• 제목/요약/키워드: Test Temperature

검색결과 10,040건 처리시간 0.035초

저온 태양열을 이용한 생물학적 오수 처리 장치 실증 실험 (Field Test for a Biological Nitrogen Treatment System with Low Temperature Solar Thermal Energy)

  • 정모;이동원
    • 한국태양에너지학회 논문집
    • /
    • 제28권2호
    • /
    • pp.34-41
    • /
    • 2008
  • A low-temperature solar thermal system assisting a biological nitrogen treatment reservoir was designed and field-tested. A large tank whose temperature was maintained at about $25-30^{\circ}C$ to enhance the performance of a biological nitrogen treatment process was heated by an array of flat plate solar collectors. Test results revealed that the overall collector efficiency was above 50% for the most cases tested. This high efficiency was possible owing to the relatively low collector temperature that can be traced back to the reservoir temperature. A substantial enhancement in nitrogen treatment was observed as a result of maintaining the reservoir temperature higher.

양생온도 변화가 고성능 콘크리트의 압축강도에 미치는 영향에 관한 연구 (A Study on the Effects of Curing Temperature for Compressive Strength of High Performance Concrete)

  • 노인철
    • 한국건축시공학회지
    • /
    • 제2권4호
    • /
    • pp.163-168
    • /
    • 2002
  • The object of this study is to define the characteristics of high performance concrete with varing compressive strength of concrete and curing temperature. The major test variables are 1) high strength concrete(500kg/$cm^2$) and ordinary strength concrete(240kg/$cm^2$) compressive strength, 2) curing temperature and condition, 3) concrete curing age, 4) three types of cement. From the test results were shown that curing temperature and curing conditions were also very effective for high strength concrete and ordinary strength concrete, and concrete were largely effected by cement type and temperature during the hydration reaction process. This paper describes the effect of curing temperature for strength and characteristics of high performance concrete.

주상용 몰드변압기의 온도분포와 열응력 해석 (The Temperature Distribution and Thermal Stress Analysis of Mold transformer)

  • 조한구;이운용;한세원
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.387-390
    • /
    • 2000
  • The life of transformer is significantly dependent on the thermal behavior in windings. To analyse winding temperature rise, many transformer designer have calculated temperature distribution and hot spot point by finite element method(FEM). Recently, numerical analyses of transformer are studied for optimum design, that is electric field analysis, magnetic field, potential vibration, thermal distribution and thermal stress. Therefore design time and design cost are decreased by numerical analysis. In this paper, the temperature distribution and thermal stress analysis of 50kVA pole cast resin transformer for power distribution are investigated by FEM program. The temperature change according to load rates of transformer also have been investigated. We have carried out temperature rise test and test results are compared with simulation data.

  • PDF

소듐 시험루프 내 소듐대 공기 열교환기의 고온 설계 (High-Temperature Design of Sodium-to-Air Heat Exchanger in Sodium Test Loop)

  • 이형연;어재혁;이용범
    • 대한기계학회논문집A
    • /
    • 제37권5호
    • /
    • pp.665-671
    • /
    • 2013
  • 제 4 세대 소듐냉각 고속로에는 중간열교환기(IHX), 붕괴열제거 열교환기(DHX), 공기 열교환기(AHX), 핀형 소듐-공기 열교환기(FHX) 및 증기발생기(SG)를 포함한 다양한 열교환기들이 설치된다. 본 연구에서는 STELLA-1 시험루프에 설치된 소듐-공기 열교환기인 AHX 와 SELFA 시험루프에 설치될 핀형(finned) 소듐-공기 열교환기인 FHX 등 2 기의 열교환기 설계에 대해 3D 상세 유한요소해석을 수행하고, 동 결과에 기초하여 고온설계 기술기준을 따라 크리프-피로 손상평가를 수행하였다. 손상 평가결과 AHX와 FHX는 의도하는 크리프 피로 손상 하중 하에서 구조 건전성을 유지하는 것으로 확인되었다.

주조/단조 공정에서 Al6061의 단조효과에 관한 연구 (Forging Effect of Al6061 in Casting/Forging Process)

  • 권오혁;배원병;조종래
    • 한국정밀공학회지
    • /
    • 제22권11호
    • /
    • pp.45-50
    • /
    • 2005
  • In this study, the casting/forging process was applied in manufacturing a low control arm, in order to prove that application of casting/forging process to Al6061 is likely to get the effect of light weight compared with existing steel products and to reduce the cost of materials. Firstly, In order to set up the optimum casting condition of the forging material, Al6061, casting experiments were carried out by controlling pouring temperature of the aluminum for casting, mold temperature, and pouring time. $700^{\circ}C$ pouring temperature, $300^{\circ}C$ mold temperature and 10-second pouring time were taken into account as the optimum casting conditions. With respect to a hot forging test, it is practiced on the basis of a temperature of materials, strain rate, and reduction rate so as to observe each microstructure and examine strain-stress curve simultaneously; examine tensile test and hardness test; eventually set up the optimum hot forging condition. A hot forging test, tensile test, hardness experiment, and microstructure observation were carried out on condition of $70\%$ reduction rate, $500^{\circ}C$ temperature of materials, and 1 strain rate. As a result of those experiments, 330MPa tensile strength, $16.4\%$ elongation, and 122.8Hv hardness were recorded. In oder to get a sound preform which has no unfitting cavity and less flash, two preforms were proposed on the basis of volume rate of the final product; the optimum volume rate of preform for the low control arm was $115\%$. In conclusion, it is confirmed that using the forging material rather than casting materials in casting/forging process is likely to get more superior mechanical properties. Compared with Al6061, performed by means of general forging, moreover, cast/forged Al6061 can not only stimulate productivity by reducing production processes, but cut down the cost of materials by reusing forging scraps.

무전극형광램프의 고온 신뢰성 연구 (High Temperature Reliability Study of Low Frequency In-door Electrodeless Lamp)

  • 정의효;형재필;임성용;임홍우;장중순
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제14권3호
    • /
    • pp.203-207
    • /
    • 2014
  • Electrodeless lamp is famous for its long life. But its reliability is dependent not only on electrodes but also on materials and structures. To evaluate end product's reliability, we studied high temperature durability by $60^{\circ}C$, $75^{\circ}C$ and $90^{\circ}C$ temperature tests, and predicted failure times by an exponential model through regression analysis. However, the test showed that temperature does not affect degradation of electrodeless lamps. Their luminous outputs degrade during the early time of the test (till 250 hours) and then converge to a saturation points. Also, '410nm ~ 530nm' spectrum degrades more than other spectra.

흑연과 지르콘의 상대적인 함량에 따른 마찰특성에 관한 연구 (Influence of the Relative Amount of Graphite and Zirconium Silicate on Friction Characteristics)

  • 김성진;장호
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2000년도 제31회 춘계학술대회
    • /
    • pp.166-172
    • /
    • 2000
  • Friction characteristics of phenolic resin-based friction composites containing threedifferent relative amounts of graphite and zirconium silicate were investigated by using a pad-on-disk type friction tester. Constant temperature test and constant interval test at three different initial temperatures(100. 200, 300$^{\circ}C$) were performed to examine the effects of friction heat on friction characteristics at elevated temperature. The friction composite(FMO.7) with higher content of ZrSiO$_4$showed unstable friction force at higher temperature and resulted in larger fluctuations of vibration during friction test. The abrasive action of ZrSiO$_4$in friction composite impeded stable transfer film and induced higher friction heat at friction interface. Friction oscillations according to the temperature were associated with the formation of transfer film(i'd body layer) on the friction composite and the counter part.

  • PDF

극저온 환경에서 스트레인 게이지의 게이지상수 및 변형률 측정에 관한 연구 (The Characteristic Test for Gage Factors of Strain Gages in Cryogenic Environment)

  • 김갑순;주진원
    • 대한기계학회논문집
    • /
    • 제17권9호
    • /
    • pp.2205-2213
    • /
    • 1993
  • The characteristic test for gage factors of temperature self-compensated strain gages at cryogenic temperature is presented. By joining the international round robin test on electrical strain gages at cryogenic temperatures, the gage factors of three kinds of widely-used strain gages are obtained at the room temperature, the temperatures of liquid nitrogen and liquid helium. The calibration system which produce precise bending strain is by mechanical loading at cryogenic temperature. This paper also presents the creep characteristic of strain gages at maximum strain level.

KS D 3503 SS400 압연강 $179^{\circ}C$에서의 재질열화 연구 (Material Degradation in KS D 3503 SS400 Rolled Steel at $179^{\circ}C$)

  • 백운봉;박종서;남승훈
    • 한국안전학회지
    • /
    • 제21권4호
    • /
    • pp.13-18
    • /
    • 2006
  • In spite of frequent defect in industrial boilers, life assessment or diagnostic method for them has not been actively studied. In this research, SS400 carbon steel used in industrial boilers is simulated with artificial aging heat treatment. To do qualitative life assessment, differences in micro-structures and hardness of SS400 by the degradation time are studied. In addition, variation in material properties by aging was observed with the tensile test at room temperature and $179^{\circ}C$ and changes in ductile to brittle transition temperature was observed with the charpy impact test performed at several test temperature.

주축의 동적거동시 FEM을 이용한 열적 특성에 관한연구. (A Study on the Thermal Specific of Operational Spindle System of Machine Tool by FEM)

  • 임영철;김종관
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2003년도 추계학술대회
    • /
    • pp.396-400
    • /
    • 2003
  • This paper has studied thermal characteristics of machine tool to develope high speed spindle and optimum design condidering the thermal deformation. Comparing the test data of temperature measurement and structural analysis data using FEM, we verifiedthe test validity and predicted thermal deformation, influence of spindle generation of heat, and established cooling system to prevent the thermal deformation. 1) The temperature rise of spindle system depends on increasing number of rotation and shows sudden doubling increment of number of rotation over 7,000rpm. 2) Oil jacket cooling can be effective cooling method below 8,000rpm but, over 8,000rpm, it shows the decrement of cooling effect. 3) Comparing FEM analysis results and revolution test results, we can confirmn approximate temperature change consequently, it is possible to simulate temperature rise and thermal distribution on the inside of spindle system. 4) We can confirm that simulated approach by FEM analysis can be effective method in thermal-appropriate design..

  • PDF