• Title/Summary/Keyword: Test Platform

Search Result 1,056, Processing Time 0.031 seconds

Influence of the connection design and titanium grades of the implant complex on resistance under static loading

  • Park, Su-Jung;Lee, Suk-Won;Leesungbok, Richard;Ahn, Su-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.5
    • /
    • pp.388-395
    • /
    • 2016
  • PURPOSE. The purpose of this study was to evaluate the resistance to deformation under static overloading by measuring yield and fracture strength, and to analyze the failure characteristics of implant assemblies made of different titanium grades and connections. MATERIALS AND METHODS. Six groups of implant assemblies were fabricated according to ISO 14801 (n=10). These consisted of the combinations of 3 platform connections (external, internal, and morse tapered) and 2 materials (titanium grade 2 and titanium grade 4). Yield strength and fracture strength were evaluated with a computer-controlled Universal Testing Machine, and failed implant assemblies were classified and analyzed by optical microscopy. The data were analyzed using the One-way analysis of variance (ANOVA) and Student's t-test with the level of significance at P=.05. RESULTS. The group $IT4_S$ had the significantly highest values and group IT2 the lowest, for both yield strength and fracture strength. Groups $IT4_N$ and ET4 had similar yield and fracture strengths despite having different connection designs. Group MT2 and group IT2 had significant differences in yield and fracture strength although they were made by the same material as titanium grade 2. The implant system of the similar fixture-abutment interfaces and the same materials showed the similar characteristics of deformation. CONCLUSION. A longer internal connection and titanium grade 4 of the implant system is advantageous for static overloading condition. However, it is not only the connection design that affects the stability. The strength of the titanium grade as material is also important since it affects the implant stability. When using the implant system made of titanium grade 2, a larger diameter fixture should be selected in order to provide enough strength to withstand overloading.

A Study on Interaction of Gaze-based User Interface in Mobile Virtual Reality Environment (모바일 가상현실 환경에서의 시선기반 사용자 인터페이스 상호 작용에 관한 연구)

  • Kim, Mingyu;Lee, Jiwon;Jeon, Changyu;Kim, Jinmo
    • Journal of the Korea Computer Graphics Society
    • /
    • v.23 no.3
    • /
    • pp.39-46
    • /
    • 2017
  • This study proposes a gaze-based user interface to provide user oriented interaction suitable for the virtual reality environment on mobile platforms. For this purpose, a mobile platform-based three-dimensional interactive content is produced, to test whether the proposed interface increases user satisfaction through the interactions in a mobile virtual reality environment. The gaze-based interface, the most common input method for mobile virtual reality content, is designed by considering two factors: the field of view and the feedback system. The performance of the proposed gaze-based interface is analyzed by conducting experiments on whether or not it offers motives for user interest, effects of enhanced immersion, differentiated formats from existing ones, and convenience in operating content.

Development of Small SAR System and Signal Processing Algorithm for Full-Polarization Data Acquisition with 30 cm Resolution (30 cm급 완전편파 데이터 획득을 위한 소형 SAR 시스템 개발 및 신호처리)

  • Song, Jung-Hwan;Jung, Chul-Ho;Choi, Jong-Joon;Kim, Jin-Soo;Lee, Woo-Kyung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.9
    • /
    • pp.707-721
    • /
    • 2018
  • In this paper, a small synthetic aperture radar(SAR) system with 30 cm resolution is proposed, and a RAW data-based Doppler parameter estimation and motion compensation algorithm is described in detail. Acquisition of both PolSAR and InSAR data are enabled because there are two channels each in the transmitter and receiver modules. Automotive-based field work is performed to obtain PolSAR data, and signal processing results are ultimately obtained. A motion compensation algorithm is used to mitigate the residual phase error due to platform oscillation, and improved performance is obtained with the motion compensation algorithm using the automotive field test data.

Impact of UV curing process on mechanical properties and dimensional accuracies of digital light processing 3D printed objects

  • Lee, Younghun;Lee, Sungho;Zhao, Xing Guan;Lee, Dongoh;Kim, Taemin;Jung, Hoeryong;Kim, Namsu
    • Smart Structures and Systems
    • /
    • v.22 no.2
    • /
    • pp.161-166
    • /
    • 2018
  • In the last decade, there has been an exponential increase of scientific interest in smart additive manufacturing (AM) technology. Among the different AM techniques, one of the most commonly applied processes is digital light processing (DLP). DLP uses a digital projector screen to flash an ultraviolet light which cures photopolymer resins. The resin is cured to form a solid to produce parts with precise high dimensional accuracy. During the curing process, there are several process parameters that need to be optimized. Among these, the exposure time affects the quality of the 3D printed specimen such as mechanical strength and dimensional accuracy. This study examines optimal exposure times and their impact on printed part. It was found that there is optimal exposure time for printed part to have appropriate mechanical strength and accurate dimensions. The gel fraction and TGA test results confirmed that the improvement of mechanical properties with the increasing UV exposure time was due to the increase of crosslinked network formation with UV exposure time in acrylic resins. In addition, gel fraction and thermogravimetric analysis were employed to microscopically investigate how this process parameter impacts mechanical performance.

Prevention of Exhaust Gas Back Flow in Large Container Carriers (대형 컨테이너선의 배기가스 역류 개선 방안 연구)

  • Yang, Jiman;Gyea, Sangkyoung;Yun, Jeomjin;Noh, Hyeonseok;Cho, Daehwan;Choi, Jooyol
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2013.12a
    • /
    • pp.30-34
    • /
    • 2013
  • Prevention of exhaust gas back flow becomes a great interest to shipyards and shipowners in large container carriers because exhaust gas pollutes cargoes, flows back into the deck house and the engine room area through fresh air intakes and fan rooms, gives harmful damages to the crew's health and also gives thermal damages to electric equipments on the navigation deck. The phenomena of exhaust gas back flow has been studied with the analysis of sea trial records and wind tunnel tests and the height of the exhaust gas pipe, the front area of the deck house, the inflow speed and the position of the radar mast platform has been confirmed as the principal factors of exhaust gas back flow phenomena. The simple empirical formula to estimate exhaust gas back flow phenomena and the design guidances of exhaust gas related structures on deck has been introduced. In future, parametric studies for the exhaust gas back flow factors will be carried out with the CFD analysis. The results of this study will be the guide for development of the prevention method of exhaust gas back flow phenomena for large container carriers.

  • PDF

Swelling and Proxyphylline Release Kinetics of Enzyme-Digestible Swelling Hydrogel Tablet (효소 소화성 하이드로겔 정제의 팽윤 및 프록시필린 방출 특성)

  • Shim, Chang-Koo;Lee, Young-Mee;Yeo, So-Hyeon
    • YAKHAK HOEJI
    • /
    • v.36 no.3
    • /
    • pp.212-219
    • /
    • 1992
  • Although oral route is the most convenient route for drug administration, the short and variable transit of drug through GI tract restricts the sustained drug absorption after oral administration. Thus, for sustained absorption of drugs, it is desirable to prolong the GI transit time by retaining the dosage forms in the stomach. In this study, the enzyme-digestible swelling hydrogel was synthesized by heating the mixed solution of N-vinyl-2-pyrrolidone[monomer], acrylated albumin[crosslinking agent] and proxyphylline[drug] at $65^{\circ}C$ for 10 hours in the cylindrical test tube. The resultant hydrogel tablet (diameter; 0.77 cm, thickness; 0.47 cm) was designed to swell in the gastric fluid after oral administration to such a size that passing through the pylorus could be inhibited during the drug release. After releasing drug, the hydrogel was expected to be degraded by pepsin, an enzyme in the stomach, and eventually solubilized. Actually, the hydrogel synthesized in the study swelled to a size larger than the diameter of the pylorus ($1.3{\pm}0.7$ cm) and slowly digested in the presence of pepsin. Drug release from the hydrogel was prolonged up to about 12 hours. The swelling kinetics was dependent on albumin acrylation time, drug content and gel thickness. Particularly the gel thickness was the most important factor that influences on drug release. By adjusting these factors, the albumin-crosslinked hydrogel was expected to be retained in the stomach for up to 60 hours and used as a potential platform of drugs for long-term GI absorption.

  • PDF

Effects of Ginseng Radix on the ischemia-induced 4-vessel occlusion and cognitive impairments in the rat

  • Kim, Young-Ock
    • Journal of Ginseng Research
    • /
    • v.31 no.1
    • /
    • pp.44-50
    • /
    • 2007
  • Ginseng powerfully tonifies the original Qi. Ginseng used for insomnia, palpitations with anxiety, restlessness from deficient Qi and blood and mental disorientation. In order to investigate whether Ginseng cerebral ischemia-induced neuronal and cognitive impairments, we examined the effect of Ginseng on ischemia-induced cell death in the hippocampus, and on the impaired learning and memory in the Morris water maze and passive avoidance in rats. Ginseng when administered to rat at a dose of 200 mg/kg i.p. water extracts to 0 minutes and 90 minutes after 4-VO, significantly neuroprotective effects by 86.4% in the hippocampus of treated rats. For behavior test, rats were administered Ginseng (200mg/kg p.o.) daily for two weeks, followed by their training to the tasks. Treatment with Ginseng produced a marked improvement in escape latency to find the platform in the Morris water maze. Ginseng reduced the ischemia-induced learning disability in the passive avoidance. Consistent with behavioral data, treatments with Ginseng reduced jschemia-induced cell death in the hippocampal CA1 area. Oxidative stress is a causal factor in the neuropathogenesis of ischemic-reperfusion injury. Oxidative stress was examined in a rat model of global brain ischemia. The effects of Ginseng on lipid peroxidation (inhibition of the production of malondialdehyde, MDA) in different regions of the rat brain were studied. Ferrous sulfate and ascorbic acid (FeAs) were used to induce lipid peroxidation. The antiperoxidative effect showed 48-72% protection from tissue damage as compared with untreated animals. These results showed that Ginseng have a protective effect against ischemia-induced neuronal loss and learning and memory damage.

Study on the Modeling of Health Medical Examination Knowledge Base Construction using Data Analysis based on AI (인공지능 기반의 데이터 분석을 적용한 건강검진 지식 베이스 구축 모델링 연구)

  • Kim, Bong-Hyun
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.6
    • /
    • pp.35-40
    • /
    • 2020
  • As we enter the society of the future, efforts to increase healthy living are a major area of concern for modern people. In particular, the development of technology for a healthy life that combines ICT technology with a competitive healthcare industry environment is becoming the next growth engine. Therefore, in this paper, artificial intelligence-based data analysis of the examination results was applied in the health examination process. Through this, a research was conducted to build a knowledge base modeling that can improve the reliability of the overall judgment. To this end, an algorithm was designed through deep learning analysis to calculate and verify the test result index. Then, the modeling that provides comprehensive examination information through judgment knowledge was studied. Through the application of the proposed modeling, it is possible to analyze and utilize big data on national health, so it can be expected to reduce medical expenses and increase health.

Quantitative and Qualitative Differences according to the Shoe Type for the Grand Jete Landing in Ballet

  • Yi, Kyung-Ok;Park, Hye-Rhee
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.1
    • /
    • pp.25-29
    • /
    • 2011
  • The purpose of this study was to analyze quantitative and qualitative differences according to shoe type for the grand jete landing in ballet. The subjects for this study were 9 female ballet majors with an average of 12 years of experience. Subjects jumped, performing a front split, and landed on 1 foot, a movement called the grand jete. Analysis was performed on the students' landing. Independent variables were 3 shoe types: split sole, traditional out sole, and 5-toed forefoot shoes, with bare feet as a control group. Dependent variables were vertical passive ground reaction force and qualitative elements. Passive ground reaction force variables(maximum passive peak value, number of passive peaks, passive force-time integral, and center of pressure) were measured by the Kistler 9281B Force Platform. Qualitative elements were comfort, cushioning, pain, and fit. Statistical analysis included both 1-way ANOVA and Tukey's test for follow-up. Finalized data demonstrated that the 5-toed forefoot shoe allows the forefoot to expand and the toes to individually press down upon landing, increasing foot contact with the surface. Five-toed forefoot shoes minimize passive peaks and pain, while increasing comfort, cushioning, and fit. Most ballet movements are composed of jumping, balancing, landing, and spinning. Wearing 5-toed forefoot shoes allows for a natural range of movement in each toe, to improve both technique and balance. Pain and injuries from ballet can be minimized by wearing the correct shoe type. According to this analysis, it is possible to customized ballet shoes to increase the efficiency of techniques and movements.

Comparison of fit accuracy and torque maintenance of zirconia and titanium abutments for internal tri-channel and external-hex implant connections

  • Siadat, Hakimeh;Beyabanaki, Elaheh;Mousavi, Niloufar;Alikhasi, Marzieh
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.271-277
    • /
    • 2017
  • PURPOSE. This in vitro study aimed to evaluate the effect of implant connection design (external vs. internal) on the fit discrepancy and torque loss of zirconia and titanium abutments. MATERIALS AND METHODS. Two regular platform dental implants, one with external connection ($Br{\aa}nemark$, Nobel Biocare AB) and the other with internal connection (Noble Replace, Nobel Biocare AB), were selected. Seven titanium and seven customized zirconia abutments were used for each connection design. Measurements of geometry, marginal discrepancy, and rotational freedom were done using video measuring machine. To measure the torque loss, each abutment was torqued to 35 Ncm and then opened by means of a digital torque wrench. Data were analyzed with two-way ANOVA and t-test at ${\alpha}=0.05$ of significance. RESULTS. There were significant differences in the geometrical measurements and rotational freedom between abutments of two connection groups (P<.001). Also, the results showed significant differences between titanium abutments of internal and external connection implants in terms of rotational freedom (P<.001). Not only customized internal abutments but also customized external abutments did not have the exact geometry of prefabricated abutments (P<.001). However, neither connection type (P=.15) nor abutment material (P=.38) affected torque loss. CONCLUSION. Abutments with internal connection showed less rotational freedom. However, better marginal fit was observed in externally connected abutments. Also, customized abutments with either connection could not duplicate the exact geometry of their corresponding prefabricated abutment. However, neither abutment connection nor material affected torque loss values.