• 제목/요약/키워드: Test Loads

검색결과 2,161건 처리시간 0.03초

4인승 선미익 경항공기 전기체 정적 구조시험 (Full Scale Airframe Static Test of 4 Seater Canard Airplane)

  • 신정우;김성찬;김성준;채동철;이상욱;김태욱;심재열
    • 한국군사과학기술학회지
    • /
    • 제9권4호
    • /
    • pp.15-23
    • /
    • 2006
  • In this paper, full-scale airframe static test of 4-seater canard airplane(the Firefly) was explained. From the results of the structural analysis, 5 design limit loads test conditions and 11 design ultimate loads test conditions were selected. Test loads analysis was performed and test fixtures and load control system(LCS) were prepared to realize the test loads. To protect the test article during the test, the overload protection system was prepared. Strain and deflection values were acquired through the data acquisition system(DAS) to verify the structural analysis results.

랜덤하중에 의한 RC보의 피로시험법에 관한 연구 (Fatigue Test Method for RC Beam Under Random Loading)

  • 권혁문;사림신장;정상정일
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1993년도 가을 학술발표회 논문집
    • /
    • pp.179-183
    • /
    • 1993
  • Loads acting on concrete structures are completely random in nature with respect to frequency, magnitude and order of loading, and are essentially distinct from the loads in two-stage and variable load fatigue test. Thus, this study proposes the fatigue test method generating random loads based on the analyzed result.

  • PDF

Thermal Fatigue Test of an Annular Structure

  • Hwang Jeong-Ki;Suh Chang-Min;Kim Chae-Ho
    • Journal of Mechanical Science and Technology
    • /
    • 제20권1호
    • /
    • pp.59-65
    • /
    • 2006
  • A half-scaled large test model for the main components of the real annular structure was built and the thermal behaviors were experimented and obtained by thermal cyclic loads. The model design and the test conditions for the thermal loads were determined to take into consideration the thermal and mechanical loads acting on the real annular structure by finite element analyses. Temperature profiles and strains of the main components of the model were measured at an early stage of the test and periodically throughout the test in the given test conditions. After completion of the thermal cyclic tests, no evidence of crack initiation and propagation were identified by a dye penetration test. The measured strains at the critical parts were slightly increased proportionally with the increase in the number of the thermal cycles.

Experimental investigation of characteristics of torsional wind loads on rectangular tall buildings

  • Li, Yi;Zhang, J.W.;Li, Q.S.
    • Structural Engineering and Mechanics
    • /
    • 제49권1호
    • /
    • pp.129-145
    • /
    • 2014
  • In order to investigate the characteristics of torsional wind loads on rectangular tall buildings, five models with different rectangular cross-sections were tested in a boundary wind tunnel. Based on the test results, the RMS force coefficients, power spectrum densities as well as vertical correlation functions of torsional wind loads were analyzed. Formulas that took the side ratio as parameters were proposed to fit the test results above. Comparisons between the results calculated by the formulas and the wind tunnel measurements were made to verify the reliability of the proposed formulas. An simplified expression to evaluate the dynamic torsional wind loads on rectangular tall buildings in urban terrain is presented on basis of the above formulas and has been proved by a practical project. The simplified expressions as well as the proposed formulas can be applied to estimate wind-induce torsional response on rectangular tall buildings in the frequency domain.

엘리베이터 하중시험 대체 검사기법 개발 (New Inspection Skill for Load-test of Hydraulic Elevator without Actual Loads)

  • 허윤섭;엄용기
    • 전기학회논문지P
    • /
    • 제62권3호
    • /
    • pp.127-132
    • /
    • 2013
  • In order to check traction of the elevator, the load-test is positively necessary on the inspection of elevator in Korea. So actual loads are used in the elevator car for the load-test. However, some of advanced countries in Europe, for example Germany, are using the alternative method with no load test instead of traditional load-test. Commonly hydraulic elevator, compared to passenger elevator is mainly used for loading heavy weights. It requires a great deal of labor to carry out load-test. The reason is why we developed a new inspection skill for the load-test of hydraulic elevator without actual loads. The results of studies show that the new method of the load-test can be replace the traditional load-test.

소형위성발사체 상단부의 음향하중시험 (Acoustic Loads Test of the Upper Stage of KSLV-I)

  • 전영두;박종찬;정의승;박정주;조광래
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.224-227
    • /
    • 2007
  • This paper introduces the results of acoustic loads test conducted on the upper stage assembly of KSLV-I, which is the first Korea space launch vehicle. A launch vehicle and its payloads are subjected to severe acoustic pressure loading when they lift off and ascent during the transonic periods. Acoustic loadings are spreaded out broad frequncy-spectrum up to 10,000Hz. Acoustic loads are a primary source of structural random vibration of the upper stage and payloads. Therefore, in order to verify the structural integrity of the upper stage assembly of KSLV-I and the survivability of its components under severe random vibration environment, acoustic loads test is conducted in the high intensity acoustic chamber with 142dB (overall SPL). The results show the structural design and component random vibration specifications well meet with the environmental requirements.

  • PDF

반복하중 하의 엘보우 변형 및 손상 특성 평가를 위한 모사시험 방법 제안 (Proposal of a Simulated Test Method for the Evaluation of Deformation and Failure Characteristics of Pipe Elbows under Cyclic Loads)

  • 김진원;이대영;박흥배
    • 한국압력기기공학회 논문집
    • /
    • 제16권1호
    • /
    • pp.1-10
    • /
    • 2020
  • This study proposed a simulated test method using ring specimen to evaluate the deformation and failure characteristics of pipe elbows under a large amplitude cyclic load. The validity of the test method was demonstrated by finite element (FE) analysis of pipe elbow and ring specimen under cyclic loads. The results showed that the proposed test method adequately simulates the distribution of circumferential strain at crown of pipe elbows where cracks occur under cyclic loads and presents the cyclic hardening behavior of pipe elbows. The parametric FE analysis showed that consistent simulated test results could be obtained when the test section of the ring specimen is longer than 1/2 of the inner diameter of the ring specimen and the radius of the inner loading jig is less than 1/4 of the inner diameter of the specimen.

Field testing and numerical modeling of a low-fill box culvert under a flexible pavement subjected to traffic loading

  • Acharya, Raju;Han, Jie;Parsons, Robert L.;Brennan, James J.
    • Geomechanics and Engineering
    • /
    • 제11권5호
    • /
    • pp.625-638
    • /
    • 2016
  • This paper presents field study and numerical modeling results for a single-cell low-fill concrete box culvert under a flexible pavement subjected to traffic loading. The culvert in the field test was instrumented with displacement transducers to capture the deformations resulting from different combinations of static and traffic loads. A low-boy truck with a known axle configuration and loads was used to apply seven static load combinations and traffic loads at different speeds. Deflections under the culvert roof were measured during loading. Soil and pavement samples were obtained by drilling operation on the test site. The properties of the soil and pavement layers were determined in the laboratory. A 3-D numerical model of the culvert was developed using a finite difference program FLAC3D. Linear elastic models were used for the pavement layers and soil. The numerical results with the material properties determined in the laboratory were compared with the field test results. The observed deflections in the field test were generally smaller under moving loads than static loads. The maximum deflections measured during the static and traffic loads were 0.6 mm and 0.41 mm respectively. The deflections computed by the numerical method were in good agreement with those observed in the field test. The deflection profiles obtained from the field test and the numerical simulation suggest that the traffic load acted more like a concentrated load distributed over a limited area on the culvert. Elastic models for culverts, pavement layers, and surrounding soil are appropriate for numerical modeling of box culverts under loading for load rating purposes.

건축구조물의 시스템 식별을 통한 무리보행의 해석 (Analysis of Group Walking Loads by System Identification of Building Structures)

  • 김태호;민경원;이동근
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 춘계 학술발표회논문집
    • /
    • pp.267-274
    • /
    • 2003
  • The objective of this study is to estimate the frequency characteristics of group walking loads based on the information of measured responses. At first, dynamic properties such as natural frequencies and modes are obtained from input/output relation for building structures by heel drop test. Second, a method to estimate group walking loads by the transfer functions from measured responses to group walking loads is proposed. The method turned out to estimate the group walking loads accurately. Higher modes could be important in estimating the amplitude of group walking loads with the information of single walking load.

  • PDF

Load-carrying capacities and failure modes of scaffold-shoring systems, Part I: Modeling and experiments

  • Huang, Y.L.;Chen, H.J.;Rosowsky, D.V.;Kao, Y.G.
    • Structural Engineering and Mechanics
    • /
    • 제10권1호
    • /
    • pp.53-66
    • /
    • 2000
  • This paper proposes a simple numerical model for use in a finite analysis (FEA) of scaffold-shoring systems. The structural model consists of a single set of multiple-story scaffolds with constraints in the out-of-plane direction at every connection joint between stories. Although this model has only two dimensions (termed the 2-D model), it is derived from the analysis of a complete scaffold-shoring system and represents the structural behavior of a complete three-dimensional system. Experimental testing of scaffolds up to three stories in height conducted in the laboratory, along with an outdoor test of a five-story scaffold system, were used to validate the 2-D model. Both failure modes and critical loads were compared. In the comparison of failure modes, the computational results agree very well with the test results. However, in the comparison of critical loads, computational results were consistently somewhat greater than test results. The decreasing trends of critical loads with number of stories in both the test and simulation results were similar. After investigations to explain the differences between the computationally and experimentally determined critical loads, it was recommended that the 2-D model be used as the numerical model in subsequent analysis. In addition, the computational critical loads were calibrated and revised in accordance with the experimental critical loads, and the revised critical loads were then used as load-carrying capacities for scaffold-shoring systems for any number of stories. Finally, a simple procedure is suggested for determining load-carrying capacities of scaffold-shoring systems of heights other than those considered in this study.