• Title/Summary/Keyword: Test Range

Search Result 8,214, Processing Time 0.035 seconds

Long Duration Current Impulse Withstand Characteristics and Uniformity of ZnO Blocks for High Voltage Surge Arresters (초고압 피뢰기용 ZnO 소자의 장시간 방전내량과 균일성)

  • Cho, Han-Goo;Yoo, Dae-Hoon;Lee, You-Jong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.486-487
    • /
    • 2007
  • This paper describes the evaluation of long duration current impulse withstand characteristics of ZnO blocks for high voltage surge arresters. Four ZnO varistors were manufactured with the general ceramic production method and three abroad varistors were also prepared to be compared. All varistors exhibited high density, which was in the range of $5.42{\sim}5.49g/cm^3$. In the electrical properties, the reference voltage of all samples was in the range of 5.11~5.72kV and the residual voltage was in the range of 8.314~9.305kV. In the long duration current impulse withstand test, sample 2 and 3 failed at the 2nd and 4th shot of series impulse currents, respectively, but the rest survived 18 shots during the test. Before and after this test, the variation ratio of the residual voltage of samples survived were below 1.7%, which were in the acceptance range of 5%.

  • PDF

Consideration for Setting Reference Range for Adrenocorticotropic Hormone Test according to Blood Collection Time (채혈 시간에 따른 부신피질 자극 호르몬 검사의 참고치 설정에 관한 고찰)

  • Ji-Hye Park;Jin-Ju Choi;Soo-Yeon Lim;Seon-Hee Yoo;Sun-Ho Lee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.1
    • /
    • pp.42-46
    • /
    • 2023
  • Purpose The reference range described in Adrenocorticotropic Hormone reagent used in our laboratory is 10-60 pg/mL at 8 a.m. to 10 a.m., and 6-30 pg/mL at 8 p.m. to 10 p.m. However, in the case of outpatients, blood is mainly collected between 10 a.m. and 6 p.m., accounting for 57.8% of the total. Therefore, This study is intended to help make a more accurate diagnosis by reevaluating the reference range provided by the manufacturer of the Adrenocorticotropic Hormone reagent and setting split-timed reference range. Materials and Methods The patients collected blood before 10 a.m. were group A (68 people), and the patients collected blood after 10 a.m. were set to group B (80 people). A T-test was performed between groups to test their significance. And it was confirmed whether it was necessary to set the gender classification as a subgroup. The method of setting the reference range was calculated by the Bayesian's method and the Hoffmann's method. Results The reference range of Group A was 8.6 to 60.6 pg/mL by the Bayesian's method, and the Hoffmann's method was 3.6 to 61.3 pg/mL. The reference range of Group B was 6.9 to 50.5 pg/mL when applying the Bayesian's method, and the Hoffmann method's was 2.3 to 48.9 pg/mL. Conclusion This study was concluded that it was necessary to set the split-timed reference range. Through this study, the later the blood collection time, the lower the level of Adrenocorticotropic Hormone, indicating that blood collection time is important for patients with clinical significance. If a large number of subjects are selected and supplemented in the future, it is believed that systematic and accurate reference range can be set.

  • PDF

Packaging Criterion for Mid-Size Sedan Based on Users' Daily-Life Scenario

  • Chung, Sung-Moon;Lee, Seung-Hwan;Kim, Su-Whan
    • Industrial Engineering and Management Systems
    • /
    • v.11 no.2
    • /
    • pp.196-201
    • /
    • 2012
  • This study has developed a packaging criterion to minimize the level of discomfort which drivers using their vehicles for daily life purposes may experience due to ill designed vehicle packaging of mid-size sedan based on users' daily-life scenario. To find out optimal range of packaging dimension criterion, discomfort levels the test participants with different physical conditions suffer while performing various activities were analyzed. One hundred two test participants were carefully selected to represent entire Korean mid-size sedan owner-drivers. They were directed to test drive on the course designed to simulate mid-size sedan daily-usage scenario. At pre-designed locations, each of questions was asked to the test participants to be answered in the form of 10 point discomfort level score. By analyzing the test results, the optimal range for packaging dimensions was defined to be used as a packaging criterion.

Evaluation for Marine Ground in Pusan Area using PMT (공내재하시험을 이용한 부산지역 해저지반의 평가)

  • 김동철;최용규
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03b
    • /
    • pp.338-345
    • /
    • 2000
  • In this study, applicability of PMT in domestic area and test procedure were studied. At six test holes of three construction sites in Pusan, PMT using Elastometer-200 type was done. The problems during test were investigated and the test results were analysed. Limit pressure, p$\sub$ι/ could be determined by p- Δv/v method. Using PMT results, marine soil in Pusan could be classified approximately. Net limit pressure value was in the range of 6.4 ∼ 22.5 kg/$\textrm{cm}^2$ in clay, 2.2 ∼ 30.0 kg/$\textrm{cm}^2$ in sand, 13.0 ∼ 58.0 kg/$\textrm{cm}^2$ in weathered soil and 47.0 ∼ 190.0 kg/$\textrm{cm}^2$ in weathered rock. Also, E$\sub$m//p$\sub$ι/ value was in the range of 2.4 ∼ 7.0 in clay, 2.6 ∼ 12.1 in sand, 6.8 ∼ 17.1 in weathered soil and 7.2 ∼ 29.6 in weathered rock.

  • PDF

A Study on the Model Test Scheme for Establishing the Mathematical Model of Hydrodynamic Force and Moment Acting on a Slowly Moving Ship (저속시 선체에 작용하는 유체력 수학모형 정립을 위한 모형시험 방안 연구)

  • Yoon, Hyeon-Kyu;Kim, Sun-Young
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.42 no.2 s.140
    • /
    • pp.98-104
    • /
    • 2005
  • The mathematical models of hydrodynamic force and moment acting on a ship at low speed range should be established differently from the ones at nominal cruising speed range since a ship moves with large drift angle or rotates in a stationary position. We modified widely used Yoshimura's cross flow model in order to apply the system identification method to estimate parameters in the model. The apparatus and the procedure of free running model test were suggested so that the parameters in the model be estimated. The validity of our proposing modified model and test procedure was confirmed by comparison with the results of simulated model test.

Design to Realtime Test Data Topic Utilize of Data Distribution Service (데이터 분산 서비스를 활용한 실시간 시험자료 토픽 설계)

  • Choi, Won-gyu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.7
    • /
    • pp.1447-1454
    • /
    • 2017
  • The realtime test data topic means that process for the data efficiently from many kinds of measurement device at the test range. There are many measurement devices in test range. The test range require accurate observation and determine on test object. In this realtime test data slaving framework system, the system can produce variety of test informations and all these data also must be transmitted to test information management or display system in realtime. Using RTI DDS(Data Distribution Service) middle ware Ver 5.2, we can product the efficiency of system usability and QoS(Quality of Service) requirements. So the application user enables to concentrate on applications, not middle ware. As the reason, Complex function is provided by the DDS, not the application such as Visualization Software. In this paper, I suggest the realtime test data topic on slaving framework of realtime test data based on DDS at the test range system.

Test-retest Reliability and Intratest Repeatability of Measuring Cervical Range of Motion Using Inertial Measurement Unit (관성측정장치를 이용한 경추관절 가동범위 측정의 검사 내 반복성 및 검사-재검사 신뢰도 연구)

  • Kim, Hyun Ho;Kim, Kyung Wook;Park, Ji Min;Kim, Eun Seok;Lee, Min Jun;Kang, Jung Won;Lee, Sang Hoon;Park, Young Bae
    • Journal of Acupuncture Research
    • /
    • v.30 no.4
    • /
    • pp.25-33
    • /
    • 2013
  • Objectives : To assess the test-retest reliability and the intratest repeatability in measuring the cervical range of motion of healthy subjects with wireless microelectromechanical system inertial measurement unit(MEMS-IMU) system and to discuss the feasibility of this system in the clinical setting to evaluate the cervical spine musculoskeletal. Methods : 12 healthy people who were evaluated as no- or mild-disability with neck disability index were participated. Their cervical motion were measured with IMU twice in consecutive two days for the test-retest reliability study. Intratest repeatability was calculated in the two tests separately. The calculated intraclass correlation coefficients(ICC) were discussed and compared with the those of the previous studies. Results : Cervical range of motion data were acquired and statistically processed: left rotation($61.64^{\circ}$), right rotation($65.12^{\circ}$), extension($61.98^{\circ}$), flexion($52.81^{\circ}$), left bending($39.31^{\circ}$), right bending($41.08^{\circ}$). ICCs were 0.77~0.98(intratest repeatability) and 0.74~0.93 (test-retest reliability) in the primary motion. In the coupling motion, intratest repeatability ICCs were 0.93~ 0.99(transverse primary plane), 0.88~0.97(saggital primay plane), and 0.77~0.93(coronal primary plane). Test-retest reliability of coupling motion were 0.90~0.97(transverse primary plane), 0.00~0.72(saggital primary plane), and 0.04~0.76(coronal primary plane). Conclusions : Several types of range-of-motion devices are now on use in many fields including medicine, but the practicality of the devices in clinical use is questionable for the convenient and economical aspects. In this study, we presented the reliability of cervical range of motion test with the developed wireless MEMS-IMU system and discussed its potential utility in clinical use.

Measurement of UHF-Band Propagation Loss for the Long Range Maritime Communication Environment (장거리 해상 통신 환경에서의 UHF 대역 전파 손실 측정)

  • Kim Kyun-Hoi;Tak Youn-Do;Shin Seok-Hyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.5 s.108
    • /
    • pp.490-499
    • /
    • 2006
  • In this paper, we present the newly developed propagation toss model of a long range maritime communication channel, measured by a ground to air flight test, and discuss its validity compared with the predictive value based on the spherical earth reflection model. To measure the propagation loss, actual flight test was performed in the Yellow Sea and the measurement of receiving signal strength was made for overall test range. As far as the test condition is concerned, it is expected that the receiving signal strength must be interfered with the reflected wave by an island existing around the reflection point. Therefore we introduce some modifications on the conventional spherical earth reflection model by including the effect due to the reflected wave from the island. And then, we compare the path loss measured by flight test with that one analyzed by the spherical earth reflection model accounting for reflected wave of the island. As a result of the comparison, it is verified to predict the path loss accurately by the spherical earth reflection model including the effect due to the reflected wave from an island for a long range ground to air communication.

The Effect of an Exercise Program with Patella Mobilization on Range of Motion, Muscle Strength and Gait in Patients with Total Knee Arthroplasty (무릎뼈 관절가동술을 동반한 운동프로그램이 무릎관절 전치환술 환자의 관절가동범위, 근력, 보행에 미치는 영향)

  • Lee, Jaehong;Min, Dongki;Lee, Sangjae
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.1
    • /
    • pp.1-14
    • /
    • 2020
  • Purpose : The purpose of this study was to investigate the effect of an exercise program with patella mobilization on range of motion, muscle strength, and gait in patients with total knee arthroplasty. Methods : Thirty patients under the age of 65 who visited the T hospital in Daegu Metropolitan City and underwent total knee arthroplasty surgery were selected for this study. Fifteen patients were randomly assigned to the experimental group and took part in an exercise program with patella mobilization, and fifteen patients were randomly assigned to the control group and took part in just the exercise program. Each group took part in their intervention three times a week for four weeks. The measurement tools used included a goniometer, handheld dynamometer, and 10-meter walking test. In the statistical analysis results, to compare the about pre and post test differences within each group, a paried t-test was used, and to compare the differences between each group, an independent t-test was used. Results : There was a significant difference (p<.05) in the range of motion, muscle strength of the quadriceps femoris and, hamstrings, and 10-meter walking test within each individual group and between the two groups before and after the intervention (p<.05). Conclusion : All the results for the experimental group were significant. Therefore, it is expected that an exercise program with patella mobilization will be helpful for the recovery of the knee joint in patients who have undergone total knee arthroplasty.

Shearing Characteristics of Aluminium Rods Using Plane Strain - Shear Box Test and Close Range Photogrammetric Technique (평면변형률 전단시험과 근거리 사진계측기법을 통한 알루미늄 봉의 전단특성)

  • Lee, Yong-Joo;Song, Ki-Jung
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.8
    • /
    • pp.5-14
    • /
    • 2010
  • To simulate two-dimensional plane-strain conditions in the laboratory model test, the side frictional resistance between the soil and thick glass or plastic sheet of the soil container should be reduced as much as possible. However, in fact this side friction cannot be removed completely. In this paper, the ground model simulated as a multi-sized aluminium rod mixture was introduced to get rid of the side frictional resistance and applied to the laboratory shear box test. In addition, an application of the close range photogrammetric technique to the shear box test was validated. As a result, it was found that a mean value of dilation angle from the close range photogrammetry was close to the dilation angle defined by the curve of shear strain vs. volumetric strain.