• Title/Summary/Keyword: Test Temperature

Search Result 10,026, Processing Time 0.033 seconds

Reliability Testing and Materials Evaluation of Si Sub-Mount based LED Package (실리콘 서브 마운틴 기반의 LED 패키지 재료평가 및 신뢰성 시험)

  • Kim, Young-Pil;Ko, Seok-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.4
    • /
    • pp.1-10
    • /
    • 2015
  • The light emitting diodes(LED) package of new structure is proposed to promote the reliability and lifespan by maximize heat dissipation occurred on the chip. We designed and fabricated the LED packages mixing the advantages of chip on board(COB) based on conventional metal printed circuit board(PCB) and the merits of Si sub-mount using base as a substrate. The proposed LED package samples were selected for the superior efficiency of the material through the sealant properties, chip characteristics, and phosphor properties evaluations. Reliability test was conducted the thermal shock test and flux rate according to the usage time at room temperature, high-temperature operation, high-temperature operation, high-temperature storage, low-temperature storage, high-temperature and high-humidity storage. Reliability test result, the average flux rate was maintained at 97.04% for each items. Thus, the Si sub-mount based LED package is expected to be applicable to high power down-light type LED light sources.

Temperature Effect on Tensile Strength of Filled Natural Rubber Vulcanizates (가황 천연고무의 인장강도에 미치는 온도의 영향)

  • Ko, Young-Chon;Park, Byung-Ho
    • Elastomers and Composites
    • /
    • v.36 no.4
    • /
    • pp.255-261
    • /
    • 2001
  • This study was related with the effect of elevated temperature on the tensile strength of edge-cut samples. There was a different tensile strength behavior of uncut samples and pre-cut samples under different test temperatures. Tensile strength of uncut sample decreases with increasing test temperature. When pro-cut size(C) is larger than critical cut size($C_{cr}$), tensile strength or pre-cut specimen at $80^{\circ}C$ is higher than that of pre-cut specimen at room temperature (RT). Test specimens under $80^{\circ}C$ condition exhibited more secondary cracks at the crack tip region compared to room temperature conditions. However, secondary cracks of pre-cut specimens are not clearly developed at $110^{\circ}C$. Differences in tensile strength induced by different test temperature seem to be responsible for the strain-induced crystallization and micro-cracking patterns.

  • PDF

Theoretical and Experimental Considerations of Thermal Humidity Characteristics

  • Choi, Seok-Weon;Cho, Ju-Hyeong;Seo, Hee-Jun;Lee, Sang-Seol
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.3 no.1
    • /
    • pp.9-18
    • /
    • 2002
  • Thermal humidity characteristics were considered theoretically and experimentally. A Simply well-fitted correlation of a saturated vapor pressure-temperature curve of water was introduced based on Antoine equation to make theoretical prediction of relative humidity according to temperature variation. Characteristics of dew point were also examined theoretically and its relation with temperature and humidity was evaluated. The exact mass of water vapor in a specified humidity and temperature condition was estimated to provide useful insight into the idea about how much amount of water corresponds to a specified humidity and temperature condition in a confined system. A simple but well-fitting model of dehumidification process was introduced to anticipate the trend of relative humidity level during GN2(gaseous nitrogen) purge process in a humidity chamber. Well-suitedness of this model was also verified by comparison with experimental data. The overall appearance and specification of two thermal humidity chambers were introduced which were used to perform various thermal humidity tests in order to yield useful data necessary to support validity of theoretical models.

DETERMINATION OF RUPTURE TIME AND STRAIN RATE IN CREEP BY UNIAXIAL TENSILE TEST

  • Oh, Hung-Kuk
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1994.10a
    • /
    • pp.74-79
    • /
    • 1994
  • The log-log presentation of stress versus Larson-Miller parameter is obtained by uniaxial tensile test instead of the long time creep test. The used material for example calculations is SUS304 stainless steel. The temperature of the uniaxial tensile test can be determined by the Larson-Miller parameter of the design stress and the 0.1hr's rupture time of the uniaxial tensile test. The rupture time at the design temperature and stress can be determined by the Larson-Miller parameter of the stress. The average creep rate is the total deformation of the tensile test divided by the rupture time at the design stress and temperature. The liner trend and the order of the data of the average creep rate by this method is almost same as that of experimental results.

  • PDF

Evaluation of the Tensile Properties of Fuel Cladding at High Temperatures Using a Ring Specimen (링 시험편을 이용한 피복관의 고온 인장특성 평가)

  • Bae Bong-Kook;Koo Jae-Mean;Seok Chang-Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.4 s.235
    • /
    • pp.600-605
    • /
    • 2005
  • In this study, the ring tensile test at high temperature was suggested to evaluate the hoop tensile properties of small tube such as the cladding in the nuclear reactor Using the Arsene's ring model, the ring tensile test was performed and the test data were calibrated. From the result of the ring test with strain gauge and the numerical analysis with 1/8 model, LCRR(load-displacement conversion relationship of ring specimen) was determined. We could obtain the hoop tensile properties by means of applying the LCRR to the calibrated data of the ring tensile test. A few difference was observed in view of the shape of fractured surface and the fracture mechanism between at the high temperature and at the room temperature.

Application of Advanced Indentation System for Evaluati Tensile Property Degradation of Cr-Mo Steel (Cr-Mo 강의 열화도 평가를 위한 Advanced Indentation System의 응용)

  • Jang, Jae-Il;Choi, Yoel;Lee, Yun-Hee;Kwon, Dong-Il;Kim, Jeoung-Tae
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.231-236
    • /
    • 2001
  • A newly developed Advanced Indentation System (AIS), which is a portable and nondestructive system for evaluating tensile properties, was used to measure mechanical behavior of materials used under high temperature and pressure conditions. This test measures indentation load-depth curve during indentation and analyzes the mechanical properties related to deformation and fracture. Aging effects of Cr-Mo and Cr-Mo-V steel at high temperature were simulated. Tensile properties including yield strength and tensile strength at various temperature are obtained from the test. For all test materials and conditions, the AIS-derived results were in good agreement with those from conventional standard test method. Examples of the test results ate given and potential applications of the AIS to assess the integrity of aging structures are briefly discussed.

  • PDF

THERMAL SYSTEM DESIGN FOR A LARGE SPACE $SIMULATOR(\Phi8m\;\times\;L10m)$

  • Moon Guee-Won;Cho Chang-Lae;Cho Hyokjin;Lee Sang-Hoon;Seo Hee-Jun;Choi Seok-Weon
    • Bulletin of the Korean Space Science Society
    • /
    • 2004.10b
    • /
    • pp.281-284
    • /
    • 2004
  • According to the National Space Program of Korea, KARI (Korea Aerospace Research Institute) has been developing a large space simulator (working dimension; $\Phi8m\;\times\;L10m$) to verify the performance of future large satellites under the space environment conditions. Especially, a very low temperature condition of space will be simulated by shrouds covering the inside surface of the vessel. The surface of shrouds will be cooled down to 17K by liquid nitrogen (LN2) from ambient temperature and hence, an optimal LN2 circulation system design is necessary to remove gaseous nitrogen (GN2) sufficiently and maintain the shrouds at the LN2 temperature.

  • PDF

Thermal environmental performance evaluation of 4kW power electronic cooling system for commercial vehicle (4kW급 상용차량용 전력전자 냉방장치의 열 환경 성능평가)

  • Han, Keun-Woo;Kim, Seong-Gon;Lee, Chung-Hoon;Choi, Myoung-Hyun;Jung, Young-Gook
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.290-291
    • /
    • 2017
  • This study deals with an evaluation method for testing the robustness of the 4 kW commercial power electronic cooling system to the thermal environment. The power electronic cooling system consists of a cascaded push-pull DC / DC converter, a three-phase DC / AC inverter, and an electric compressor. The system manufactured by the thermal environment evaluation test (heat distribution test, thermal impact test, high temperature operation test, temperature cycle test, low temperature operation test) for the commercial electric power cooling system for commercial vehicle proves that it is robust against thermal environment.

  • PDF

Uncertainty Analysis of Test Method for Heat Recovery Ventilators (폐열회수 환기유닛의 인증시험 방법에 대한 오차분석)

  • Han, H.;Choo, Youn-Bok
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.423-428
    • /
    • 2006
  • Twenty nine HRV models have been tested for last two years since the attestation system has been started by KARSE. It is the objective of the present study to analyze the performance test results. Uncertainty analysis has been conducted to find the effects of measured variables on the uncertainties of test results. The uncertainty of enthalpy is found to be affected by the uncertainty of wet bulb temperature significantly, but not by that of dry bulb temperature for the present range of parameters. The uncertainty of effective enthalpy efficiency is calculated to be 6%P for the cooling condition, and 3%P for the heating condition approximately. In order to reduce the uncertainty of the test results, the uncertainty of wet bulb temperature should be minimized and the indoor/outdoor test conditions should be modified so as to increase the enthalpy difference.

  • PDF

A study on OLED device's accelerated lifetime test (OLED 소자의 가속수명 시험에 관한 연구)

  • Choi, Young-Tae;Joe, Jae-Rib
    • Journal of the Korea Safety Management & Science
    • /
    • v.10 no.3
    • /
    • pp.73-79
    • /
    • 2008
  • Display's life time is defined as the time of 50% luminance drop. It was used luminance and temperature as accelerated factor to accelerated lifetime at test. When it's working jule-heat is generated and device's temperature is growing as any temperature because OLED is self-luminance display device. So we decided temperature condition is 25, $70^{\circ}C$, and luminance condition is $60{\sim}300cd/m^2$ in test. It's assumed accelerated lifetime model by result of the test.