)

  • Ro, Dong-Seong;Hong, Jeong-Wha;Kim, Kwang-Ho;Lee, Jung-Jun
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.3
    • /
    • pp.1-6
    • /
    • 2009
  • Recently power plants and oil refineries are focusing on capacity enlargement for better efficiency through higher temperature and higher pressure. Thickness of boiler tubes becomes lessened due to oxidation and erasion caused by high temperature bums gas flowing over tubes outside. Accordingly, mechanical stress of tubes is increasing and that is a critical factor to make a crack and fracture. To prevent those sorts of accidents, aging assessment for proper periodic repair and replacement should be conducted reliably and reasonably. We performed IIT test on Cr-Mo steel, one of the most heat-resistant materials for facilities in power plants, and we report the test result and the considerable effectiveness of IIT test.

Aerodynamic Heating Test of Payload Fairing of KSLV-I (KSLV-I 페어링 공력 가열 시험)

  • Choi, Sang-Ho;Kim, Seong-Lyong;Kim, In-Sun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.448-451
    • /
    • 2008
  • KARI is developing a satellite launch vehicle that is called KSLV(Korea Space Launch Vehicle)-I. During the flight, launch vehicles are exposed to aerodynamic heating conditions while flying at high Mach numbers in the atmosphere. KARI constructed Aerodynamic Thermal Simulation Facility to simulate aerodynamic heating on the ground. ATSF is a facility that can simulate given temperature profile using about 4,000 halogen heaters on fairing model. Aerodynamic heating profile is got from result of thermal analysis using MINIVER, Thermal Desktop, and SINDA/FLUINT. Aerodynamic heating test of fairing of KSLV-I was done using engineering model of payload fairing and Aerodynamic Thermal Simulation Facility. It was found that thermal analytic results show good agreement with aerodynamic heating test results within 6$^{\circ}$C at fairing inner surface. Also it was confirmed that maximum temperature of fairing nose-cone inner surface during flight is lower than allowable temperature limit.

  • PDF