• Title/Summary/Keyword: Test Lab

Search Result 1,797, Processing Time 0.038 seconds

A Study of the Model-based Testing for Embedded Software in ESTEREL (ESTEREL 임베디드 소프트웨어를 위한 모델 기반 테스트 기법 연구)

  • YANG Jin-Seok;Kim Jin-Hyun;Sim Jae-Hwan;Kim chang-jin;Choi Jin-Young
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2005.11b
    • /
    • pp.337-339
    • /
    • 2005
  • 본 논문에서는 임베디드 시스템의 제어를 위해 동기화 언어인 에스테렐로 개발된 소프트웨어가 소프트웨어 요구사항을 만족하는지 확인하기 위한 Model-based Test(MBT) 프레임 워크를 제안한다. 제안된 프레임 워크를 기반으로 작성한 프로토 타입의 테스트 도구는 요구사항 모델을 창조하여 On-the-fly 방법을 통해 테스트 케이스를 랜덤하게 자동으로 생성하여 소프트웨어에 대하 테스트를 자동으로 수행한다. 간단한 case study로 레고 마인드스톰 로봇 제어 소프트웨어에 MBT를 수행하고 그 결과를 확인한다.

  • PDF

K-Band Low Noise Receiver Module Using MMIC Technology

  • Yu, Kyung-Wan;Uhm, Man-Seok;Yom, In-Bok;Chang, Dong-Pil;Lee, Jae-Hyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.1
    • /
    • pp.110-115
    • /
    • 2000
  • A K-band GaAs MMIC receiver module has been developed using 0.15 ${\mu}{\textrm}{m}$ HEMT technology process. It incorporates two front end low noise amplifiers, a double balanced diode mixer, and filters. The RF input frequency ranges 20.1 to 21 GHz and the IF output 1.1 to 2 GHz. Test results show an overall conversion gain of more than 27 dB, and less than a 2.2 dB noise figure. The image-rejection ratio greater than 21 dB has been obtained. The isolation between RF and IF ports is better than 27 dB, and between LO and IF is more than 50 dB.

  • PDF

The estimation of uncertainty in new measuring system used for high-power tests (대전력시험의 새로운 측정시스템에 대한 불확도 평가)

  • Suh, Yoon-Taek;Kim, Maeng-Hyun;Kim, Dae-Won;Kang, Young-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.540-542
    • /
    • 2003
  • In the high-power tests to be performed on electrical apparatus as circuit-breaker, load switch, fuse, transformers, insulators, cable and so on, the results of tests on these apparatus are extremely important to evaluate the performance of test object. The reliability of the results depends on the reliability of measuring systems used in the laboratories where tests are performed. This paper deals with factors of uncertainty and describes estimation of uncertainty in new measuring system used in high-power testing LAB. 1 in KERI.

  • PDF

Implementation of Efficient Routing Algorithm for Heterogeneous Home Networks based on PLC and IEEE 802.15.4 (전력선 통신과 IEEE 802.15.4를 기반한 이종 홈 네트워크를 위한 효율적 라우팅 알고리즘 구현)

  • Ha, Jae-Yeol;Lee, Kam-Rok;Heo, Jong-Man;Kim, Nam-Hun;Choi, Hae-Sul;Jeong, Beom-Jin;Gwon, Uk-Hyeon
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.7-8
    • /
    • 2007
  • In this paper, an efficient routing algorithm for the heterogeneous home network in which IEEE 802.15.4 compensates for limitations of PLC based home networks. The efficient routing algorithm changes the broadcast period of routing information frame according to the mobility of the node. We implemented the routing algorithm and built a test-bed.

  • PDF

Bioequivalence of Cyclosporine A 100 mg Soft Capsules (Cipol-N® vs. Sandimmun Neoral®) in Healthy Korean Volunteers

  • Huh, Yong-Ho;Park, Eun-A;Chung, Youn-Bok;Pyo, Hee-Soo;Kwon, Oh-Seung
    • Journal of Pharmaceutical Investigation
    • /
    • v.38 no.5
    • /
    • pp.343-348
    • /
    • 2008
  • The bioequivalence of two cyclosporine A (CyA) 100 mg soft capsules (Chong Kun Dang's $Cipol-N^{(R)}$ as the test drug; Korea Novartis' Sandimmun $Neoral^{(R)}$ as the reference drug) was assessed in healthy male Korean volunteers after oral administration of 200 mg CyA according to a randomized crossover design. The whole blood samples were analyzed for the determination of parent CyA in the blood by using a validated HPLC/diode array detector method. The mean $AUC_t$ values for reference and test products were $4095.3{\pm}1397.2$ and $3958.3{\pm}1138.2\;ng{\cdot}hr/mL$, respectively. The mean $C_{max}$ values were $1135.9{\pm}293.2\;ng/mL$ for the reference product, and $985.0{\pm}207.9\;ng/mL$ for the test product. $T_{max}$ was $1.6{\pm}0.4\;hr$ for the reference and $1.8{\pm}0.5\;hr$ for the test product. The differences of $AUC_t$, $C_{max}$ and $T_{max}$ were -3.35, -13.28 and +10.63%, respectively. The point estimates and 90% confidence intervals for $AUC_t$ and $C_{max}$ were 0.981 (0.9171 to 1.0514) and 0.876 (0.8229 to 0.9336), respectively. Based on the pharmacokinetic and statistical data, we conclude that these two products are bioequivalent and can be considered interchangeable in the medical practice.

Corrosion Characteristics of a 5Cr-1Mo Steel Specimen by Sodium-Water Reaction (나트륨-물 반응에 의한 5Cr-1Mo Steel 시편의 부식특성)

  • Jeong, Kyung-Chai;Jeong, Ji-Yeong;Park, Jin-Ho;Hwang, Sung-Tai;Kim, Eui-Sik
    • Applied Chemistry for Engineering
    • /
    • v.9 no.7
    • /
    • pp.1023-1029
    • /
    • 1998
  • Small water leak experiment was carried out for the 5Cr-1Mo steel specimen in sodium atmosphere. Perfect re-open time for the leak path of a specimen, by micro leak, was 129 minutes, and its size observed about 2 mm diameter at sodium side. The halos phenomena appeared around of leak spot before the leak path has re-opened, and the size of halos observed was different from the real re-open size of a specimen. Also, the corrosion of a specimen initiated from sodium side, but it did not occur at steam side. In AES analysis, the segregation phenomena of Cr in the specimen was found much more than those of other elements. And also, the sodium compounds formed by sodium-water reaction and deposited onto the leak site of specimen were observed by EPMA analysis and SEM photograph. It is postulated that the corrosion products could be precipitated to form mixed Na Fe Cr compounds.

  • PDF

Treatment Efficiency of Non-Point Source Pollutants Using Modified Filtration System (개선된 여과형 시설의 비점오염물질 처리효율 평가)

  • Kang, Hee-Man;Choi, Ji-Yon;Kim, Lee-Hyung;Bae, Woo-Keun
    • Journal of Wetlands Research
    • /
    • v.13 no.2
    • /
    • pp.161-169
    • /
    • 2011
  • The objective of this study was to evaluate the efficiency of a modified filtration system treating non-point source (NPS) pollutants. The developed Best Management Practice (BMP) technology was designed based on the geographical and climatic characteristics of the site. A lab-scale test experiment was conducted using three different hydraulic loading rates representing the first flush flow, average flow and overflow conditions during a rainfall event. Water quality analysis was performed on the water samples taken at the inflow, outflow and infiltration during the test experiment of the lab-scale BMP. Also, the water and mass balance at different hydraulic loading rates was determined. Results from the lab-scale test experiment showed that the lab-scale BMP had a high removal efficiency of 80-90% for all NPS pollutants. The overflow test condition obtained the lowest removal efficiency among the hydraulic loading rates because it gave less opportunity for the pollutants to be filtered and retained inside system. The infiltration ratio was approximately 1 % of the inflow and outflow. Increasing the infiltration ratio requires technical approach of soil amendment where the BMP is installed.

Guided Missile Assembly Test Set using Encryption AES Rijndael Algorithm (암호화 AES Rijndael 알고리즘 적용 유도탄 점검 장비)

  • Jung, Eui-Jae;Koh, Sang-Hoon;Lee, You-Sang;Kim, Young-Sung
    • Journal of Advanced Navigation Technology
    • /
    • v.23 no.5
    • /
    • pp.339-344
    • /
    • 2019
  • In order to prepare for the rise of data security threats caused by the information and communication technology, technology that can guarantee the stability of the data stored in the missile test set is important. For this purpose, encryption should be performed when data is stored so that it cannot be restored even if data is leaked, and integrity should be ensured even after decrypting the data. In this paper, we apply AES algorithm, which is a symmetric key cryptography system, to the missile test set, and Encrypt and decrypt according to the amount of data for each bit of each AES algorithm. We implemented the AES Rijndael algorithm in the existing inspection system to analyze the effect of encryption and apply the proposed encryption algorithm to the existing system. confirmation of suitability. analysis of capacity and Algorithm bits it is confirmed that the proposed algorithm will not affect the system operation and the optimal algorithm is derived. compared with the initial data, we can confirm that the algorithm can guarantee data undulation.

Comparison of Preservative Efficacy Tests for Water Non-dispersible Cosmetic Formulations (비수분산 특수 제형 화장품에 대한 방부력 시험 비교 연구)

  • Kim, Yong Hyun;Park, Sung Ha;Park, Byoung Jun;Shin, Kye Ho;Kang, Hak Hee
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.47 no.1
    • /
    • pp.9-21
    • /
    • 2021
  • In this study, the difference between the preservative efficacy test (PET) used for water dispersion formulations and PCPC (personal care products council) guidelines alternative test method, direct contact membrane method, and surface mold test should be studied to determine what should be considered during preservative efficacy test of water non-dispersible formulations. We conducted improved PETs when using the alternative test method compared with the test methods used for stick and pressed powder. There was no significant improvement between water-in-silicon emulsions and loose powder using alternative test methods. When we checked the results of the presence and absence of the preservative system for each product, we could see that there were differences in testing methods. As a result, improved levels of results could be obtained using both existing and alternative test methods when measuring preservatives for water non-dispersible formulations. In addition, in the case of stick and pressed powder, the results were more effective when the preservative test method applied to the consumer's method of use was applied.

FLIGHT SOFTWARE DEVELOPMENT FOR HAUSAT-2 ON-BOARD COMPUTER (HAUSAT-2 비행소프트웨어 개발)

  • Shim Chang-Hwan;Ryu Jung-Hwan;Choi Young-Hoon;Chang Young-Keun
    • Bulletin of the Korean Space Science Society
    • /
    • 2006.04a
    • /
    • pp.117-120
    • /
    • 2006
  • HAUSAT-2 flight software was developed by first analyzing the satellite requirements, and incorporating the results into the software. Coding and compiling is done after the software is completed, then individual and integrated tests are performed in order to verify the flight software algorithm. Currently, HAUSAT-2 flight software integrated test has been performed and the test result is serving as a basis for code modification nd additional developments. This paper describes the architecture, development process, and development environment of HAUSAT-2 flight software.

  • PDF